메뉴 건너뛰기




Volumn 54, Issue 15, 2009, Pages

Deconvolution of x-ray phase contrast images as a way to retrieve phase information lost due to insufficient resolution

Author keywords

[No Author keywords available]

Indexed keywords

COMBINED EFFECT; DETECTOR RESOLUTION; FILTER PARAMETER; FOURIER SPACE; FREE SPACE PROPAGATION; IMAGE NOISE; PHASE CONTRASTS; PHASE INFORMATION; PHASE SIGNALS; SECONDARY PHASE; SOURCE SIZES; SYNCHROTRON RADIATION FACILITY; X-RAY PHASE CONTRAST IMAGES; X-RAY PHASE-CONTRAST IMAGING;

EID: 70349773421     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/15/N02     Document Type: Article
Times cited : (18)

References (16)
  • 1
    • 15144338828 scopus 로고    scopus 로고
    • Low-dose phase contrast x-ray medical imaging
    • Arfelli F et al 1998 Low-dose phase contrast x-ray medical imaging Phys. Med. Biol. 43 2845-52
    • (1998) Phys. Med. Biol. , vol.43 , Issue.10 , pp. 2845-2852
    • Arfelli, F.1
  • 2
    • 58149115072 scopus 로고    scopus 로고
    • Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl
    • Arvanitis C D, Bohndiek S E, Blakesey J, Olivo A and Speller R D 2009 Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl Med. Phys. 36 116-26
    • (2009) Med. Phys. , vol.36 , Issue.1 , pp. 116-126
    • Arvanitis, C.D.1    Bohndiek, S.E.2    Blakesey, J.3    Olivo, A.4    Speller, R.D.5
  • 6
    • 4444377523 scopus 로고    scopus 로고
    • Medical phase contrast x-ray imaging: Current status and future prospects
    • Lewis R A 2004 Medical phase contrast x-ray imaging: current status and future prospects Phys. Med. Biol. 49 3573-83
    • (2004) Phys. Med. Biol. , vol.49 , Issue.16 , pp. 3573-3583
    • Lewis, R.A.1
  • 7
    • 0029954434 scopus 로고    scopus 로고
    • Phase-contrast x-ray computed tomography for observing biological soft tissues
    • Momose A, Takeda T, Itai Y and Hirano K 1996 Phase-contrast x-ray computed tomography for observing biological soft tissues Nature Med. 2 473-5
    • (1996) Nature Med. , vol.2 , Issue.4 , pp. 473-475
    • Momose, A.1    Takeda, T.2    Itai, Y.3    Hirano, K.4
  • 10
    • 33745085977 scopus 로고    scopus 로고
    • Experimental validation of a simple model capable of predicting the phase contrast imaging capabilities of any x-ray imaging system
    • Olivo A and Speller R 2006 Experimental validation of a simple model capable of predicting the phase contrast imaging capabilities of any x-ray imaging system Phys. Med. Biol. 51 3015-30
    • (2006) Phys. Med. Biol. , vol.51 , Issue.12 , pp. 3015-3030
    • Olivo, A.1    Speller, R.2
  • 11
    • 34548046244 scopus 로고    scopus 로고
    • A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources
    • Olivo A and Speller R 2007 A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources Appl. Phys. Lett. 91 074106
    • (2007) Appl. Phys. Lett. , vol.91 , Issue.7 , pp. 074106
    • Olivo, A.1    Speller, R.2
  • 12
    • 0033710972 scopus 로고    scopus 로고
    • Experimental evaluation of a simple algorithm to enhance the spatial resolution in scanned radiographic systems
    • Olivo A et al 2000 Experimental evaluation of a simple algorithm to enhance the spatial resolution in scanned radiographic systems Med. Phys. 27 2609-16
    • (2000) Med. Phys. , vol.27 , Issue.11 , pp. 2609-2616
    • Olivo, A.1
  • 13
    • 33645795432 scopus 로고    scopus 로고
    • Phase retrieval and differential phase-contrast imaging with low-brilliance x-ray sources
    • Pfeiffer F, Weitkamp T, Bunk O and David C 2006 Phase retrieval and differential phase-contrast imaging with low-brilliance x-ray sources Nat. Phys. 2 258-61
    • (2006) Nat. Phys. , vol.2 , Issue.4 , pp. 258-261
    • Pfeiffer, F.1    Weitkamp, T.2    Bunk, O.3    David, C.4
  • 15
    • 0029532089 scopus 로고
    • On the possibilities of x-ray phase-contrast microimaging by coherent high-energy synchrotron radiation
    • Snigirev A, Snigireva I, Kohn V, Kuznetsov S and Schelokov I 1995 On the possibilities of x-ray phase-contrast microimaging by coherent high-energy synchrotron radiation Rev. Sci. Instrum. 66 5486-92
    • (1995) Rev. Sci. Instrum. , vol.66 , Issue.12 , pp. 5486-5492
    • Snigirev, A.1    Snigireva, I.2    Kohn, V.3    Kuznetsov, S.4    Schelokov, I.5
  • 16
    • 4644293266 scopus 로고    scopus 로고
    • X-ray imaging performance of structured cesium iodide scintillators
    • Zhao W, Ristic G and Rowlands J A 2004 X-ray imaging performance of structured cesium iodide scintillators Med. Phys. 31 2595-605
    • (2004) Med. Phys. , vol.31 , Issue.9 , pp. 2594-2605
    • Zhao, W.1    Ristic, G.2    Rowlands, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.