-
1
-
-
0018944552
-
Clinical evaluation of nerve fiber layer atrophy as an indicator of glaucomatous optic nerve damage
-
Quigley HA, Miller NR, George T. Clinical evaluation of nerve fiber layer atrophy as an indicator of glaucomatous optic nerve damage. Arch Ophthalmol. 1980;98:1564-1571.
-
(1980)
Arch Ophthalmol.
, vol.98
, pp. 1564-1571
-
-
Quigley, H.A.1
Miller, N.R.2
George, T.3
-
2
-
-
0015773594
-
Fundoscopy of the retinal nerve fiber layer in neurosurgical practice
-
Hoyt WF. Fundoscopy of the retinal nerve fiber layer in neurosurgical practice. Neurologia Med Chir (Tokyo). 1973; 13:3-20.
-
(1973)
Neurologia Med Chir (Tokyo).
, vol.13
, pp. 3-20
-
-
Hoyt, W.F.1
-
3
-
-
0017610413
-
The nerve fiber layer in the diagnosis of glaucoma
-
Sommer A, Miller NR, Pollack I, Maumenee AE, George T. The nerve fiber layer in the diagnosis of glaucoma. Arch Ophthalmol. 1977;95:2149-2156.
-
(1977)
Arch Ophthalmol.
, vol.95
, pp. 2149-2156
-
-
Sommer, A.1
Miller, N.R.2
Pollack, I.3
Maumenee, A.E.4
George, T.5
-
4
-
-
0018968384
-
Photography of the retinal nerve-fiber layer-an optimized procedure
-
Frisén L. Photography of the retinal nerve-fiber layer-an optimized procedure. Brit J Ophthalmol. 1980;64:641-650.
-
(1980)
Brit J Ophthalmol.
, vol.64
, pp. 641-650
-
-
Frisén, L.1
-
5
-
-
0026254046
-
Optical coherence tomography
-
Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science. 1991;254:1178-1181.
-
(1991)
Science.
, vol.254
, pp. 1178-1181
-
-
Huang, D.1
Swanson, E.A.2
Lin, C.P.3
-
6
-
-
28944452374
-
Spectral domain optical coherence tomography: Ultra-high speed, ultra-high resolution ophthalmic imaging
-
Chen TC, Cense B, Pierce MC, et al. Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging. Arch Ophthalmol. 2005;123:1715-1720.
-
(2005)
Arch Ophthalmol.
, vol.123
, pp. 1715-1720
-
-
Chen, T.C.1
Cense, B.2
Pierce, M.C.3
-
7
-
-
1542398242
-
In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography
-
Nassif N, Cense B, Park BH, et al. In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography. Opt Lett. 2004;29:480-482.
-
(2004)
Opt Lett.
, vol.29
, pp. 480-482
-
-
Nassif, N.1
Cense, B.2
Park, B.H.3
-
8
-
-
0242322532
-
Optical coherence tomography for ultrahigh resolution in vivo imaging
-
Fujimoto JG. Optical coherence tomography for ultrahigh resolution in vivo imaging. Nature Biotechnol. 2003;21: 1361-1367.
-
(2003)
Nature Biotechnol.
, vol.21
, pp. 1361-1367
-
-
Fujimoto, J.G.1
-
9
-
-
0242301675
-
Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
-
de Boer JF, Cense B, Park BH, Pierce MC, Tearney GJ, Bouma BE. Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. Opt Lett. 2003;28:2067-2069.
-
(2003)
Opt Lett.
, vol.28
, pp. 2067-2069
-
-
de Boer, J.F.1
Cense, B.2
Park, B.H.3
Pierce, M.C.4
Tearney, G.J.5
Bouma, B.E.6
-
10
-
-
0029068398
-
Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography
-
Schuman JS, Hee MR, Puliafito CA, et al. Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol. 1995;113:586-596.
-
(1995)
Arch Ophthalmol.
, vol.113
, pp. 586-596
-
-
Schuman, J.S.1
Hee, M.R.2
Puliafito, C.A.3
-
11
-
-
0029851416
-
Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography
-
Schuman JS, Pedut-Kloizman T, Hertzmark E, et al. Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. Ophthalmology. 1996;103: 1889-1898.
-
(1996)
Ophthalmology.
, vol.103
, pp. 1889-1898
-
-
Schuman, J.S.1
Pedut-Kloizman, T.2
Hertzmark, E.3
-
12
-
-
41149149872
-
Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes
-
Budenz DL, Fredette MJ, Feuer WJ, Anderson DR. Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes. Ophthalmology. 2008;115:661-666.
-
(2008)
Ophthalmology.
, vol.115
, pp. 661-666
-
-
Budenz, D.L.1
Fredette, M.J.2
Feuer, W.J.3
Anderson, D.R.4
-
13
-
-
79951950723
-
Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with cirrus HD-OCT in glaucomatous eyes
-
Mwanza JC, Chang RT, Budenz DL, et al. Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with cirrus HD-OCT in glaucomatous eyes. Invest Ophthalmol Vis Sci. 2010;51: 5724-5730.
-
(2010)
Invest Ophthalmol Vis Sci.
, vol.51
, pp. 5724-5730
-
-
Mwanza, J.C.1
Chang, R.T.2
Budenz, D.L.3
-
14
-
-
33847037441
-
Reproducibility of and effect of magnification on optical coherence tomography measurements in children
-
Wang XY, Huynh SC, Burlutsky G, Ip J, Stapleton F, Mitchell P. Reproducibility of and effect of magnification on optical coherence tomography measurements in children. Am J Ophthalmol. 2007;143:484-488.
-
(2007)
Am J Ophthalmol.
, vol.143
, pp. 484-488
-
-
Wang, X.Y.1
Huynh, S.C.2
Burlutsky, G.3
Ip, J.4
Stapleton, F.5
Mitchell, P.6
-
15
-
-
80051572527
-
Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of Spectralis SD-OCT in glaucomatous and healthy control eyes
-
Langenegger SJ, Funk J, Töteberg-Harms M. Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of Spectralis SD-OCT in glaucomatous and healthy control eyes. Invest Ophthalmol Vis Sci. 2011;52:3338-3344.
-
(2011)
Invest Ophthalmol Vis Sci.
, vol.52
, pp. 3338-3344
-
-
Langenegger, S.J.1
Funk, J.2
Töteberg-Harms, M.3
-
16
-
-
0033653784
-
Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography
-
Blumenthal EZ, Williams JM, Weinreb RN, Girkin CA, Berry CC, Zangwill LM. Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography. Ophthalmology. 2000;107:2278-2282.
-
(2000)
Ophthalmology.
, vol.107
, pp. 2278-2282
-
-
Blumenthal, E.Z.1
Williams, J.M.2
Weinreb, R.N.3
Girkin, C.A.4
Berry, C.C.5
Zangwill, L.M.6
-
17
-
-
33746426603
-
Influence of pupil size and cataract on retinal nerve fiber layer thickness measurements by Stratus OCT
-
Savini G, Zanini M, Barboni P. Influence of pupil size and cataract on retinal nerve fiber layer thickness measurements by Stratus OCT. J Glaucoma. 2006;15:336-340.
-
(2006)
J Glaucoma.
, vol.15
, pp. 336-340
-
-
Savini, G.1
Zanini, M.2
Barboni, P.3
-
18
-
-
58149128134
-
Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph
-
Vizzeri G, Bowd C, Medeiros FA, Weinreb RN, Zangwill LM. Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph. J Glaucoma. 2008;17:341-349.
-
(2008)
J Glaucoma.
, vol.17
, pp. 341-349
-
-
Vizzeri, G.1
Bowd, C.2
Medeiros, F.A.3
Weinreb, R.N.4
Zangwill, L.M.5
-
19
-
-
47249107711
-
Optical coherence tomography scan circle location and mean retinal nerve fiber layer measurement variability
-
Gabriele ML, Ishikawa H, Wollstein G, et al. Optical coherence tomography scan circle location and mean retinal nerve fiber layer measurement variability. Invest Ophthalmol Vis Sci. 2008;49:2315-2321.
-
(2008)
Invest Ophthalmol Vis Sci.
, vol.49
, pp. 2315-2321
-
-
Gabriele, M.L.1
Ishikawa, H.2
Wollstein, G.3
-
20
-
-
72449128550
-
Scan quality effect on glaucoma discrimination by glaucoma imaging devices
-
Sung KR, Wollstein G, Schuman JS, et al. Scan quality effect on glaucoma discrimination by glaucoma imaging devices. Br J Ophthalmol. 2009;93:1580-1584.
-
(2009)
Br J Ophthalmol.
, vol.93
, pp. 1580-1584
-
-
Sung, K.R.1
Wollstein, G.2
Schuman, J.S.3
-
21
-
-
67650461986
-
Effect of signal strength and improper alignment on the variability of stratus optical coherence tomography retinal nerve fiber layer thickness measurements
-
Vizzeri G, Bowd C, Medeiros FA, Weinreb RN, Zangwill LM. Effect of signal strength and improper alignment on the variability of stratus optical coherence tomography retinal nerve fiber layer thickness measurements. Am J Ophthalmol. 2009;148:249-255.
-
(2009)
Am J Ophthalmol.
, vol.148
, pp. 249-255
-
-
Vizzeri, G.1
Bowd, C.2
Medeiros, F.A.3
Weinreb, R.N.4
Zangwill, L.M.5
-
22
-
-
34249671717
-
Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT
-
Budenz DL, Anderson DR, Varma R, et al. Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT. Ophthalmology. 2007;114:1046-1052.
-
(2007)
Ophthalmology.
, vol.114
, pp. 1046-1052
-
-
Budenz, D.L.1
Anderson, D.R.2
Varma, R.3
-
24
-
-
79952697356
-
Topographic differences in the age-related changes in the retinal nerve fiber layer of normal eyes measured by stratus optical coherence tomography
-
Feuer WJ, Budenz DL, Anderson DR, et al. Topographic differences in the age-related changes in the retinal nerve fiber layer of normal eyes measured by stratus optical coherence tomography. J Glaucoma. 2010;20:133-138.
-
(2010)
J Glaucoma.
, vol.20
, pp. 133-138
-
-
Feuer, W.J.1
Budenz, D.L.2
Anderson, D.R.3
-
25
-
-
34248174858
-
Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study
-
Leung CK, Mohamed S, Leung KS, et al. Retinal nerve fiber layer measurements in myopia: an optical coherence tomography study. Invest Ophthalmol Vis Sci. 2006;47: 5171-5176.
-
(2006)
Invest Ophthalmol Vis Sci.
, vol.47
, pp. 5171-5176
-
-
Leung, C.K.1
Mohamed, S.2
Leung, K.S.3
-
26
-
-
33646130836
-
Retinal nerve fiber layer thickness in normal children measured with optical coherence tomography
-
Salchow DJ, Oleynikov YS, Chiang MF, et al. Retinal nerve fiber layer thickness in normal children measured with optical coherence tomography. Ophthalmology. 2006;113: 786-791.
-
(2006)
Ophthalmology.
, vol.113
, pp. 786-791
-
-
Salchow, D.J.1
Oleynikov, Y.S.2
Chiang, M.F.3
-
27
-
-
77955906560
-
Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography
-
Kang SH, Hong SW, Im SK, Lee SH, Ahn MD. Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography. Invest Ophthalmol Vis Sci. 2010;51:4075-4083.
-
(2010)
Invest Ophthalmol Vis Sci.
, vol.51
, pp. 4075-4083
-
-
Kang, S.H.1
Hong, S.W.2
Im, S.K.3
Lee, S.H.4
Ahn, M.D.5
-
28
-
-
84455181504
-
The influence of axial length on retinal nerve fibre layer thickness and opticdisc size measurements by spectral-domain OCT
-
Savini G, Barboni P, Parisi V, Carbonelli M. The influence of axial length on retinal nerve fibre layer thickness and opticdisc size measurements by spectral-domain OCT. Br J Ophthalmol. 2011;96:57-61.
-
(2011)
Br J Ophthalmol.
, vol.96
, pp. 57-61
-
-
Savini, G.1
Barboni, P.2
Parisi, V.3
Carbonelli, M.4
-
29
-
-
0034307708
-
Neuronal density in the human retinal ganglion cell layer from 16-77 years
-
Harman A, Abrahams B, Moore S, Hoskins R. Neuronal density in the human retinal ganglion cell layer from 16-77 years. Anat Rec. 2000;260:124-131.
-
(2000)
Anat Rec.
, vol.260
, pp. 124-131
-
-
Harman, A.1
Abrahams, B.2
Moore, S.3
Hoskins, R.4
-
30
-
-
0021266344
-
The effect of age on the nerve fiber population of the human optic nerve
-
Balazsi AG, Rootman J, Drance SM, Schulzer M, Douglas GR. The effect of age on the nerve fiber population of the human optic nerve. Am J Ophthalmol. 1984;97:760-766.
-
(1984)
Am J Ophthalmol.
, vol.97
, pp. 760-766
-
-
Balazsi, A.G.1
Rootman, J.2
Drance, S.M.3
Schulzer, M.4
Douglas, G.R.5
-
31
-
-
0024495094
-
The effect of age on normal human optic nerve fiber number and diameter
-
Repka MX, Quigley HA. The effect of age on normal human optic nerve fiber number and diameter. Ophthalmology. 1989;96:26-32.
-
(1989)
Ophthalmology.
, vol.96
, pp. 26-32
-
-
Repka, M.X.1
Quigley, H.A.2
-
33
-
-
33645796669
-
Retinal nerve fibre layer thickness profile in normal eyes using third-generation optical coherence tomography
-
Skaf M, Bernardes AB, Cardillo JA, et al. Retinal nerve fibre layer thickness profile in normal eyes using third-generation optical coherence tomography. Eye. 2006;20:431-439.
-
(2006)
Eye.
, vol.20
, pp. 431-439
-
-
Skaf, M.1
Bernardes, A.B.2
Cardillo, J.A.3
-
34
-
-
0030470612
-
Retinal nerve fiber layer thickness in normal human eyes
-
Varma R, Skaf M, Barron E. Retinal nerve fiber layer thickness in normal human eyes. Ophthalmology. 1996;103:2114-2119.
-
(1996)
Ophthalmology.
, vol.103
, pp. 2114-2119
-
-
Varma, R.1
Skaf, M.2
Barron, E.3
-
35
-
-
0025011140
-
Topography of ganglion cells in human retina
-
Curcio CA, Allen KA. Topography of ganglion cells in human retina. J Comp Neurol. 1990;300:5-25.
-
(1990)
J Comp Neurol.
, vol.300
, pp. 5-25
-
-
Curcio, C.A.1
Allen, K.A.2
-
36
-
-
0028334196
-
Improvements on Littmann's method of determining the size of retinal features by fundus photography
-
Bennett AG, Rudnicka AR, Edgar DF. Improvements on Littmann's method of determining the size of retinal features by fundus photography. Graefes Arch Clin Exp Ophthalmol. 1994;232:361-367.
-
(1994)
Graefes Arch Clin Exp Ophthalmol.
, vol.232
, pp. 361-367
-
-
Bennett, A.G.1
Rudnicka, A.R.2
Edgar, D.F.3
-
37
-
-
0020004188
-
Determination of the real size of an object on the fundus of the living eye
-
Littmann H. Determination of the real size of an object on the fundus of the living eye. Klin Monbl Augenheilkd. 1982;180: 286-289.
-
(1982)
Klin Monbl Augenheilkd.
, vol.180
, pp. 286-289
-
-
Littmann, H.1
-
38
-
-
0034979053
-
Influence of scan radius correction for ocular magnification and relationship between scan radius with retinal nerve fiber layer thickness measured by optical coherence tomography
-
Bayraktar S, Bayraktar Z, Yilmaz OF. Influence of scan radius correction for ocular magnification and relationship between scan radius with retinal nerve fiber layer thickness measured by optical coherence tomography. J Glaucoma. 2001;10: 163-169.
-
(2001)
J Glaucoma.
, vol.10
, pp. 163-169
-
-
Bayraktar, S.1
Bayraktar, Z.2
Yilmaz, O.F.3
-
39
-
-
79955942073
-
Effect of contact lens power on optical coherence tomography of the retinal nerve fiber layer
-
Salchow DJ, Hwang AM, Li FY, Dziura J. Effect of contact lens power on optical coherence tomography of the retinal nerve fiber layer. Invest Ophthalmol Vis Sci. 2011;52:1650-1654.
-
(2011)
Invest Ophthalmol Vis Sci.
, vol.52
, pp. 1650-1654
-
-
Salchow, D.J.1
Hwang, A.M.2
Li, F.Y.3
Dziura, J.4
-
40
-
-
80052114271
-
Negative refraction power causes underestimation of peripapillary retinal nerve fibre layer thickness in spectral-domain optical coherence tomography
-
Lee J, Kim NR, Kim H, et al. Negative refraction power causes underestimation of peripapillary retinal nerve fibre layer thickness in spectral-domain optical coherence tomography. Br J Ophthalmol. 2011;95:1284-1289.
-
(2011)
Br J Ophthalmol.
, vol.95
, pp. 1284-1289
-
-
Lee, J.1
Kim, N.R.2
Kim, H.3
-
41
-
-
0031778648
-
Measurement of optic disc size: Equivalence of methods to correct for ocular magnification
-
Garway-Heath DF, Rudnicka AR, Lowe T, Foster PJ, Fitzke FW, Hitchings RA. Measurement of optic disc size: equivalence of methods to correct for ocular magnification. Br J Ophthalmol. 1998;82:643-649.
-
(1998)
Br J Ophthalmol.
, vol.82
, pp. 643-649
-
-
Garway-Heath, D.F.1
Rudnicka, A.R.2
Lowe, T.3
Foster, P.J.4
Fitzke, F.W.5
Hitchings, R.A.6
-
42
-
-
0342864245
-
The schematic eye
-
In: Bennett AG, Rabbetts RB. eds. London, UK: Butterworths
-
Bennett AG, Rabbetts RB. The schematic eye. In: Bennett AG, Rabbetts RB. eds. Clinical Visual Optics. London, UK: Butterworths; 1989:249-274.
-
(1989)
Clinical Visual Optics.
, pp. 249-274
-
-
Bennett, A.G.1
Rabbetts, R.B.2
-
43
-
-
42649135119
-
Age-related changes in optical and biometric characteristics of emmetropic eyes
-
29.21-29.20
-
Atchison DA, Markwell EL, Kasthurirangan S, Pope JM, Smith G, Swann PG. Age-related changes in optical and biometric characteristics of emmetropic eyes. J Vis. 2008;8:29.21-29.20.
-
(2008)
J Vis.
, vol.8
-
-
Atchison, D.A.1
Markwell, E.L.2
Kasthurirangan, S.3
Pope, J.M.4
Smith, G.5
Swann, P.G.6
-
44
-
-
33847633883
-
Optical properties of ocular tissues in the near infrared region
-
Sardar DK, Swanland GY, Yow RM, Thomas RJ, Tsin AT. Optical properties of ocular tissues in the near infrared region. Lasers Med Sci. 2007;22:46-52.
-
(2007)
Lasers Med Sci.
, vol.22
, pp. 46-52
-
-
Sardar, D.K.1
Swanland, G.Y.2
Yow, R.M.3
Thomas, R.J.4
Tsin, A.T.5
-
45
-
-
79955996806
-
Retinal nerve fiber layer assessment: Area versus thickness measurements from elliptical scans centered on the optic nerve
-
Patel NB, Luo X, Wheat JL, Harwerth RS. Retinal nerve fiber layer assessment: area versus thickness measurements from elliptical scans centered on the optic nerve. Invest Ophthalmol Vis Sci. 2011;52:2477-2489.
-
(2011)
Invest Ophthalmol Vis Sci.
, vol.52
, pp. 2477-2489
-
-
Patel, N.B.1
Luo, X.2
Wheat, J.L.3
Harwerth, R.S.4
-
46
-
-
84861031282
-
Agreement between retinal nerve fiber layer measures from Spectralis and Cirrus spectral domain OCT
-
Patel NB, Wheat JL, Rodriguez A, Tran V, Harwerth RS. Agreement between retinal nerve fiber layer measures from Spectralis and Cirrus spectral domain OCT. Optom Vis Sci. 2011;89:E653-E666.
-
(2011)
Optom Vis Sci.
, vol.89
-
-
Patel, N.B.1
Wheat, J.L.2
Rodriguez, A.3
Tran, V.4
Harwerth, R.S.5
-
47
-
-
0345327826
-
The dual-bootstrap iterative closest point algorithm with application to retinal image registration
-
Stewart CV, Tsai CL, Roysam B. The dual-bootstrap iterative closest point algorithm with application to retinal image registration. IEEE Trans Med Imaging. 2003;22:1379-1394.
-
(2003)
IEEE Trans Med Imaging.
, vol.22
, pp. 1379-1394
-
-
Stewart, C.V.1
Tsai, C.L.2
Roysam, B.3
-
48
-
-
0030596840
-
Measurement error
-
Bland JM, Altman DG. Measurement error. BMJ. 1996;313: 744.
-
(1996)
BMJ.
, vol.313
, pp. 744
-
-
Bland, J.M.1
Altman, D.G.2
-
49
-
-
16244413197
-
Correlation between retinal nerve fibre layer thickness and optic nerve head size: An optical coherence tomography study
-
Savini G, Zanini M, Carelli V, Sadun AA, Ross-Cisneros FN, Barboni P. Correlation between retinal nerve fibre layer thickness and optic nerve head size: an optical coherence tomography study. Br J Ophthalmol. 2005;89:489-492.
-
(2005)
Br J Ophthalmol.
, vol.89
, pp. 489-492
-
-
Savini, G.1
Zanini, M.2
Carelli, V.3
Sadun, A.A.4
Ross-Cisneros, F.N.5
Barboni, P.6
-
50
-
-
33747881756
-
Peripapillary retinal nerve fiber layer thickness in a population of 6-yearold children: Findings by optical coherence tomography
-
Huynh SC, Wang XY, Rochtchina E, Mitchell P. Peripapillary retinal nerve fiber layer thickness in a population of 6-yearold children: findings by optical coherence tomography. Ophthalmology. 2006;113:1583-1592.
-
(2006)
Ophthalmology.
, vol.113
, pp. 1583-1592
-
-
Huynh, S.C.1
Wang, X.Y.2
Rochtchina, E.3
Mitchell, P.4
-
51
-
-
73349112275
-
Increased prevalence of myopia in the United States between 1971-1972 and 1999-2004
-
Vitale S, Sperduto RD, Ferris FL 3rd. Increased prevalence of myopia in the United States between 1971-1972 and 1999-2004. Arch Ophthalmol. 2009;127:1632-1639.
-
(2009)
Arch Ophthalmol.
, vol.127
, pp. 1632-1639
-
-
Vitale, S.1
Sperduto, R.D.2
Ferris III, F.L.3
-
52
-
-
84856596370
-
Refractive lens exchange versus phakic intraocular lenses
-
Nanavaty MA, Daya SM. Refractive lens exchange versus phakic intraocular lenses. Curr Opin Ophthalmol. 2012;23: 54-61.
-
(2012)
Curr Opin Ophthalmol.
, vol.23
, pp. 54-61
-
-
Nanavaty, M.A.1
Daya, S.M.2
-
53
-
-
49849095967
-
Advances in technologies for laser-assisted in situ keratomileusis (LASIK) surgery
-
Maldonado MJ, Nieto JC, Piñero DP. Advances in technologies for laser-assisted in situ keratomileusis (LASIK) surgery. Expert Rev Med Devices. 2008;5:209-229.
-
(2008)
Expert Rev Med Devices.
, vol.5
, pp. 209-229
-
-
Maldonado, M.J.1
Nieto, J.C.2
Piñero, D.P.3
-
54
-
-
77952075499
-
Laser in situ keratomileusis in 2010-a review
-
Sutton GL, Kim P. Laser in situ keratomileusis in 2010-a review. Clin Experiment Ophthalmol. 2010;38:192-210.
-
(2010)
Clin Experiment Ophthalmol.
, vol.38
, pp. 192-210
-
-
Sutton, G.L.1
Kim, P.2
-
55
-
-
84856599484
-
Intraocular lenses for presbyopia correction: Past, present, and future
-
Lichtinger A, Rootman DS. Intraocular lenses for presbyopia correction: past, present, and future. Curr Opin Ophthalmol. 2012;23:40-46.
-
(2012)
Curr Opin Ophthalmol.
, vol.23
, pp. 40-46
-
-
Lichtinger, A.1
Rootman, D.S.2
-
57
-
-
84873778481
-
Refraction and its components during the growth of the eye from the age of three
-
Special
-
Sorsby A, Benjamin B, Sheridan M, Stone J, Leary GA. Refraction and its components during the growth of the eye from the age of three. Memo Med Res Counc. 1961; 301(Special):1-67.
-
(1961)
Memo Med Res Counc.
, vol.301
, pp. 1-67
-
-
Sorsby, A.1
Benjamin, B.2
Sheridan, M.3
Stone, J.4
Leary, G.A.5
-
58
-
-
58149112405
-
Age-related paraxial schematic emmetropic eyes
-
Atchison DA. Age-related paraxial schematic emmetropic eyes. Ophthalmic Physiol Opt. 2009;29:58-64.
-
(2009)
Ophthalmic Physiol Opt.
, vol.29
, pp. 58-64
-
-
Atchison, D.A.1
-
59
-
-
67649311613
-
Comparison of retinal nerve fiber layer thickness measured by Cirrus HD and Stratus optical coherence tomography
-
Sung KR, Kim DY, Park SB, Kook MS. Comparison of retinal nerve fiber layer thickness measured by Cirrus HD and Stratus optical coherence tomography. Ophthalmology. 2009;116:1264-1270.
-
(2009)
Ophthalmology.
, vol.116
, pp. 1264-1270
-
-
Sung, K.R.1
Kim, D.Y.2
Park, S.B.3
Kook, M.S.4
-
60
-
-
67649311848
-
Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography
-
Knight OJ, Chang RT, Feuer WJ, Budenz DL. Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography. Ophthalmology. 2009;116:1271-1277.
-
(2009)
Ophthalmology.
, vol.116
, pp. 1271-1277
-
-
Knight, O.J.1
Chang, R.T.2
Feuer, W.J.3
Budenz, D.L.4
-
61
-
-
58149352680
-
Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography
-
Hood DC, Fortune B, Arthur SN, et al. Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography. J Glaucoma. 2008;17:519-528.
-
(2008)
J Glaucoma.
, vol.17
, pp. 519-528
-
-
Hood, D.C.1
Fortune, B.2
Arthur, S.N.3
|