메뉴 건너뛰기




Volumn 21, Issue 6, 2012, Pages 474-480

Implant primary stability determined by resonance frequency analysis: Correlation with insertion torque, histologic bone volume, and torsional stability at 6 weeks

Author keywords

bone density; implant stability; insertion torque; resonance frequency analysis

Indexed keywords

ADULT; AGED; ARTICLE; BIOPSY; BONE DENSITY; BONE REGENERATION; DENTAL ABUTMENT; FEMALE; FOLLOW UP; HUMAN; MALE; MANDIBLE; MAXILLA; MECHANICAL TORSION; METHODOLOGY; MIDDLE AGED; PATHOLOGY; PHYSIOLOGY; TOOTH IMPLANT; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TOOTH RADIOGRAPHY; TORQUE; VIBRATION;

EID: 84870216090     PISSN: 10566163     EISSN: None     Source Type: Journal    
DOI: 10.1097/ID.0b013e31826918f1     Document Type: Article
Times cited : (55)

References (38)
  • 1
    • 40549106100 scopus 로고    scopus 로고
    • Implant success, survival, and failure: The International Congress of Oral Implantolo-gists (ICOI) Pisa Consensus Conference
    • Misch CE, Perel ML, Wang HL, et al. Implant success, survival, and failure: The International Congress of Oral Implantolo-gists (ICOI) Pisa Consensus Conference. Implant Dent. 2008;17:5-15.
    • (2008) Implant Dent. , vol.17 , pp. 5-15
    • Misch, C.E.1    Perel, M.L.2    Wang, H.L.3
  • 2
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
    • Albrektsson T, Branemark PI, Hansson HA, et al. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155-170.
    • (1981) Acta Orthop Scand. , vol.52 , pp. 155-170
    • Albrektsson, T.1    Branemark, P.I.2    Hansson, H.A.3
  • 3
    • 0032102958 scopus 로고    scopus 로고
    • Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature
    • Szmukler-Moncler S, Salama H, Reingewirtz Y, et al. Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature. J Biomed Mater Res. 1998;43:192-203.
    • (1998) J Biomed Mater Res. , vol.43 , pp. 192-203
    • Szmukler-Moncler, S.1    Salama, H.2    Reingewirtz, Y.3
  • 4
    • 64549138551 scopus 로고    scopus 로고
    • Implant micromotion is related to peak insertion torque and bone density
    • Trisi P, Perfetti G, Baldoni E, et al. Implant micromotion is related to peak insertion torque and bone density. Clin Oral Implants Res. 2009;20:467-471.
    • (2009) Clin Oral Implants Res. , vol.20 , pp. 467-471
    • Trisi, P.1    Perfetti, G.2    Baldoni, E.3
  • 5
    • 4644228515 scopus 로고    scopus 로고
    • Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants
    • O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res. 2004;15:474-480.
    • (2004) Clin Oral Implants Res. , vol.15 , pp. 474-480
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 6
    • 62249165049 scopus 로고    scopus 로고
    • Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: A laboratory study
    • Tabassum A, Meijer GJ, Wolke JGC, et al. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: A laboratory study. Clin Oral Implants Res. 2009;20:327-332.
    • (2009) Clin Oral Implants Res. , vol.20 , pp. 327-332
    • Tabassum, A.1    Meijer, G.J.2    Wolke, J.G.C.3
  • 7
    • 0002172340 scopus 로고
    • Patient selection and preparation
    • Brånemark P-I, Zarb GA, Albrektsson T, eds Chicago, IL: Quintessence Publ Co
    • Lekholm U, Zarb GA. Patient selection and preparation. In: Brånemark P-I, Zarb GA, Albrektsson T, eds. Tissue Integrated Prostheses. Osseointegration in Clinical Dentistry. Chicago, IL: Quintessence Publ Co; 1985:199-209.
    • (1985) Tissue Integrated Prostheses. Osseointegration in Clinical Dentistry , pp. 199-209
    • Lekholm, U.1    Zarb, G.A.2
  • 8
    • 0344839329 scopus 로고    scopus 로고
    • Density of bone: Effect on surgical approach and healing
    • Misch CE, ed St Louis, MO: Mosby-Year Book
    • Misch CE. Density of bone: Effect on surgical approach and healing. In: Misch CE, ed. Contemporary Implant Dentistry. St Louis, MO: Mosby-Year Book; 1999:371-384.
    • (1999) Contemporary Implant Dentistry , pp. 371-384
    • Misch, C.E.1
  • 9
    • 0035261160 scopus 로고    scopus 로고
    • Bone classification: An objective scale of bone density using the computerized tomography scan
    • Norton MR, Gamble C. Bone classification: An objective scale of bone density using the computerized tomography scan. Clin Oral Implants Res. 2001;12:79-84.
    • (2001) Clin Oral Implants Res. , vol.12 , pp. 79-84
    • Norton, M.R.1    Gamble, C.2
  • 10
    • 77951894344 scopus 로고    scopus 로고
    • Preoperative evaluation of bone quality and bone density using a novel CT/microCT-based hard-normal-soft classification system
    • Rebaudi A, Trisi P, Cella R, et al. Preoperative evaluation of bone quality and bone density using a novel CT/microCT-based hard-normal-soft classification system. Int J Oral Maxillofac Implants. 2010; 25:75-85.
    • (2010) Int J Oral Maxillofac Implants. , vol.25 , pp. 75-85
    • Rebaudi, A.1    Trisi, P.2    Cella, R.3
  • 11
    • 34547174147 scopus 로고    scopus 로고
    • Relations between the bone density values from computerized tomography, and implant stability parameters: A clinical study of 230 regular platform implants
    • Turkyilmaz I, Tumer C, Ozbek EN, et al. Relations between the bone density values from computerized tomography, and implant stability parameters: A clinical study of 230 regular platform implants. J Clin Periodontol. 2007;34:716-722.
    • (2007) J Clin Periodontol. , vol.34 , pp. 716-722
    • Turkyilmaz, I.1    Tumer, C.2    Ozbek, E.N.3
  • 12
    • 79958813863 scopus 로고    scopus 로고
    • Peak insertion torque correlated to histologically and clinically evaluated bone density
    • Makary C, Rebaudi A, Mokbel N, et al. Peak insertion torque correlated to histologically and clinically evaluated bone density. Implant Dent. 2011;20:182-191.
    • (2011) Implant Dent. , vol.20 , pp. 182-191
    • Makary, C.1    Rebaudi, A.2    Mokbel, N.3
  • 13
    • 0042883974 scopus 로고    scopus 로고
    • De novo alveolar bone formation adjacent to endosseous implants. A model study in the dog
    • Berglundh T, Abrahamsson I, Lang NP, et al. De novo alveolar bone formation adjacent to endosseous implants. A model study in the dog. Clin Oral Impl Res. 2003;14:251-262.
    • (2003) Clin Oral Impl Res. , vol.14 , pp. 251-262
    • Berglundh, T.1    Abrahamsson, I.2    Lang, N.P.3
  • 15
    • 0027434751 scopus 로고
    • Periotest to monitor osseointegration and to check the occlusion in oral implantology
    • Schulte W, Lukas D. Periotest to monitor osseointegration and to check the occlusion in oral implantology. J Oral Implantol. 1993;19:23-32.
    • (1993) J Oral Implantol. , vol.19 , pp. 23-32
    • Schulte, W.1    Lukas, D.2
  • 16
    • 33748309280 scopus 로고    scopus 로고
    • Validity and clinical significance of biome-chanical testing of implant/bone interface
    • Aparicio C, Lang NP, Rangert B. Validity and clinical significance of biome-chanical testing of implant/bone interface. Clin Oral Implants Res. 2006;17(suppl 2):2-7.
    • (2006) Clin Oral Implants Res. , vol.17 , Issue.SUPPL. 2 , pp. 2-7
    • Aparicio, C.1    Lang, N.P.2    Rangert, B.3
  • 17
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996;7:261-267.
    • (1996) Clin Oral Implants Res. , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 18
    • 84870978125 scopus 로고    scopus 로고
    • Implant stability quotient (ISQ) vs direct in vitro measurement of primary stability (micromotion): Effect of bone density and insertion torque
    • Trisi P, Carlesi T, Colagiovanni M, et al. Implant stability quotient (ISQ) vs direct in vitro measurement of primary stability (micromotion): Effect of bone density and insertion torque. J Osteol Biomat. 2010;3:141-151.
    • (2010) J Osteol Biomat. , vol.3 , pp. 141-151
    • Trisi, P.1    Carlesi, T.2    Colagiovanni, M.3
  • 19
    • 32644446492 scopus 로고    scopus 로고
    • Resonance frequency analysis measurements of implants at placement surgery
    • Ostman PO, Hellman M, Wendelhag I, et al. Resonance frequency analysis measurements of implants at placement surgery. Int J Prosthodont. 2006;19:77-83.
    • (2006) Int J Prosthodont. , vol.19 , pp. 77-83
    • Ostman, P.O.1    Hellman, M.2    Wendelhag, I.3
  • 20
    • 65649110848 scopus 로고    scopus 로고
    • Biomechanical aspects of primary implant stability: A human cadaver study
    • Turkyilmaz I, Sennerby L, McGlumphy E, et al. Biomechanical aspects of primary implant stability: A human cadaver study. Clin Implant Dent Relat Res. 2009;11:113-119.
    • (2009) Clin Implant Dent Relat Res. , vol.11 , pp. 113-119
    • Turkyilmaz, I.1    Sennerby, L.2    McGlumphy, E.3
  • 21
    • 77953982728 scopus 로고    scopus 로고
    • Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length
    • Sim CPC, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length. Clin Oral Implants Res. 2010;21:598-604.
    • (2010) Clin Oral Implants Res. , vol.21 , pp. 598-604
    • Sim, C.P.C.1    Lang, N.P.2
  • 22
    • 0345304947 scopus 로고    scopus 로고
    • Dental implant stability and histo-morphometry: A correlation study in human cadavers
    • Nkenke E, Hahn M, Weinzierl K, et al. Dental implant stability and histo-morphometry: A correlation study in human cadavers. Clin Oral Impl Res. 2003;14:601-609.
    • (2003) Clin Oral Impl Res. , vol.14 , pp. 601-609
    • Nkenke, E.1    Hahn, M.2    Weinzierl, K.3
  • 23
    • 28844480575 scopus 로고    scopus 로고
    • Influence of cortical bone thickness and implant length on implant stability at the time of surgerydClinical, prospective, biomechanical and imaging study
    • Miyamoto I, Tsuboi Y, Wada E, et al. Influence of cortical bone thickness and implant length on implant stability at the time of surgerydClinical, prospective, biomechanical and imaging study. Bone. 2005:37;776-780.
    • (2005) Bone , vol.37 , pp. 776-780
    • Miyamoto, I.1    Tsuboi, Y.2    Wada, E.3
  • 24
    • 4444312847 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUn-ite single-tooth implants under immediate loading
    • da Cunha HA, Francischone CE, Filho HN, et al. A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUn-ite single-tooth implants under immediate loading. Int J Oral Maxillofac Implants. 2004;19:578-585.
    • (2004) Int J Oral Maxillofac Implants. , vol.19 , pp. 578-585
    • Da Cunha, H.A.1    Francischone, C.E.2    Filho, H.N.3
  • 25
    • 77954019654 scopus 로고    scopus 로고
    • Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: II. Implant surface modifications and implant diameter
    • Han J, Lulic M, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: II. Implant surface modifications and implant diameter. Clin Oral Implants Res. 2010;21:605-611.
    • (2010) Clin Oral Implants Res. , vol.21 , pp. 605-611
    • Han, J.1    Lulic, M.2    Lang, N.P.3
  • 26
    • 4644230057 scopus 로고    scopus 로고
    • Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants
    • Glauser R, Sennerby L, Meredith N, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res. 2004:15;428-434.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 428-434
    • Glauser, R.1    Sennerby, L.2    Meredith, N.3
  • 27
    • 0041960114 scopus 로고    scopus 로고
    • Stability measurements of a double-threaded titanium implant design with turned or oxidized surface
    • Rompen E, DaSilva D, Lundgren AK. Stability measurements of a double-threaded titanium implant design with turned or oxidized surface. Appl Osseoin-tegration Res. 2000;2:18-20.
    • (2000) Appl Osseoin-tegration Res. , vol.2 , pp. 18-20
    • Rompen, E.1    Dasilva, D.2    Lundgren, A.K.3
  • 28
    • 0023302919 scopus 로고
    • Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants
    • Johansson C, Albrektsson T. Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants. Int J Oral Maxillofac Implants. 1987;2:69-73.
    • (1987) Int J Oral Maxillofac Implants. , vol.2 , pp. 69-73
    • Johansson, C.1    Albrektsson, T.2
  • 29
    • 19844370349 scopus 로고
    • Histomorphometric and removal torque analysis for TiO2-blasted titanium implants: An experimental study on dogs
    • Gotfredsen K, Nimb L, Hjörting-Hansen R, et al. Histomorphometric and removal torque analysis for TiO2-blasted titanium implants: An experimental study on dogs. Clin Oral Implants Res. 1992;3:77-84.
    • (1992) Clin Oral Implants Res. , vol.3 , pp. 77-84
    • Gotfredsen, K.1    Nimb, L.2    Hjörting-Hansen, R.3
  • 31
    • 2942657499 scopus 로고    scopus 로고
    • Early loading (2 or 6 weeks) of sand blasted and acid-etched (SLA) it is implants in the posterior mandible. A 1-year randomized controlled clinical trial
    • Salvi GE, Gallini G, Lang NP. Early loading (2 or 6 weeks) of sand blasted and acid-etched (SLA) it is implants in the posterior mandible. A 1-year randomized controlled clinical trial. Clin Oral Implants Res. 2004;15:142-149.
    • (2004) Clin Oral Implants Res. , vol.15 , pp. 142-149
    • Salvi, G.E.1    Gallini, G.2    Lang, N.P.3
  • 32
    • 21344445511 scopus 로고    scopus 로고
    • Early wound healing around endosseous implants: A review of the literature
    • Raghavendra S, Wood M, Taylor T. Early wound healing around endosseous implants: A review of the literature. Int J Oral Maxillofac Implants. 2005;20:425-431.
    • (2005) Int J Oral Maxillofac Implants. , vol.20 , pp. 425-431
    • Raghavendra, S.1    Wood, M.2    Taylor, T.3
  • 33
    • 69849103056 scopus 로고    scopus 로고
    • The possible association among bone density values and histomorphometric evaluations of dental implant osteotomy sites: A preliminary study
    • Aksoy U, Eratalay K, Tözüm T. The possible association among bone density values and histomorphometric evaluations of dental implant osteotomy sites: A preliminary study. Implant Dent. 2009;18:316-325.
    • (2009) Implant Dent. , vol.18 , pp. 316-325
    • Aksoy, U.1    Eratalay, K.2    Tözüm, T.3
  • 34
    • 34547217298 scopus 로고    scopus 로고
    • Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation
    • Huwiler MA, Pjetursson BE, Bosshardt DD, et al. Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation. Clin Oral Impl Res. 2007;18:275-280.
    • (2007) Clin Oral Impl Res. , vol.18 , pp. 275-280
    • Huwiler, M.A.1    Pjetursson, B.E.2    Bosshardt, D.D.3
  • 35
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, et al. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg. 1999;28:297-303.
    • (1999) Int J Oral Maxillofac Surg. , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3
  • 36
    • 70349099976 scopus 로고    scopus 로고
    • Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants
    • Kahraman S, Bal B, Asar V, et al. Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants. J Oral Rehabil. 2009;36:755-761.
    • (2009) J Oral Rehabil. , vol.36 , pp. 755-761
    • Kahraman, S.1    Bal, B.2    Asar, V.3
  • 37
    • 60049098379 scopus 로고    scopus 로고
    • Implant stability in relation to osseointegra-tion: An experimental study in the Labrador dog
    • Abrahamsson I, Linder E, Lang NP. Implant stability in relation to osseointegra-tion: An experimental study in the Labrador dog. Clin Oral Implants Res. 2009;20:313-318.
    • (2009) Clin Oral Implants Res. , vol.20 , pp. 313-318
    • Abrahamsson, I.1    Linder, E.2    Lang, N.P.3
  • 38
    • 79958864887 scopus 로고    scopus 로고
    • ISQ (RFA) vs BIC and torque: A histomorpho-metric and biomechanical analysis in humans
    • Trisi P, Carlesi T, Rocci A, et al. ISQ (RFA) vs BIC and torque: A histomorpho-metric and biomechanical analysis in humans. J Osteol Biomat. 2010;1:81-91.
    • (2010) J Osteol Biomat. , vol.1 , pp. 81-91
    • Trisi, P.1    Carlesi, T.2    Rocci, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.