메뉴 건너뛰기




Volumn 44, Issue 3, 2009, Pages 456-462

A Bayesian Network approach to the evaluation of building design and its consequences for employee performance and operational costs

Author keywords

Bayesian Network; Indoor Climate; Performance; Temperature; Total building economics

Indexed keywords

BUILDINGS; DESIGN; DISTRIBUTED PARAMETER NETWORKS; ECONOMICS; INFERENCE ENGINES; INTELLIGENT NETWORKS; OFFICE BUILDINGS; SPEECH ANALYSIS;

EID: 56349166073     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2008.04.008     Document Type: Article
Times cited : (117)

References (27)
  • 1
    • 56349134255 scopus 로고    scopus 로고
    • Wargocki P, Seppänen O, Andersson J, Boerstra A, Clements-Croome D, Fitzner K, et al. In: Wargocki P, Seppänen O (editors). Indoor climate and productivity in offices-how to integrate productivity in life-cycle cost analysis of building services, REHVA Guidebook no 6. Finland: Rehva, 2006.
    • Wargocki P, Seppänen O, Andersson J, Boerstra A, Clements-Croome D, Fitzner K, et al. In: Wargocki P, Seppänen O (editors). Indoor climate and productivity in offices-how to integrate productivity in life-cycle cost analysis of building services, REHVA Guidebook no 6. Finland: Rehva, 2006.
  • 2
    • 56349125942 scopus 로고    scopus 로고
    • Fisk WJ, Seppänen O. Providing better indoor environmental quality brings economic benefits, Key-note lectures. In: Proceedings of the Clima 2007 Wellbeing Indoors conference, Helsinki, Finland, 2007.
    • Fisk WJ, Seppänen O. Providing better indoor environmental quality brings economic benefits, Key-note lectures. In: Proceedings of the Clima 2007 Wellbeing Indoors conference, Helsinki, Finland, 2007.
  • 3
    • 33645236303 scopus 로고    scopus 로고
    • Ventilation and performance in office work
    • Seppänen O., Fisk W.J., and Lei Q.H. Ventilation and performance in office work. Indoor Air 16 (2006) 28-36
    • (2006) Indoor Air , vol.16 , pp. 28-36
    • Seppänen, O.1    Fisk, W.J.2    Lei, Q.H.3
  • 4
    • 0002838007 scopus 로고    scopus 로고
    • Estimates of potential nationwide productivity and health benefits from better indoor environments: an update
    • Spengler J., Sammet J., and MacCarthy J.F. (Eds), McGraw Hill, New York
    • Fisk W.J. Estimates of potential nationwide productivity and health benefits from better indoor environments: an update. In: Spengler J., Sammet J., and MacCarthy J.F. (Eds). IAQ handbook (2001), McGraw Hill, New York
    • (2001) IAQ handbook
    • Fisk, W.J.1
  • 7
    • 8444239052 scopus 로고    scopus 로고
    • The Bayesian brain: the role of uncertainty in neural coding and computation
    • Knill D.C., and Pouget A. The Bayesian brain: the role of uncertainty in neural coding and computation. TRENDS in Neurosciences 27 12 (2004) 712-719
    • (2004) TRENDS in Neurosciences , vol.27 , Issue.12 , pp. 712-719
    • Knill, D.C.1    Pouget, A.2
  • 8
    • 33846481123 scopus 로고    scopus 로고
    • Bayesian Network Model for the design of roofpond equipped buildings
    • Naticchia B., Fernadez-Gonzalez A., and Carbonari A. Bayesian Network Model for the design of roofpond equipped buildings. Energy and Buildings 39 (2007) 258-272
    • (2007) Energy and Buildings , vol.39 , pp. 258-272
    • Naticchia, B.1    Fernadez-Gonzalez, A.2    Carbonari, A.3
  • 9
    • 56349117044 scopus 로고    scopus 로고
    • Hugin Expert A/S, 〈www.hugin.com〉.
    • Hugin Expert A/S, 〈www.hugin.com〉.
  • 10
    • 0031632764 scopus 로고    scopus 로고
    • A global database of thermal comfort field experiments
    • de Dear R.J. A global database of thermal comfort field experiments. ASHRAE Transactions 104 1b (1998) 1141-1152
    • (1998) ASHRAE Transactions , vol.104 , Issue.1 b , pp. 1141-1152
    • de Dear, R.J.1
  • 11
    • 56349145011 scopus 로고    scopus 로고
    • ANSI/ASHRAE standard 55-1992: Thermal environment conditions for human occupancy, Atlanta: American Society of Heating, Refrigerating and Air Conditioning Engineers Inc.
    • ANSI/ASHRAE standard 55-1992: Thermal environment conditions for human occupancy, Atlanta: American Society of Heating, Refrigerating and Air Conditioning Engineers Inc.
  • 12
    • 56349153424 scopus 로고    scopus 로고
    • International Standard 7730: Moderate thermal environments-determination of the PMV and PPD indices and specifications of the conditions of thermal comfort, Geneva: International Standards Organization.
    • International Standard 7730: Moderate thermal environments-determination of the PMV and PPD indices and specifications of the conditions of thermal comfort, Geneva: International Standards Organization.
  • 14
    • 79951959421 scopus 로고    scopus 로고
    • Seppänen O, Fisk WJ, Lei QH. Room temperature and productivity in office work. In: Proceedings of Healthy Buildings conference, vol. 1; 2006. p. 243-7.
    • Seppänen O, Fisk WJ, Lei QH. Room temperature and productivity in office work. In: Proceedings of Healthy Buildings conference, vol. 1; 2006. p. 243-7.
  • 16
    • 56349124506 scopus 로고    scopus 로고
    • Toftum J, Wyon DP, Svanekjær H, Latner A. Remote performance measurement (RPM)-a new, internet-based method for the measurement of occupant performance in office buildings. In: Proceedings of Indoor Air 2005, Beijing, China, 2005.
    • Toftum J, Wyon DP, Svanekjær H, Latner A. Remote performance measurement (RPM)-a new, internet-based method for the measurement of occupant performance in office buildings. In: Proceedings of Indoor Air 2005, Beijing, China, 2005.
  • 17
    • 56349144530 scopus 로고    scopus 로고
    • Balazova I, Clausen G, Wyon DP. The influence of exposure to multiple indoor environmental parameters on human perception, performance and motivation. In: Proceedings of the Clima 2007 Wellbeing Indoors conference, Helsinki, Finland, 2007.
    • Balazova I, Clausen G, Wyon DP. The influence of exposure to multiple indoor environmental parameters on human perception, performance and motivation. In: Proceedings of the Clima 2007 Wellbeing Indoors conference, Helsinki, Finland, 2007.
  • 18
    • 56349141407 scopus 로고    scopus 로고
    • Kolarik J, Toftum J, Olesen BW, Shitzer A. Occupant responses and office work performance in environments with moderately drifting operative temperatures-RP1269. Submitted to HVAC&R Research, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, USA, 2008.
    • Kolarik J, Toftum J, Olesen BW, Shitzer A. Occupant responses and office work performance in environments with moderately drifting operative temperatures-RP1269. Submitted to HVAC&R Research, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, USA, 2008.
  • 19
    • 56349143588 scopus 로고    scopus 로고
    • The R Development Core Team, Network Theory Limited, Bristol
    • The R Development Core Team. R reference manual base package 2 (2004), Network Theory Limited, Bristol
    • (2004) R reference manual base package , vol.2
  • 20
    • 56349106781 scopus 로고    scopus 로고
    • Jensen KL, Toftum J. Distribution of thermal sensation votes in offices used to model annual performance decrements. In: Proceedings of the Clima 2007 Wellbeing Indoors conference, Helsinki, Finland, 2007.
    • Jensen KL, Toftum J. Distribution of thermal sensation votes in offices used to model annual performance decrements. In: Proceedings of the Clima 2007 Wellbeing Indoors conference, Helsinki, Finland, 2007.
  • 21
    • 56349095712 scopus 로고    scopus 로고
    • Willem HC. Thermal and indoor air quality effects on physiological responses, perception and performance of tropically acclimatized people. PhD thesis. Department of Building, National University of Singapore, 2006.
    • Willem HC. Thermal and indoor air quality effects on physiological responses, perception and performance of tropically acclimatized people. PhD thesis. Department of Building, National University of Singapore, 2006.
  • 22
    • 0016059645 scopus 로고
    • The effects of moderate heat stress on typewriting performance
    • Wyon D.P. The effects of moderate heat stress on typewriting performance. Ergonomics 17 (1974) 309-318
    • (1974) Ergonomics , vol.17 , pp. 309-318
    • Wyon, D.P.1
  • 23
    • 56349136660 scopus 로고    scopus 로고
    • Hongisto V. Office noise and work performance. In: Proceedings of the Clima 2007 Wellbeing Indoors conference, Helsinki, Finland, 2007.
    • Hongisto V. Office noise and work performance. In: Proceedings of the Clima 2007 Wellbeing Indoors conference, Helsinki, Finland, 2007.
  • 24
    • 4544306302 scopus 로고    scopus 로고
    • The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply rates
    • Wargocki P., Wyon D.P., and Fanger P.O. The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply rates. Indoor Air 14 8 (2004) 7-16
    • (2004) Indoor Air , vol.14 , Issue.8 , pp. 7-16
    • Wargocki, P.1    Wyon, D.P.2    Fanger, P.O.3
  • 25
    • 56349128548 scopus 로고    scopus 로고
    • CR-1752: Ventilation for Buildings, Design for Indoor Environments, Brussels, CEN.
    • CR-1752: Ventilation for Buildings, Design for Indoor Environments, Brussels, CEN.
  • 26
    • 0016532133 scopus 로고
    • The mental performance of subjects clothed for comfort at two different air temperatures
    • Wyon D.P., Fanger P.O., Olesen B.W., and Pedersen C.J.K. The mental performance of subjects clothed for comfort at two different air temperatures. Ergonomics 18 (1975) 359-374
    • (1975) Ergonomics , vol.18 , pp. 359-374
    • Wyon, D.P.1    Fanger, P.O.2    Olesen, B.W.3    Pedersen, C.J.K.4
  • 27
    • 4544338337 scopus 로고    scopus 로고
    • The effects of moderate heat stress and open-plan office noise distraction on SBS symptoms and on the performance of office work
    • Witterseh T., Wyon D.P., and Clausen G. The effects of moderate heat stress and open-plan office noise distraction on SBS symptoms and on the performance of office work. Indoor Air 14 8 (2004) 30-40
    • (2004) Indoor Air , vol.14 , Issue.8 , pp. 30-40
    • Witterseh, T.1    Wyon, D.P.2    Clausen, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.