메뉴 건너뛰기




Volumn 12, Issue 12, 2012, Pages 3373-3383

Correlation between electrode-tissue impedance and motion artifact in biopotential recordings

Author keywords

Correlation; electrocardiogram; electrode tissue impedance; motion artifact

Indexed keywords

AMBULATORY MONITORING; ANALOG FRONT-END; BIOPOTENTIALS; CLINICAL DIAGNOSIS; ECG RECORDING; ECG SIGNAL ACQUISITIONS; ECG SIGNALS; ELECTRODE DESIGN; MOTION ARTIFACT; ON THE GO; PERSONAL HEALTH CARE; SKIN-ELECTRODE IMPEDANCE; TECHNICAL CHALLENGES; ULTRA-LOW POWER; VALIDATION STUDY; WIRELESS SYSTEMS;

EID: 84870556145     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2012.2221163     Document Type: Article
Times cited : (57)

References (34)
  • 1
    • 84870511665 scopus 로고    scopus 로고
    • Bio-medical application of WBAN: Trends and examples
    • H.-J. Yoo and C. Hoof, Eds. New York: Springer-Verlag
    • J. Penders, C. Hoof, and B. Gyselinckx, "Bio-medical application of WBAN: Trends and examples," in Bio-Medical CMOS ICs, H.-J. Yoo and C. Hoof, Eds. New York: Springer-Verlag, 2011, pp. 279-302.
    • (2011) Bio-Medical CMOS ICs , pp. 279-302
    • Penders, J.1    Hoof, C.2    Gyselinckx, B.3
  • 4
    • 70350752708 scopus 로고    scopus 로고
    • Wearable wireless ECG monitoring hardware prototype for use in patients own home
    • J. Justesen and S. Madsen, "Wearable wireless ECG monitoring hardware prototype for use in patients own home," in Proc. 3rd Int. Conf. Pervasive Health, 2009, pp. 1-3.
    • (2009) Proc. 3rd Int. Conf. Pervasive Health , pp. 1-3
    • Justesen, J.1    Madsen, S.2
  • 6
    • 84870534717 scopus 로고    scopus 로고
    • Bioharness BT Annapolis MD
    • Zephyr Technologies. (2010). Bioharness BT, Annapolis, MD [Online]. Available: http://www.zephyr-technology.com/
    • (2010) Zephyr Technologies
  • 7
    • 84870569719 scopus 로고    scopus 로고
    • Vitalsense Amsterdam, The Netherlands
    • Philips Electronics. (2012). Vitalsense, Amsterdam, The Netherlands [Online]. Available: http://www.vitalsense.respironics.com
    • (2012) Philips Electronics
  • 8
    • 84870573811 scopus 로고    scopus 로고
    • Nuvant (MCT), Corventis, San Jose, CA, Dec. 2009
    • Nuvant (MCT), Corventis, San Jose, CA, Dec. 2009.
  • 9
    • 84870503931 scopus 로고    scopus 로고
    • VPatch Mount Waverley Australia
    • V Patch Medical Systems, VPatch, Mount Waverley, Australia, 2011.
    • (2011) V Patch Medical Systems
  • 11
    • 84862938891 scopus 로고    scopus 로고
    • An ECG patch combining a customized ultralowpower ECG SoC with bluetooth low energy for long term ambulatory monitoring
    • M. Altini, S. Polito, J. Penders, N. Kim, H. Helleputte, S. Kim, and R. Yazicioglu, "An ECG patch combining a customized ultralowpower ECG SoC with bluetooth low energy for long term ambulatory monitoring," in Proc. Wireless Health Conf., 2011, pp. 1-15.
    • (2011) Proc. Wireless Health Conf , pp. 1-15
    • Altini, M.1    Polito, S.2    Penders, J.3    Kim, N.4    Helleputte, H.5    Kim, S.6    Yazicioglu, R.7
  • 14
    • 79953828002 scopus 로고    scopus 로고
    • Separating cardiac and muscular ECG components using adaptive modelling in time-frequency domain
    • P. Augustyniak, "Separating cardiac and muscular ECG components using adaptive modelling in time-frequency domain," in Proc. WACBE World Congr. Bioeng., 2007, pp. 1-4.
    • (2007) Proc. WACBE World Congr. Bioeng , pp. 1-4
    • Augustyniak, P.1
  • 15
    • 84870509954 scopus 로고    scopus 로고
    • PCA and ICA applied to noise reduction in multi-lead ECG
    • I. Romero, "PCA and ICA applied to noise reduction in multi-lead ECG," in Proc. Comput. Cardiol., 2011, pp. 1-4.
    • (2011) Proc. Comput. Cardiol , pp. 1-4
    • Romero, I.1
  • 17
    • 0034041088 scopus 로고    scopus 로고
    • Effect of adaptive motion-artifact reduction on QRS detection
    • P. Hamilton, M. Curley, and R. Aimi, "Effect of adaptive motion-artifact reduction on QRS detection," Biomed. Instrum. Technol., vol. 34, no. 3, pp. 197-202, 2000. (Pubitemid 30396053)
    • (2000) Biomedical Instrumentation and Technology , vol.34 , Issue.3 , pp. 197-202
    • Hamilton, P.S.1    Curley, M.2    Aimi, R.3
  • 18
    • 0036911308 scopus 로고    scopus 로고
    • Adaptive reduction of motion artifact in the electrocardiogram
    • D. Tong, K. Bartels, and K. Honeyager, "Adaptive reduction of motion artifact in the electrocardiogram," in Proc. 2nd Joint EMBS/BMES Conf., vol. 2. 2002, pp. 1403-1404.
    • (2002) Proc. 2nd Joint EMBS/BMES Conf , vol.2 , pp. 1403-1404
    • Tong, D.1    Bartels, K.2    Honeyager, K.3
  • 19
    • 0036911208 scopus 로고    scopus 로고
    • Adaptive noise cancelling of motion artifact in stress ECG signals using accelerometer
    • M. Raya and L. Sison, "Adaptive noise cancelling of motion artifact in stress ECG signals using accelerometer," in Proc. 2nd Joint EMBS/BMES Conf., vol. 2. 2002, pp. 1756-1757.
    • (2002) Proc. 2nd Joint EMBS/BMES Conf , vol.2 , pp. 1756-1757
    • Raya, M.1    Sison, L.2
  • 20
    • 84991995365 scopus 로고
    • Detection electrode motion noise in ECG signals by monitoring electrode impedance
    • P. H. Devlin, R. G. Mark, and J. W. Ketchum, "Detection electrode motion noise in ECG signals by monitoring electrode impedance," in Proc. Comput. Cardiol., 1984, pp. 1-4.
    • (1984) Proc. Comput. Cardiol , pp. 1-4
    • Devlin, P.H.1    Mark, R.G.2    Ketchum, J.W.3
  • 21
    • 0034478046 scopus 로고    scopus 로고
    • Comparison of methods for adaptive removal of motion artifact
    • P. Hamilton, M. Curley, R. Aimi, and C. Sae-Hau, "Comparison of methods for adaptive removal of motion artifact," in Proc. Comput. Cardiol., vol. 27. 2000, pp. 383-386. (Pubitemid 32188113)
    • (2000) Computers in Cardiology , pp. 383-386
    • Hamilton, P.S.1    Curley, M.G.2    Aimi, R.M.3    Sae-Hau, C.4
  • 23
    • 78650882594 scopus 로고    scopus 로고
    • A 30 μw analog signal processor ASIC for portable biopotential signal monitoring
    • Jan.
    • R. F. Yazicioglu, S. Kim, T. Torfs, H. Kim, and C. Van Hoof, "A 30 μW analog signal processor ASIC for portable biopotential signal monitoring," IEEE J. Solid-State Circuits, vol. 46, no. 1, pp. 209-223, Jan. 2011.
    • (2011) IEEE J. Solid-State Circuits , vol.46 , Issue.1 , pp. 209-223
    • Yazicioglu, R.F.1    Kim, S.2    Torfs, T.3    Kim, H.4    Van Hoof, C.5
  • 24
    • 77958021201 scopus 로고    scopus 로고
    • A 2.4 μa continuous-time electrode-skin impedance measurement circuit for motion artifact monitoring in ECG acquisition systems
    • Jun
    • S. Kim, R. Yazicioglu, T. Torfs, D. Buxi, J. Penders, and C. Van Hoof, "A 2.4 μA continuous-time electrode-skin impedance measurement circuit for motion artifact monitoring in ECG acquisition systems," in Proc. IEEE Symp. VLSI Circuits, Jun. 2010, pp. 219-220.
    • (2010) Proc. IEEE Symp. VLSI Circuits , pp. 219-220
    • Kim, S.1    Yazicioglu, R.2    Torfs, T.3    Buxi, D.4    Penders, J.5    Van Hoof, C.6
  • 26
    • 0343399541 scopus 로고
    • The origin of skin potential and its variations
    • N. Thakor and J. Webster, "The origin of skin potential and its variations," in Proc. Ann. Conf. Eng. Biol. Med., vol. 20. 1978, p. 212.
    • (1978) Proc. Ann. Conf. Eng. Biol. Med , vol.20 , pp. 212
    • Thakor, N.1    Webster, J.2
  • 27
    • 0015595467 scopus 로고
    • Local electrical response of the skin to deformation
    • R. Edelberg, "Local electrical response of the skin to deformation," J. Appl. Physiol., vol. 34, no. 3, pp. 334-340, 1973.
    • (1973) J. Appl. Physiol , vol.34 , Issue.3 , pp. 334-340
    • Edelberg, R.1
  • 28
    • 0029974333 scopus 로고    scopus 로고
    • The origin of skin-stretch-caused motion artifacts under electrodes
    • DOI 10.1088/0967-3334/17/2/003
    • H. de Talhouet and J. G. Webster, "The origin of skin-stretch-caused motion artifacts under electrodes," Physiol. Meas., vol. 17, no. 2, pp. 81-93, 1996. (Pubitemid 26178576)
    • (1996) Physiological Measurement , vol.17 , Issue.2 , pp. 81-93
    • De Talhouet, H.1    Webster, J.G.2
  • 29
    • 78650317618 scopus 로고    scopus 로고
    • Dry-contact and noncontact biopotential electrodes: Methodological review
    • Oct
    • Y. M. Chi, T.-P. Jung, and G. Cauwenberghs, "Dry-contact and noncontact biopotential electrodes: Methodological review," IEEE Rev. Biomed. Eng., vol. 3, pp. 106-119, Oct. 2010.
    • (2010) IEEE Rev. Biomed. Eng , vol.3 , pp. 106-119
    • Chi, Y.M.1    Jung, T.-P.2    Cauwenberghs, G.3
  • 30
    • 0016938239 scopus 로고
    • Electrical properties of the epidermal stratum corneum
    • T. Yamamoto and Y. Yamamoto, "Electrical properties of the epidermal stratum corneum," Med. Biol. Eng. Comput., vol. 14, no. 2, pp. 151-158, 1976.
    • (1976) Med. Biol. Eng. Comput , vol.14 , Issue.2 , pp. 151-158
    • Yamamoto, T.1    Yamamoto, Y.2
  • 33
    • 80052835872 scopus 로고    scopus 로고
    • Comparison of ECG signal quality between a novel dry electrode and a standard gel electrode
    • Dec
    • K. Sparks and A. Rood, "Comparison of ECG signal quality between a novel dry electrode and a standard gel electrode," Med. Sci. Sports Exercise, vol. 38, p. 284, Dec. 2006.
    • (2006) Med. Sci. Sports Exercise , vol.38 , pp. 284
    • Sparks, K.1    Rood, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.