메뉴 건너뛰기




Volumn 23, Issue 12, 2012, Pages

Improving electrochemical performance of flexible thin film electrodes with micropillar array structures

Author keywords

bioelectricity; electrical impedance spectroscopy; electrode; micropatterning; PDMS

Indexed keywords

BIOELECTRIC PHENOMENA; CHLORINE COMPOUNDS; COATINGS; COPPER; ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRODES; ELECTROLYTES; ELECTROPHYSIOLOGY; EQUIVALENT CIRCUITS; MICROCHANNELS; POLYDIMETHYLSILOXANE; PULSE WIDTH MODULATION; REDUCTION; SILICONES; SILVER; SPECTROSCOPY; SUBSTRATES; THIN FILMS;

EID: 84870316427     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/23/12/125701     Document Type: Article
Times cited : (26)

References (62)
  • 5
    • 33745713031 scopus 로고    scopus 로고
    • Depth of anaesthesia monitoring: What's available, what's validated and what's next?
    • 10.1093/bja/ael120 0007-0912
    • Bruhn J, Myles P S, Sneyd R and Struys M M R F 2006 Depth of anaesthesia monitoring: What's available, what's validated and what's next? Br. J. Anaesth. 97 85-94
    • (2006) Br. J. Anaesth. , vol.97 , Issue.1 , pp. 85-94
    • Bruhn, J.1    Myles, P.S.2    Sneyd, R.3    Struys, M.M.R.F.4
  • 6
    • 0001574753 scopus 로고    scopus 로고
    • Micromachined, polyimide-based devices for flexible neural interfaces
    • 10.1023/A:1009955222114 1387-2176
    • Stieglitz T, Beutel H, Schuettler M and Meyer J 2000 Micromachined, polyimide-based devices for flexible neural interfaces Biomed. Microdevice. 2 283-94
    • (2000) Biomed. Microdevice. , vol.2 , Issue.4 , pp. 283-294
    • Stieglitz, T.1    Beutel, H.2    Schuettler, M.3    Meyer, J.4
  • 10
    • 78649585402 scopus 로고    scopus 로고
    • Polymers for neural implants
    • 10.1002/polb.22169 0887-6266 B
    • Hassler C, Boretius T and Stieglitz T 2011 Polymers for neural implants J. Polym. Sci. B 49 18-33
    • (2011) J. Polym. Sci. , vol.49 , Issue.1 , pp. 18-33
    • Hassler, C.1    Boretius, T.2    Stieglitz, T.3
  • 12
    • 33745108264 scopus 로고    scopus 로고
    • Biomedical microdevices for neural implants
    • 10.1007/978-0-387-28732-4-4
    • Stieglitz T and Meyer J-U 2006 Biomedical microdevices for neural implants BioMEMS ed G A Urban (Dordrecht: Springer) pp 71-137
    • (2006) BioMEMS , vol.16 , pp. 71-137
    • Stieglitz, T.1    Meyer, J.-U.2
  • 13
    • 0035984039 scopus 로고    scopus 로고
    • Poly(dimethylsiloxane) as a material for fabricating microfluidic devices
    • 10.1021/ar010110q 0001-4842
    • McDonald J C and Whitesides G M 2002 Poly(dimethylsiloxane) as a material for fabricating microfluidic devices Acc. Chem. Res. 35 491-9
    • (2002) Acc. Chem. Res. , vol.35 , Issue.7 , pp. 491-499
    • McDonald, J.C.1    Whitesides, G.M.2
  • 14
    • 33645238778 scopus 로고    scopus 로고
    • Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems
    • 10.1007/s10544-005-6070-2 1387-2176
    • Mata A, Fleischman A and Roy S 2005 Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems Biomed. Microdev. 7 281-93
    • (2005) Biomed. Microdev. , vol.7 , Issue.4 , pp. 281-293
    • Mata, A.1    Fleischman, A.2    Roy, S.3
  • 16
    • 0033083552 scopus 로고    scopus 로고
    • Molding of deep polydimethylsiloxane microstructures for microfluidics and biological applications
    • Folch A, Ayon A, Hurtado O, Schmidt M A and Toner M 1999 Molding of deep polydimethylsiloxane microstructures for microfluidics and biological applications J. Biomech. Eng. 121 28-34 (Pubitemid 29102070)
    • (1999) Journal of Biomechanical Engineering , vol.121 , Issue.1 , pp. 28-34
    • Folch, A.1    Ayon, A.2    Hurtado, O.3    Schmidt, M.A.4    Toner, M.5
  • 17
    • 0035109061 scopus 로고    scopus 로고
    • Scalp electrode impedance, infection risk, and EEG data quality
    • DOI 10.1016/S1388-2457(00)00533-2, PII S1388245700005332
    • Ferree T C, Luu P, Russell G S and Tucker D M 2001 Scalp electrode impedance, infection risk, and EEG data quality Clin. Neurophys. 112 536-44 (Pubitemid 32166936)
    • (2001) Clinical Neurophysiology , vol.112 , Issue.3 , pp. 536-544
    • Ferree, T.C.1    Luu, P.2    Russell, G.S.3    Tucker, D.M.4
  • 18
    • 77955163795 scopus 로고    scopus 로고
    • The effects of electrode impedance on data quality and statistical significance in ERP recordings
    • Kappenman E S and Luck S J 2010 The effects of electrode impedance on data quality and statistical significance in ERP recordings Psychophysiology 47 888-904
    • (2010) Psychophysiology , vol.47 , pp. 888-904
    • Kappenman, E.S.1    Luck, S.J.2
  • 25
    • 30244483471 scopus 로고    scopus 로고
    • An active, microfabricated, scalp electrode array for EEG recording
    • PII S0924424796012642
    • Alizadeh-Taheri B, Smith R L and Knight R T 1996 An active, microfabricated, scalp electrode array for EEG recording Sensors Actuators A 54 606-11 (Pubitemid 126357020)
    • (1996) Sensors and Actuators, A: Physical , vol.54 , Issue.1-3 , pp. 606-611
    • Alizadeh-Taheri, B.1    Smith, R.L.2    Knight, R.T.3
  • 27
    • 70350303223 scopus 로고    scopus 로고
    • Nanomaterials for neural interfaces
    • 10.1002/adma.200801984 0935-9648
    • Kotov N A et al 2009 Nanomaterials for neural interfaces Adv. Mater. 21 3970-4004
    • (2009) Adv. Mater. , vol.21 , Issue.40 , pp. 3970-4004
    • Kotov, N.A.1
  • 28
    • 0346634884 scopus 로고    scopus 로고
    • Electrochemical platinum coatings for improving performance of implantable microelectrode arrays
    • DOI 10.1016/S0142-9612(02)00195-3, PII S0142961202001953
    • de Haro C, Mas R, Abadal G, Muñoz J, Perez-Murano F and Domínguez C 2002 Electrochemical platinum coatings for improving performance of implantable microelectrode arrays Biomaterials 23 4515-21 (Pubitemid 36151603)
    • (2002) Biomaterials , vol.23 , Issue.23 , pp. 4515-4521
    • De Haro, C.1    Mas, R.2    Abadal, G.3    Munoz, J.4    Perez-Murano, F.5    Dominguez, C.6
  • 29
    • 84912972877 scopus 로고    scopus 로고
    • Cheung K C 1998 Microscale and nanoscale neural interfaces Doctoral dissertation University of California, Berkeley, CA
    • (1998) Doctoral Dissertation
    • Cheung, K.C.1
  • 31
    • 0024385120 scopus 로고
    • Sealing cultured invertebrate neurons to embedded dish electrodes facilitates long-term stimulation and recording
    • DOI 10.1016/0165-0270(89)90055-1
    • Regehr W G, Pine J, Cohan C S, Mischke M D and Tank D W 1989 Sealing cultured invertebrate neurons to embedded dish electrodes facilitates long-term stimulation and recording J. Neurosci. Methods 30 91-106 (Pubitemid 19255662)
    • (1989) Journal of Neuroscience Methods , vol.30 , Issue.2 , pp. 91-106
    • Regehr, W.G.1    Pine, J.2    Cohan, C.S.3    Mischke, M.D.4    Tank, D.W.5
  • 32
    • 0037086859 scopus 로고    scopus 로고
    • A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices
    • DOI 10.1016/S0165-0270(01)00514-3, PII S0165027001005143
    • Heuschkel M O, Fejtl M, Raggenbass M, Bertrand D and Renaud P 2002 A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices J. Neurosci. Methods 114 135-48 (Pubitemid 34150117)
    • (2002) Journal of Neuroscience Methods , vol.114 , Issue.2 , pp. 135-148
    • Heuschkel, M.O.1    Fejtl, M.2    Raggenbass, M.3    Bertrand, D.4    Renaud, P.5
  • 34
    • 50249084472 scopus 로고    scopus 로고
    • Neural stimulation and recording electrodes
    • 10.1146/annurev.bioeng.10.061807.160518 1523-9829
    • Cogan S F 2008 Neural stimulation and recording electrodes Annu. Rev. Biomed. Eng. 10 275-309
    • (2008) Annu. Rev. Biomed. Eng. , vol.10 , Issue.1 , pp. 275-309
    • Cogan, S.F.1
  • 35
    • 0018899387 scopus 로고
    • Recording action potentials from cultured neurons with extracellular microcircuit electrodes
    • DOI 10.1016/0165-0270(80)90042-4
    • Pine J 1980 Recording action potentials from cultured neurons with extracellular microcircuit electrodes J. Neurosci. Methods 2 19-31 (Pubitemid 10178093)
    • (1980) Journal of Neuroscience Methods , vol.2 , Issue.1 , pp. 19-31
    • Pine, J.1
  • 36
    • 34547270597 scopus 로고    scopus 로고
    • Superhydrophobic polyolefin surfaces: Controlled micro- and nanostructures
    • DOI 10.1021/la063588h
    • Puukilainen E, Rasilainen T, Suvanto M and Pakkanen T A 2007 Superhydrophobic polyolefin surfaces: controlled micro- and nanostructures Langmuir 23 7263-8 (Pubitemid 47143255)
    • (2007) Langmuir , vol.23 , Issue.13 , pp. 7263-7268
    • Puukilainen, E.1    Rasilainen, T.2    Suvanto, M.3    Pakkanen, T.A.4
  • 37
    • 33847661974 scopus 로고    scopus 로고
    • Modification of cycloolefin copolymer and poly(vinyl chloride) surfaces by superimposition of nano- and microstructures
    • DOI 10.1016/j.apsusc.2006.11.039, PII S016943320601511X
    • Koponen H, Saarikoski I, Korhonen T, Pääkkö M, Kuisma R, Pakkanen T T, Suvanto M and Pakkanen T A 2007 Modification of cycloolefin copolymer and poly(vinyl chloride) surfaces by superimposition of nano- and microstructures Appl. Surf. Sci. 253 5208-13 (Pubitemid 46366025)
    • (2007) Applied Surface Science , vol.253 , Issue.12 , pp. 5208-5213
    • Koponen, H.-K.1    Saarikoski, I.2    Korhonen, T.3    Paakko, M.4    Kuisma, R.5    Pakkanen, T.T.6    Suvanto, M.7    Pakkanen, T.A.8
  • 39
    • 84963909435 scopus 로고
    • Uber das verhalten sogenannter unpolarisierbarer electroden gegen wechselstrom
    • 10.1002/andp.18993030302 0003-3804
    • Warburg E 1899 Uber das verhalten sogenannter unpolarisierbarer electroden gegen wechselstrom Ann. Phys. Chem. 67 493-9
    • (1899) Ann. Phys. Chem. , vol.303 , Issue.3 , pp. 493-499
    • Warburg, E.1
  • 40
    • 0030614375 scopus 로고    scopus 로고
    • Historical evolution of circuit models for the electrode-electrolyte interface
    • Geddes L 1997 Historical evolution of circuit models for the electrode-electrolyte interface Ann. Biomed. Eng. 25 1-14 (Pubitemid 127623124)
    • (1997) Annals of Biomedical Engineering , vol.25 , Issue.1 , pp. 1-14
    • Geddes, L.A.1
  • 41
    • 44949232043 scopus 로고    scopus 로고
    • Analyzing the electroactive surface of gold nanopillars by electrochemical methods for electrode miniaturization
    • 10.1016/j.electacta.2008.03.068 0013-4686
    • Schröper F, Brüggemann D, Mourzina Y, Wolfrum B, Offenhäusser A and Mayer D 2008 Analyzing the electroactive surface of gold nanopillars by electrochemical methods for electrode miniaturization Electrochim. Acta 53 6265-72
    • (2008) Electrochim. Acta , vol.53 , Issue.21 , pp. 6265-6272
    • Schröper, F.1    Brüggemann, D.2    Mourzina, Y.3    Wolfrum, B.4    Offenhäusser, A.5    Mayer, D.6
  • 42
    • 32044462723 scopus 로고    scopus 로고
    • Vertically aligned carbon nanoflber arrays: An advance toward electrical-neural interfaces
    • DOI 10.1002/smll.200500175
    • Nguyen-Vu T D B, Chen H, Cassell A M, Andrews R, Meyyappan M and Li J 2006 Vertically aligned carbon nanofiber arrays: an advance toward electrical-neural interfaces Small 2 89-94 (Pubitemid 43198000)
    • (2006) Small , vol.2 , Issue.1 , pp. 89-94
    • Nguyen-Vu, T.D.B.1    Chen, H.2    Cassell, A.M.3    Andrews, R.4    Meyyappan, M.5    Li, J.6
  • 43
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacement - A materials science perspective
    • DOI 10.1016/S0142-9612(97)00146-4, PII S0142961297001464
    • Long M and Rack H J 1998 Titanium alloys in total joint replacement - a materials science perspective Biomaterials 19 1621-39 (Pubitemid 28512843)
    • (1998) Biomaterials , vol.19 , Issue.18 , pp. 1621-1639
    • Long, M.1    Rack, H.J.2
  • 45
    • 0035443932 scopus 로고    scopus 로고
    • 0 into a capacitance
    • Hsu C H and Mansfeld F 2001 Concerning the conversion of the constant phase element parameter Y0 into a capacitance Corrosion 57 747-8 (Pubitemid 32972801)
    • (2001) Corrosion , vol.57 , Issue.9 , pp. 747-748
    • Hsu, C.H.1    Mansfeld, F.2
  • 47
    • 70349774756 scopus 로고    scopus 로고
    • Impedance characteristics of deep brain stimulation electrodes in vitro and in vivo
    • 1741-2552 046008
    • Wei X F and Grill W M 2009 Impedance characteristics of deep brain stimulation electrodes in vitro and in vivo J. Neural Eng. 6 046008
    • (2009) J. Neural Eng. , vol.6 , Issue.4
    • Wei, X.F.1    Grill, W.M.2
  • 48
    • 84865977955 scopus 로고    scopus 로고
    • Signal distortion from microelectrodes in clinical EEG acquisition systems
    • 1741-2552 056007
    • Stacey W C, Kellis S, Patel P R, Greger B and Butson C R 2012 Signal distortion from microelectrodes in clinical EEG acquisition systems J. Neural Eng. 9 056007
    • (2012) J. Neural Eng. , vol.9 , Issue.5
    • Stacey, W.C.1    Kellis, S.2    Patel, P.R.3    Greger, B.4    Butson, C.R.5
  • 50
    • 0026487947 scopus 로고
    • Optimal electrolytic chloriding of silver ink electrodes for use in electrical impedance tomography
    • 10.1088/0143-0815/13/A/004 0143-0815
    • McAdams E T, Henry P, Anderson J M and Jossinet J 1992 Optimal electrolytic chloriding of silver ink electrodes for use in electrical impedance tomography Clin. Phys. Physiol. Meas. 13 19-23
    • (1992) Clin. Phys. Physiol. Meas. , vol.13 , Issue.A , pp. 19-23
    • McAdams, E.T.1    Henry, P.2    Anderson, J.M.3    Jossinet, J.4
  • 51
    • 0014457408 scopus 로고
    • Optimum electrolytic chloriding of silver electrodes
    • 10.1007/BF02474669 0025-696X
    • Geddes L, Baker L and Moore A 1969 Optimum electrolytic chloriding of silver electrodes Med. Biol. Eng. Comp. 7 49-56
    • (1969) Med. Biol. Eng. Comp. , vol.7 , Issue.1 , pp. 49-56
    • Geddes, L.1    Baker, L.2    Moore, A.3
  • 53
    • 42449145601 scopus 로고    scopus 로고
    • Stretchable gold tracks on flat polydimethylsiloxane (PDMS) rubber substrate
    • DOI 10.1080/00218460801954292, PII 792144836
    • Befahy S, Yunus S, Burguet V, Heine J, Troosters M and Bertrand P 2008 Stretchable gold tracks on flat polydimethylsiloxane (PDMS) rubber substrate J. Adhes. 84 231-9 (Pubitemid 351566489)
    • (2008) Journal of Adhesion , vol.84 , Issue.3 , pp. 231-239
    • Befahy, S.1    Yunus, S.2    Burguet, V.3    Heine, J.-S.4    Troosters, M.5    Bertrand, P.6
  • 55
    • 75049085413 scopus 로고    scopus 로고
    • Adhesion, spreading and osteogenic differentiation of mesenchymal stem cells cultured on micropatterned amorphous diamond, titanium, tantalum and chromium coatings on silicon
    • 10.1007/s10856-009-3836-8 0957-4530
    • Myllymaa S, Kaivosoja E, Myllymaa K, Sillat T, Korhonen H, Lappalainen R and Konttinen Y T 2010 Adhesion, spreading and osteogenic differentiation of mesenchymal stem cells cultured on micropatterned amorphous diamond, titanium, tantalum and chromium coatings on silicon J. Mater. Sci. Mater. Med. 21 329-41
    • (2010) J. Mater. Sci. Mater. Med. , vol.21 , Issue.1 , pp. 329-341
    • Myllymaa, S.1    Kaivosoja, E.2    Myllymaa, K.3    Sillat, T.4    Korhonen, H.5    Lappalainen, R.6    Konttinen, Y.T.7
  • 58
    • 63749111006 scopus 로고    scopus 로고
    • Micro- and nanobiosensors - State of the art and trends
    • 0957-0233 012001
    • Urban G A 2009 Micro- and nanobiosensors - state of the art and trends Meas. Sci. Technol. 20 012001
    • (2009) Meas. Sci. Technol. , vol.20 , Issue.1
    • Urban, G.A.1
  • 59
    • 34247169614 scopus 로고    scopus 로고
    • Medical implants based on microsystems
    • 0957-0233 R01
    • Mokwa W 2007 Medical implants based on microsystems Meas. Sci. Technol. 18 R47-R57
    • (2007) Meas. Sci. Technol. , vol.18 , Issue.5
    • Mokwa, W.1
  • 60
    • 0042767704 scopus 로고    scopus 로고
    • Criteria for the selection of materials for implanted electrodes
    • 10.1114/1.1581292 0090-6964
    • Geddes L A and Roeder R 2003 Criteria for the selection of materials for implanted electrodes Ann. Biomed. Eng. 31 879-90
    • (2003) Ann. Biomed. Eng. , vol.31 , Issue.7 , pp. 879-890
    • Geddes, L.A.1    Roeder, R.2
  • 62
    • 77950998033 scopus 로고    scopus 로고
    • Effects of adsorbed proteins, an antifouling agent and long-duration DC voltage pulses on the impedance of silicon-based neural microelectrodes
    • Sommakia S, Rickus J L and Otto K J 2009 Effects of adsorbed proteins, an antifouling agent and long-duration DC voltage pulses on the impedance of silicon-based neural microelectrodes Conf. Proc. IEEE Eng. Med. Biol. Soc. pp 7139-42
    • (2009) Conf. Proc. IEEE Eng. Med. Biol. Soc. , pp. 7139-7142
    • Sommakia, S.1    Rickus, J.L.2    Otto, K.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.