메뉴 건너뛰기




Volumn 28, Issue 1, 2013, Pages 197.e17-197.e21

Abrasive Wear and Metallosis Associated With Cross-Linked Polyethylene in Total Hip Arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY; CHROMIUM; COBALT; POLYETHYLENE; TITANIUM;

EID: 84870758406     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2012.05.014     Document Type: Article
Times cited : (9)

References (26)
  • 1
    • 67649826762 scopus 로고    scopus 로고
    • Clinical biomechanics of third body acceleration of total Hip wear
    • Brown T., Lundberg H., Penderson D., et al. Clinical biomechanics of third body acceleration of total Hip wear. Clin Orthop Relat Res 2009, 467:1885.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 1885
    • Brown, T.1    Lundberg, H.2    Penderson, D.3
  • 2
    • 0031664878 scopus 로고    scopus 로고
    • Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report
    • Allain J., Goutallier D., Voisin M., et al. Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report. J Bone Joint Surg Am 1998, 80:1355.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1355
    • Allain, J.1    Goutallier, D.2    Voisin, M.3
  • 3
    • 0024992964 scopus 로고
    • Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball
    • Kempf I., Semlitsch M. Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Arch Orthop Trauma Surg 1990, 109:284.
    • (1990) Arch Orthop Trauma Surg , vol.109 , pp. 284
    • Kempf, I.1    Semlitsch, M.2
  • 4
    • 0344062979 scopus 로고    scopus 로고
    • Fracture de tête céramique: conduite à tenir
    • Vielpeau C., Hulet C., Pages C., et al. Fracture de tête céramique: conduite à tenir. Ann Orthop Ouest 1997, 29:75.
    • (1997) Ann Orthop Ouest , vol.29 , pp. 75
    • Vielpeau, C.1    Hulet, C.2    Pages, C.3
  • 5
    • 67650714174 scopus 로고    scopus 로고
    • Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty
    • Oldenburg M., Wegner R., Baur X. Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty. J Arthroplasty 2009, 24:825.e15.
    • (2009) J Arthroplasty , vol.24
    • Oldenburg, M.1    Wegner, R.2    Baur, X.3
  • 6
    • 0038005468 scopus 로고    scopus 로고
    • Massive metallosis after revision of a fractured ceramic head onto a metal head
    • Matziolis G., Perka C., Disch A. Massive metallosis after revision of a fractured ceramic head onto a metal head. Arch Orthop Trauma Surg 2003, 123:48.
    • (2003) Arch Orthop Trauma Surg , vol.123 , pp. 48
    • Matziolis, G.1    Perka, C.2    Disch, A.3
  • 7
    • 0037657959 scopus 로고    scopus 로고
    • Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study
    • Allain J., Roudot-Thoraval F., Delecrin J., et al. Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg Am 2003, 85-A:825.
    • (2003) J Bone Joint Surg Am , pp. 825
    • Allain, J.1    Roudot-Thoraval, F.2    Delecrin, J.3
  • 8
    • 78649835865 scopus 로고    scopus 로고
    • Arthroprosthetic cobaltism: neurological and cardiac manifestations in Two patients with metal-on-metal arthroplasty: a case report
    • Tower S. Arthroprosthetic cobaltism: neurological and cardiac manifestations in Two patients with metal-on-metal arthroplasty: a case report. J Bone Joint Surg Am 2010, 92A:5.
    • (2010) J Bone Joint Surg Am , vol.92 A , pp. 5
    • Tower, S.1
  • 9
    • 0041317170 scopus 로고    scopus 로고
    • Comparison of cross-linked polyethylene materials for orthopaedic applications
    • Collier J., Currier B., Kennedy F., et al. Comparison of cross-linked polyethylene materials for orthopaedic applications. Clin Orthop Relat Res 2003, 414:289.
    • (2003) Clin Orthop Relat Res , vol.414 , pp. 289
    • Collier, J.1    Currier, B.2    Kennedy, F.3
  • 10
    • 0041420955 scopus 로고    scopus 로고
    • Third-body wear of highly cross-linked polyethylene in a hip simulator
    • Bragdon C., Jasty M., Muratoglu O., et al. Third-body wear of highly cross-linked polyethylene in a hip simulator. J Arthroplasty 2003, 18:553.
    • (2003) J Arthroplasty , vol.18 , pp. 553
    • Bragdon, C.1    Jasty, M.2    Muratoglu, O.3
  • 11
    • 78649323060 scopus 로고    scopus 로고
    • Is there a risk in placing a ceramic head on a previously implanted trunion?
    • Hannouche D., Delambre J., Zadegan F., et al. Is there a risk in placing a ceramic head on a previously implanted trunion?. Clin Orthop Relat Res 2010, 1.
    • (2010) Clin Orthop Relat Res , pp. 1
    • Hannouche, D.1    Delambre, J.2    Zadegan, F.3
  • 12
    • 0029558228 scopus 로고
    • Fracture of an alumina ceramic head in total hip arthroplasty
    • Higuchi F., Shiba N., Inoue A., et al. Fracture of an alumina ceramic head in total hip arthroplasty. J Arthroplasty 1995, 10:851.
    • (1995) J Arthroplasty , vol.10 , pp. 851
    • Higuchi, F.1    Shiba, N.2    Inoue, A.3
  • 13
    • 4644234883 scopus 로고    scopus 로고
    • Zirconia femoral head fractures: a clinical and retrieval analysis
    • Masonis J., Bourne R., Ries M., et al. Zirconia femoral head fractures: a clinical and retrieval analysis. J Arthroplasty 2004, 19:898.
    • (2004) J Arthroplasty , vol.19 , pp. 898
    • Masonis, J.1    Bourne, R.2    Ries, M.3
  • 14
    • 38949161946 scopus 로고    scopus 로고
    • Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. Boston, MA
    • Koo K., Ha Y., Woon H., et al. Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. Boston, MA. J Bone Joint Surg Am 2008.
    • (2008) J Bone Joint Surg Am
    • Koo, K.1    Ha, Y.2    Woon, H.3
  • 15
    • 0345491958 scopus 로고    scopus 로고
    • Fractures of ceramic bearings: history and present status
    • Hannouche D., Nich C., Bizot P., et al. Fractures of ceramic bearings: history and present status. Clin Orthop Relat Res 2003, 417:19.
    • (2003) Clin Orthop Relat Res , vol.417 , pp. 19
    • Hannouche, D.1    Nich, C.2    Bizot, P.3
  • 17
    • 33645658517 scopus 로고    scopus 로고
    • Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. Boston, MA
    • Park Y.-S., Hwang S.-K., Choy W.-S., et al. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. Boston, MA. J Bone Joint Surg Am 2006.
    • (2006) J Bone Joint Surg Am
    • Park, Y.-S.1    Hwang, S.-K.2    Choy, W.-S.3
  • 18
    • 34247847840 scopus 로고    scopus 로고
    • Ceramic liner fracture after cementless alumina-on-alumina total Hip arthroplasty
    • Ha Y.-C., Kim S.-Y., Kim H.J., et al. Ceramic liner fracture after cementless alumina-on-alumina total Hip arthroplasty. Clin Orthop Relat Res 2007, 458:106.
    • (2007) Clin Orthop Relat Res , vol.458 , pp. 106
    • Ha, Y.-C.1    Kim, S.-Y.2    Kim, H.J.3
  • 19
    • 68749104638 scopus 로고    scopus 로고
    • Clinical fracture of cross-linked UHMWPE acetabular liners
    • Furmanski J., Anderson M., Bal S., et al. Clinical fracture of cross-linked UHMWPE acetabular liners. Biomaterials 2009, 30:5572.
    • (2009) Biomaterials , vol.30 , pp. 5572
    • Furmanski, J.1    Anderson, M.2    Bal, S.3
  • 20
    • 1842473877 scopus 로고    scopus 로고
    • Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report
    • Halley D., Glassman A., Crowninshield R. Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report. J Bone Joint Surg Am 2004, 86:827.
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 827
    • Halley, D.1    Glassman, A.2    Crowninshield, R.3
  • 21
    • 35349019671 scopus 로고    scopus 로고
    • Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty
    • Tower S., Currier J., Currier B., et al. Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am 2007, 89:2212.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2212
    • Tower, S.1    Currier, J.2    Currier, B.3
  • 22
    • 76249109227 scopus 로고    scopus 로고
    • THA with delta ceramic on ceramic: results of a multicenter investigational device exemption trial
    • Hamilton W., McAuley J., Dennis D., et al. THA with delta ceramic on ceramic: results of a multicenter investigational device exemption trial. Clin Orthop Relat Res 2010, 468:358.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 358
    • Hamilton, W.1    McAuley, J.2    Dennis, D.3
  • 23
    • 61449099441 scopus 로고    scopus 로고
    • Ceramic materials as bearing surfaces for total hip arthroplasty
    • D'Antonio J., Sutton K. Ceramic materials as bearing surfaces for total hip arthroplasty. J Am Acad Orthop Surg 2009, 17:63.
    • (2009) J Am Acad Orthop Surg , vol.17 , pp. 63
    • D'Antonio, J.1    Sutton, K.2
  • 24
    • 76249129686 scopus 로고    scopus 로고
    • Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis
    • Lombardi A., Berend K., Seng B., et al. Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis. Clin Orthop Relat Res 2010, 468:367.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 367
    • Lombardi, A.1    Berend, K.2    Seng, B.3
  • 25
    • 72349090736 scopus 로고    scopus 로고
    • Metal release and corrosion effects of modular neck total hip arthroplasty
    • Kretzer J., Jakubowitz E., Krachler M., et al. Metal release and corrosion effects of modular neck total hip arthroplasty. Int Orthop 2009, 33:1531.
    • (2009) Int Orthop , vol.33 , pp. 1531
    • Kretzer, J.1    Jakubowitz, E.2    Krachler, M.3
  • 26
    • 0031940455 scopus 로고    scopus 로고
    • Ceramics for total hip replacement-what a surgeon should know
    • Willmann G. Ceramics for total hip replacement-what a surgeon should know. Orthopedics 1998, 21:173.
    • (1998) Orthopedics , vol.21 , pp. 173
    • Willmann, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.