메뉴 건너뛰기




Volumn 6, Issue 3, 2010, Pages 371-379

Reproducibility of coronary Fourier domain optical coherence tomography: Quantitative analysis of in vivo stented coronary arteries using three different software packages

Author keywords

Coronary artery disease; Imaging; OCT

Indexed keywords

ADULT; AGED; ALGORITHM; ARTERY CATHETER; ARTICLE; BLOOD VESSEL DIAMETER; CALIBRATION; COMPUTER ANALYSIS; COMPUTER PROGRAM; CONTROLLED STUDY; CORONARY STENT; FEMALE; FOURIER ANALYSIS; HUMAN; IN VIVO STUDY; MAJOR CLINICAL STUDY; MALE; OPTICAL COHERENCE TOMOGRAPHY; QUANTITATIVE ANALYSIS; RELIABILITY; REPRODUCIBILITY; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; CORONARY ARTERY DISEASE; CORONARY BLOOD VESSEL; METHODOLOGY; MIDDLE AGED; PATHOLOGY;

EID: 79952796067     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV6I1A62     Document Type: Article
Times cited : (51)

References (24)
  • 5
    • 34147135208 scopus 로고    scopus 로고
    • Evaluation by Optical Coherence Tomography of Neointimal Coverage of Sirolimus-Eluting Stent Three Months after Implantation
    • DOI 10.1016/j.amjcard.2006.11.068, PII S0002914907000781
    • Takano M, Inami S, Jang I, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol. 2007;99:1033-1038. (Pubitemid 46560470)
    • (2007) American Journal of Cardiology , vol.99 , Issue.8 , pp. 1033-1038
    • Takano, M.1    Inami, S.2    Jang, I.-K.3    Yamamoto, M.4    Murakami, D.5    Seimiya, K.6    Ohba, T.7    Mizuno, K.8
  • 7
    • 55749108190 scopus 로고    scopus 로고
    • Optical coherence tomography: Clinical applications and the evaluation of des
    • Gonzalo N, Serruys PW, Regar E. Optical coherence tomography: clinical applications and the evaluation of DES. Minerva Cardioangiol. 2008;56:511-525.
    • (2008) Minerva Cardioangiol. , vol.56 , pp. 511-525
    • Gonzalo, N.1    Serruys, P.W.2    Regar, E.3
  • 9
    • 63049085973 scopus 로고    scopus 로고
    • Current and future developments in intracoronary optical coherence tomography imaging
    • Barlis P, Schmitt JM. Current and future developments in intracoronary optical coherence tomography imaging. EuroIntervention. 2009;4:529-533.
    • (2009) EuroIntervention , vol.4 , pp. 529-533
    • Barlis, P.1    Schmitt, J.M.2
  • 11
    • 38549136735 scopus 로고    scopus 로고
    • In-vivo validation of a novel three-dimensional quantitative coronary angiography system (CardioOp-B™): Comparison with a conventional two-dimensional system (CASS II™) and with special reference to optical coherence tomography
    • Tsuchida K, vd Giessen W, Patterson M, Tanimoto S, Garcia-Garcia H, Regar E, Ligthart J, Maugenest AM, Maatrijk G, Wentzel JJ, Serruys P.W. In-vivo validation of a novel three-dimensional quantitative coronary angiography system (CardioOp-B™): Comparison with a conventional two-dimensional system (CASS II™) and with special reference to optical coherence tomography. EuroIntervention. 2007;3:100-108.
    • (2007) EuroIntervention , vol.3 , pp. 100-108
    • Tsuchida, K.1    Vd Giessen, W.2    Patterson, M.3    Tanimoto, S.4    Garcia-Garcia, H.5    Regar, E.6    Ligthart, J.7    Maugenest, A.M.8    Maatrijk, G.9    Wentzel, J.J.10    Serruys, P.W.11
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0029955330 scopus 로고    scopus 로고
    • In vivo validation of intravascular ultrasound length measurements using a motorized transducer pullback system
    • Fuessl RT, Mintz GS, Pichard AD, Kent KM, Satler LF, Popma JJ, Leon MB. In vivo validation of intravascular ultrasound length measurements using a motorized transducer pullback system. Am J Cardiol. 1996;77:1115-1118.
    • (1996) Am J Cardiol , vol.77 , pp. 1115-1118
    • Fuessl, R.T.1    Mintz, G.S.2    Pichard, A.D.3    Kent, K.M.4    Satler, L.F.5    Popma, J.J.6    Leon, M.B.7
  • 19
    • 45949089532 scopus 로고    scopus 로고
    • An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets
    • DOI 10.1088/0031-9155/53/12/001, PII S0031915508702434
    • Bonnema GT, Cardinal KO, Williams SK, Barton JK. An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets. Phys Med Biol. 2008;53:3083-3098. (Pubitemid 351892388)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.12 , pp. 3083-3098
    • Bonnema, G.T.1    Cardinal, K.O.2    Williams, S.K.3    Barton, J.K.4
  • 20
    • 0028415619 scopus 로고
    • Preliminary experience with intravascular ultrasound guided Palmaz-Schatz coronary stenting: The acute and short-term results on a consecutive series of patients
    • Hall P, Colombo A, Almagor Y, Maiello L, Nakamura S, Martini G, Tobis JM. Preliminary experience with intravascular ultrasound guided Palmaz-Schatz coronary stenting: the acute and short-term results on a consecutive series of patients. J Interv Cardiol. 1994;7:141-159.
    • (1994) J Interv Cardiol , vol.7 , pp. 141-159
    • Hall, P.1    Colombo, A.2    Almagor, Y.3    Maiello, L.4    Nakamura, S.5    Martini, G.6    Tobis, J.M.7
  • 24
    • 35348829345 scopus 로고    scopus 로고
    • Features and parameters of drug-eluting stent deployment discoverable by intravascular ultrasound
    • Mintz GS. Features and parameters of drug-eluting stent deployment discoverable by intravascular ultrasound. Am J Cardiol. 2007;100:26M-35M.
    • (2007) Am J Cardiol , vol.100
    • Mintz, G.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.