메뉴 건너뛰기




Volumn 66, Issue 5, 2011, Pages 1400-1404

Signal-to-noise ratio for hyperpolarized 3He MR imaging of human lungs: A 1.5 T and 3 T comparison

Author keywords

lungs; magnetic field strength; SNR

Indexed keywords

BIOLOGICAL ORGANS; BIOMEDICAL SIGNAL PROCESSING; INERT GASES; MAGNETIC RESONANCE IMAGING; PHASE INTERFACES;

EID: 80054822619     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22920     Document Type: Article
Times cited : (12)

References (20)
  • 8
    • 12844279813 scopus 로고    scopus 로고
    • Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs
    • Parra-Robles JM, Cross AR, Santyr GE,. Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs. Med Phys 2005; 32: 221-229.
    • (2005) Med Phys , vol.32 , pp. 221-229
    • Parra-Robles, J.M.1    Cross, A.R.2    Santyr, G.E.3
  • 10
    • 55049124700 scopus 로고    scopus 로고
    • RF coil loading measurements between 1 and 50 MHz to guide field-cycled MRI system design
    • Gilbert KM, Scholl TJ, Chronik BA,. RF coil loading measurements between 1 and 50 MHz to guide field-cycled MRI system design. Concepts Magn Reson Part B 2008; 33B: 177-191.
    • (2008) Concepts Magn Reson Part B , vol.33 B , pp. 177-191
    • Gilbert, K.M.1    Scholl, T.J.2    Chronik, B.A.3
  • 15
    • 49549133678 scopus 로고
    • The signal-to-noise ratio of the nuclear magnetic resonance experiment
    • Hoult DI, Richards RE,. The signal-to-noise ratio of the nuclear magnetic resonance experiment. J Magn Reson 1976; 24: 71-85.
    • (1976) J Magn Reson , vol.24 , pp. 71-85
    • Hoult, D.I.1    Richards, R.E.2
  • 17
    • 42749094084 scopus 로고    scopus 로고
    • Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs
    • Parra-Robles J, Dominguez-Viqueira W, Xu X, Ouriadov A, Santyr GE,. Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs. J Magn Reson 2008; 192: 85-91.
    • (2008) J Magn Reson , vol.192 , pp. 85-91
    • Parra-Robles, J.1    Dominguez-Viqueira, W.2    Xu, X.3    Ouriadov, A.4    Santyr, G.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.