-
1
-
-
0043165850
-
Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty [in French]
-
Galibert P., Deramond H., Rosat P., Le Gars D. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty [in French]. Neurochirurgie 1987, 33:166-168.
-
(1987)
Neurochirurgie
, vol.33
, pp. 166-168
-
-
Galibert, P.1
Deramond, H.2
Rosat, P.3
Le Gars, D.4
-
3
-
-
62349121784
-
Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): A randomised controlled trial
-
Wardlaw D., Cummings S.R., Van Meirhaeghe J., et al. Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): A randomised controlled trial. Lancet 2009, 373:1016-1024.
-
(2009)
Lancet
, vol.373
, pp. 1016-1024
-
-
Wardlaw, D.1
Cummings, S.R.2
Van Meirhaeghe, J.3
-
4
-
-
68249144371
-
A randomized trial of vertebroplasty for painful osteoporotic vertebral fractures
-
Buchbinder R., Osborne R.H., Ebeling P.R., et al. A randomized trial of vertebroplasty for painful osteoporotic vertebral fractures. N Engl J Med 2009, 361:557-568.
-
(2009)
N Engl J Med
, vol.361
, pp. 557-568
-
-
Buchbinder, R.1
Osborne, R.H.2
Ebeling, P.R.3
-
5
-
-
68249154874
-
A randomized trial of vertebroplasty for osteoporotic spinal fractures
-
Kallmes D.F., Comstock B.A., Heagerty P.J., et al. A randomized trial of vertebroplasty for osteoporotic spinal fractures. N Engl J Med 2009, 361:569-579.
-
(2009)
N Engl J Med
, vol.361
, pp. 569-579
-
-
Kallmes, D.F.1
Comstock, B.A.2
Heagerty, P.J.3
-
6
-
-
33748086788
-
Vertebroplasty and kyphoplasty. A systematic review of 69 clinical studies
-
Hulme P.A., Krebs J., Ferguson S.J., Berlemann U. Vertebroplasty and kyphoplasty. A systematic review of 69 clinical studies. Spine (Phila Pa 1976) 2006, 31:1983-2001.
-
(2006)
Spine (Phila Pa 1976)
, vol.31
, pp. 1983-2001
-
-
Hulme, P.A.1
Krebs, J.2
Ferguson, S.J.3
Berlemann, U.4
-
7
-
-
34248175352
-
Balloon kyphoplasty in the management of vertebral compression fractures: An updated systematic review and meta-analysis
-
Taylor R.S., Fritzell P., Taylor R.J. Balloon kyphoplasty in the management of vertebral compression fractures: An updated systematic review and meta-analysis. Eur Spine J 2007, 16:1085-1100.
-
(2007)
Eur Spine J
, vol.16
, pp. 1085-1100
-
-
Taylor, R.S.1
Fritzell, P.2
Taylor, R.J.3
-
8
-
-
33750571887
-
Balloon kyphoplasty and vertebroplasty for vertebral compression fractures. A comparative systematic review of efficacy and safety
-
Taylor R.S., Taylor R.J., Fritzell P. Balloon kyphoplasty and vertebroplasty for vertebral compression fractures. A comparative systematic review of efficacy and safety. Spine (Phila Pa 1976) 2006, 31:2747-2755.
-
(2006)
Spine (Phila Pa 1976)
, vol.31
, pp. 2747-2755
-
-
Taylor, R.S.1
Taylor, R.J.2
Fritzell, P.3
-
9
-
-
33845358253
-
Biomechanical evaluation of vertebroplasty and kyphoplasty with polymethyl methacrylate or calcium phosphate cement under cyclic loading
-
Wilke H.J., Mehnert U., Claes L.E., Bierschneider M.M., Jaksche H., Boszczyk B.M. Biomechanical evaluation of vertebroplasty and kyphoplasty with polymethyl methacrylate or calcium phosphate cement under cyclic loading. Spine (Phila Pa 1976) 2006, 31:2934-2941.
-
(2006)
Spine (Phila Pa 1976)
, vol.31
, pp. 2934-2941
-
-
Wilke, H.J.1
Mehnert, U.2
Claes, L.E.3
Bierschneider, M.M.4
Jaksche, H.5
Boszczyk, B.M.6
-
10
-
-
33750373862
-
High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty. An experimental model and study on cement leakage
-
Baroud G., Crookshank M., Bohner M. High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty. An experimental model and study on cement leakage. Spine (Phila Pa 1976) 2006, 31:2562-2568.
-
(2006)
Spine (Phila Pa 1976)
, vol.31
, pp. 2562-2568
-
-
Baroud, G.1
Crookshank, M.2
Bohner, M.3
-
11
-
-
6044249043
-
A finite element rheological model for polymethylmethacrylate flow: Analysis of the cement delivery in vertebroplasty
-
Baroud G., Yahia F.B. A finite element rheological model for polymethylmethacrylate flow: Analysis of the cement delivery in vertebroplasty. Proc Inst Mech Eng H 2004, 218:331-338.
-
(2004)
Proc Inst Mech Eng H
, vol.218
, pp. 331-338
-
-
Baroud, G.1
Yahia, F.B.2
-
12
-
-
13444261294
-
Injection biomechanics of bone cements used in vertebroplasty
-
Baroud G., Bohner M., Heini P., Steffen T. Injection biomechanics of bone cements used in vertebroplasty. Biomed Mater Eng 2004, 14:487-504.
-
(2004)
Biomed Mater Eng
, vol.14
, pp. 487-504
-
-
Baroud, G.1
Bohner, M.2
Heini, P.3
Steffen, T.4
-
13
-
-
33749662653
-
The effects of cement volume on clinical outcomes of percutaneous vertebroplasty
-
Kaufmann T.J., Trout A.T., Kallmes D.F. The effects of cement volume on clinical outcomes of percutaneous vertebroplasty. AJNR Am J Neuroradiol 2006, 27:1933-1937.
-
(2006)
AJNR Am J Neuroradiol
, vol.27
, pp. 1933-1937
-
-
Kaufmann, T.J.1
Trout, A.T.2
Kallmes, D.F.3
-
14
-
-
0019947037
-
A method for the study of undecalcified bones and teeth with attached soft tissues. The Säge-Schliff (sawing and grinding) technique
-
Donath K., Breuner G. A method for the study of undecalcified bones and teeth with attached soft tissues. The Säge-Schliff (sawing and grinding) technique. J Oral Pathol 1982, 11:318-326.
-
(1982)
J Oral Pathol
, vol.11
, pp. 318-326
-
-
Donath, K.1
Breuner, G.2
-
15
-
-
39149129995
-
Fracture and dislocation classification compendium-2007. Orthopaedic Trauma Association classification, database and outcomes committee
-
Marsh J.L., Slongo T.F., Agel J., et al. Fracture and dislocation classification compendium-2007. Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 2007, 21:S1-S133.
-
(2007)
J Orthop Trauma
, vol.21
-
-
Marsh, J.L.1
Slongo, T.F.2
Agel, J.3
-
16
-
-
40649108300
-
Progressive collapse of PMMA-augmented vertebra: A report of three cases
-
Shin D.A., Kim K.N., Shin H.C., Kim S.H., Yoon D.H. Progressive collapse of PMMA-augmented vertebra: A report of three cases. Zentralbl Neurochir 2008, 69:43-46.
-
(2008)
Zentralbl Neurochir
, vol.69
, pp. 43-46
-
-
Shin, D.A.1
Kim, K.N.2
Shin, H.C.3
Kim, S.H.4
Yoon, D.H.5
-
17
-
-
84860708365
-
Mechanical variables affecting balloon kyphoplasty outcome-A finite element study
-
Dabirrahmani D., Becker S., Hogg M., Appleyard R., Baroud G., Gillies M. Mechanical variables affecting balloon kyphoplasty outcome-A finite element study. Comput Methods Biomech Biomed Engin 2012, 15:211-220.
-
(2012)
Comput Methods Biomech Biomed Engin
, vol.15
, pp. 211-220
-
-
Dabirrahmani, D.1
Becker, S.2
Hogg, M.3
Appleyard, R.4
Baroud, G.5
Gillies, M.6
-
18
-
-
77956918949
-
A probabilistic finite element analysis of the stresses in the augmented vertebral body after vertebroplasty
-
Rohlmann A., Boustani H.N., Bergmann G., Zander T. A probabilistic finite element analysis of the stresses in the augmented vertebral body after vertebroplasty. Eur Spine J 2010, 19:1585-1595.
-
(2010)
Eur Spine J
, vol.19
, pp. 1585-1595
-
-
Rohlmann, A.1
Boustani, H.N.2
Bergmann, G.3
Zander, T.4
-
19
-
-
77949496536
-
Clinical experience with high-viscosity cements for percutaneous vertebral body augmentation: Occurrence, degree, and location of cement leakage compared with kyphoplasty
-
Georgy B.A. Clinical experience with high-viscosity cements for percutaneous vertebral body augmentation: Occurrence, degree, and location of cement leakage compared with kyphoplasty. AJNR Am J Neuroradiol 2010, 31:504-508.
-
(2010)
AJNR Am J Neuroradiol
, vol.31
, pp. 504-508
-
-
Georgy, B.A.1
-
20
-
-
77957349778
-
A clinical comparative study on low versus medium viscosity polymethylmetacrylate bone cement in percutaneous vertebroplasty. Viscosity associated with cement leakage
-
Nieuwenhuijse M.J., Muijs S.P., van Erkel A.R., Dijkstra S.P. A clinical comparative study on low versus medium viscosity polymethylmetacrylate bone cement in percutaneous vertebroplasty. Viscosity associated with cement leakage. Spine (Phila Pa 1976) 2010, 35:E1037-E1044.
-
(2010)
Spine (Phila Pa 1976)
, vol.35
-
-
Nieuwenhuijse, M.J.1
Muijs, S.P.2
van Erkel, A.R.3
Dijkstra, S.P.4
-
21
-
-
84861101861
-
Analysis of retrieved hip resurfacing arthroplasties reveals the interrelationship between interface hyperosteoidosis and demineralization of viable bone trabeculae
-
Breer S., Krause M., Busse B., et al. Analysis of retrieved hip resurfacing arthroplasties reveals the interrelationship between interface hyperosteoidosis and demineralization of viable bone trabeculae. J Orthop Res 2012, 30:1155-1161.
-
(2012)
J Orthop Res
, vol.30
, pp. 1155-1161
-
-
Breer, S.1
Krause, M.2
Busse, B.3
-
22
-
-
84864281783
-
Cementation and interface analysis of early failure cases after hip-resurfacing arthroplasty
-
Krause M., Breer S., Hahn M., et al. Cementation and interface analysis of early failure cases after hip-resurfacing arthroplasty. Int Orthop 2012, 36:1333-1340.
-
(2012)
Int Orthop
, vol.36
, pp. 1333-1340
-
-
Krause, M.1
Breer, S.2
Hahn, M.3
-
23
-
-
77955551312
-
Femoral component loosening after hip resurfacing arthroplasty
-
Zustin J., Hahn M., Morlock M.M., Rüther W., Amling M., Sauter G. Femoral component loosening after hip resurfacing arthroplasty. Skeletal Radiol 2010, 39:747-756.
-
(2010)
Skeletal Radiol
, vol.39
, pp. 747-756
-
-
Zustin, J.1
Hahn, M.2
Morlock, M.M.3
Rüther, W.4
Amling, M.5
Sauter, G.6
|