메뉴 건너뛰기




Volumn 15, Issue 4, 2009, Pages 192-197

A retrospective follow-up of ankle fracture patients treated with a biodegradable plate and screws

Author keywords

Ankle fracture; Bioabsorbable; Biodegradable; Bioresorbable; Internal fixation

Indexed keywords

ADULT; AGED; ANKLE FRACTURE; ANKLE RADIOGRAPHY; ARTICLE; BIODEGRADABLE IMPLANT; BONE SCREW; CONTROLLED STUDY; DEEP VEIN THROMBOSIS; FEMALE; FOLLOW UP; FRACTURE FIXATION; FRACTURE HEALING; FRACTURE REDUCTION; FUNCTIONAL ASSESSMENT; HUMAN; MAJOR CLINICAL STUDY; MALE; MALLEOLUS FRACTURE; MEDICAL RECORD; PATIENT PARTICIPATION; PERIOPERATIVE COMPLICATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SOFT TISSUE DISEASE; TREATMENT OUTCOME; WOUND HEALING IMPAIRMENT;

EID: 70349907632     PISSN: 12687731     EISSN: 14609584     Source Type: Journal    
DOI: 10.1016/j.fas.2009.02.008     Document Type: Article
Times cited : (27)

References (36)
  • 2
    • 0034446599 scopus 로고    scopus 로고
    • Bioresorbable polymers in trauma and bone surgery
    • Gogolewski S. Bioresorbable polymers in trauma and bone surgery. Injury 31 suppl. 4 (2000) 28-32
    • (2000) Injury , vol.31 , Issue.SUPPL. 4 , pp. 28-32
    • Gogolewski, S.1
  • 4
    • 0028277347 scopus 로고
    • Biodegradable fixation of ankle fractures A roentgen stereophotogrammetric study of 32 cases
    • Ahl T., Dalen N., Lundberg A., and Wykman A. Biodegradable fixation of ankle fractures A roentgen stereophotogrammetric study of 32 cases. Acta Orthop Scand 65 (1994) 166-170
    • (1994) Acta Orthop Scand , vol.65 , pp. 166-170
    • Ahl, T.1    Dalen, N.2    Lundberg, A.3    Wykman, A.4
  • 5
    • 0028316813 scopus 로고
    • Fixation with bioabsorbable screws for the treatment of fractures of the ankle
    • Bucholz R.W., Henry S., and Henley M.B. Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg Am 76 (1994) 319-324
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 319-324
    • Bucholz, R.W.1    Henry, S.2    Henley, M.B.3
  • 6
    • 0026609688 scopus 로고
    • Resorbable rods and screws of polyglycolide in stabilizing malleolar fractures. A clinical study of 600 patients
    • Böstman O., Hirvensalo E., Partio E., Törmälä P., and Rokkanen P. Resorbable rods and screws of polyglycolide in stabilizing malleolar fractures. A clinical study of 600 patients. Unfallchirurg 95 (1992) 109-112
    • (1992) Unfallchirurg , vol.95 , pp. 109-112
    • Böstman, O.1    Hirvensalo, E.2    Partio, E.3    Törmälä, P.4    Rokkanen, P.5
  • 7
    • 0027510283 scopus 로고
    • Distal tibiofibular synostosis after malleolar fractures treated using absorbable implants
    • Böstman O.M. Distal tibiofibular synostosis after malleolar fractures treated using absorbable implants. Foot Ankle 14 (1993) 38-43
    • (1993) Foot Ankle , vol.14 , pp. 38-43
    • Böstman, O.M.1
  • 8
    • 0036056819 scopus 로고    scopus 로고
    • Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation
    • Hovis W.D., Kaiser B.W., Watson J.T., and Bucholz R.W. Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation. J Bone Joint Surg Am 84 (2002) 26-31
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 26-31
    • Hovis, W.D.1    Kaiser, B.W.2    Watson, J.T.3    Bucholz, R.W.4
  • 9
    • 0029860501 scopus 로고    scopus 로고
    • Biodegradable self-reinforced polyglycolide screws and rods in the fixation of displaced malleolar fractures in the elderly. A comparison with metallic implants
    • Kankare J., Partio E.K., Hirvensalo E., Böstman O., and Rokkanen P. Biodegradable self-reinforced polyglycolide screws and rods in the fixation of displaced malleolar fractures in the elderly. A comparison with metallic implants. Ann Chir Gynaecol 85 (1996) 263-270
    • (1996) Ann Chir Gynaecol , vol.85 , pp. 263-270
    • Kankare, J.1    Partio, E.K.2    Hirvensalo, E.3    Böstman, O.4    Rokkanen, P.5
  • 10
    • 0036677219 scopus 로고    scopus 로고
    • Ruptured tibio-fibular syndesmosis: comparison study of metallic to bioabsorbable fixation
    • Sinisaari I.P., Lüthje P.M., and Mikkonen R.H. Ruptured tibio-fibular syndesmosis: comparison study of metallic to bioabsorbable fixation. Foot Ankle Int 23 (2002) 744-748
    • (2002) Foot Ankle Int , vol.23 , pp. 744-748
    • Sinisaari, I.P.1    Lüthje, P.M.2    Mikkonen, R.H.3
  • 11
    • 0035031197 scopus 로고    scopus 로고
    • Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: a prospective randomized trial
    • Thordarson D.B., Samuelson M., Shepherd L.E., Merkle P.F., and Lee J. Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: a prospective randomized trial. Foot Ankle Int 22 (2001) 335-338
    • (2001) Foot Ankle Int , vol.22 , pp. 335-338
    • Thordarson, D.B.1    Samuelson, M.2    Shepherd, L.E.3    Merkle, P.F.4    Lee, J.5
  • 12
    • 5144230315 scopus 로고    scopus 로고
    • Successful use of biosorb osteofixation devices in 165 cranial and maxillofacial cases: a multicenter report
    • Ashammakhi N., Renier D., Arnaud E., Marchac D., Ninkovic M., Donaway D., et al. Successful use of biosorb osteofixation devices in 165 cranial and maxillofacial cases: a multicenter report. J Craniofac Surg 15 (2004) 692-701
    • (2004) J Craniofac Surg , vol.15 , pp. 692-701
    • Ashammakhi, N.1    Renier, D.2    Arnaud, E.3    Marchac, D.4    Ninkovic, M.5    Donaway, D.6
  • 13
    • 5144224366 scopus 로고    scopus 로고
    • A randomized controlled trial of resorbable versus titanium fixation for orthognathic surgery
    • Cheung L.K., Chow L.K., and Chiu W.K. A randomized controlled trial of resorbable versus titanium fixation for orthognathic surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 98 (2004) 386-397
    • (2004) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.98 , pp. 386-397
    • Cheung, L.K.1    Chow, L.K.2    Chiu, W.K.3
  • 14
    • 40249114842 scopus 로고    scopus 로고
    • Stability and morbidity of Le Fort I osteotomy with bioresorbable fixation: a randomized controlled trial
    • Cheung L.K., Yip I.H., and Chow R.L. Stability and morbidity of Le Fort I osteotomy with bioresorbable fixation: a randomized controlled trial. Int J Oral Maxillofac Surg 37 (2008) 232-241
    • (2008) Int J Oral Maxillofac Surg , vol.37 , pp. 232-241
    • Cheung, L.K.1    Yip, I.H.2    Chow, R.L.3
  • 15
    • 13944282152 scopus 로고    scopus 로고
    • Use of resorbable plates and screws in pediatric facial fractures
    • Eppley B.L. Use of resorbable plates and screws in pediatric facial fractures. J Oral Maxillofac Surg 63 (2005) 385-391
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 385-391
    • Eppley, B.L.1
  • 16
    • 20144379399 scopus 로고    scopus 로고
    • Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery: clinical experience in 1883 patients
    • Eppley B.L., Morales L., Wood R., Pensler J., Goldstein J., Havlik R.J., et al. Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery: clinical experience in 1883 patients. Plast Reconstr Surg 114 (2004) 850-856
    • (2004) Plast Reconstr Surg , vol.114 , pp. 850-856
    • Eppley, B.L.1    Morales, L.2    Wood, R.3    Pensler, J.4    Goldstein, J.5    Havlik, R.J.6
  • 17
  • 20
    • 0029809720 scopus 로고    scopus 로고
    • Metallic or absorbable fracture fixation devices. A cost minimization analysis.
    • Böstman O.M. Metallic or absorbable fracture fixation devices. A cost minimization analysis. Clin Orthop Relat Res 329 (1996) 233-239
    • (1996) Clin Orthop Relat Res , vol.329 , pp. 233-239
    • Böstman, O.M.1
  • 21
    • 1842407750 scopus 로고    scopus 로고
    • Comparison of costs in ankle fractures treated with absorbable or metallic fixation devices
    • Juutilainen T., Pätiälä H., Ruuskanen M., and Rokkanen P. Comparison of costs in ankle fractures treated with absorbable or metallic fixation devices. Arch Orthop Trauma Surg 116 (1997) 204-208
    • (1997) Arch Orthop Trauma Surg , vol.116 , pp. 204-208
    • Juutilainen, T.1    Pätiälä, H.2    Ruuskanen, M.3    Rokkanen, P.4
  • 22
    • 0030119189 scopus 로고    scopus 로고
    • Surgical treatment of ankle joint fractures with biodegradable screws and plates of poly-l-lactide
    • Eitenmüller J., David A., Pommer A., and Muhr G. Surgical treatment of ankle joint fractures with biodegradable screws and plates of poly-l-lactide. Chirurg 67 (1996) 413-418
    • (1996) Chirurg , vol.67 , pp. 413-418
    • Eitenmüller, J.1    David, A.2    Pommer, A.3    Muhr, G.4
  • 23
    • 30544446942 scopus 로고    scopus 로고
    • Dorsal plating of unstable distal radius fractures using a bio-absorbable plating system and bone substitute.
    • Gangopadhyay S., Ravi K., and Packer G. Dorsal plating of unstable distal radius fractures using a bio-absorbable plating system and bone substitute. J Hand Surg [Br] 31 (2006) 93-100
    • (2006) J Hand Surg [Br] , vol.31 , pp. 93-100
    • Gangopadhyay, S.1    Ravi, K.2    Packer, G.3
  • 24
    • 0346903019 scopus 로고    scopus 로고
    • Absorbable plates for rib fracture repair: preliminary experience
    • Mayberry J.C., Terhes J.T., Ellis T.J., Wanek S., and Mullins R.J. Absorbable plates for rib fracture repair: preliminary experience. J Trauma 55 (2003) 835-839
    • (2003) J Trauma , vol.55 , pp. 835-839
    • Mayberry, J.C.1    Terhes, J.T.2    Ellis, T.J.3    Wanek, S.4    Mullins, R.J.5
  • 25
    • 2442700301 scopus 로고    scopus 로고
    • Self-reinforced bioabsorbable miniplates for skeletal fixation in complex hand injury: three case reports
    • Waris E., Ninkovic M., Harpf C., Ninkovic M., and Ashammakhi N. Self-reinforced bioabsorbable miniplates for skeletal fixation in complex hand injury: three case reports. J Hand Surg [Am] 29 (2004) 452-457
    • (2004) J Hand Surg [Am] , vol.29 , pp. 452-457
    • Waris, E.1    Ninkovic, M.2    Harpf, C.3    Ninkovic, M.4    Ashammakhi, N.5
  • 26
    • 0014157567 scopus 로고
    • Supination-outward rotation injuries of the ankle. A clinical and, roentgenological study with special reference to the operative treatment.
    • Cedell C.A. Supination-outward rotation injuries of the ankle. A clinical and, roentgenological study with special reference to the operative treatment. Acta Orthop Scand Suppl (1967) 110
    • (1967) Acta Orthop Scand , Issue.SUPPL , pp. 110
    • Cedell, C.A.1
  • 27
    • 0021210120 scopus 로고
    • A scoring scale for symptom evaluation after ankle fracture
    • Olerud C., and Molander H. A scoring scale for symptom evaluation after ankle fracture. Arch Orthop Trauma Surg 103 (1984) 190-194
    • (1984) Arch Orthop Trauma Surg , vol.103 , pp. 190-194
    • Olerud, C.1    Molander, H.2
  • 28
    • 55449116779 scopus 로고    scopus 로고
    • Biomechanical in vitro evaluation of the effect of cyclic loading on the postoperative fixation stability and degradation of a biodegradable ankle plate
    • Väänänen P., Koistinen A., Nurmi J., and Lappalainen R. Biomechanical in vitro evaluation of the effect of cyclic loading on the postoperative fixation stability and degradation of a biodegradable ankle plate. J Orthop Res 26 (2008) 1485-1488
    • (2008) J Orthop Res , vol.26 , pp. 1485-1488
    • Väänänen, P.1    Koistinen, A.2    Nurmi, J.3    Lappalainen, R.4
  • 29
    • 40349100519 scopus 로고    scopus 로고
    • Degradative and mechanical properties of a novel resorbable plating system during a 3-year follow-up in vivo and in vitro
    • Nieminen T., Rantala I., Hiidenheimo I., Keränen J., Kainulainen H., Wuolijoki E., et al. Degradative and mechanical properties of a novel resorbable plating system during a 3-year follow-up in vivo and in vitro. J Mater Sci Mater Med 19 (2008) 1155-1163
    • (2008) J Mater Sci Mater Med , vol.19 , pp. 1155-1163
    • Nieminen, T.1    Rantala, I.2    Hiidenheimo, I.3    Keränen, J.4    Kainulainen, H.5    Wuolijoki, E.6
  • 30
    • 0034672866 scopus 로고    scopus 로고
    • Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices
    • An Y.H., Woolf S.K., and Friedman R.J. Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices. Biomaterials 21 (2000) 2635-2652
    • (2000) Biomaterials , vol.21 , pp. 2635-2652
    • An, Y.H.1    Woolf, S.K.2    Friedman, R.J.3
  • 32
    • 0034580276 scopus 로고    scopus 로고
    • Synthetic biodegradable polymers as orthopaedic devices
    • Middleton J.C., and Tipton A.J. Synthetic biodegradable polymers as orthopaedic devices. Biomaterials 21 (2000) 2335-2346
    • (2000) Biomaterials , vol.21 , pp. 2335-2346
    • Middleton, J.C.1    Tipton, A.J.2
  • 33
    • 0343353897 scopus 로고    scopus 로고
    • Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review
    • Böstman O., and Pihlajamäki H. Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review. Biomaterials 21 (2000) 2615-2621
    • (2000) Biomaterials , vol.21 , pp. 2615-2621
    • Böstman, O.1    Pihlajamäki, H.2
  • 34
    • 2942592481 scopus 로고    scopus 로고
    • Bioabsorbable implants: review of clinical experience in orthopedic surgery
    • Ambrose C.G., and Clanton T.O. Bioabsorbable implants: review of clinical experience in orthopedic surgery. Ann Biomed Eng 32 (2004) 171-177
    • (2004) Ann Biomed Eng , vol.32 , pp. 171-177
    • Ambrose, C.G.1    Clanton, T.O.2
  • 36
    • 0037313619 scopus 로고    scopus 로고
    • Use of a cast compared with a functional ankle brace after operative treatment of an ankle fracture. A prospective, randomized study.
    • Lehtonen H., Järvinen T.L.N., Honkonen S., Nyman M., Vihtonen K., and Järvinen M. Use of a cast compared with a functional ankle brace after operative treatment of an ankle fracture. A prospective, randomized study. J Bone Joint Surg Am 85 (2003) 205-211
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 205-211
    • Lehtonen, H.1    Järvinen, T.L.N.2    Honkonen, S.3    Nyman, M.4    Vihtonen, K.5    Järvinen, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.