1
-
-
67649826762
-
Clinical biomechanics of third body acceleration of total Hip wear
-
Brown T., Lundberg H., Penderson D., et al. Clinical biomechanics of third body acceleration of total Hip wear. Clin Orthop Relat Res 2009, 467:1885.
-
(2009)
Clin Orthop Relat Res
, vol.467
, pp. 1885
-
-
Brown, T.1
Lundberg, H.2
Penderson, D.3
-
2
-
-
0031664878
-
Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report
-
Allain J., Goutallier D., Voisin M., et al. Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report. J Bone Joint Surg Am 1998, 80:1355.
-
(1998)
J Bone Joint Surg Am
, vol.80
, pp. 1355
-
-
Allain, J.1
Goutallier, D.2
Voisin, M.3
-
3
-
-
0024992964
-
Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball
-
Kempf I., Semlitsch M. Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Arch Orthop Trauma Surg 1990, 109:284.
-
(1990)
Arch Orthop Trauma Surg
, vol.109
, pp. 284
-
-
Kempf, I.1
Semlitsch, M.2
-
4
-
-
0344062979
-
Fracture de tête céramique: conduite à tenir
-
Vielpeau C., Hulet C., Pages C., et al. Fracture de tête céramique: conduite à tenir. Ann Orthop Ouest 1997, 29:75.
-
(1997)
Ann Orthop Ouest
, vol.29
, pp. 75
-
-
Vielpeau, C.1
Hulet, C.2
Pages, C.3
-
5
-
-
67650714174
-
Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty
-
Oldenburg M., Wegner R., Baur X. Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty. J Arthroplasty 2009, 24:825.e15.
-
(2009)
J Arthroplasty
, vol.24
-
-
Oldenburg, M.1
Wegner, R.2
Baur, X.3
-
6
-
-
0038005468
-
Massive metallosis after revision of a fractured ceramic head onto a metal head
-
Matziolis G., Perka C., Disch A. Massive metallosis after revision of a fractured ceramic head onto a metal head. Arch Orthop Trauma Surg 2003, 123:48.
-
(2003)
Arch Orthop Trauma Surg
, vol.123
, pp. 48
-
-
Matziolis, G.1
Perka, C.2
Disch, A.3
-
7
-
-
0037657959
-
Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study
-
Allain J., Roudot-Thoraval F., Delecrin J., et al. Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg Am 2003, 85-A:825.
-
(2003)
J Bone Joint Surg Am
, pp. 825
-
-
Allain, J.1
Roudot-Thoraval, F.2
Delecrin, J.3
-
8
-
-
78649835865
-
Arthroprosthetic cobaltism: neurological and cardiac manifestations in Two patients with metal-on-metal arthroplasty: a case report
-
Tower S. Arthroprosthetic cobaltism: neurological and cardiac manifestations in Two patients with metal-on-metal arthroplasty: a case report. J Bone Joint Surg Am 2010, 92A:5.
-
(2010)
J Bone Joint Surg Am
, vol.92 A
, pp. 5
-
-
Tower, S.1
-
9
-
-
0041317170
-
Comparison of cross-linked polyethylene materials for orthopaedic applications
-
Collier J., Currier B., Kennedy F., et al. Comparison of cross-linked polyethylene materials for orthopaedic applications. Clin Orthop Relat Res 2003, 414:289.
-
(2003)
Clin Orthop Relat Res
, vol.414
, pp. 289
-
-
Collier, J.1
Currier, B.2
Kennedy, F.3
-
10
-
-
0041420955
-
Third-body wear of highly cross-linked polyethylene in a hip simulator
-
Bragdon C., Jasty M., Muratoglu O., et al. Third-body wear of highly cross-linked polyethylene in a hip simulator. J Arthroplasty 2003, 18:553.
-
(2003)
J Arthroplasty
, vol.18
, pp. 553
-
-
Bragdon, C.1
Jasty, M.2
Muratoglu, O.3
-
11
-
-
78649323060
-
Is there a risk in placing a ceramic head on a previously implanted trunion?
-
Hannouche D., Delambre J., Zadegan F., et al. Is there a risk in placing a ceramic head on a previously implanted trunion?. Clin Orthop Relat Res 2010, 1.
-
(2010)
Clin Orthop Relat Res
, pp. 1
-
-
Hannouche, D.1
Delambre, J.2
Zadegan, F.3
-
12
-
-
0029558228
-
Fracture of an alumina ceramic head in total hip arthroplasty
-
Higuchi F., Shiba N., Inoue A., et al. Fracture of an alumina ceramic head in total hip arthroplasty. J Arthroplasty 1995, 10:851.
-
(1995)
J Arthroplasty
, vol.10
, pp. 851
-
-
Higuchi, F.1
Shiba, N.2
Inoue, A.3
-
13
-
-
4644234883
-
Zirconia femoral head fractures: a clinical and retrieval analysis
-
Masonis J., Bourne R., Ries M., et al. Zirconia femoral head fractures: a clinical and retrieval analysis. J Arthroplasty 2004, 19:898.
-
(2004)
J Arthroplasty
, vol.19
, pp. 898
-
-
Masonis, J.1
Bourne, R.2
Ries, M.3
-
14
-
-
38949161946
-
Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. Boston, MA
-
Koo K., Ha Y., Woon H., et al. Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. Boston, MA. J Bone Joint Surg Am 2008.
-
(2008)
J Bone Joint Surg Am
-
-
Koo, K.1
Ha, Y.2
Woon, H.3
-
15
-
-
0345491958
-
Fractures of ceramic bearings: history and present status
-
Hannouche D., Nich C., Bizot P., et al. Fractures of ceramic bearings: history and present status. Clin Orthop Relat Res 2003, 417:19.
-
(2003)
Clin Orthop Relat Res
, vol.417
, pp. 19
-
-
Hannouche, D.1
Nich, C.2
Bizot, P.3
-
17
-
-
33645658517
-
Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. Boston, MA
-
Park Y.-S., Hwang S.-K., Choy W.-S., et al. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. Boston, MA. J Bone Joint Surg Am 2006.
-
(2006)
J Bone Joint Surg Am
-
-
Park, Y.-S.1
Hwang, S.-K.2
Choy, W.-S.3
-
18
-
-
34247847840
-
Ceramic liner fracture after cementless alumina-on-alumina total Hip arthroplasty
-
Ha Y.-C., Kim S.-Y., Kim H.J., et al. Ceramic liner fracture after cementless alumina-on-alumina total Hip arthroplasty. Clin Orthop Relat Res 2007, 458:106.
-
(2007)
Clin Orthop Relat Res
, vol.458
, pp. 106
-
-
Ha, Y.-C.1
Kim, S.-Y.2
Kim, H.J.3
-
19
-
-
68749104638
-
Clinical fracture of cross-linked UHMWPE acetabular liners
-
Furmanski J., Anderson M., Bal S., et al. Clinical fracture of cross-linked UHMWPE acetabular liners. Biomaterials 2009, 30:5572.
-
(2009)
Biomaterials
, vol.30
, pp. 5572
-
-
Furmanski, J.1
Anderson, M.2
Bal, S.3
-
20
-
-
1842473877
-
Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report
-
Halley D., Glassman A., Crowninshield R. Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report. J Bone Joint Surg Am 2004, 86:827.
-
(2004)
J Bone Joint Surg Am
, vol.86
, pp. 827
-
-
Halley, D.1
Glassman, A.2
Crowninshield, R.3
-
21
-
-
35349019671
-
Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty
-
Tower S., Currier J., Currier B., et al. Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am 2007, 89:2212.
-
(2007)
J Bone Joint Surg Am
, vol.89
, pp. 2212
-
-
Tower, S.1
Currier, J.2
Currier, B.3
-
22
-
-
76249109227
-
THA with delta ceramic on ceramic: results of a multicenter investigational device exemption trial
-
Hamilton W., McAuley J., Dennis D., et al. THA with delta ceramic on ceramic: results of a multicenter investigational device exemption trial. Clin Orthop Relat Res 2010, 468:358.
-
(2010)
Clin Orthop Relat Res
, vol.468
, pp. 358
-
-
Hamilton, W.1
McAuley, J.2
Dennis, D.3
-
23
-
-
61449099441
-
Ceramic materials as bearing surfaces for total hip arthroplasty
-
D'Antonio J., Sutton K. Ceramic materials as bearing surfaces for total hip arthroplasty. J Am Acad Orthop Surg 2009, 17:63.
-
(2009)
J Am Acad Orthop Surg
, vol.17
, pp. 63
-
-
D'Antonio, J.1
Sutton, K.2
-
24
-
-
76249129686
-
Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis
-
Lombardi A., Berend K., Seng B., et al. Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis. Clin Orthop Relat Res 2010, 468:367.
-
(2010)
Clin Orthop Relat Res
, vol.468
, pp. 367
-
-
Lombardi, A.1
Berend, K.2
Seng, B.3
-
25
-
-
72349090736
-
Metal release and corrosion effects of modular neck total hip arthroplasty
-
Kretzer J., Jakubowitz E., Krachler M., et al. Metal release and corrosion effects of modular neck total hip arthroplasty. Int Orthop 2009, 33:1531.
-
(2009)
Int Orthop
, vol.33
, pp. 1531
-
-
Kretzer, J.1
Jakubowitz, E.2
Krachler, M.3
-
26
-
-
0031940455
-
Ceramics for total hip replacement-what a surgeon should know
-
Willmann G. Ceramics for total hip replacement-what a surgeon should know. Orthopedics 1998, 21:173.
-
(1998)
Orthopedics
, vol.21
, pp. 173
-
-
Willmann, G.1
|