-
2
-
-
0027998049
-
Cranio-orbital reconstruction: Safety and image quality of metallic implants on CT and MRI scanning
-
Sullivan PK, Smith JF, Rozzelle AA. Cranio-orbital reconstruction: safety and image quality of metallic implants on CT and MRI scanning. Plast Reconstr Surg. 1994 Oct;94(5):589-96. (Pubitemid 24314057)
-
(1994)
Plastic and Reconstructive Surgery
, vol.94
, Issue.5
, pp. 589-596
-
-
Sullivan, P.K.1
Smith, J.F.2
Rozzelle, A.A.3
-
3
-
-
0030635046
-
Bioresorbable implants: Applications in orthopaedic surgery
-
Blasier RD, Bucholz R, Cole W, Johnson LL, Mäkelä EA. Bioresorbable implants: applications in orthopaedic surgery. Instr Course Lect. 1997;46:531-46.
-
(1997)
Instr Course Lect
, vol.46
, pp. 531-546
-
-
Blasier, R.D.1
Bucholz, R.2
Cole, W.3
Johnson, L.L.4
Mäkelä, E.A.5
-
4
-
-
0021842535
-
Biodegradable implants in fracture fixation: early results of treatment of fractures of the ankle
-
Rokkanen P, Böstman O, Vainionpää S, Vihtonen K, Törmälä P, Laiho J, Kilpikari J, Tamminmäki M. Biodegradable implants in fracture fixation: early results of treatment of fractures of the ankle. Lancet. 1985 Jun 22;1(8443):1422-4. (Pubitemid 15057975)
-
(1985)
Lancet
, vol.1
, Issue.8443
, pp. 1422-1424
-
-
Rokkanen, P.1
Vainionpaa, S.2
Tormala, P.3
-
5
-
-
0032444193
-
Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw
-
Böstman OM, Pihlajamäki HK. Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw. A case report. J Bone Joint Surg Am. 1998 Dec;80(12):1791-4. (Pubitemid 29013813)
-
(1998)
Journal of Bone and Joint Surgery - Series A
, vol.80
, Issue.12
, pp. 1791-1794
-
-
Bostman, O.M.1
Pihlajamaki, H.K.2
-
6
-
-
0023198604
-
Biodegradable internal fixation for malleolar fractures. A prospective randomised trial
-
Aug
-
Böstman O, Vainionpää S, Hirvensalo E, Mäkelä A, Vihtonen K, Törmälä P, Rokkanen P. Biodegradable internal fixation for malleolar fractures. A prospective randomised trial. J Bone Joint Surg Br. 1987 Aug;69(4):615-9.
-
(1987)
J Bone Joint Surg Br
, vol.69
, Issue.4
, pp. 615-619
-
-
Böstman, O.1
Vainionpää, S.2
Hirvensalo, E.3
Mäkelä, A.4
Vihtonen, K.5
Törmälä, P.6
Rokkanen, P.7
-
7
-
-
0025276788
-
Local complications following implantation of Biorod
-
Jun; German
-
Poigenfürst J, Leixnering M, Ben Mokhtar M. [Local complications following implantation of Biorod]. Aktuelle Traumatol. 1990 Jun;20(3):157-9. German.
-
(1990)
Aktuelle Traumatol
, vol.20
, Issue.3
, pp. 157-159
-
-
Poigenfürst, J.1
Leixnering, M.2
Ben Mokhtar, M.3
-
8
-
-
0031943468
-
Redisplacement after ankle osteosynthesis with absorbable implants
-
DOI 10.1007/s004020050218
-
Pelto-Vasenius K, Hirvensalo E, Vasenius J, Partio EK, Böstman O, Rokkanen P. Redisplacement after ankle osteosynthesis with absorbable implants. Arch Orthop Trauma Surg. 1998;117(3):159-62. (Pubitemid 28072542)
-
(1998)
Archives of Orthopaedic and Trauma Surgery
, vol.117
, Issue.3
, pp. 159-162
-
-
Pelto-Vasenius, K.1
Hirvensalo, E.2
Vasenius, J.3
Partio, E.K.4
Bostman, O.5
Rokkanen, P.6
-
9
-
-
39149129995
-
Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee
-
Nov-Dec
-
Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA, Prokuski L, Sirkin MS, Ziran B, Henley B, Audigé L. Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma. 2007 Nov-Dec;21(10 Suppl):S1-133.
-
(2007)
J Orthop Trauma
, vol.21
, Issue.10 SUPPL.
-
-
Marsh, J.L.1
Slongo, T.F.2
Agel, J.3
Broderick, J.S.4
Creevey, W.5
DeCoster, T.A.6
Prokuski, L.7
Sirkin, M.S.8
Ziran, B.9
Henley, B.10
Audigé, L.11
-
10
-
-
0032884781
-
Short musculoskeletal function assessment questionnaire: Validity, reliability, and responsiveness
-
Swiontkowski MF, Engelberg R, Martin DP, Agel J. Short musculoskeletal function assessment questionnaire: validity, reliability, and responsiveness. J Bone Joint Surg Am. 1999 Sep;81(9):1245-60. (Pubitemid 29480278)
-
(1999)
Journal of Bone and Joint Surgery - Series A
, vol.81
, Issue.9
, pp. 1245-1260
-
-
Swiontkowski, M.F.1
Engelberg, R.2
Martin, D.P.3
Agel, J.4
-
11
-
-
0027501437
-
Predictive value of ASA classification for the assessment of the perioperative risk
-
Menke H, Klein A, John KD, Junginger T. Predictive value of ASA classification for the assessment of the perioperative risk. Int Surg. 1993 Jul-Sep;78(3):266-70. (Pubitemid 23300643)
-
(1993)
International Surgery
, vol.78
, Issue.3
, pp. 266-270
-
-
Menke, H.1
Klein, A.2
John, K.D.3
Junginger, T.4
-
12
-
-
84961057928
-
Late results of operative and non-operative treatment of severe ankle fractures. A clinical study
-
Klossner O. Late results of operative and non-operative treatment of severe ankle fractures. A clinical study. Acta Chir Scand Suppl. 1962;Suppl 293:1-93.
-
(1962)
Acta Chir Scand Suppl
, Issue.SUPPL. 293
, pp. 1-93
-
-
Klossner, O.1
-
13
-
-
0028303999
-
Clinical rating systems for the ankle-hindfoot, midfoot, hallux, and lesser toes
-
Kitaoka HB, Alexander IJ, Adelaar RS, Nunley JA, Myerson MS, Sanders M. Clinical rating systems for the ankle-hindfoot, midfoot, hallux, and lesser toes. Foot Ankle Int. 1994 Jul;15(7):349-53. (Pubitemid 24224646)
-
(1994)
Foot and Ankle International
, vol.15
, Issue.7
, pp. 349-353
-
-
Kitaoka, H.B.1
Alexander, I.J.2
Adelaar, R.S.3
Nunley, J.A.4
Myerson, M.S.5
Sanders, M.6
-
14
-
-
0023890926
-
Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis
-
Mar
-
Agins HJ, Alcock NW, Bansal M, Salvati EA, Wilson PD Jr, Pellicci PM, Bullough PG. Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis. J Bone Joint Surg Am. 1988 Mar;70(3):347-56.
-
(1988)
J Bone Joint Surg Am
, vol.70
, Issue.3
, pp. 347-356
-
-
Agins, H.J.1
Alcock, N.W.2
Bansal, M.3
Salvati, E.A.4
Wilson Jr., P.D.5
Pellicci, P.M.6
Bullough, P.G.7
-
15
-
-
10044284327
-
A degradation study of PLLA containing lauric acid
-
DOI 10.1016/j.biomaterials.2004.07.067, PII S0142961204007057
-
Renouf-Glauser AC, Rose J, Farrar D, Cameron RE. A degradation study of PLLA containing lauric acid. Biomaterials. 2005 May;26(15):2415-22. (Pubitemid 39600695)
-
(2005)
Biomaterials
, vol.26
, Issue.15
, pp. 2415-2422
-
-
Renouf-Glauser, A.C.1
Rose, J.2
Farrar, D.3
Cameron, R.E.4
-
16
-
-
33644608863
-
Comparison of the hydrolytic degradation and deformation properties of a PLLA-lauric acid based family of biomaterials
-
Feb
-
Renouf-Glauser AC, Rose J, Farrar DF, Cameron RE. Comparison of the hydrolytic degradation and deformation properties of a PLLA-lauric acid based family of biomaterials. Biomacromolecules. 2006 Feb;7(2):612-7.
-
(2006)
Biomacromolecules
, vol.7
, Issue.2
, pp. 612-617
-
-
Renouf-Glauser, A.C.1
Rose, J.2
Farrar, D.F.3
Cameron, R.E.4
-
17
-
-
0027625652
-
POLY(L-lactide): A long term degradation study in vivo I. Biological results
-
DOI 10.1016/0142-9612(93)90066-B
-
Pistner H, Gutwald R, Ordung R, Reuther J, Mühling J. Poly(L-lactide): a long-term degradation study in vivo. I. Biological results. Biomaterials. 1993 Jul;14(9):671-7. (Pubitemid 23233953)
-
(1993)
Biomaterials
, vol.14
, Issue.9
, pp. 671-677
-
-
Pistner, H.1
Gutwald, R.2
Ordung, R.3
Reuther, J.4
Muhling, J.5
-
18
-
-
0028335230
-
Poly(L-lactide): A long-term degradation study in vivo. Part II: Physico-mechanical behaviour of implants
-
May
-
Pistner H, Stallforth H, Gutwald R,Mühling J, Reuther J, Michel C. Poly(L-lactide): a long-term degradation study in vivo. Part II: Physico-mechanical behaviour of implants. Biomaterials. 1994 May;15(6):439-50.
-
(1994)
Biomaterials
, vol.15
, Issue.6
, pp. 439-450
-
-
Pistner, H.1
Stallforth, H.2
Gutwald, R.3
Mühling, J.4
Reuther, J.5
Michel, C.6
-
19
-
-
0033067026
-
SR-PLLA and SR-PGA miniscrews: Biodegradation and tissue reactions in the calvarium and dura mater
-
Peltoniemi HH, Hallikainen D, Toivonen T, Helevirta P, Waris T. SR-PLLA and SR-PGA miniscrews: biodegradation and tissue reactions in the calvarium and dura mater. J Craniomaxillofac Surg. 1999 Feb;27(1):42-50. (Pubitemid 29131405)
-
(1999)
Journal of Cranio-Maxillo-Facial Surgery
, vol.27
, Issue.1
, pp. 42-50
-
-
Peltoniemi, H.H.1
Hallikainen, D.2
Toivonen, T.3
Helevirta, P.4
Waris, T.5
-
20
-
-
2942592481
-
Bioabsorbable implants: Review of clinical experience in orthopedic surgery
-
Jan
-
Ambrose CG, Clanton TO. Bioabsorbable implants: review of clinical experience in orthopedic surgery. Ann Biomed Eng. 2004 Jan;32(1):171-7.
-
(2004)
Ann Biomed Eng
, vol.32
, Issue.1
, pp. 171-177
-
-
Ambrose, C.G.1
Clanton, T.O.2
-
22
-
-
0031952831
-
Incidence of venographically proved deep vein thrombosis after knee arthroscopy
-
DOI 10.1001/archinte.158.1.47
-
Demers C, Marcoux S, Ginsberg JS, Laroche F, Cloutier R, Poulin J. Incidence of venographically proved deep vein thrombosis after knee arthroscopy. Arch Intern Med. 1998 Jan 12;158(1):47-50. (Pubitemid 28070445)
-
(1998)
Archives of Internal Medicine
, vol.158
, Issue.1
, pp. 47-50
-
-
Demers, C.1
Marcoux, S.2
Ginsberg, J.S.3
Laroche, F.4
Cloutier, R.5
Poulin, J.6
-
23
-
-
70349907632
-
A retrospective follow-up of ankle fracture patients treated with a biodegradable plate and screws
-
Epub 2009 Apr 16
-
Kukk A, Nurmi JT. A retrospective follow-up of ankle fracture patients treated with a biodegradable plate and screws. Foot Ankle Surg. 2009;15(4):192-7. Epub 2009 Apr 16.
-
(2009)
Foot Ankle Surg
, vol.15
, Issue.4
, pp. 192-197
-
-
Kukk, A.1
Nurmi, J.T.2
-
24
-
-
25444517389
-
Fixation of syndesmotic ruptures in 38 patients with a malleolar fracture: A randomized study comparing a metallic and a bioabsorbable screw
-
Jul
-
Kaukonen JP, Lamberg T, Korkala O, Pajarinen J. Fixation of syndesmotic ruptures in 38 patients with a malleolar fracture: a randomized study comparing a metallic and a bioabsorbable screw. J Orthop Trauma. 2005 Jul; 19(6):392-5.
-
(2005)
J Orthop Trauma
, vol.19
, Issue.6
, pp. 392-395
-
-
Kaukonen, J.P.1
Lamberg, T.2
Korkala, O.3
Pajarinen, J.4
-
25
-
-
0025971712
-
Absorbable implants for the fixation of fractures
-
Jan
-
Böstman OM. Absorbable implants for the fixation of fractures. J Bone Joint Surg Am. 1991 Jan;73(1):148-53.
-
(1991)
J Bone Joint Surg Am
, vol.73
, Issue.1
, pp. 148-153
-
-
Böstman, O.M.1
-
26
-
-
0026533316
-
Mechanical characterization of biodegradable implants
-
Claes LE. Mechanical characterization of biodegradable implants. Clin Mater. 1992;10(1-2):41-6.
-
(1992)
Clin Mater
, vol.10
, Issue.1-2
, pp. 41-46
-
-
Claes, L.E.1
-
27
-
-
0025861086
-
Absorbable materials in orthopaedic surgery
-
Apr
-
Rokkanen PU. Absorbable materials in orthopaedic surgery. Ann Med. 1991 Apr;23(2):109-15.
-
(1991)
Ann Med
, vol.23
, Issue.2
, pp. 109-115
-
-
Rokkanen, P.U.1
-
28
-
-
0343353897
-
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: A review
-
Dec
-
Böstman O, Pihlajamäki H. Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review. Biomaterials. 2000 Dec;21(24): 2615-21.
-
(2000)
Biomaterials
, vol.21
, Issue.24
, pp. 2615-2621
-
-
Böstman, O.1
Pihlajamäki, H.2
|