-
1
-
-
0036260633
-
MRI of the lungs using hyperpolarized noble gases
-
Möller HE, Chen XJ, Saam B, Hagspiel KD, Johnson GA, Altes TA, de Lange EE, Kauczor HU,. MRI of the lungs using hyperpolarized noble gases. Magn Reson Med 2002; 47: 1029-1051.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1029-1051
-
-
Möller, H.E.1
Chen, X.J.2
Saam, B.3
Hagspiel, K.D.4
Johnson, G.A.5
Altes, T.A.6
De Lange, E.E.7
Kauczor, H.U.8
-
2
-
-
0034768510
-
Hyperpolarized noble gas MR imaging of the lung: Potential clinical applications
-
Salerno M, Altes TA, Mugler JP III, Nakatsu M, Hatabu H, de Lange EE,. Hyperpolarized noble gas MR imaging of the lung: potential clinical applications. Eur J Radiol 2001; 40: 33-44.
-
(2001)
Eur J Radiol
, vol.40
, pp. 33-44
-
-
Salerno, M.1
Altes, T.A.2
Mugler Iii, J.P.3
Nakatsu, M.4
Hatabu, H.5
De Lange, E.E.6
-
3
-
-
20144389175
-
3He lung imaging in an open access, very-low-field human magnetic resonance imaging system
-
3He lung imaging in an open access, very-low-field human magnetic resonance imaging system. Magn Reson Med 2005; 53: 745-749.
-
(2005)
Magn Reson Med
, vol.53
, pp. 745-749
-
-
Mair, R.W.1
Hrovat, M.I.2
Patz, S.3
Rosen, M.S.4
Ruset, I.C.5
Topulos, G.P.6
Tsai, L.L.7
Butler, J.P.8
Hersman, F.W.9
Walsworth, R.L.10
-
4
-
-
43249124925
-
Human pulmonary imaging and spectroscopy with hyperpolarized 129-Xe at 0.2T
-
Patz S, Muradian I, Hrovat MI, Ruset IC, Topulos G, Covrig SD, Frederick E, Hatabu H, Hersman FW, Butler JP,. Human pulmonary imaging and spectroscopy with hyperpolarized 129-Xe at 0.2T. Acad Radiol 2008; 15: 713-727.
-
(2008)
Acad Radiol
, vol.15
, pp. 713-727
-
-
Patz, S.1
Muradian, I.2
Hrovat, M.I.3
Ruset, I.C.4
Topulos, G.5
Covrig, S.D.6
Frederick, E.7
Hatabu, H.8
Hersman, F.W.9
Butler, J.P.10
-
7
-
-
42549103217
-
3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition
-
Holmes JH, O'Halloran RL, Brodsky EK, Jung Y, Block WF, Fain SB,. 3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition. Magn Reson Med 2008; 59: 1062-1071.
-
(2008)
Magn Reson Med
, vol.59
, pp. 1062-1071
-
-
Holmes, J.H.1
O'Halloran, R.L.2
Brodsky, E.K.3
Jung, Y.4
Block, W.F.5
Fain, S.B.6
-
8
-
-
12844279813
-
Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs
-
Parra-Robles JM, Cross AR, Santyr GE,. Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs. Med Phys 2005; 32: 221-229.
-
(2005)
Med Phys
, vol.32
, pp. 221-229
-
-
Parra-Robles, J.M.1
Cross, A.R.2
Santyr, G.E.3
-
9
-
-
54949098361
-
Experimental Validation of a Model for the Field Dependence of the SNR of Hyperpolarized Noble Gas MR Imaging of Rodent Lungs in Vivo
-
Parra-Robles J, Dominguez Viqueira W, Ouriadov A, Lam W, Abdeen N, Santyr GE,. Experimental Validation of a Model for the Field Dependence of the SNR of Hyperpolarized Noble Gas MR Imaging of Rodent Lungs In Vivo. Proceedings of the 14th Annual Meeting of ISMRM, Seattle, Washington, USA, 2006. p 1332.
-
(2006)
Proceedings of the 14th Annual Meeting of ISMRM, Seattle, Washington, USA
, pp. 1332
-
-
Parra-Robles, J.1
Dominguez Viqueira, W.2
Ouriadov, A.3
Lam, W.4
Abdeen, N.5
Santyr, G.E.6
-
10
-
-
55049124700
-
RF coil loading measurements between 1 and 50 MHz to guide field-cycled MRI system design
-
Gilbert KM, Scholl TJ, Chronik BA,. RF coil loading measurements between 1 and 50 MHz to guide field-cycled MRI system design. Concepts Magn Reson Part B 2008; 33B: 177-191.
-
(2008)
Concepts Magn Reson Part B
, vol.33 B
, pp. 177-191
-
-
Gilbert, K.M.1
Scholl, T.J.2
Chronik, B.A.3
-
12
-
-
80054805704
-
129Xe in the healthy human lung at l.5T and 3T
-
129Xe in the healthy human lung at l.5T and 3T. Proceedings of the 17th Annual Meeting of ISMRM, Honolulu, Hawaii, USA, 2009. p 2207.
-
(2009)
Proceedings of the 17th Annual Meeting of ISMRM, Honolulu, Hawaii, USA
, pp. 2207
-
-
Mugler, J.P.1
Dregely, I.M.2
Altes, T.A.3
Ketel, S.4
Ruset, I.C.5
Distelbrink, J.H.6
Chang, Y.7
Mata, J.F.8
Hersman, F.W.9
Ruppert, K.10
-
14
-
-
0030308425
-
129Xe MR
-
129Xe MR. J Magn Reson Series B 1996; 113: 179-183.
-
(1996)
J Magn Reson Series B
, vol.113
, pp. 179-183
-
-
Zhao, L.1
Mulkern, R.2
Tseng, C.H.3
Williamson, D.4
Patz, S.5
Kraft, R.6
Walsworth, R.L.7
Jolesz, F.A.8
Albert, M.S.9
-
15
-
-
49549133678
-
The signal-to-noise ratio of the nuclear magnetic resonance experiment
-
Hoult DI, Richards RE,. The signal-to-noise ratio of the nuclear magnetic resonance experiment. J Magn Reson 1976; 24: 71-85.
-
(1976)
J Magn Reson
, vol.24
, pp. 71-85
-
-
Hoult, D.I.1
Richards, R.E.2
-
17
-
-
42749094084
-
Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs
-
Parra-Robles J, Dominguez-Viqueira W, Xu X, Ouriadov A, Santyr GE,. Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs. J Magn Reson 2008; 192: 85-91.
-
(2008)
J Magn Reson
, vol.192
, pp. 85-91
-
-
Parra-Robles, J.1
Dominguez-Viqueira, W.2
Xu, X.3
Ouriadov, A.4
Santyr, G.E.5
-
18
-
-
54949117771
-
Finite element modeling and experimental validation of transverse relaxation and apparent diffusion coefficients of hyperpolarized noble gases in rodent lung
-
Parra-Robles J, Xu P, Dominguez Viqueira W, Lam W, Ouriadov A, McCormack D, Santyr GE,. Finite element modeling and experimental validation of transverse relaxation and apparent diffusion coefficients of hyperpolarized noble gases in rodent lung. Proceedings of the 15th Annual Meeting of ISMRM, Berlin, Germany, 2007. p 273.
-
(2007)
Proceedings of the 15th Annual Meeting of ISMRM, Berlin, Germany
, pp. 273
-
-
Parra-Robles, J.1
Xu, P.2
Dominguez Viqueira, W.3
Lam, W.4
Ouriadov, A.5
McCormack, D.6
Santyr, G.E.7
-
19
-
-
85091620223
-
3He in the rat lung using a 3D cones imaging strategy
-
3He in the rat lung using a 3D cones imaging strategy. Proceedings of the 17th Annual Meeting of ISMRM, Honolulu, Hawaii, USA, 2009. p 2199.
-
(2009)
Proceedings of the 17th Annual Meeting of ISMRM, Honolulu, Hawaii, USA
, pp. 2199
-
-
Wang, J.X.1
Stainsby, J.A.2
Ouriadov, A.V.3
Fox, M.4
Santyr, G.E.5
-
20
-
-
0031397685
-
3He MRI: Preliminary clinical experience in 18 patients with and without lung disease
-
3He MRI: preliminary clinical experience in 18 patients with and without lung disease. J Magn Reson Imaging 1997; 7: 538-543.
-
(1997)
J Magn Reson Imaging
, vol.7
, pp. 538-543
-
-
Kauczor, H.U.1
Ebert, M.2
Kreitner, K.F.3
Nilgens, H.4
Surkau, R.5
Heil, W.6
Hofmann, D.7
Otten, E.W.8
Thelen, M.9
|