메뉴 건너뛰기




Volumn 57, Issue 24, 2012, Pages 8173-8184

Visualization of small lesions in rat cartilage by means of laboratory-based x-ray phase contrast imaging

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL MODEL; ARTICULAR CARTILAGES; CARTILAGE PATHOLOGY; CODED-APERTURE; GRATING INTERFEROMETRY; HIGH-THROUGHPUT; HIGHER RESOLUTION; IMAGING TECHNOLOGY; LABORATORY SET-UP; LABORATORY SYSTEM; MICRO CT; MOUSE CARTILAGE; NON DESTRUCTIVE; PHASE METHODS; PHASE SENSITIVITY; PRE-CLINICAL; PROOF OF CONCEPT; RAT TIBIA; RESEARCH TOOLS; RODENT MODELS; SALINE SOLUTIONS; SMALL LESIONS; STRUCTURAL CHANGE; STRUCTURAL IMAGING; X-RAY PHASE-CONTRAST IMAGING;

EID: 84870322721     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/24/8173     Document Type: Article
Times cited : (52)

References (48)
  • 1
    • 79952781643 scopus 로고    scopus 로고
    • Cationic contrast agents improve quantification of glycosaminoglycan (GAG) content by contrast enhanced CT imaging of cartilage
    • 10.1002/jor.21312 0736-0266
    • Bansal P N, Joshi N S, Entezari V, Malone B C, Stewart R C, Snyder B D and Grinstaff M W 2011 Cationic contrast agents improve quantification of glycosaminoglycan (GAG) content by contrast enhanced CT imaging of cartilage J. Orthop. Res. 29 704-9
    • (2011) J. Orthop. Res. , vol.29 , Issue.5 , pp. 704-709
    • Bansal, P.N.1    Joshi, N.S.2    Entezari, V.3    Malone, B.C.4    Stewart, R.C.5    Snyder, B.D.6    Grinstaff, M.W.7
  • 2
    • 78149439710 scopus 로고    scopus 로고
    • A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging
    • 10.1118/1.3501311 0094-2405
    • Bennett E E, Kopace R, Stein A F and Wen H 2010 A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging Med. Phys. 37 6047-54
    • (2010) Med. Phys. , vol.37 , Issue.11 , pp. 6047-6054
    • Bennett, E.E.1    Kopace, R.2    Stein, A.F.3    Wen, H.4
  • 3
    • 0001349074 scopus 로고
    • An x-ray interferometer
    • 10.1063/1.1754212 0003-6951
    • Bonse U and Hart M 1965 An x-ray interferometer Appl. Phys. Lett. 6 155-6
    • (1965) Appl. Phys. Lett. , vol.6 , Issue.8 , pp. 155-156
    • Bonse, U.1    Hart, M.2
  • 4
    • 33747092983 scopus 로고    scopus 로고
    • Quantification of subchondral bone changes in a murine osteoarthritis model using micro-CT
    • Selected papers of the 4th International Symposium on Mechanobiology of Cartilage and Chondrocyte
    • Botter S M, van Osch G J V M, Waarsing J H, Day J S, Verhaar J A N, Pols H A P, van Leeuwen J P T M and Weinans H 2006 Quantification of subchondral bone changes in a murine osteoarthritis model using micro-CT Biorheology 43 379-88 (Pubitemid 44221919)
    • (2006) Biorheology , vol.43 , Issue.3-4 , pp. 379-388
    • Botter, S.M.1    Van Osch, G.J.V.M.2    Waarsing, J.H.3    Day, J.S.4    Verhaar, J.A.N.5    Pols, H.A.P.6    Van Leeuwen, J.P.T.M.7    Weinans, H.8
  • 5
    • 70849134020 scopus 로고    scopus 로고
    • Realization of optical carpets in the Talbot and Talbot-Lau configurations
    • 10.1364/OE.17.020966 1094-4087
    • Case W B, Tomandl M, Dechapunya S and Arndt M 2009 Realization of optical carpets in the Talbot and Talbot-Lau configurations Opt. Exp. 17 20966-74
    • (2009) Opt. Exp. , vol.17 , Issue.23 , pp. 20966-20974
    • Case, W.B.1    Tomandl, M.2    Dechapunya, S.3    Arndt, M.4
  • 7
    • 0023182211 scopus 로고
    • Bone embedding in pure methyl methacrylate at low temperature preserves enzyme activities
    • Chappard D, Palle S, Alexandre C, Vico L and Riffat G 1987 Bone embedding in pure methyl methacrylate at low temperature preserves enzyme activities Acta Histochem. 81 183-90 (Pubitemid 17079156)
    • (1987) Acta Histochemica , vol.81 , Issue.2 , pp. 183-190
    • Chappard, D.1    Palle, S.2    Alexandre, C.3
  • 9
    • 78650051967 scopus 로고    scopus 로고
    • In vivo x-ray phase contrast analyser based imaging for longitudinal osteoarthritis studies in guinea pigs
    • 10.1088/0031-9155/55/24/017 0031-9155
    • Coan P, Wagner A, Bravin A, Diemoz P C, Keryrilainen J and Mollenhauer J 2010b In vivo x-ray phase contrast analyser based imaging for longitudinal osteoarthritis studies in guinea pigs Phys. Med. Biol. 55 7649-62
    • (2010) Phys. Med. Biol. , vol.55 , Issue.24 , pp. 7649-7662
    • Coan, P.1    Wagner, A.2    Bravin, A.3    Diemoz, P.C.4    Keryrilainen, J.5    Mollenhauer, J.6
  • 10
    • 80052779630 scopus 로고    scopus 로고
    • Visualization of 3D osteon morphology by synchrotron radiation micro-CT
    • 10.1111/j.1469-7580.2011.01398.x 0021-8782
    • Cooper D M L, Erickson B, Peele A G, Hannah K, Thomas C D L and Clement J G 2011 Visualization of 3D osteon morphology by synchrotron radiation micro-CT J. Anat. 219 481-9
    • (2011) J. Anat. , vol.219 , Issue.4 , pp. 481-489
    • Cooper, D.M.L.1    Erickson, B.2    Peele, A.G.3    Hannah, K.4    Thomas, C.D.L.5    Clement, J.G.6
  • 11
    • 79957992651 scopus 로고    scopus 로고
    • Differential x-ray phase contrast imaging using a shearing interferometer
    • DOI 10.1063/1.1516611
    • David C, Nohammer B, Solak H H and Ziegler E 2002 Differential x-ray phase contrast imaging using a shearing interferometer Appl. Phys. Lett. 81 3287-9 (Pubitemid 35360566)
    • (2002) Applied Physics Letters , vol.81 , Issue.17 , pp. 3287
    • David, C.1    Nohammer, B.2    Solak, H.H.3    Ziegler, E.4
  • 12
    • 0028821597 scopus 로고
    • Phase-contrast imaging of weakly absorbing materials using hard x-rays
    • 10.1038/373595a0 0028-0836
    • Davis T J, Gao D, Gureyev T E, Stevenson A W and Wilkins S W 1995 Phase-contrast imaging of weakly absorbing materials using hard x-rays Nature 373 595-8
    • (1995) Nature , vol.373 , Issue.6515 , pp. 595-598
    • Davis, T.J.1    Gao, D.2    Gureyev, T.E.3    Stevenson, A.W.4    Wilkins, S.W.5
  • 13
    • 78650075229 scopus 로고    scopus 로고
    • Comparison of analyzer-based imaging computed tomography extraction algorithms and application to bone-cartilage imaging
    • 10.1088/0031-9155/55/24/018 0031-9155
    • Diemoz P C, Bravin A, Glaser C and Coan P 2010 Comparison of analyzer-based imaging computed tomography extraction algorithms and application to bone-cartilage imaging Phys. Med. Biol. 55 7663-80
    • (2010) Phys. Med. Biol. , vol.55 , Issue.24 , pp. 7663-7680
    • Diemoz, P.C.1    Bravin, A.2    Glaser, C.3    Coan, P.4
  • 14
    • 78049438240 scopus 로고    scopus 로고
    • BoneJ: Free and extensible bone image analysis in Image J
    • 10.1016/j.bone.2010.08.023 8756-3282
    • Doube M et al 2010 BoneJ: free and extensible bone image analysis in Image J Bone 47 1076-9
    • (2010) Bone , vol.47 , Issue.6 , pp. 1076-1079
    • Doube, M.1
  • 15
    • 33344467770 scopus 로고    scopus 로고
    • Osteoarthritis of the knee
    • DOI 10.1056/NEJMcp051726
    • Felson D T 2006 Osteoarthritis of the knee New Engl. J. Med. 354 841-8 (Pubitemid 43290922)
    • (2006) New England Journal of Medicine , vol.354 , Issue.8 , pp. 841-848
    • Felson, D.T.1
  • 16
    • 84984376267 scopus 로고
    • Double crystal diffractometry for the characterization of targets for laser fusion experiments
    • 10.1002/crat.19800150812 0023-4753
    • Förster E, Goetz K and Zamumseil P 1980 Double crystal diffractometry for the characterization of targets for laser fusion experiments Krist. Tech. 15 937-45
    • (1980) Krist. Tech. , vol.15 , Issue.8 , pp. 937-945
    • Förster, E.1    Goetz, K.2    Zamumseil, P.3
  • 17
    • 77956924858 scopus 로고    scopus 로고
    • The OARSI histopathology initiative - Recommendations for histological assessments of osteoarthritis in the mouse
    • 10.1016/j.joca.2010.05.025 1063-4584
    • Glasson S S, Chambers M G, Van Den Berg W B and Little C B 2010 The OARSI histopathology initiative - recommendations for histological assessments of osteoarthritis in the mouse Osteoarthritis Cartilage 18 (Suppl. 3) S17-23
    • (2010) Osteoarthritis Cartilage , vol.18 , pp. 17
    • Glasson, S.S.1    Chambers, M.G.2    Van Den Berg, W.B.3    Little, C.B.4
  • 18
    • 84864382890 scopus 로고    scopus 로고
    • High resolution micro arthrography of hard and soft tissues in a murine model
    • 10.1016/j.joca.2012.05.004 1063-4584
    • Gu X I et al 2012 High resolution micro arthrography of hard and soft tissues in a murine model Osteoarthritis Cartilage 20 1011-9
    • (2012) Osteoarthritis Cartilage , vol.20 , Issue.9 , pp. 1011-1019
    • Gu, X.I.1
  • 19
    • 84868368410 scopus 로고    scopus 로고
    • Multiscale mechanics of articular cartilage: Potentials and challenges of coupling musculoskeletal, joint, and microscale computational models
    • 10.1007/s10439-012-0598-0 0090-6964
    • Halloran J P, Sibole S, van Donkelaar C C, van Turnhout M C, Oomens C W J, Weiss J A, Guilak F and Erdemir A 2012 Multiscale mechanics of articular cartilage: potentials and challenges of coupling musculoskeletal, joint, and microscale computational models Ann. Biomed. Eng. 40 2456-74
    • (2012) Ann. Biomed. Eng. , vol.40 , Issue.11 , pp. 2456-2474
    • Halloran, J.P.1    Sibole, S.2    Van Donkelaar, C.C.3    Van Turnhout, M.C.4    Oomens, C.W.J.5    Weiss, J.A.6    Guilak, F.7    Erdemir, A.8
  • 20
    • 31544452086 scopus 로고    scopus 로고
    • Characterization of articular cartilage and subchondral bone changes in the rat anterior cruciate ligament transection and meniscectomized models of osteoarthritis
    • DOI 10.1016/j.bone.2005.08.007, PII S8756328205003352
    • Hayami T, Pickarski M, Zhuo Y, Wesolowski G A, Rodan G A and Duong L T 2006 Characterization of articular cartilage and subchondral bone changes in the rat anterior cruciate ligament transection and meniscectomized models of osteoarthritis Bone 38 234-43 (Pubitemid 43165790)
    • (2006) Bone , vol.38 , Issue.2 , pp. 234-243
    • Hayami, T.1    Pickarski, M.2    Zhuo, Y.3    Wesolowski, G.A.4    Rodan, G.A.5    Duong, L.T.6
  • 21
    • 84943271731 scopus 로고
    • X-ray plane-wave topography observation of the phase contrast from a non-crystalline object
    • 10.1088/0022-3727/28/11/012 0022-3727
    • Ingal V N and Beliaevskaya E A 1995 X-ray plane-wave topography observation of the phase contrast from a non-crystalline object J. Phys. D: Appl. Phys. 28 2314-17
    • (1995) J. Phys. D: Appl. Phys. , vol.28 , Issue.11 , pp. 2314-2317
    • Ingal, V.N.1    Beliaevskaya, E.A.2
  • 22
    • 79958859227 scopus 로고    scopus 로고
    • Bone cartilage imaging with x-ray interferometry using a practical x-ray tube
    • 10.1117/12.843655 0277-786X
    • Kido K, Makifuchi C, Kiyohara J, Itou T, Honda C and Momose A 2010 Bone cartilage imaging with x-ray interferometry using a practical x-ray tube Proc. SPIE 7622 76224O
    • (2010) Proc. SPIE , vol.7622
    • Kido, K.1    Makifuchi, C.2    Kiyohara, J.3    Itou, T.4    Honda, C.5    Momose, A.6
  • 23
    • 38149052992 scopus 로고    scopus 로고
    • Estimates of the prevalence of arthritis and other rheumatic conditions in the United States: Part II
    • 10.1002/art.23176 0004-3591
    • Lawrence R C et al 2008 Estimates of the prevalence of arthritis and other rheumatic conditions in the United States: part II Arthritis Rheum. 58 26-35
    • (2008) Arthritis Rheum. , vol.58 , Issue.1 , pp. 26-35
    • Lawrence, R.C.1
  • 24
    • 73049118565 scopus 로고    scopus 로고
    • Articular cartilage imaging by the use of phase-contrast tomography in a collagen-induced arthritis mouse model
    • 10.1016/j.acra.2009.09.015 1076-6332
    • Lee S K et al 2010 Articular cartilage imaging by the use of phase-contrast tomography in a collagen-induced arthritis mouse model Acad. Radiol. 17 244-50
    • (2010) Acad. Radiol. , vol.17 , Issue.2 , pp. 244-250
    • Lee, S.K.1
  • 25
    • 77951110158 scopus 로고    scopus 로고
    • Is cartilage matrix breakdown an appropriate therapeutic target in osteoarthritis - Insights from studies of aggrecan and collagen proteolysis
    • 10.2174/138945010791011956 1389-4501
    • Little C B and Fosang A J 2010 Is cartilage matrix breakdown an appropriate therapeutic target in osteoarthritis - insights from studies of aggrecan and collagen proteolysis Curr. Drug. Targets 11 561-75
    • (2010) Curr. Drug. Targets , vol.11 , Issue.5 , pp. 561-575
    • Little, C.B.1    Fosang, A.J.2
  • 26
    • 4444251143 scopus 로고    scopus 로고
    • Diffraction enhanced imaging of articular cartilage and comparison with micro-computed tomography of the underlying bone structure
    • Majumdar S, Issever A S, Burghardt A, Lotz J, Arfelli F, Rigon L, Heitner G and Menk R H 2004 Diffraction enhanced imaging of articular cartilage and comparison with micro-computed tomography of the underlying bone structure Eur. Radiat. 14 1440-8 (Pubitemid 39162226)
    • (2004) European Radiology , vol.14 , Issue.8 , pp. 1440-1448
    • Majumdar, S.1    Issever, A.S.2    Burghardt, A.3    Lotz, J.4    Arfelli, F.5    Rigon, L.6    Heitner, G.7    Menk, R.-H.8
  • 29
    • 0029954434 scopus 로고    scopus 로고
    • Phase-contrast X-ray computed tomography for observing biological soft tissues
    • DOI 10.1038/nm0496-473
    • Momose A, Takeda T, Itai Y and Hirano K 1996 Phase-contrast x-ray computed tomography for observing biological soft tissues Nature Med. 2 473-5 (Pubitemid 26191922)
    • (1996) Nature Medicine , vol.2 , Issue.4 , pp. 473-475
    • Momose, A.1    Takeda, T.2    Itai, Y.3    Hirako, K.4
  • 31
    • 67649804863 scopus 로고    scopus 로고
    • Diffraction-enhanced imaging of muscoskeletal tissues using a conventional x-ray tube
    • 10.1016/j.acra.2009.04.006 1076-6332
    • Muehleman C, Li J, Connor D, Parham C, Pisano E and Zhong Z 2009 Diffraction-enhanced imaging of muscoskeletal tissues using a conventional x-ray tube Acad. Radiol. 16 918-23
    • (2009) Acad. Radiol. , vol.16 , Issue.8 , pp. 918-923
    • Muehleman, C.1    Li, J.2    Connor, D.3    Parham, C.4    Pisano, E.5    Zhong, Z.6
  • 32
    • 77749289084 scopus 로고    scopus 로고
    • The relationship between wave and geometrical optics models of coded aperture type x-ray phase contrast imaging systems
    • 10.1364/OE.18.004103 1094-4087
    • Munro P R T, Ignatyev K, Speller R D and Olivo A 2010 The relationship between wave and geometrical optics models of coded aperture type x-ray phase contrast imaging systems Opt. Exp. 18 4103-17
    • (2010) Opt. Exp. , vol.18 , Issue.5 , pp. 4103-4117
    • Munro, P.R.T.1    Ignatyev, K.2    Speller, R.D.3    Olivo, A.4
  • 33
    • 59349114117 scopus 로고    scopus 로고
    • A non-free-space propagation x-ray phase contrast imaging method sensitive to phase effects in two directions simultaneously
    • 10.1063/1.3078410 0003-6951 044108
    • Olivo A, Bohndiek S E, Griffiths J A, Konstantinidis A C and Speller R D 2009 A non-free-space propagation x-ray phase contrast imaging method sensitive to phase effects in two directions simultaneously Appl. Phys. Lett. 94 044108
    • (2009) Appl. Phys. Lett. , vol.94 , Issue.4
    • Olivo, A.1    Bohndiek, S.E.2    Griffiths, J.A.3    Konstantinidis, A.C.4    Speller, R.D.5
  • 34
    • 79958735221 scopus 로고    scopus 로고
    • Noninterferometric phase-contrast images obtained with incoherent x-ray sources
    • 10.1364/AO.50.001765 0003-6935
    • Olivo A, Ignatyev K, Munro P R T and Speller R D 2011 Noninterferometric phase-contrast images obtained with incoherent x-ray sources Appl. Opt. 50 1765-9
    • (2011) Appl. Opt. , vol.50 , Issue.12 , pp. 1765-1769
    • Olivo, A.1    Ignatyev, K.2    Munro, P.R.T.3    Speller, R.D.4
  • 35
    • 34548046244 scopus 로고    scopus 로고
    • A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources
    • DOI 10.1063/1.2772193
    • Olivo A and Speller R 2007a A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources Appl. Phys. Lett. 91 074106 (Pubitemid 47283627)
    • (2007) Applied Physics Letters , vol.91 , Issue.7 , pp. 074106
    • Olivo, A.1    Speller, R.2
  • 36
    • 35848943282 scopus 로고    scopus 로고
    • Modelling of a novel x-ray phase contrast imaging technique based on coded apertures
    • DOI 10.1088/0031-9155/52/22/001, PII S0031915507563487
    • Olivo A and Speller R 2007b Modelling of a novel x-ray phase contrast imaging technique based on coded apertures Phys. Med. Biol. 52 6555-73 (Pubitemid 350058947)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.22 , pp. 6555-6573
    • Olivo, A.1    Speller, R.2
  • 37
    • 58149267911 scopus 로고    scopus 로고
    • Image formation principles in coded-aperture based x-ray phase contrast imaging
    • 10.1088/0031-9155/53/22/012 0031-9155
    • Olivo A and Speller R 2008 Image formation principles in coded-aperture based x-ray phase contrast imaging Phys. Med. Biol. 53 6461-74
    • (2008) Phys. Med. Biol. , vol.53 , Issue.22 , pp. 6461-6474
    • Olivo, A.1    Speller, R.2
  • 38
    • 70349773421 scopus 로고    scopus 로고
    • Deconvolution of x-ray phase contrast images as a way to retrieve phase information lost due to insufficient resolution
    • 0031-9155 N02
    • Olivo A and Speller R 2009 Deconvolution of x-ray phase contrast images as a way to retrieve phase information lost due to insufficient resolution Phys. Med. Biol. 54 N347-54
    • (2009) Phys. Med. Biol. , vol.54 , Issue.15
    • Olivo, A.1    Speller, R.2
  • 39
    • 0033710972 scopus 로고    scopus 로고
    • Experimental evaluation of a simple algorithm to enhance the spatial resolution in scanned radiographic systems
    • 10.1118/1.1318219 0094-2405
    • Olivo A et al 2000 Experimental evaluation of a simple algorithm to enhance the spatial resolution in scanned radiographic systems Med. Phys. 27 2609-16
    • (2000) Med. Phys. , vol.27 , Issue.11 , pp. 2609-2616
    • Olivo, A.1
  • 42
    • 33645795432 scopus 로고    scopus 로고
    • Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
    • DOI 10.1038/nphys265, PII N265
    • Pfeiffer F, Weitkamp T, Bunk O and David C 2006 Phase retrieval and differential phase-contrast imaging with low-brilliance x-ray sources Nat. Phys. 2 258-61 (Pubitemid 43553647)
    • (2006) Nature Physics , vol.2 , Issue.4 , pp. 258-261
    • Pfeiffer, F.1    Weitkamp, T.2    Bunk, O.3    David, C.4
  • 43
    • 4544330465 scopus 로고    scopus 로고
    • Micro-computed tomography - Current status and developments
    • DOI 10.1146/annurev.bioeng.6.040803.140130
    • Ritman E L 2004 Micro-computed tomography-current status and developments Annu. Rev. Biomed. Eng. 6 185-208 (Pubitemid 39213986)
    • (2004) Annual Review of Biomedical Engineering , vol.6 , pp. 185-208
    • Ritman, E.L.1
  • 44
    • 0029532089 scopus 로고
    • On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation
    • 10.1063/1.1146073 0034-6748
    • Snigirev A, Snigireva I, Kohn V, Kuznetsov S and Schelokov I 1995 On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation Rev. Sci. Instrum. 66 5486-92
    • (1995) Rev. Sci. Instrum. , vol.66 , Issue.12 , pp. 5486-5492
    • Snigirev, A.1    Snigireva, I.2    Kohn, V.3    Kuznetsov, S.4    Schelokov, I.5
  • 45
    • 80052071420 scopus 로고    scopus 로고
    • Talbot phase-contrast x-ray imaging for the small joints of the hand
    • 10.1088/0031-9155/56/17/015 0031-9155
    • Stutman D, Beck T J, Carrino J A and Bingham C O 2011 Talbot phase-contrast x-ray imaging for the small joints of the hand Phys. Med. Biol. 56 5697-720
    • (2011) Phys. Med. Biol. , vol.56 , Issue.17 , pp. 5697-5720
    • Stutman, D.1    Beck, T.J.2    Carrino, J.A.3    Bingham, C.O.4
  • 46
    • 0000741812 scopus 로고
    • Facts relating to optical science: IV
    • 0031-8086
    • Talbot H F 1836 Facts relating to optical science: IV Philos. Mag. 9 401-7
    • (1836) Philos. Mag. , vol.9 , pp. 401-407
    • Talbot, H.F.1
  • 47
    • 0029955942 scopus 로고    scopus 로고
    • Phase-contrast imaging using polychromatic hard X-rays
    • DOI 10.1038/384335a0
    • Wilkins S W, Gureyev T E, Gao D, Pogany A and Stevenson A W 1996 Phase-contrast imaging using polychromatic hard x-rays Nature 384 335-8 (Pubitemid 26408509)
    • (1996) Nature , vol.384 , Issue.6607 , pp. 335-338
    • Wilkins, S.W.1    Gureyev, T.E.2    Gao, D.3    Pogany, A.4    Stevenson, A.W.5
  • 48
    • 60249101167 scopus 로고    scopus 로고
    • Quantitative assessment of articular cartilage morphology via EPIC-microCT
    • 10.1016/j.joca.2008.07.015 1063-4584
    • Xie L, Lin A S P, Levenston M E and Guldberg R E 2009 Quantitative assessment of articular cartilage morphology via EPIC-microCT Osteoarthritis Cartilage 17 313-20
    • (2009) Osteoarthritis Cartilage , vol.17 , Issue.3 , pp. 313-320
    • Xie, L.1    Lin, A.S.P.2    Levenston, M.E.3    Guldberg, R.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.