메뉴 건너뛰기




Volumn 7622, Issue PART 3, 2010, Pages

Bone cartilage imaging with X-ray interferometry using a practical X-ray tube

Author keywords

Bone cartilage; Grating interferometry; Medical imaging; Phase contrast imaging; Small angle scattering image; Talbot Lau interferometry

Indexed keywords

ALUMINUM FILTERS; CALIFORNIA , USA; CARTILAGE IMAGING; CLINICAL USE; FAIRCHILD IMAGING; FOCAL SPOT SIZE; GRATING INTERFEROMETRY; HUMAN BODIES; IMAGING PERFORMANCE; MEAN ENERGY; PHASE-CONTRAST IMAGING; PIXEL SIZE; RHEUMATOID ARTHRITIS; SMALL-ANGLE SCATTERING; SOFT TISSUE; TALBOT-LAU INTERFEROMETER; TALBOT-LAU INTERFEROMETRY; TOKYO , JAPAN; TOSHIBA; TUBE VOLTAGES; WAVE-OPTICS; X-RAY DETECTOR; X-RAY DOSE; X-RAY GRATINGS; X-RAY IMAGE; X-RAY INTERFEROMETRY;

EID: 79958859227     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.843655     Document Type: Conference Paper
Times cited : (5)

References (19)
  • 1
    • 77954583260 scopus 로고    scopus 로고
    • published in Japanese
    • Momose A., Kogaku, 29(5),287-294(2000) published in Japanese
    • (2000) Kogaku , vol.29 , Issue.5 , pp. 287-294
    • Momose, A.1
  • 2
    • 0002520458 scopus 로고    scopus 로고
    • Phase-sensitive x-ray imaging
    • Fitzgerald R., "Phase-sensitive x-ray imaging," Phys. Today 53, 23-26(2000).
    • (2000) Phys. Today , vol.53 , pp. 23-26
    • Fitzgerald, R.1
  • 5
    • 77954654122 scopus 로고    scopus 로고
    • Fundamental technical concept of digital phase contrast mammography
    • Honda C, "Fundamental Technical Concept of Digital Phase Contrast Mammography," Medical Imaging and Information Science 21 (3),230-238(2004)
    • (2004) Medical Imaging and Information Science , vol.21 , Issue.3 , pp. 230-238
    • Honda, C.1
  • 6
    • 33845232234 scopus 로고    scopus 로고
    • X-ray phase contrast imaging using a grating interferometer
    • Pfciffer F., Weitkamp T. and David C, "X-ray phase contrast imaging using a grating interferometer," Europhysics News 37(5), 13-15(2006)
    • (2006) Europhysics News , vol.37 , Issue.5 , pp. 13-15
    • Pfciffer, F.1    Weitkamp, T.2    David, C.3
  • 7
    • 0000741812 scopus 로고
    • Facts relating to optical science
    • Talbot H. F., "Facts relating to optical science," Philos. Mag. 9, 401-407(1836)
    • (1836) Philos. Mag. , vol.9 , pp. 401-407
    • Talbot, H.F.1
  • 11
    • 84970884391 scopus 로고
    • Beugungsersheinungen an doppclrastern
    • Lau E., "Beugungsersheinungen an Doppclrastern," Ann. Physik(Leipzig), 6(2), 417-423(1948)
    • (1948) Ann. Physik(Leipzig) , vol.6 , Issue.2 , pp. 417-423
    • Lau, E.1
  • 12
    • 0000806290 scopus 로고
    • Talbot-vonLau atom intcrferometry with cold slow potassium
    • Clauser J. F. and Li S., "Talbot-vonLau atom intcrferometry with cold slow potassium," Phys. Rev. A 49(4), R2213-R2216(1994)
    • (1994) Phys. Rev. A , vol.49 , Issue.4
    • Clauser, J.F.1    Li, S.2
  • 13
    • 84873930667 scopus 로고    scopus 로고
    • US Patent 5,812,629
    • Clauser J. F., US Patent 5,812,629
    • Clauser, J.F.1
  • 16
    • 55049087592 scopus 로고    scopus 로고
    • Efficiency of capturing a phase image using cone-beam x-ray Talbot intcrerometry
    • Yashiro W., Takcda Y., and Momose A., "Efficiency of capturing a phase image using cone-beam x-ray Talbot intcrerometry," J. Opt. Soc. Am. A 25(8), 2025-2039(2008)
    • (2008) J. Opt. Soc. Am. A , vol.25 , Issue.8 , pp. 2025-2039
    • Yashiro, W.1    Takcda, Y.2    Momose, A.3
  • 17
    • 34547902908 scopus 로고    scopus 로고
    • Fabrication of diffraction grating with high aspect ratio using x-ray lithography technique for x-ray phase imaging
    • Noda D., Tanaka M., Shimada K. and Hattori T., "Fabrication of Diffraction Grating with High Aspect Ratio Using X-ray Lithography Technique for X-ray Phase Imaging," Jpn. J. Appl. Phys. 46(2), 849-851(2007)
    • (2007) Jpn. J. Appl. Phys. , vol.46 , Issue.2 , pp. 849-851
    • Noda, D.1    Tanaka, M.2    Shimada, K.3    Hattori, T.4
  • 19
    • 67649804863 scopus 로고    scopus 로고
    • Diffraction-enhanced imaging of musculoskeletal tissues using a conventional x-ray tube
    • Muehleman C, Li J., Connor D., Parham C, Pisano E., and Zhong Z., "Diffraction-Enhanced Imaging of Musculoskeletal Tissues Using a Conventional X-ray Tube," Acad. Radiol, 16(8), 918-923(2009)
    • (2009) Acad. Radiol , vol.16 , Issue.8 , pp. 918-923
    • Muehleman, C.1    Li, J.2    Connor, D.3    Parham, C.4    Pisano, E.5    Zhong, Z.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.