Volumn 28, Issue 1, 2013, Pages 197.e1-197.e4

Leg Edema Due to a Mass in the Pelvis After a Large-Diameter Metal-On-Metal Total Hip Arthroplasty

Author keywords

Hypersensitivity; Large diameter metal on metal total hip arthroplasty; Leg edema; Pelvic mass; Pseudotumor

Indexed keywords

METAL;

EID: 84870755316     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2012.04.016     Document Type: Article
Times cited : (17)

References (13)
  • 1
    • 0346963001 scopus 로고    scopus 로고
    • Total hip wear debris presenting as lower extremity swelling. A report of two cases
    • Butler R.A., Barrack R.L. Total hip wear debris presenting as lower extremity swelling. A report of two cases. J Bone Joint Surg Am 2004, 86-A:142.
    • (2004) J Bone Joint Surg Am , pp. 142
    • Butler, R.A.1    Barrack, R.L.2
  • 2
    • 33947578276 scopus 로고    scopus 로고
    • Extravascular compression of the femoral vein due to wear debris-induced iliopsoas bursitis: a rare cause of leg swelling after total hip arthroplasty
    • Beksac B., et al. Extravascular compression of the femoral vein due to wear debris-induced iliopsoas bursitis: a rare cause of leg swelling after total hip arthroplasty. J Arthroplasty 2007, 22:453.
    • (2007) J Arthroplasty , vol.22 , pp. 453
    • Beksac, B.1
  • 3
    • 79955083655 scopus 로고    scopus 로고
    • High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis
    • Bolland B.J., et al. High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis. J Bone Joint Surg Br 2011, 93:608.
    • (2011) J Bone Joint Surg Br , vol.93 , pp. 608
    • Bolland, B.J.1
  • 4
    • 0026534146 scopus 로고
    • Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants
    • Brien W.W., et al. Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants. Clin Orthop Relat Res 1992, 66.
    • (1992) Clin Orthop Relat Res , pp. 66
    • Brien, W.W.1
  • 5
    • 55849141251 scopus 로고    scopus 로고
    • Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing
    • De Smet K., et al. Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. J Bone Joint Surg Am 2008, 90(Suppl 4):202.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.SUPPL. 4 , pp. 202
    • De Smet, K.1
  • 6
    • 0025679122 scopus 로고
    • Histologic, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty
    • Dorr L.D., et al. Histologic, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty. Clin Orthop Relat Res 1990, 82.
    • (1990) Clin Orthop Relat Res , pp. 82
    • Dorr, L.D.1
  • 7
    • 77955563721 scopus 로고    scopus 로고
    • Histological features of pseudotumor-like tissues from metal-on-metal hips
    • Campbell P., et al. Histological features of pseudotumor-like tissues from metal-on-metal hips. Clin Orthop Relat Res 2010, 468:2321.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 2321
    • Campbell, P.1
  • 8
    • 76249101202 scopus 로고    scopus 로고
    • Metal-on-metal hip arthroplasty: does early clinical outcome justify the chance of an adverse local tissue reaction?
    • Engh C.A., Ho H., Engh C.A. Metal-on-metal hip arthroplasty: does early clinical outcome justify the chance of an adverse local tissue reaction?. Clin Orthop Relat Res 2010, 468:406.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 406
    • Engh, C.A.1    Ho, H.2    Engh, C.A.3
  • 9
    • 11844293972 scopus 로고    scopus 로고
    • Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study
    • Willert H.G., et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 2005, 87:28.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 28
    • Willert, H.G.1
  • 10
    • 80053923596 scopus 로고    scopus 로고
    • Noninflammatory pseudotumor simulating venous thrombosis after metal-on-metal hip resurfacing
    • Maurer-Ertl W., et al. Noninflammatory pseudotumor simulating venous thrombosis after metal-on-metal hip resurfacing. Orthopedics 2011, 34:e678.
    • (2011) Orthopedics , vol.34
    • Maurer-Ertl, W.1
  • 11
    • 77949522055 scopus 로고    scopus 로고
    • Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty
    • Kwon Y.M., et al. Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty. J Orthop Res 2010, 28:444.
    • (2010) J Orthop Res , vol.28 , pp. 444
    • Kwon, Y.M.1
  • 12
    • 84868303108 scopus 로고    scopus 로고
    • Gender is a significant factor for failure of metal-on-metal total hip arthroplasty
    • Latteier M.J., et al. Gender is a significant factor for failure of metal-on-metal total hip arthroplasty. J Arthroplasty 2011, 26(6 Suppl):19.
    • (2011) J Arthroplasty , vol.26 , Issue.6 SUPPL. , pp. 19
    • Latteier, M.J.1
  • 13
    • 72249088640 scopus 로고    scopus 로고
    • Risk factors for inflammatory pseudotumour formation following hip resurfacing
    • Glyn-Jones S., et al. Risk factors for inflammatory pseudotumour formation following hip resurfacing. J Bone Joint Surg Br 2009, 91:1566.
    • (2009) J Bone Joint Surg Br , vol.91 , pp. 1566
    • Glyn-Jones, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.