메뉴 건너뛰기




Volumn 37, Issue 12, 2012, Pages 2488-2494

Biomechanical analysis of a volar variable-angle locking plate: The effect of capturing a distal radial styloid fragment

Author keywords

Biomechanics; distal radius fracture; variable angle locking plate; volar locking plate

Indexed keywords

ARTICLE; BIOMECHANICS; CONTROLLED STUDY; DATA ANALYSIS; HUMAN; JOINT STIFFNESS; OSTEOTOMY; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RADIUS FRACTURE; TREATMENT FAILURE; VOLAR PLATE FIXATION;

EID: 84869487013     PISSN: 03635023     EISSN: 15316564     Source Type: Journal    
DOI: 10.1016/j.jhsa.2012.09.009     Document Type: Article
Times cited : (18)

References (42)
  • 2
    • 0027365036 scopus 로고
    • Epidemiology of acute wrist trauma
    • C.F. Larsen, J. Lauritsen Epidemiology of acute wrist trauma Int J Epidemiol 22 1993 911 916
    • (1993) Int J Epidemiol , vol.22 , pp. 911-916
    • Larsen, C.F.1    Lauritsen, J.2
  • 4
    • 0036241905 scopus 로고    scopus 로고
    • Palmar plating for dorsally displaced fractures of the distal radius
    • M. Kamano, Y. Honda, K. Kazuki, M. Yasuda Palmar plating for dorsally displaced fractures of the distal radius Clin Orthop Relat Res 397 2002 403 408
    • (2002) Clin Orthop Relat Res , vol.397 , pp. 403-408
    • Kamano, M.1    Honda, Y.2    Kazuki, K.3    Yasuda, M.4
  • 5
    • 0033219263 scopus 로고    scopus 로고
    • Plate fixation of fractures of the distal aspect of the radius: Relative indications
    • J.B. Jupiter Plate fixation of fractures of the distal aspect of the radius: relative indications J Orthop Trauma 13 1999 559 569
    • (1999) J Orthop Trauma , vol.13 , pp. 559-569
    • Jupiter, J.B.1
  • 6
    • 36649023113 scopus 로고    scopus 로고
    • Treatment of unstable distal radial fractures with the volar locking plating system Surgical technique
    • K.C. Chung, E.A. Petruska Treatment of unstable distal radial fractures with the volar locking plating system Surgical technique J Bone Joint Surg 89A 2007 256 266
    • (2007) J Bone Joint Surg , vol.89 A , pp. 256-266
    • Chung, K.C.1    Petruska, E.A.2
  • 7
    • 22544478434 scopus 로고    scopus 로고
    • Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates
    • D.S. Musgrave, R.S. Idler Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates J Hand Surg 30A 2005 743 749
    • (2005) J Hand Surg , vol.30 A , pp. 743-749
    • Musgrave, D.S.1    Idler, R.S.2
  • 8
    • 34548439901 scopus 로고    scopus 로고
    • Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: A retrospective study
    • S. Rein, H. Schikore, W. Schneiders, M. Amlang, H. Zwipp Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study J Hand Surg 32A 2007 954 961
    • (2007) J Hand Surg , vol.32 A , pp. 954-961
    • Rein, S.1    Schikore, H.2    Schneiders, W.3    Amlang, M.4    Zwipp, H.5
  • 9
    • 4444358605 scopus 로고    scopus 로고
    • Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: Clinical experience and a laboratory comparison with double plating
    • K.A. Egol, E. Sue, N.C. Tejwani, S.H. Sims, F.J. Kummer, K.J. Koval Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating Crit Care Med 57 2004 340 346
    • (2004) Crit Care Med , vol.57 , pp. 340-346
    • Egol, K.A.1    Sue, E.2    Tejwani, N.C.3    Sims, S.H.4    Kummer, F.J.5    Koval, K.J.6
  • 10
    • 33646477698 scopus 로고    scopus 로고
    • Fixation of diaphyseal fractures with a segmental defect: A biomechanical comparison of locked and conventional plating techniques
    • E. Fulkerson, K.A. Egol, E.N. Kubiak, F. Liporace, F.J. Kummer, K.J. Koval Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques J Trauma 60 2006 830 835
    • (2006) J Trauma , vol.60 , pp. 830-835
    • Fulkerson, E.1    Egol, K.A.2    Kubiak, E.N.3    Liporace, F.4    Kummer, F.J.5    Koval, K.J.6
  • 11
    • 2642514242 scopus 로고    scopus 로고
    • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
    • J. Korner, G. Diederichs, M. Arzdorf, H. Lill, C. Josten, E. Schneider A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates J Orthop Trauma 18 2004 286 293
    • (2004) J Orthop Trauma , vol.18 , pp. 286-293
    • Korner, J.1    Diederichs, G.2    Arzdorf, M.3    Lill, H.4    Josten, C.5    Schneider, E.6
  • 12
    • 16244400503 scopus 로고    scopus 로고
    • A biomechanical comparison of a dorsal 3.5 mm T-plate and a volar fixed angle plate in a model of dorsally unstable distal radius fractures
    • F.A. Liporace, S. Gupta, G.K. Jeong, M. Stracher, F. Kummer, K.A. Egol A biomechanical comparison of a dorsal 3.5 mm T-plate and a volar fixed angle plate in a model of dorsally unstable distal radius fractures J Orthop Trauma 19 2005 187 191
    • (2005) J Orthop Trauma , vol.19 , pp. 187-191
    • Liporace, F.A.1    Gupta, S.2    Jeong, G.K.3    Stracher, M.4    Kummer, F.5    Egol, K.A.6
  • 14
    • 58149394984 scopus 로고    scopus 로고
    • Polyaxial locking plate fixation in distal femur fractures: A biomechanical comparison
    • K.J. Wilkens, S. Curtiss, M.A. Lee Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison J Orthop Trauma 22 2008 624 628
    • (2008) J Orthop Trauma , vol.22 , pp. 624-628
    • Wilkens, K.J.1    Curtiss, S.2    Lee, M.A.3
  • 15
    • 0027315373 scopus 로고
    • Distal radius fractures: Patterns of articular fragmentation
    • C.P. Melone Distal radius fractures: patterns of articular fragmentation Orthop Clin North Am 24 1993 239 253
    • (1993) Orthop Clin North Am , vol.24 , pp. 239-253
    • Melone, C.P.1
  • 16
    • 33646477698 scopus 로고    scopus 로고
    • Fixation of diaphyseal fractures with a segmental defect: A biomechanical comparison of locked and conventional plating techniques
    • E. Fulkerson, K.A. Egol, E.N. Kubiak, F. Liporace, F.J. Kummer, K.J. Koval Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques J Trauma 60 2006 830 835
    • (2006) J Trauma , vol.60 , pp. 830-835
    • Fulkerson, E.1    Egol, K.A.2    Kubiak, E.N.3    Liporace, F.4    Kummer, F.J.5    Koval, K.J.6
  • 17
    • 33846101111 scopus 로고    scopus 로고
    • Biomechanical analysis of distal femur fracture fixation: Fixed-angle screw-plate construct versus condylar blade plate
    • T.F. Higgins, G. Pittman, J. Hines, K.N. Bachus Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate J Orthop Trauma 21 2007 43 46
    • (2007) J Orthop Trauma , vol.21 , pp. 43-46
    • Higgins, T.F.1    Pittman, G.2    Hines, J.3    Bachus, K.N.4
  • 18
    • 33748965764 scopus 로고    scopus 로고
    • The effect of plate rotation on the stiffness of femoral LISS: A mechanical study
    • A. Khalafi, S. Curtiss, S. Hazelwood, P. Wolinsky The effect of plate rotation on the stiffness of femoral LISS: a mechanical study J Orthop Trauma 20 2006 542 546
    • (2006) J Orthop Trauma , vol.20 , pp. 542-546
    • Khalafi, A.1    Curtiss, S.2    Hazelwood, S.3    Wolinsky, P.4
  • 20
    • 33748746234 scopus 로고    scopus 로고
    • A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model
    • F.A. Liporace, E.N. Kubiak, G.K. Jeong, K. Iesaka, K.A. Egol, K.J. Koval A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model J Trauma 61 2006 668 672
    • (2006) J Trauma , vol.61 , pp. 668-672
    • Liporace, F.A.1    Kubiak, E.N.2    Jeong, G.K.3    Iesaka, K.4    Egol, K.A.5    Koval, K.J.6
  • 21
    • 0034193846 scopus 로고    scopus 로고
    • Distal radial metaphyseal forces in an extrinsic grip model: Implications for postfracture rehabilitation
    • M.D. Putnam, N.J. Meyer, E.W. Nelson, D. Gesensway, J.L. Lewis Distal radial metaphyseal forces in an extrinsic grip model: implications for postfracture rehabilitation J Hand Surg 25A 2000 469 475
    • (2000) J Hand Surg , vol.25 A , pp. 469-475
    • Putnam, M.D.1    Meyer, N.J.2    Nelson, E.W.3    Gesensway, D.4    Lewis, J.L.5
  • 23
    • 33750802999 scopus 로고    scopus 로고
    • Internal fixation of dorsally displaced fractures of the distal part of the radius A biomechanical analysis of volar plate fracture stability
    • A.A. Willis, K. Kutsumi, M.E. Zobitz, W.P. Cooney III Internal fixation of dorsally displaced fractures of the distal part of the radius A biomechanical analysis of volar plate fracture stability J Bone Joint Surg 88A 2006 2411 2417
    • (2006) J Bone Joint Surg , vol.88 A , pp. 2411-2417
    • Willis, A.A.1    Kutsumi, K.2    Zobitz, M.E.3    Cooney Iii., W.P.4
  • 24
    • 0027457960 scopus 로고
    • Geometric variable from DXA of the radius predict forearm fracture load in vitro
    • E.R. Myers, A.T. Hecker, D.S. Rooks, J.A. Hipp, W.C. Hayes Geometric variable from DXA of the radius predict forearm fracture load in vitro Calcif Tissue Int 52 1993 199 204
    • (1993) Calcif Tissue Int , vol.52 , pp. 199-204
    • Myers, E.R.1    Hecker, A.T.2    Rooks, D.S.3    Hipp, J.A.4    Hayes, W.C.5
  • 26
    • 80053572641 scopus 로고    scopus 로고
    • Evaluation of a polyaxial angle-stable volar plate in a distal radius C-fracture model - A biomechanical study
    • S. Rausch, K. Klos, H. Stephan, K. Hofmeier, F. Gras, M. Windolf Evaluation of a polyaxial angle-stable volar plate in a distal radius C-fracture model - a biomechanical study Injury 42 2011 1248 1252
    • (2011) Injury , vol.42 , pp. 1248-1252
    • Rausch, S.1    Klos, K.2    Stephan, H.3    Hofmeier, K.4    Gras, F.5    Windolf, M.6
  • 27
    • 55549145079 scopus 로고    scopus 로고
    • Structural properties of fourth-generation composite femurs and tibias
    • A.D. Heiner Structural properties of fourth-generation composite femurs and tibias J Biomechanics 41 2008 3282 3284
    • (2008) J Biomechanics , vol.41 , pp. 3282-3284
    • Heiner, A.D.1
  • 28
    • 34250789798 scopus 로고    scopus 로고
    • Fatigue performance of composite analogue femur constructs under high activity loading
    • A.C.M. Chong, E.A. Friis, G.P. Ballard, P.J. Czuwala, F.W. Cooke Fatigue performance of composite analogue femur constructs under high activity loading Annal Biomed Eng 35 2007 1196 1205
    • (2007) Annal Biomed Eng , vol.35 , pp. 1196-1205
    • Chong, A.C.M.1    Friis, E.A.2    Ballard, G.P.3    Czuwala, P.J.4    Cooke, F.W.5
  • 29
    • 60549092945 scopus 로고    scopus 로고
    • Cancellous bone screw purchase: A comparison of synthetic femurs, human femurs, and finite element analysis
    • R. Zdero, M. Olsen, H. Bougherara, E.H. Schemitsch Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis J Eng Med 222 2008 1175 1183
    • (2008) J Eng Med , vol.222 , pp. 1175-1183
    • Zdero, R.1    Olsen, M.2    Bougherara, H.3    Schemitsch, E.H.4
  • 30
    • 54849433115 scopus 로고    scopus 로고
    • Structural properties of a novel design of composite analogue humeri models
    • J.T. Dunlap, A.C.M. Chong, G.L. Lucas, F.W. Cooke Structural properties of a novel design of composite analogue humeri models Annal Biomed Eng 36 2008 1922 1926
    • (2008) Annal Biomed Eng , vol.36 , pp. 1922-1926
    • Dunlap, J.T.1    Chong, A.C.M.2    Lucas, G.L.3    Cooke, F.W.4
  • 32
    • 77954828112 scopus 로고    scopus 로고
    • The effect of cortex thickness on intact femur biomechanics: A comparison of finite element analysis with synthetic femurs
    • R. Zdero, H. Bougherara, A. Dubov, S. Shah, P. Zalzal, A. Mahfud The effect of cortex thickness on intact femur biomechanics: a comparison of finite element analysis with synthetic femurs J Eng Med 224 2009 831 840
    • (2009) J Eng Med , vol.224 , pp. 831-840
    • Zdero, R.1    Bougherara, H.2    Dubov, A.3    Shah, S.4    Zalzal, P.5    Mahfud, A.6
  • 33
    • 77955361755 scopus 로고    scopus 로고
    • Mapping the strain distribution on the proximal femur with titanium and flexible-stemmed implants using digital image correlation
    • E. Tayton, S. Evans, D. O'Doherty Mapping the strain distribution on the proximal femur with titanium and flexible-stemmed implants using digital image correlation J Bone Joint Surg 92B 2010 1176 1181
    • (2010) J Bone Joint Surg , vol.92 B , pp. 1176-1181
    • Tayton, E.1    Evans, S.2    O'Doherty, D.3
  • 34
    • 77952012233 scopus 로고    scopus 로고
    • Mechanical evaluation of large size fourth-generation composite femur and tibia models
    • M.P. Gardner, A.C.M. Chong, A.G. Pollock, P.H. Wooley Mechanical evaluation of large size fourth-generation composite femur and tibia models Annal Biomed Eng 38 2010 613 620
    • (2010) Annal Biomed Eng , vol.38 , pp. 613-620
    • Gardner, M.P.1    Chong, A.C.M.2    Pollock, A.G.3    Wooley, P.H.4
  • 35
    • 34250750507 scopus 로고    scopus 로고
    • Fracture toughness and fatigue crack propagation rate of short fiber reinforced epoxy composites for analogue cortical bone
    • A.C. Chong, F. Miller, M. Buxton, E.A. Friis Fracture toughness and fatigue crack propagation rate of short fiber reinforced epoxy composites for analogue cortical bone J Biomech Eng 129 2007 487 493
    • (2007) J Biomech Eng , vol.129 , pp. 487-493
    • Chong, A.C.1    Miller, F.2    Buxton, M.3    Friis, E.A.4
  • 37
    • 66149108473 scopus 로고    scopus 로고
    • Stiffness modulation of locking plate constructs using near cortical slotted holes: A preliminary study
    • J.M. Gardner, S.E. Nork, P. Huber, J.C. Krieg Stiffness modulation of locking plate constructs using near cortical slotted holes: a preliminary study J Orthop Trauma 23 2009 281 287
    • (2009) J Orthop Trauma , vol.23 , pp. 281-287
    • Gardner, J.M.1    Nork, S.E.2    Huber, P.3    Krieg, J.C.4
  • 39
    • 84862614469 scopus 로고    scopus 로고
    • Peri-anterior cruciate ligament reconstruction femur fracture: A biomechanical analysis of the femoral tunnel as a stress riser
    • Y. Han, Z. Sardar, S. Mcgrail, T. Steffen, P.A. Martineau Peri-anterior cruciate ligament reconstruction femur fracture: a biomechanical analysis of the femoral tunnel as a stress riser Knee Surg Sports Traumatol Arthrosc 19 2011 S577 S585
    • (2011) Knee Surg Sports Traumatol Arthrosc , vol.19
    • Han, Y.1    Sardar, Z.2    McGrail, S.3    Steffen, T.4    Martineau, P.A.5
  • 40
    • 79959344371 scopus 로고    scopus 로고
    • Biomechanical analysis of a synthetic femur spiral fracture model: Influence of different materials on the stiffness in flexible intramedullary nailing
    • M.M. Kaiser, L.M. Wessel, G. Zachert, C. Stratmann, R. Eggert, N. Gros Biomechanical analysis of a synthetic femur spiral fracture model: influence of different materials on the stiffness in flexible intramedullary nailing Clin Biomech 26 2011 592 597
    • (2011) Clin Biomech , vol.26 , pp. 592-597
    • Kaiser, M.M.1    Wessel, L.M.2    Zachert, G.3    Stratmann, C.4    Eggert, R.5    Gros, N.6
  • 41
    • 79251584989 scopus 로고    scopus 로고
    • The comparative stability of screw versus plate versus screw and plate coronoid fixation
    • J.E. Budoff, D.N. Meyers, C.G. Ambrose The comparative stability of screw versus plate versus screw and plate coronoid fixation J Hand Surg 36A 2011 238 245
    • (2011) J Hand Surg , vol.36 A , pp. 238-245
    • Budoff, J.E.1    Meyers, D.N.2    Ambrose, C.G.3
  • 42
    • 79953743713 scopus 로고    scopus 로고
    • Biomechanical properties of volar hybrid and locked plate fixation in distal radius fractures
    • S.C. Sokol, D.F. Amanatullah, S.C. Curtiss, R.M. Szabo Biomechanical properties of volar hybrid and locked plate fixation in distal radius fractures J Hand Surg 36A 2011 591 597
    • (2011) J Hand Surg , vol.36 A , pp. 591-597
    • Sokol, S.C.1    Amanatullah, D.F.2    Curtiss, S.C.3    Szabo, R.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.