메뉴 건너뛰기




Volumn 429, Issue , 2004, Pages 73-79

Concerns about ceramics in THA

Author keywords

[No Author keywords available]

Indexed keywords

ABRASION; CERAMIC PROSTHESIS; CONFERENCE PAPER; FEMUR HEAD; FEMUR NECK; FRACTURE; GAIT; HUMAN; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROSTHESIS MATERIAL; QUALITY CONTROL; STRESS STRAIN RELATIONSHIP; TOTAL HIP PROSTHESIS;

EID: 9644255629     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/01.blo.0000150132.11142.d2     Document Type: Conference Paper
Times cited : (155)

References (30)
  • 1
    • 0031664878 scopus 로고    scopus 로고
    • Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report
    • Allain J, Goutallier D, Voisin MC, Lemouel S: Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report. J Bone Joint Surg 80A:1355-1360, 1998.
    • (1998) J Bone Joint Surg , vol.80 A , pp. 1355-1360
    • Allain, J.1    Goutallier, D.2    Voisin, M.C.3    Lemouel, S.4
  • 2
    • 0037657959 scopus 로고    scopus 로고
    • Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study
    • Allain J, Roudot-Thoraval F, Delecrin J, et al: Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg 85A:825-830, 2003.
    • (2003) J Bone Joint Surg , vol.85 A , pp. 825-830
    • Allain, J.1    Roudot-Thoraval, F.2    Delecrin, J.3
  • 3
    • 0029809381 scopus 로고    scopus 로고
    • Concerns with cementless modular acetabular components
    • Barrack RL: Concerns with cementless modular acetabular components. Orthopedics 19:741-743, 1996.
    • (1996) Orthopedics , vol.19 , pp. 741-743
    • Barrack, R.L.1
  • 4
    • 0035205987 scopus 로고    scopus 로고
    • Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty
    • Barrack RL, Lavernia C, Ries M, Thornberry R, Tozakoglou E: Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty. Orthop Clin North Am 32:569-577, vii, 2001.
    • (2001) Orthop Clin North Am , vol.32 , pp. 569-577
    • Barrack, R.L.1    Lavernia, C.2    Ries, M.3    Thornberry, R.4    Tozakoglou, E.5
  • 5
    • 0036636054 scopus 로고    scopus 로고
    • Impingement and rim wear associated with early osteolysis after a total hip replacement: A case report
    • Barrack RL, Schmalzried TP: Impingement and rim wear associated with early osteolysis after a total hip replacement: a case report. J Bone Joint Surg 84A: 1218-1220, 2002.
    • (2002) J Bone Joint Surg , vol.84 A , pp. 1218-1220
    • Barrack, R.L.1    Schmalzried, T.P.2
  • 7
    • 1642300197 scopus 로고    scopus 로고
    • Experience with current generation ceramic liners
    • Garino JP, Willmann G (eds). Stuttgart, Germany, Thieme International
    • Beaver RJ, McCormick C, Kop A: Experience with Current Generation Ceramic Liners. In Garino JP, Willmann G (eds). Bioceramics in Joint Arthroplasty. Stuttgart, Germany, Thieme International 65-71, 2003.
    • (2003) Bioceramics in Joint Arthroplasty , pp. 65-71
    • Beaver, R.J.1    McCormick, C.2    Kop, A.3
  • 8
    • 0033855584 scopus 로고    scopus 로고
    • Wear debris from two different alumina-on-alumina total hip arthroplasties
    • Bohler M, Mochida Y, Bauer TW, Plenk Jr. H, Salzer M: Wear debris from two different alumina-on-alumina total hip arthroplasties. J Bone Joint Surg 82B:901-909, 2000.
    • (2000) J Bone Joint Surg , vol.82 B , pp. 901-909
    • Bohler, M.1    Mochida, Y.2    Bauer, T.W.3    Plenk Jr., H.4    Salzer, M.5
  • 11
    • 0033779502 scopus 로고    scopus 로고
    • Modern ceramic-on-ceramic total hip systems in the United States
    • Garino JP: Modern ceramic-on-ceramic total hip systems in the United States. Clin Orthop 379:41-47, 2000.
    • (2000) Clin Orthop , vol.379 , pp. 41-47
    • Garino, J.P.1
  • 12
    • 0034293443 scopus 로고    scopus 로고
    • Osteolysis and ceramic bearing surfaces
    • Garino JP, Nizard R, Bizot P, et al: Osteolysis and ceramic bearing surfaces. J Bone Joint Surg 82A: 1518-1521, 2000.
    • (2000) J Bone Joint Surg , vol.82 A , pp. 1518-1521
    • Garino, J.P.1    Nizard, R.2    Bizot, P.3
  • 13
    • 0346035850 scopus 로고    scopus 로고
    • Effects of clinically relevant alumina ceramic wear particles on TNF-alpha. Production by human peripheral blood mononuclear phagocytes
    • Hatton A, Nevelos JE, Matthews JB, Fisher J, Ingham E: Effects of clinically relevant alumina ceramic wear particles on TNF-alpha. Production by human peripheral blood mononuclear phagocytes. Biomaterials 24:1193-1204, 2003.
    • (2003) Biomaterials , vol.24 , pp. 1193-1204
    • Hatton, A.1    Nevelos, J.E.2    Matthews, J.B.3    Fisher, J.4    Ingham, E.5
  • 14
    • 0001549373 scopus 로고    scopus 로고
    • Ceramics in total hip arthroplasty: History, mechanical properties, clinical results, and current manufacturing state of the art
    • Heros RJ, Willmann G: Ceramics in total hip arthroplasty: History, mechanical properties, clinical results, and current manufacturing state of the art. Semin Arthroplasty 9:114-122, 1998.
    • (1998) Semin Arthroplasty , vol.9 , pp. 114-122
    • Heros, R.J.1    Willmann, G.2
  • 15
    • 0025882353 scopus 로고
    • Primary ceramic hip replacement: A prospective study of 119 hips
    • Hoffinger Sa: Keggi KJ, Zatorski LE: Primary ceramic hip replacement: a prospective study of 119 hips. Orthopedics 14:523-531, 1991.
    • (1991) Orthopedics , vol.14 , pp. 523-531
    • Hoffinger, Sa.1    Keggi, K.J.2    Zatorski, L.E.3
  • 16
    • 0028245867 scopus 로고
    • Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
    • Huk OK, Bansal M, Bettes F, et al: Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Joint Surg 76B:568-574, 1994.
    • (1994) J Bone Joint Surg , vol.76 B , pp. 568-574
    • Huk, O.K.1    Bansal, M.2    Bettes, F.3
  • 17
    • 0025393979 scopus 로고
    • Analysis of removed autophor ceramic-on-ceramic components
    • Kummer FJ, Stuchin SA, Frankel VH: Analysis of removed autophor ceramic-on-ceramic components. J Arthroplasty 5:28-33, 1990.
    • (1990) J Arthroplasty , vol.5 , pp. 28-33
    • Kummer, F.J.1    Stuchin, S.A.2    Frankel, V.H.3
  • 18
    • 0031016523 scopus 로고    scopus 로고
    • Ceramic-ceramic and metal-polyethylene total hip replacements. Comparison of pseudomembranes after loosening
    • Lerouge S, Huk O, Yahia LH, Witvoet J, Sedel L: Ceramic-ceramic and metal-polyethylene total hip replacements. Comparison of pseudomembranes after loosening. J Bone Joint Surg 79B:135-139, 1997.
    • (1997) J Bone Joint Surg , vol.79 B , pp. 135-139
    • Lerouge, S.1    Huk, O.2    Yahia, L.H.3    Witvoet, J.4    Sedel, L.5
  • 19
    • 0025350439 scopus 로고
    • Unsatisfactory results with a ceramic total hip prosthesis
    • Mahoney OM, Dimon III JH: Unsatisfactory results with a ceramic total hip prosthesis. J Bone Joint Surg 72A:663-671, 1990.
    • (1990) J Bone Joint Surg , vol.72 A , pp. 663-671
    • Mahoney, O.M.1    Dimon III, J.H.2
  • 20
    • 0034909915 scopus 로고    scopus 로고
    • Debris from failed ceramic-on-ceramic and ceramic-on-polyethylene hip prostheses
    • Mochida Y, Boehler M, Salzer M, Bauer TW: Debris from failed ceramic-on-ceramic and ceramic-on-polyethylene hip prostheses. Clin Orthop 389:113-125, 2001.
    • (2001) Clin Orthop , vol.389 , pp. 113-125
    • Mochida, Y.1    Boehler, M.2    Salzer, M.3    Bauer, T.W.4
  • 21
    • 0034981637 scopus 로고    scopus 로고
    • Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening
    • Nevelos JE, Prudhommeaux F, Hamadouche M, et al: Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg 83B:598-603, 2001.
    • (2001) J Bone Joint Surg , vol.83 B , pp. 598-603
    • Nevelos, J.E.1    Prudhommeaux, F.2    Hamadouche, M.3
  • 22
    • 0036726566 scopus 로고    scopus 로고
    • Ceramic-ceramic bearings in THA: The new gold standard- in opposition
    • Rorabeck CH: Ceramic-ceramic bearings in THA: The new gold standard- in opposition. Orthopedics 25:935-936, 2002.
    • (2002) Orthopedics , vol.25 , pp. 935-936
    • Rorabeck, C.H.1
  • 23
    • 0033779539 scopus 로고    scopus 로고
    • Evolution of alumina-alumina implants
    • Sedel L: Evolution of alumina-alumina implants. Clin Orthop 379:48-54, 2000.
    • (2000) Clin Orthop , vol.379 , pp. 48-54
    • Sedel, L.1
  • 24
    • 0348136065 scopus 로고    scopus 로고
    • Clinical and simulator wear study of alumina ceramic THR to 17 years and beyond
    • Shishido T, Clarke IC, Williams P, et al: Clinical and simulator wear study of alumina ceramic THR to 17 years and beyond. J Biomed Mater Res 67B:638-647, 2003.
    • (2003) J Biomed Mater Res , vol.67 B , pp. 638-647
    • Shishido, T.1    Clarke, I.C.2    Williams, P.3
  • 25
    • 0032778766 scopus 로고    scopus 로고
    • Ceramic bearing surfaces
    • Skinner HB: Ceramic bearing surfaces. Clin Orthop 369:83-91, 1999.
    • (1999) Clin Orthop , vol.369 , pp. 83-91
    • Skinner, H.B.1
  • 26
    • 0345168992 scopus 로고    scopus 로고
    • Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation
    • Stewart TD, Tipper JL, Insley G, et al: Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. J Biomed Mater Res 66B:567-573, 2003.
    • (2003) J Biomed Mater Res , vol.66 B , pp. 567-573
    • Stewart, T.D.1    Tipper, J.L.2    Insley, G.3
  • 27
    • 0026761335 scopus 로고
    • On the material and the tribology of alumina-Alumina couplings for hip joint prostheses
    • Walter A: On the material and the tribology of alumina-Alumina couplings for hip joint prostheses. Clin Orthop 282:31-46, 1992.
    • (1992) Clin Orthop , vol.282 , pp. 31-46
    • Walter, A.1
  • 28
    • 0030911376 scopus 로고    scopus 로고
    • Massive osteolysis after ceramic on ceramic total hip arthroplasty. A case report
    • Wirganowicz PZ, Thomas BJ: Massive osteolysis after ceramic on ceramic total hip arthroplasty. A case report. Clin Orthop 338:100-104, 1997.
    • (1997) Clin Orthop , vol.338 , pp. 100-104
    • Wirganowicz, P.Z.1    Thomas, B.J.2
  • 29
    • 0034114175 scopus 로고    scopus 로고
    • The spatial location of impingement in total hip arthroplasty
    • Yamaguchi M, Akisue T, Bauer TW, Hasimoto Y: The spatial location of impingement in total hip arthroplasty. J Arthroplasty 15:305-313, 2000.
    • (2000) J Arthroplasty , vol.15 , pp. 305-313
    • Yamaguchi, M.1    Akisue, T.2    Bauer, T.W.3    Hasimoto, Y.4
  • 30
    • 0031758471 scopus 로고    scopus 로고
    • Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces
    • Yoon TR, Rowe SM, Jung ST, Seon KJ, Maloney WJ: Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. J Bone Joint Surg 80A:1459-1468, 1998.
    • (1998) J Bone Joint Surg , vol.80 A , pp. 1459-1468
    • Yoon, T.R.1    Rowe, S.M.2    Jung, S.T.3    Seon, K.J.4    Maloney, W.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.