메뉴 건너뛰기




Volumn 6, Issue 9, 2011, Pages 1037-1045

First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: A comparison with intravascular ultrasound and quantitative coronary angiography

Author keywords

Coronary imaging; Intravascular ultrasound; Optical coherence tomography; Optical frequency domain imaging; Stents

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; BLOOD VESSEL PARAMETERS; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY STENT; EDGE QUANTITATIVE CORONARY ANGIOGRAPHY; FEASIBILITY STUDY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE QUALITY; IMAGING; IMAGING SYSTEM; INCIDENCE; INTERMETHOD COMPARISON; INTRAVASCULAR ULTRASOUND; LUMEN AREA; MALE; MORPHOMETRICS; OPTICAL FREQUENCY DOMAIN IMAGING; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; SAFETY; TREATMENT OUTCOME; VIDEODENSITOMETRIC QUANTITATIVE CORONARY ANGIOGRAPHY; CLINICAL TRIAL; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; CONTROLLED CLINICAL TRIAL; CORONARY ARTERY DISEASE; ECHOGRAPHY; ENDOSCOPIC ECHOGRAPHY; EQUIPMENT DESIGN; FOURIER ANALYSIS; INSTRUMENTATION; METHODOLOGY; MIDDLE AGED; NETHERLANDS; OPTICAL COHERENCE TOMOGRAPHY; PATHOLOGY; PREDICTIVE VALUE; RADIOGRAPHY; STENT; TRANSLUMINAL CORONARY ANGIOPLASTY;

EID: 79960922968     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV6I9A182     Document Type: Article
Times cited : (91)

References (23)
  • 1
    • 16844385105 scopus 로고    scopus 로고
    • Review of the ability of optical coherence tomography to characterize plaque, including a comparison with intravascular ultrasound
    • DOI 10.1007/s00270-003-0021-1
    • Patel NA, Stamper DL, Brezinski ME. Review of the ability of optical coherence tomography to characterize plaque, including a comparison with intravascular ultrasound. Cardiovasc Intervent Radiol 2005;28:1-9. (Pubitemid 40487159)
    • (2005) CardioVascular and Interventional Radiology , vol.28 , Issue.1 , pp. 1-9
    • Patel, N.A.1    Stamper, D.L.2    Brezinski, M.E.3
  • 4
    • 0035312809 scopus 로고    scopus 로고
    • American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    • Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, Pinto FJ, Rosenfield K, Siegel RJ, Tuzcu EM, Yock PG. American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001;37:1478-1492.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1478-1492
    • Mintz, G.S.1    Nissen, S.E.2    Anderson, W.D.3    Bailey, S.R.4    Erbel, R.5    Fitzgerald, P.J.6    Pinto, F.J.7    Rosenfield, K.8    Siegel, R.J.9    Tuzcu, E.M.10    Yock, P.G.11
  • 8
    • 0021255972 scopus 로고
    • Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: Diameter versus densitometric area measurements
    • Serruys PW, Reiber JH, Wijns W, van den Brand M, Kooijman CJ, ten Katen HJ, Hugenholtz PG. Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: diameter versus densitometric area measurements. Am J Cardiol 1984;54:482-488. (Pubitemid 14073230)
    • (1984) American Journal of Cardiology , vol.54 , Issue.6 , pp. 482-488
    • Serruys, P.W.1    Reiber, J.H.C.2    Wijns, W.3
  • 13
    • 65549170720 scopus 로고    scopus 로고
    • Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: Insights from optical coherence tomography
    • Gonzalo N, Barlis P, Serruys PW, Garcia-Garcia HM, Onuma Y, Ligthart J, Regar E. Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherence tomography. JACC Cardiovasc Interv 2009;2:445-452.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 445-452
    • Gonzalo, N.1    Barlis, P.2    Serruys, P.W.3    Garcia-Garcia, H.M.4    Onuma, Y.5    Ligthart, J.6    Regar, E.7
  • 14
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 77955474924 scopus 로고    scopus 로고
    • Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation
    • Capodanno D, Prati F, Pawlowsky T, Cera M, La Manna A, Albertucci M, Tamburino C. Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation. EuroIntervention 2009:5:538-543.
    • (2009) EuroIntervention , vol.5 , pp. 538-543
    • Capodanno, D.1    Prati, F.2    Pawlowsky, T.3    Cera, M.4    La Manna, A.5    Albertucci, M.6    Tamburino, C.7
  • 19
  • 21
    • 0037310874 scopus 로고    scopus 로고
    • Influence of coronary pulsation on volumetric intravascular ultrasound measurements performed without ECG-gating. Validation in vessel segments with minimal disease.
    • DOI 10.1023/A:1021784107536
    • Tsutsui H, Schoenhagen P, Crowe TD, Klingensmith JD, Vince DG, Nissen SE, Tuzcu EM. Influence of coronary pulsation on volumetric intravascular ultrasound measurements performed without ECG-gating. Validation in vessel segments with minimal disease. Int J Cardiovasc Imaging 2003;19:51-57. (Pubitemid 36167992)
    • (2003) International Journal of Cardiovascular Imaging , vol.19 , Issue.1 , pp. 51-57
    • Tsutsui, H.1    Schoenhagen, P.2    Crowe, T.D.3    Klingensmith, J.D.4    Vince, D.G.5    Nissen, S.E.6    Tuzcu, E.M.7
  • 22
    • 0032694295 scopus 로고    scopus 로고
    • Axial movement of the intravascular ultrasound probe during the cardiac cycle: Implications for three-dimensional reconstruction and measurements of coronary dimensions
    • DOI 10.1016/S0002-8703(99)70011-6
    • Arbab-Zadeh A, DeMaria AN, Penny WF, Russo RJ, Kimura BJ, Bhargava V. Axial movement of the intravascular ultrasound probe during the cardiac cycle: implications for three-dimensional reconstruction and measurements of coronary dimensions. Am. Heart J 1999;138:865-872. (Pubitemid 29523273)
    • (1999) American Heart Journal , vol.138 , Issue.5 I , pp. 865-872
    • Arbab-Zadeh, A.1    DeMaria, A.N.2    Penny, W.F.3    Russo, R.J.4    Kimura, B.J.5    Bhargava, V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.