메뉴 건너뛰기




Volumn 56, Issue , 2013, Pages 48-55

A novel human body exergy consumption formula to determine indoor thermal conditions for optimal human performance in office buildings

Author keywords

Human body exergy consumption; Human performance; Indoor thermal conditions; Office work; Thermal comfort; Thermal sensation

Indexed keywords

EXERGY CONSUMPTION; HUMAN PERFORMANCE; OFFICE WORK; THERMAL CONDITION; THERMAL SENSATIONS;

EID: 84870662404     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2012.10.010     Document Type: Article
Times cited : (32)

References (30)
  • 1
    • 0041598920 scopus 로고
    • Cost avoidance and productivity in owning and operating buildings
    • J.E. Wood Cost avoidance and productivity in owning and operating buildings Occupational Medicine: The State of art Reviews 44 1989 753 770
    • (1989) Occupational Medicine: The State of Art Reviews , vol.44 , pp. 753-770
    • Wood, J.E.1
  • 2
    • 0000467925 scopus 로고    scopus 로고
    • Estimates of improved productivity and health from better indoor environments
    • J.W. Fisk, and A.H. Rosenfeld Estimates of improved productivity and health from better indoor environments Indoor Air 7 1997 158 172
    • (1997) Indoor Air , vol.7 , pp. 158-172
    • Fisk, J.W.1    Rosenfeld, A.H.2
  • 6
    • 79953025548 scopus 로고
    • A software tool for relating the comfort and productivity of occupants in commercial buildings
    • D. Loveday, V.I. Hanby, and W.B. Woodward A software tool for relating the comfort and productivity of occupants in commercial buildings Proceedings of CIBSE National Conference 1995 69 75
    • (1995) Proceedings of CIBSE National Conference , pp. 69-75
    • Loveday, D.1    Hanby, V.I.2    Woodward, W.B.3
  • 7
    • 4344572390 scopus 로고    scopus 로고
    • Assessment of productivity loss in air-conditioned buildings using PMV index
    • R. Kosonen, and F. Tan Assessment of productivity loss in air-conditioned buildings using PMV index Energy and Buildings 36 2004 987 993
    • (2004) Energy and Buildings , vol.36 , pp. 987-993
    • Kosonen, R.1    Tan, F.2
  • 8
    • 56349166073 scopus 로고    scopus 로고
    • A Bayesian network approach to the evaluation of building design and its consequences for employee performance and operational costs
    • K.L. Jensen, J. Toftum, and P. Friis-Hansen A Bayesian network approach to the evaluation of building design and its consequences for employee performance and operational costs Building and Environment 44 2009 456 462
    • (2009) Building and Environment , vol.44 , pp. 456-462
    • Jensen, K.L.1    Toftum, J.2    Friis-Hansen, P.3
  • 9
    • 79953026302 scopus 로고    scopus 로고
    • Quantitative measurement of productivity loss due to thermal discomfort
    • L. Lan, P. Wargocki, and Z. Lian Quantitative measurement of productivity loss due to thermal discomfort Energy and Buildings 43 2011 1057 1062
    • (2011) Energy and Buildings , vol.43 , pp. 1057-1062
    • Lan, L.1    Wargocki, P.2    Lian, Z.3
  • 10
    • 10444279226 scopus 로고    scopus 로고
    • Thermodynamic analysis of human heat and mass transfer and their impact on thermal comfort
    • M. Prek Thermodynamic analysis of human heat and mass transfer and their impact on thermal comfort International Journal of Heat and Mass Transfer 48 2006 731 739
    • (2006) International Journal of Heat and Mass Transfer , vol.48 , pp. 731-739
    • Prek, M.1
  • 14
    • 77957311219 scopus 로고    scopus 로고
    • Principles of exergy analysis of human energy exchange with the indoor environment
    • M. Prek, and V. Butala Principles of exergy analysis of human energy exchange with the indoor environment International Journal of Heat and Mass Transfer 53 2010 5806 5814
    • (2010) International Journal of Heat and Mass Transfer , vol.53 , pp. 5806-5814
    • Prek, M.1    Butala, V.2
  • 15
    • 0024430628 scopus 로고
    • Entropy flow and entropy generated in human body in basal conditions
    • I. Aoki Entropy flow and entropy generated in human body in basal conditions Journal of Theoretical Biology 141 1 1989 11 21
    • (1989) Journal of Theoretical Biology , vol.141 , Issue.1 , pp. 11-21
    • Aoki, I.1
  • 18
    • 34250642754 scopus 로고    scopus 로고
    • A novel method for estimating the entropy generation rate in a human body
    • M.A. Rahman A novel method for estimating the entropy generation rate in a human body Thermal Science 11 1 2007 75 92
    • (2007) Thermal Science , vol.11 , Issue.1 , pp. 75-92
    • Rahman, M.A.1
  • 19
    • 77957324358 scopus 로고    scopus 로고
    • Entropy generation and human aging: Lifespan entropy and effect of diet composition and caloric restriction diets
    • C.A. Silva, and K. Annamalai Entropy generation and human aging: lifespan entropy and effect of diet composition and caloric restriction diets Journal of Thermodynamics 2009 2009 1 10
    • (2009) Journal of Thermodynamics , vol.2009 , pp. 1-10
    • Silva, C.A.1    Annamalai, K.2
  • 20
    • 0015248608 scopus 로고
    • An effective temperature scale based on a simple model of human physiological regulatory response
    • A.P. Gagge, J. Stolwijk, and Y. Nishi An effective temperature scale based on a simple model of human physiological regulatory response ASHRAE Transactions 77 1 1971 247 262
    • (1971) ASHRAE Transactions , vol.77 , Issue.1 , pp. 247-262
    • Gagge, A.P.1    Stolwijk, J.2    Nishi, Y.3
  • 21
    • 0003640899 scopus 로고    scopus 로고
    • Thermal comfort Chapter 9
    • Thermal comfort. ASHRAE Handbook, Chapter 9, 2009.
    • (2009) ASHRAE Handbook
  • 28
    • 78049454431 scopus 로고    scopus 로고
    • A relation between calculated human body exergy consumption rate and subjectively assessed thermal sensation
    • Simone A relation between calculated human body exergy consumption rate and subjectively assessed thermal sensation Energy and Buildings 43 2011 1 9
    • (2011) Energy and Buildings , vol.43 , pp. 1-9
    • Simone1
  • 29
    • 0000501513 scopus 로고    scopus 로고
    • Individual microclimate control: Required range, probable benefits and current feasibility
    • Institute of Public Health Tokyo
    • D.P. Wyon Individual microclimate control: required range, probable benefits and current feasibility Proceedings of Indoor Air 96 1996 Institute of Public Health Tokyo
    • (1996) Proceedings of Indoor Air 96
    • Wyon, D.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.