메뉴 건너뛰기




Volumn 76, Issue 12, 2012, Pages 2822-2831

Quantitative optical frequency domain imaging assessment of in-stent structures in patients with ST-segment elevation myocardial infarction: Impact of imaging sampling rate

Author keywords

Acute myocardial infarction; Coronary artery disease; Coronary thrombosis; Optical coherence tomography; Prolapse

Indexed keywords

CONTRAST MEDIUM; UMIROLIMUS;

EID: 84870496028     PISSN: 13469843     EISSN: 13474820     Source Type: Journal    
DOI: 10.1253/circj.CJ-12-0536     Document Type: Article
Times cited : (11)

References (37)
  • 1
    • 0035960591 scopus 로고    scopus 로고
    • Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: Comparison with intravascular ultrasound
    • Jang IK, Tearney G, Bouma B. Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: Comparison with intravascular ultrasound. Circulation 2001; 104: 2754.
    • (2754) Circulation , vol.2001 , pp. 104
    • Jang, I.K.1    Tearney, G.2    Bouma, B.3
  • 2
    • 0037138571 scopus 로고    scopus 로고
    • Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound
    • Jang IK, Bouma BE, Kang DH, Park SJ, Park SW, Seung KB, et al. Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound. J Am Coll Cardiol 2002; 39: 604-609.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 604-609
    • Jang, I.K.1    Bouma, B.E.2    Kang, D.H.3    Park, S.J.4    Park, S.W.5    Seung, K.B.6
  • 5
    • 77957155479 scopus 로고    scopus 로고
    • Second-generation optical coherence tomography in clinical practice: High-speed data acquisition is highly reproducible in patients undergoing percutaneous coronary intervention
    • Gonzalo N, Tearney GJ, Serruys PW, van Soest G, Okamura T, Garcia-Garcia HM, et al. Second-generation optical coherence tomography in clinical practice: High-speed data acquisition is highly reproducible in patients undergoing percutaneous coronary intervention. Rev Esp Cardiol 2010; 63: 893-903.
    • (2010) Rev Esp Cardiol , vol.63 , pp. 893-903
    • Gonzalo, N.1    Tearney, G.J.2    Serruys, P.W.3    van Soest, G.4    Okamura, T.5    Garcia-Garcia, H.M.6
  • 6
    • 76049118483 scopus 로고    scopus 로고
    • Advantage of next-generation frequency-domain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion
    • Takarada S, Imanishi T, Liu Y, Ikejima H, Tsujioka H, Kuroi A, et al. Advantage of next-generation frequency-domain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion. Catheter Cardiovasc Interv 2010; 75: 202-206.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 202-206
    • Takarada, S.1    Imanishi, T.2    Liu, Y.3    Ikejima, H.4    Tsujioka, H.5    Kuroi, A.6
  • 7
    • 79952796067 scopus 로고    scopus 로고
    • Reproducibility of coronary Fourier domain optical coherence tomography: Quantitative analysis of in vivo stented coronary arteries using three different software packages
    • Okamura T, Gonzalo N, Gutierrez-Chico JL, Serruys PW, Bruining N, de Winter S, et al. Reproducibility of coronary Fourier domain optical coherence tomography: Quantitative analysis of in vivo stented coronary arteries using three different software packages. EuroInter-vention 2010; 6: 371-379.
    • (2010) EuroInter-vention , vol.6 , pp. 371-379
    • Okamura, T.1    Gonzalo, N.2    Gutierrez-Chico, J.L.3    Serruys, P.W.4    Bruining, N.5    de Winter, S.6
  • 8
    • 4644298765 scopus 로고    scopus 로고
    • Motion artifacts in optical coherence tomography with frequency-domain ranging
    • Yun SH, Tearney G, de Boer J, Bouma B. Motion artifacts in optical coherence tomography with frequency-domain ranging. Opt Express 2004; 12: 2977-2998.
    • (2004) Opt Express , vol.12 , pp. 2977-2998
    • Yun, S.H.1    Tearney, G.2    de Boer, J.3    Bouma, B.4
  • 10
    • 74549129104 scopus 로고    scopus 로고
    • An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: A LEADERS trial sub-study
    • Barlis P, Regar E, Serruys PW, Dimopoulos K, van der Giessen WJ, van Geuns RJ, et al. An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: A LEADERS trial sub-study. Eur Heart J 2010; 31: 165-176.
    • (2010) Eur Heart J , vol.31 , pp. 165-176
    • Barlis, P.1    Regar, E.2    Serruys, P.W.3    Dimopoulos, K.4    van der, G.W.J.5    van Geuns, R.J.6
  • 11
    • 80054071576 scopus 로고    scopus 로고
    • Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fuoropolymer-coated everolimus-eluting stent at 13-month follow-up: An optical coherence tomography substudy from the RESOLUTE All Comers trial
    • Gutierrez-Chico JL, van Geuns RJ, Regar E, van der Giessen WJ, Kelbaek H, Saunamaki K, et al. Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fuoropolymer-coated everolimus-eluting stent at 13-month follow-up: An optical coherence tomography substudy from the RESOLUTE All Comers trial. Eur Heart J 2011; 32: 2454-2463.
    • (2011) Eur Heart J , vol.32 , pp. 2454-2463
    • Gutierrez-Chico, J.L.1    van Geuns, R.J.2    Regar, E.3    van der, G.W.J.4    Kelbaek, H.5    Saunamaki, K.6
  • 12
    • 79960922968 scopus 로고    scopus 로고
    • First-in-man evaluation of intra-vascular optical frequency domain imaging (OFDI) of Terumo: A comparison with intravascular ultrasound and quantitative coronary angiography
    • Okamura T, Onuma Y, Garcia-Garcia HM, van Geuns RJ, Wykrzykowska JJ, Schultz C, et al. First-in-man evaluation of intra-vascular optical frequency domain imaging (OFDI) of Terumo: A comparison with intravascular ultrasound and quantitative coronary angiography. EuroIntervention 2011; 6: 1037-1045.
    • (2011) EuroIntervention , vol.6 , pp. 1037-1045
    • Okamura, T.1    Onuma, Y.2    Garcia-Garcia, H.M.3    van Geuns, R.J.4    Wykrzykowska, J.J.5    Schultz, C.6
  • 13
    • 80052998014 scopus 로고    scopus 로고
    • Serial analysis of the malapposed and uncovered struts of the new generation of everolimus-eluting bioresorbable scaffold with optical coherence tomography
    • Gomez-Lara J, Radu M, Brugaletta S, Farooq V, Diletti R, Onuma Y, et al. Serial analysis of the malapposed and uncovered struts of the new generation of everolimus-eluting bioresorbable scaffold with optical coherence tomography. JACC Cardiovasc Interv 2011; 4: 992-1001.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 992-1001
    • Gomez-Lara, J.1    Radu, M.2    Brugaletta, S.3    Farooq, V.4    Diletti, R.5    Onuma, Y.6
  • 14
    • 79251536249 scopus 로고    scopus 로고
    • Strut coverage and late malapposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: Optical coherence tomography substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial
    • Guagliumi G, Costa MA, Sirbu V, Musumeci G, Bezerra HG, Suzuki N, et al. Strut coverage and late malapposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: Optical coherence tomography substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial. Circulation 2011; 123: 274-281.
    • (2011) Circulation , vol.123 , pp. 274-281
    • Guagliumi, G.1    Costa, M.A.2    Sirbu, V.3    Musumeci, G.4    Bezerra, H.G.5    Suzuki, N.6
  • 15
    • 79961200594 scopus 로고    scopus 로고
    • Optical coherence tomography endpoints in stent clinical investigations: Strut coverage
    • Tahara S, Chamie D, Baibars M, Alraies C, Costa M. Optical coherence tomography endpoints in stent clinical investigations: Strut coverage. Int J Cardiovasc Imaging 2011; 27: 271-287.
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 271-287
    • Tahara, S.1    Chamie, D.2    Baibars, M.3    Alraies, C.4    Costa, M.5
  • 16
    • 72049132593 scopus 로고    scopus 로고
    • Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: A systematic quantitative approach
    • Gonzalo N, Serruys PW, Okamura T, Shen ZJ, Onuma Y, Garcia-Garcia HM, et al. Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: A systematic quantitative approach. Heart 2009; 95: 1913-1919.
    • (2009) Heart , vol.95 , pp. 1913-1919
    • Gonzalo, N.1    Serruys, P.W.2    Okamura, T.3    Shen, Z.J.4    Onuma, Y.5    Garcia-Garcia, H.M.6
  • 17
    • 0345373979 scopus 로고    scopus 로고
    • Evaluation of coronary remodeling after sirolimus-eluting stent implantation by serial three-dimensional intravascular ultrasound
    • Degertekin M, Regar E, Tanabe K, Lemos P, Lee CH, Smits P, et al. Evaluation of coronary remodeling after sirolimus-eluting stent implantation by serial three-dimensional intravascular ultrasound. Am J Cardiol 2003; 91: 1046-1050.
    • (2003) Am J Cardiol , vol.91 , pp. 1046-1050
    • Degertekin, M.1    Regar, E.2    Tanabe, K.3    Lemos, P.4    Lee, C.H.5    Smits, P.6
  • 18
    • 67651089942 scopus 로고    scopus 로고
    • MAHOROBA, frst-in-man study: 6-month results of a bio-degradable polymer sustained release tacrolimus-eluting stent in de novo coronary stenoses
    • Onuma Y, Serruys PW, den Heijer P, Joesoef KS, Duckers H, Regar E, et al. MAHOROBA, frst-in-man study: 6-month results of a bio-degradable polymer sustained release tacrolimus-eluting stent in de novo coronary stenoses. Eur Heart J 2009; 30: 1477-1485.
    • (2009) Eur Heart J , vol.30 , pp. 1477-1485
    • Onuma, Y.1    Serruys, P.W.2    den, H.P.3    Joesoef, K.S.4    Duckers, H.5    Regar, E.6
  • 19
    • 77249092502 scopus 로고    scopus 로고
    • Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: Physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis
    • Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang IK, et al. Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: Physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 2010; 31: 401-415.
    • (2010) Eur Heart J , vol.31 , pp. 401-415
    • Prati, F.1    Regar, E.2    Mintz, G.S.3    Arbustini, E.4    Di, M.C.5    Jang, I.K.6
  • 20
    • 0024521543 scopus 로고
    • A concordance correlation coeffcient to evaluate reproduc-ibility
    • Lin LI. A concordance correlation coeffcient to evaluate reproduc-ibility. Biometrics 1989; 45: 255-268.
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 21
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 0002363710 scopus 로고
    • A note on normal correlation
    • Pitman EJG. A note on normal correlation. Biometrika 1939; 31: 9-12.
    • (1939) Biometrika , vol.31 , pp. 9-12
    • Pitman, E.J.G.1
  • 23
    • 0002829661 scopus 로고
    • A test for the signifcance of the difference between the two variances in a sample from a normal bivariate population
    • Morgan WA. A test for the signifcance of the difference between the two variances in a sample from a normal bivariate population. Biometrika 1939; 31: 13-19.
    • (1939) Biometrika , vol.31 , pp. 13-19
    • Morgan, W.A.1
  • 24
    • 84863569621 scopus 로고
    • Thrombotic arch in ST-segment elevation myocardial infarction: Comparison between two-dimensional and three-dimensional optical frequency domain imaging
    • Muramatsu T, Serruys PW, Onuma Y. Thrombotic arch in ST-segment elevation myocardial infarction: Comparison between two-dimensional and three-dimensional optical frequency domain imaging. Eur Heart J 2012; 33: 1510.
    • (1510) Eur Heart J , vol.2012 , pp. 33
    • Muramatsu, T.1    Serruys, P.W.2    Onuma, Y.3
  • 25
    • 34548161312 scopus 로고    scopus 로고
    • Assessment of culprit lesion morphology in acute myocardial infarction: Ability of optical coherence tomography compared with intra-vascular ultrasound and coronary angioscopy
    • Kubo T, Imanishi T, Takarada S, Kuroi A, Ueno S, Yamano T, et al. Assessment of culprit lesion morphology in acute myocardial infarction: Ability of optical coherence tomography compared with intra-vascular ultrasound and coronary angioscopy. J Am Coll Cardiol 2007; 50: 933-939.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 933-939
    • Kubo, T.1    Imanishi, T.2    Takarada, S.3    Kuroi, A.4    Ueno, S.5    Yamano, T.6
  • 26
    • 72449150228 scopus 로고    scopus 로고
    • Volumetric intravascular ultrasound analysis of Pa-clitaxel-eluting and bare metal stents in acute myocardial infarction: The harmonizing outcomes with revascularization and stents in acute myocardial infarction intravascular ultrasound substudy
    • Maehara A, Mintz GS, Lansky AJ, Witzenbichler B, Guagliumi G, Brodie B, et al. Volumetric intravascular ultrasound analysis of Pa-clitaxel-eluting and bare metal stents in acute myocardial infarction: The harmonizing outcomes with revascularization and stents in acute myocardial infarction intravascular ultrasound substudy. Circulation 2009; 120: 1875-1882.
    • (2009) Circulation , vol.120 , pp. 1875-1882
    • Maehara, A.1    Mintz, G.S.2    Lansky, A.J.3    Witzenbichler, B.4    Guagliumi, G.5    Brodie, B.6
  • 30
    • 26244449978 scopus 로고    scopus 로고
    • Effect of pravastatin on malondialdehyde-modifed low-density lipoprotein levels and coronary plaque regression as determined by three-dimensional intravascular ultrasound
    • Tani S, Watanabe I, Anazawa T, Kawamata H, Tachibana E, Furukawa K, et al. Effect of pravastatin on malondialdehyde-modifed low-density lipoprotein levels and coronary plaque regression as determined by three-dimensional intravascular ultrasound. Am J Cardiol 2005; 96: 1089-1094.
    • (2005) Am J Cardiol , vol.96 , pp. 1089-1094
    • Tani, S.1    Watanabe, I.2    Anazawa, T.3    Kawamata, H.4    Tachibana, E.5    Furukawa, K.6
  • 31
    • 0028850455 scopus 로고
    • Intravas-cular ultrasound imaging in patients with acute myocardial infarction
    • Bocksch W, Schartl M, Beckmann S, Dreysse S, Fleck E. Intravas-cular ultrasound imaging in patients with acute myocardial infarction. Eur Heart J 1995; 16(Suppl J): 46-52.
    • (1995) Eur Heart J , vol.16 , Issue.SUPPL. J , pp. 46-52
    • Bocksch, W.1    Schartl, M.2    Beckmann, S.3    Dreysse, S.4    Fleck, E.5
  • 32
    • 0033858281 scopus 로고    scopus 로고
    • Long-term outcomes of minor plaque prolapsed within stents documented with intravascular ultrasound
    • Hong MK, Park SW, Lee CW, Kang DH, Song JK, Kim JJ, et al. Long-term outcomes of minor plaque prolapsed within stents documented with intravascular ultrasound. Catheter Cardiovasc Interv 2000; 51: 22-26.
    • (2000) Catheter Cardiovasc Interv , vol.51 , pp. 22-26
    • Hong, M.K.1    Park, S.W.2    Lee, C.W.3    Kang, D.H.4    Song, J.K.5    Kim, J.J.6
  • 33
    • 33748417765 scopus 로고    scopus 로고
    • Characterization of plaque prolapse after drug-eluting stent implantation in diabetic patients: A three-dimensional volumetric intravascular ultrasound outcome study
    • Futamatsu H, Sabate M, Angiolillo DJ, Jimenez-Quevedo P, Corros C, Morikawa-Futamatsu K, et al. Characterization of plaque prolapse after drug-eluting stent implantation in diabetic patients: A three-dimensional volumetric intravascular ultrasound outcome study. J Am Coll Cardiol 2006; 48: 1139-1145.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1139-1145
    • Futamatsu, H.1    Sabate, M.2    Angiolillo, D.J.3    Jimenez-Quevedo, P.4    Corros, C.5    Morikawa-Futamatsu, K.6
  • 34
    • 47349103014 scopus 로고    scopus 로고
    • Plaque prolapse after stent implantation in patients with acute myocardial infarction: An intravascular ultrasound analysis
    • Hong YJ, Jeong MH, Ahn Y, Sim DS, Chung JW, Cho JS, et al. Plaque prolapse after stent implantation in patients with acute myocardial infarction: An intravascular ultrasound analysis. JACC Cardiovasc Imaging 2008; 1: 489-497.
    • (2008) JACC Cardiovasc Imaging , vol.1 , pp. 489-497
    • Hong, Y.J.1    Jeong, M.H.2    Ahn, Y.3    Sim, D.S.4    Chung, J.W.5    Cho, J.S.6
  • 35
    • 84860390416 scopus 로고    scopus 로고
    • Intravascular ultrasound fndings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: A Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy
    • Choi SY, Witzenbichler B, Maehara A, Lansky AJ, Guagliumi G, Brodie B, et al. Intravascular ultrasound fndings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: A Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy. Circ Cardiovasc Interv 2011; 4: 239-247.
    • (2011) Circ Cardiovasc Interv , vol.4 , pp. 239-247
    • Choi, S.Y.1    Witzenbichler, B.2    Maehara, A.3    Lansky, A.J.4    Guagliumi, G.5    Brodie, B.6
  • 36
    • 77957255702 scopus 로고    scopus 로고
    • Incidence, mechanisms, predictors, and clinical impact of acute and late stent malapposition after primary intervention in patients with acute myo-cardial infarction: An intravascular ultrasound substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myo-cardial Infarction (HORIZONS-AMI) trial
    • Guo N, Maehara A, Mintz GS, He Y, Xu K, Wu X, et al. Incidence, mechanisms, predictors, and clinical impact of acute and late stent malapposition after primary intervention in patients with acute myo-cardial infarction: An intravascular ultrasound substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myo-cardial Infarction (HORIZONS-AMI) trial. Circulation 2010; 122: 1077-1084.
    • (2010) Circulation , vol.122 , pp. 1077-1084
    • Guo, N.1    Maehara, A.2    Mintz, G.S.3    He, Y.4    Xu, K.5    Wu, X.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.