-
1
-
-
77958542137
-
-
Eye Bank Association of America Eye Bank Association of America Washington DC 1-17
-
Eye Bank Association of America 2009 Eye Banking Statistical Report 2010 Eye Bank Association of America Washington DC 1-17
-
(2010)
2009 Eye Banking Statistical Report
-
-
-
2
-
-
84871019989
-
Eye Health Statistics at a Glance
-
American Academy of Ophthalmology Available at: Accessed August 20, 2012
-
American Academy of Ophthalmology Eye Health Statistics at a Glance Am Academy Ophthalmol 2009 Available at: http://www.aao.org/newsroom/press-kit/ upload/Eye-Health-Statistics-June-2009.pdf Accessed August 20, 2012
-
(2009)
Am Academy Ophthalmol
-
-
-
3
-
-
13844317418
-
Corneal flap thickness and topography changes induced by flap creation during laser in situ keratomileusis
-
J.L. Güell, F. Velasco, C. Roberts, M.T. Sisquella, and A. Mahmoud Corneal flap thickness and topography changes induced by flap creation during laser in situ keratomileusis J Cataract Refract Surg 31 2005 115 119
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 115-119
-
-
Güell, J.L.1
Velasco, F.2
Roberts, C.3
Sisquella, M.T.4
Mahmoud, A.5
-
4
-
-
0036189248
-
Spot size and quality of scanning laser correction of higher-order wavefront aberrations
-
D. Huang, and M. Arif Spot size and quality of scanning laser correction of higher-order wavefront aberrations J Cataract Refract Surg 28 2002 407 416
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 407-416
-
-
Huang, D.1
Arif, M.2
-
5
-
-
33646169244
-
Comparison of the IntraLase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis
-
T. Lim, S. Yang, M.J. Kim, and H. Tchah Comparison of the IntraLase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis Am J Ophthalmol 141 2006 833 839
-
(2006)
Am J Ophthalmol
, vol.141
, pp. 833-839
-
-
Lim, T.1
Yang, S.2
Kim, M.J.3
Tchah, H.4
-
6
-
-
13844305846
-
Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes; Potential impact on wavefront-guided laser in situ keratomileusis
-
D.B. Tran, M.A. Sarayba, Z. Bor, C. Garufis, Y.-J. Duh, C.R. Soltes, T. Juhasz, and R.M. Kurtz Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes; potential impact on wavefront-guided laser in situ keratomileusis J Cataract Refract Surg 31 2005 97 105
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 97-105
-
-
Tran, D.B.1
Sarayba, M.A.2
Bor, Z.3
Garufis, C.4
Duh, Y.-J.5
Soltes, C.R.6
Juhasz, T.7
Kurtz, R.M.8
-
7
-
-
0031923091
-
Effect of decreasing surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis on optical and functional outcomes
-
P. Vinciguerra, M. Azzolini, P. Airaghi, P. Radice, and V. De Molfetta Effect of decreasing surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis on optical and functional outcomes J Refract Surg 14 1998 S199 S203
-
(1998)
J Refract Surg
, vol.14
-
-
Vinciguerra, P.1
Azzolini, M.2
Airaghi, P.3
Radice, P.4
De Molfetta, V.5
-
8
-
-
34247625520
-
Comparative study of stromal bed quality by using mechanical, IntraLase femtosecond laser 15- and 30-kHz microkeratomes
-
M.A. Sarayba, T.S. Ignacio, P.S. Binder, and D.B. Tran Comparative study of stromal bed quality by using mechanical, IntraLase femtosecond laser 15- and 30-kHz microkeratomes Cornea 26 2007 446 451
-
(2007)
Cornea
, vol.26
, pp. 446-451
-
-
Sarayba, M.A.1
Ignacio, T.S.2
Binder, P.S.3
Tran, D.B.4
-
9
-
-
33846329793
-
Femtosecond laser keratome creation of partial thickness donor corneal buttons for lamellar keratoplasty
-
M.A. Sarayba, E. Maguen, J. Salz, Y. Rabinowitz, and T.S. Ignacio Femtosecond laser keratome creation of partial thickness donor corneal buttons for lamellar keratoplasty J Refract Surg 23 2007 58 65
-
(2007)
J Refract Surg
, vol.23
, pp. 58-65
-
-
Sarayba, M.A.1
Maguen, E.2
Salz, J.3
Rabinowitz, Y.4
Ignacio, T.S.5
-
10
-
-
69649109390
-
Histologic and ultrastructural characterization of corneal femtosecond laser trephination
-
V. Nuzzo, F. Aptel, M. Savoldelli, K. Plamann, D. Peyrot, F. Deloison, D. Donate, and J.-M. Legeais Histologic and ultrastructural characterization of corneal femtosecond laser trephination Cornea 28 2009 908 913
-
(2009)
Cornea
, vol.28
, pp. 908-913
-
-
Nuzzo, V.1
Aptel, F.2
Savoldelli, M.3
Plamann, K.4
Peyrot, D.5
Deloison, F.6
Donate, D.7
Legeais, J.-M.8
-
11
-
-
40449128291
-
Comparison of the femtosecond laser (IntraLase) versus manual microkeratome (Moria ALTK) in dissection of the donor in endothelial keratoplasty; Initial study in eye bank eyes
-
Y.J. Jones, K.M. Goins, J.E. Sutphin, R. Mullins, and J.M. Skeie Comparison of the femtosecond laser (IntraLase) versus manual microkeratome (Moria ALTK) in dissection of the donor in endothelial keratoplasty; initial study in eye bank eyes Cornea 27 2008 88 93
-
(2008)
Cornea
, vol.27
, pp. 88-93
-
-
Jones, Y.J.1
Goins, K.M.2
Sutphin, J.E.3
Mullins, R.4
Skeie, J.M.5
-
12
-
-
62149135774
-
Histologic evaluation of human posterior lamellar discs for femtosecond laser Descemet's stripping endothelial keratoplasty
-
Y.Y.Y. Cheng, S.J. Kang, H.E. Grossniklaus, E. Pels, H.J.Q. Duimel, P.M. Frederik, F. Hendrikse, and R.M.M.A. Nuijts Histologic evaluation of human posterior lamellar discs for femtosecond laser Descemet's stripping endothelial keratoplasty Cornea 28 2009 73 79
-
(2009)
Cornea
, vol.28
, pp. 73-79
-
-
Cheng, Y.Y.Y.1
Kang, S.J.2
Grossniklaus, H.E.3
Pels, E.4
Duimel, H.J.Q.5
Frederik, P.M.6
Hendrikse, F.7
Nuijts, R.M.M.A.8
-
13
-
-
77349093827
-
Effect of varying microkeratome parameters on laser in situ keratomileusis interface surfaces
-
R.K. Sanka, E.S. Loft, and J.B. Randleman Effect of varying microkeratome parameters on laser in situ keratomileusis interface surfaces J Cataract Refract Surg 36 2010 493 496
-
(2010)
J Cataract Refract Surg
, vol.36
, pp. 493-496
-
-
Sanka, R.K.1
Loft, E.S.2
Randleman, J.B.3
-
14
-
-
0033732188
-
Cut edges and surface characteristics produced by different microkeratomes
-
F.W. Wilhelm, T. Giessmann, R. Hanschke, G.I. Duncker, and L.H. Wilhelm Cut edges and surface characteristics produced by different microkeratomes J Refract Surg 16 2000 690 700
-
(2000)
J Refract Surg
, vol.16
, pp. 690-700
-
-
Wilhelm, F.W.1
Giessmann, T.2
Hanschke, R.3
Duncker, G.I.4
Wilhelm, L.H.5
-
15
-
-
80052718969
-
Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters
-
K.S. Kunert, M. Blum, G.I. Duncker, R. Sietmann, and J. Heichel Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters Graefes Arch Clin Exp Ophthalmol 249 2011 1417 1424
-
(2011)
Graefes Arch Clin Exp Ophthalmol
, vol.249
, pp. 1417-1424
-
-
Kunert, K.S.1
Blum, M.2
Duncker, G.I.3
Sietmann, R.4
Heichel, J.5
-
16
-
-
79751527489
-
Surface quality of porcine corneal lenticules after femtosecond lenticule extraction
-
J. Heichel, M. Blum, G.I.W. Duncker, R. Sietmann, and K.S. Kunert Surface quality of porcine corneal lenticules after femtosecond lenticule extraction Ophthalmic Res 46 2011 107 112
-
(2011)
Ophthalmic Res
, vol.46
, pp. 107-112
-
-
Heichel, J.1
Blum, M.2
Duncker, G.I.W.3
Sietmann, R.4
Kunert, K.S.5
-
17
-
-
47949120544
-
Femtosecond laser-assisted endothelial keratoplasty; A laboratory model
-
J.S. Mehta, A. Parthasarthy, Y.-M. Por, H. Cajucom-Uy, R.W. Beuerman, and D. Tan Femtosecond laser-assisted endothelial keratoplasty; a laboratory model Cornea 27 2008 706 712
-
(2008)
Cornea
, vol.27
, pp. 706-712
-
-
Mehta, J.S.1
Parthasarthy, A.2
Por, Y.-M.3
Cajucom-Uy, H.4
Beuerman, R.W.5
Tan, D.6
-
18
-
-
25144499497
-
Evaluation of four microkeratome models: Quality and reproducibility of cut edge and cut surface as determined by scanning electron microscopy
-
T. Hammer, R. Hanschke, I. Wörner, and F.W. Wilhelm Evaluation of four microkeratome models: quality and reproducibility of cut edge and cut surface as determined by scanning electron microscopy J Refract Surg 21 2005 454 462
-
(2005)
J Refract Surg
, vol.21
, pp. 454-462
-
-
Hammer, T.1
Hanschke, R.2
Wörner, I.3
Wilhelm, F.W.4
-
19
-
-
47949116090
-
Corneal stromal bed quality obtained with mechanical microkeratome and femtosecond laser
-
[letter] reply by T Ignacio, 746-747
-
S. Srinivasan, and D. Holmyard Corneal stromal bed quality obtained with mechanical microkeratome and femtosecond laser [letter] Cornea 27 2008 746 reply by T Ignacio, 746-747
-
(2008)
Cornea
, vol.27
, pp. 746
-
-
Srinivasan, S.1
Holmyard, D.2
-
20
-
-
34247226738
-
A 60 kHz IntraLase femtosecond laser creates a smoother LASIK stromal bed surface compared to a Zyoptix XP mechanical microkeratome in human donor eyes
-
M.A. Sarayba, T.S. Ignacio, D.B. Tran, and P.S. Binder A 60 kHz IntraLase femtosecond laser creates a smoother LASIK stromal bed surface compared to a Zyoptix XP mechanical microkeratome in human donor eyes J Refract Surg 23 2007 331 337
-
(2007)
J Refract Surg
, vol.23
, pp. 331-337
-
-
Sarayba, M.A.1
Ignacio, T.S.2
Tran, D.B.3
Binder, P.S.4
-
21
-
-
0041820243
-
Imaging guidelines for scanning electron microscopy
-
Available at: Accessed August 20, 2012
-
T. Laudate Imaging guidelines for scanning electron microscopy Advanced Materials & Processes 161 7 2003 23 25 Available at: http://www.google.com/ url?sa=t&rct=j&q= imaging%20guidelines%20for%20scanning%20electron%20microscopy&source= web&cd=1&ved=0CGEQFjAA&url=http%3A%2F%2Fwww.jeolusa. com%2FDesktopModules%2FBring2mind%2FDMX%2FDownload. aspx%3FEntryId%3D614%26PortalId%3D2%26DownloadMethod%3Dattachment&ei= agQyUO32EIa69gS6iICwBg&usg=AFQjCNEhQkxcOWe986DJ01ltBoOctMm9uw Accessed August 20, 2012
-
(2003)
Advanced Materials & Processes
, vol.161
, Issue.7
, pp. 23-25
-
-
Laudate, T.1
-
22
-
-
0015680481
-
Textural features for image classification
-
Available at: Accessed August 20, 2012
-
R.M. Haralick, K. Shanmugam, and I. Dinstein Textural features for image classification IEEE Trans Systems Man Cybernetics SMC-3 1973 610 621 Available at: http://dceanalysis.bigr.nl/Haralick73- Textural%20features%20for%20image%20classification.pdf Accessed August 20, 2012
-
(1973)
IEEE Trans Systems Man Cybernetics
, vol.3 SMC-
, pp. 610-621
-
-
Haralick, R.M.1
Shanmugam, K.2
Dinstein, I.3
-
23
-
-
0032907908
-
Evaluation of corneal flap dimensions and cut quality using a manually guided microkeratome
-
errata, 400
-
A. Behrens, B. Seitz, A. Langenbucher, M.M. Kus, C. Rummelt, and M. Küchle Evaluation of corneal flap dimensions and cut quality using a manually guided microkeratome J Refract Surg 15 1999 118 123 errata, 400
-
(1999)
J Refract Surg
, vol.15
, pp. 118-123
-
-
Behrens, A.1
Seitz, B.2
Langenbucher, A.3
Kus, M.M.4
Rummelt, C.5
Küchle, M.6
-
24
-
-
84871008405
-
-
Université de Montréal, Département d'Informatique et de Recherche Opérationnelle Montreal, Quebec, Canada Technical Report number 1361
-
S. Roy, J. Meunier, A.M. Marian, O. Nada, F. Légaré, F. Vidal, I. Brunette, and S. Costantino Automatic 3D reconstruction of quasi-planar stereo SEM images 2011 Université de Montréal, Département d'Informatique et de Recherche Opérationnelle Montreal, Quebec, Canada Technical Report number 1361
-
(2011)
Automatic 3D Reconstruction of Quasi-planar Stereo SEM Images
-
-
Roy, S.1
Meunier, J.2
Marian, A.M.3
Nada, O.4
Légaré, F.5
Vidal, F.6
Brunette, I.7
Costantino, S.8
-
25
-
-
33644866417
-
Measuring surface topography with scanning electron microscopy. I. EZElmage: A program to obtain 3D surface data
-
E. Ponz, J.L. Ladaga, and R.D. Bonetto Measuring surface topography with scanning electron microscopy. I. EZElmage: a program to obtain 3D surface data Microsc Microanal 12 2006 170 177
-
(2006)
Microsc Microanal
, vol.12
, pp. 170-177
-
-
Ponz, E.1
Ladaga, J.L.2
Bonetto, R.D.3
-
26
-
-
24644470637
-
Accurate and efficient stereo processing by semi-global matching and mutual information
-
Available at:. Accessed August 20, 2012
-
Hirschmüller H. Accurate and efficient stereo processing by semi-global matching and mutual information. IEEE Computer Society Conference on Computer Vision and Pattern Recognition 2005; 807-814. Available at: http://www.dlr.de/rm/en/PortalData/3/Resources/papers/modeler/cvpr05hh.pdf. Accessed August 20, 2012
-
(2005)
IEEE Computer Society Conference on Computer Vision and Pattern Recognition
, pp. 807-814
-
-
Hirschmüller, H.1
-
27
-
-
0019723804
-
A theory of preattentive texture discrimination based on first-order statistics of textons
-
B. Julesz A theory of preattentive texture discrimination based on first-order statistics of textons Biol Cybern 41 1981 131 138
-
(1981)
Biol Cybern
, vol.41
, pp. 131-138
-
-
Julesz, B.1
-
28
-
-
0016939601
-
Comparative-study of texture measures for terrain classification
-
J.S. Weszka, C.R. Dyer, and A. Rosenfeld Comparative-study of texture measures for terrain classification IEEE Trans Syst Man Cybern SMC-6 1976 269 285
-
(1976)
IEEE Trans Syst Man Cybern
, vol.6 SMC-
, pp. 269-285
-
-
Weszka, J.S.1
Dyer, C.R.2
Rosenfeld, A.3
-
30
-
-
66349090522
-
Statistical nuclear texture analysis in cancer research: A review of methods and applications
-
B. Nielsen, F. Albregtsen, and H.E. Danielsen Statistical nuclear texture analysis in cancer research: a review of methods and applications Crit Rev Oncog 14 2008 89 164
-
(2008)
Crit Rev Oncog
, vol.14
, pp. 89-164
-
-
Nielsen, B.1
Albregtsen, F.2
Danielsen, H.E.3
-
31
-
-
77952407905
-
Texture analysis: A review of neurologic MR imaging applications
-
A. Kassner, and R.E. Thornhill Texture analysis: a review of neurologic MR imaging applications Am J Neuroradiol 31 2010 809 816
-
(2010)
Am J Neuroradiol
, vol.31
, pp. 809-816
-
-
Kassner, A.1
Thornhill, R.E.2
-
32
-
-
77952597389
-
Protein classification using texture descriptors extracted from the protein backbone image
-
L. Nanni, J.-Y. Shi, S. Brahnam, and A. Lumini Protein classification using texture descriptors extracted from the protein backbone image J Theor Biol 264 2010 1024 1032
-
(2010)
J Theor Biol
, vol.264
, pp. 1024-1032
-
-
Nanni, L.1
Shi, J.-Y.2
Brahnam, S.3
Lumini, A.4
-
33
-
-
75949108990
-
Quantitative measurement of aging using image texture entropy
-
Available at: Accessed August 20, 2012
-
L. Shamir, C.A. Wolkow, and I.G. Goldberg Quantitative measurement of aging using image texture entropy Bioinformatics 25 2009 3060 3063 Available at: http://bioinformatics.oxfordjournals.org/content/25/23/3060.full.pdf Accessed August 20, 2012
-
(2009)
Bioinformatics
, vol.25
, pp. 3060-3063
-
-
Shamir, L.1
Wolkow, C.A.2
Goldberg, I.G.3
-
34
-
-
34547650901
-
A multiresolution approach to automated classification of protein subcellular location images
-
Available at: Accessed August 20, 2012
-
A. Chebira, Y. Barbotin, C. Jackson, T. Merryman, G. Srinivasa, R.F. Murphy, and J. Kovačević A multiresolution approach to automated classification of protein subcellular location images BMC Bioinformatics 8 2007 210 Available at: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1933440/pdf/1471- 2105-8-210.pdf Accessed August 20, 2012
-
(2007)
BMC Bioinformatics
, vol.8
, pp. 210
-
-
Chebira, A.1
Barbotin, Y.2
Jackson, C.3
Merryman, T.4
Srinivasa, G.5
Murphy, R.F.6
Kovačević, J.7
-
35
-
-
34147187876
-
Fast automated cell phenotype image classification
-
Available at: Accessed August 20, 2012
-
N.A. Hamilton, R.S. Pantelic, K. Hanson, and R.D. Teasdale Fast automated cell phenotype image classification BMC Bioinformatics 8 2007 110 Available at: http://www.biomedcentral.com/content/pdf/1471-2105-8-110.pdf Accessed August 20, 2012
-
(2007)
BMC Bioinformatics
, vol.8
, pp. 110
-
-
Hamilton, N.A.1
Pantelic, R.S.2
Hanson, K.3
Teasdale, R.D.4
-
36
-
-
0029273845
-
An investigation of the textural characteristics associated with gray-level cooccurrence matrix statistical parameters
-
A. Baraldi, and F. Parmiggiani An investigation of the textural characteristics associated with gray-level cooccurrence matrix statistical parameters IEEE Trans Geosci Remote Sens 33 1995 293 304
-
(1995)
IEEE Trans Geosci Remote Sens
, vol.33
, pp. 293-304
-
-
Baraldi, A.1
Parmiggiani, F.2
-
37
-
-
0033836997
-
Atomic force microscopic study of the human cornea following excimer laser keratectomy
-
A. Nógrádi, B. Hopp, K. Révész, G. Szabó, Z. Bor, and L. Kolozsvari Atomic force microscopic study of the human cornea following excimer laser keratectomy Exp Eye Res 70 2000 363 368
-
(2000)
Exp Eye Res
, vol.70
, pp. 363-368
-
-
Nógrádi, A.1
Hopp, B.2
Révész, K.3
Szabó, G.4
Bor, Z.5
Kolozsvari, L.6
-
38
-
-
0036382171
-
Excimer laser ablated cornea observed by atomic force microscopy
-
S. Lydataki, E. Lesniewska, M.K. Tsilimbaris, S. Panagopoulou, C. Le Grimellec, and I.G. Pallikaris Excimer laser ablated cornea observed by atomic force microscopy Single Mol 3 2002 141 147
-
(2002)
Single Mol
, vol.3
, pp. 141-147
-
-
Lydataki, S.1
Lesniewska, E.2
Tsilimbaris, M.K.3
Panagopoulou, S.4
Le Grimellec, C.5
Pallikaris, I.G.6
-
39
-
-
33749074054
-
Atomic force microscopy analysis of normal and photoablated porcine corneas
-
Available at: Accessed August 20, 2012
-
M. Lombardo, M.P. De Santo, G. Lombardo, R. Barberi, and S. Serrao Atomic force microscopy analysis of normal and photoablated porcine corneas J Biomech 39 2006 2719 2724 Available at: http://www.visioeng.it/documents/ AFMJBiomechanics.pdf Accessed August 20, 2012
-
(2006)
J Biomech
, vol.39
, pp. 2719-2724
-
-
Lombardo, M.1
De Santo, M.P.2
Lombardo, G.3
Barberi, R.4
Serrao, S.5
-
40
-
-
84870251080
-
Surface quality of femtosecond dissected posterior human corneal stroma investigated with atomic force microscopy
-
[Epub ahead of print]
-
M. Lombardo, M.P. De Santo, G. Lombardo, D.S. Lomoriello, G. Desiderio, P. Ducoli, R. Barberi, and S. Serrao Surface quality of femtosecond dissected posterior human corneal stroma investigated with atomic force microscopy Cornea 2012 May 29 [Epub ahead of print]
-
(2012)
Cornea
-
-
Lombardo, M.1
De Santo, M.P.2
Lombardo, G.3
Lomoriello, D.S.4
Desiderio, G.5
Ducoli, P.6
Barberi, R.7
Serrao, S.8
-
41
-
-
2942707931
-
Wide band interferometry for thickness measurement
-
Available at: Accessed August 20, 2012
-
S. Costantino, O.E. Martínez, and J.R. Torga Wide band interferometry for thickness measurement Opt Express 11 2003 952 957 Available at: http://www.lec.df.uba.ar/administrator/components/com-jresearch/files/ publications/costantino-2003.pdf Accessed August 20, 2012
-
(2003)
Opt Express
, vol.11
, pp. 952-957
-
-
Costantino, S.1
Martínez, O.E.2
Torga, J.R.3
-
42
-
-
77953355922
-
Development of a novel instrument to measure the pulsatile movement of ocular tissues
-
K. Singh, C. Dion, S. Costantino, M. Wajszilber, M.R. Lesk, and T. Ozaki Development of a novel instrument to measure the pulsatile movement of ocular tissues Exp Eye Res 91 2010 63 68
-
(2010)
Exp Eye Res
, vol.91
, pp. 63-68
-
-
Singh, K.1
Dion, C.2
Costantino, S.3
Wajszilber, M.4
Lesk, M.R.5
Ozaki, T.6
-
44
-
-
0032613799
-
In vivo ultrahigh-resolution optical coherence tomography
-
Available at: Accessed August 20, 2012
-
W. Drexler, F.X. Kärtner, C. Pitris, S.A. Boppart, X.D. Li, E.P. Ippen, and J.G. Fujimoto In vivo ultrahigh-resolution optical coherence tomography Opt Lett 24 1999 1221 1223 Available at: http://www.uta.edu/rfmems/N- 041101/Reference/85.pdf Accessed August 20, 2012
-
(1999)
Opt Lett
, vol.24
, pp. 1221-1223
-
-
Drexler, W.1
Kärtner, F.X.2
Pitris, C.3
Boppart, S.A.4
Li, X.D.5
Ippen, E.P.6
Fujimoto, J.G.7
|