메뉴 건너뛰기




Volumn 36, Issue 4, 2011, Pages 591-597

Biomechanical properties of volar hybrid and locked plate fixation in distal radius fractures

Author keywords

Biomechanical; distal radius fracture; hybrid fixation; internal fixation; locking; volar plate

Indexed keywords

ALL LOCKING PLATE; ARTICLE; BIOMECHANICS; BONE PLATE; BONE SCREW; CONTROLLED STUDY; FRACTURE FIXATION; OSTEOPOROSIS; OSTEOTOMY; PRIORITY JOURNAL; RADIUS FRACTURE; VOLAR PLATE FIXATION;

EID: 79953743713     PISSN: 03635023     EISSN: 15316564     Source Type: Journal    
DOI: 10.1016/j.jhsa.2010.12.032     Document Type: Article
Times cited : (20)

References (31)
  • 1
    • 77951045277 scopus 로고    scopus 로고
    • Unstable distal radius fractures in the elderly patient - Volar fixed-angle plate osteosynthesis prevents secondary loss of reduction
    • Figl M, Weninger P, Jurkowitsch J, Hofbauer M, Schauer J, Leixnering M. Unstable distal radius fractures in the elderly patient - volar fixed-angle plate osteosynthesis prevents secondary loss of reduction. J Trauma 2010;68:992-998.
    • (2010) J Trauma , vol.68 , pp. 992-998
    • Figl, M.1    Weninger, P.2    Jurkowitsch, J.3    Hofbauer, M.4    Schauer, J.5    Leixnering, M.6
  • 2
    • 79953740378 scopus 로고    scopus 로고
    • Available at: Accessed July 10, 2010
    • National Osteoporosis Foundation. Fast Facts: Fractures. Available at: http://www.nof.org/node/40. Accessed July 10, 2010.
    • Fast Facts: Fractures
  • 4
    • 0038651175 scopus 로고    scopus 로고
    • Osteosynthesis of distal radial fractures with a volar locking screw plate system
    • Drobetz H Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 2003;27:1-6.
    • (2003) Int Orthop , vol.27 , pp. 1-6
    • Drobetz, H.1    Kutscha-Lissberg, E.2
  • 5
    • 0742270693 scopus 로고    scopus 로고
    • Volar Fixed-Angle Plate Fixation for Unstable Distal Radius Fractures in the Elderly Patient
    • DOI 10.1016/j.jhsa.2003.09.015
    • Orbay JL, Fernandez DL. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg 2004;29A:96-102. (Pubitemid 38146410)
    • (2004) Journal of Hand Surgery , vol.29 , Issue.1 , pp. 96-102
    • Orbay, J.L.1    Fernandez, D.L.2
  • 6
    • 0036130725 scopus 로고    scopus 로고
    • Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    • DOI 10.1053/jhsu.2002.32081
    • Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg 2002;27A:205-215. (Pubitemid 34241185)
    • (2002) Journal of Hand Surgery , vol.27 , Issue.2 , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2
  • 8
    • 33750802999 scopus 로고    scopus 로고
    • Internal fixation of dorsally displaced fractures of the distal part of the radius: A biomechanical analysis of volar plate fracture stability
    • DOI 10.2106/JBJS.E.00946
    • Willis AA, Kutsumi K, Zobitz ME, Cooney WP III. Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability. J Bone Joint Surg 2006;88A:2411-2417. (Pubitemid 44713828)
    • (2006) Journal of Bone and Joint Surgery - Series A , vol.88 , Issue.11 , pp. 2411-2417
    • Willis, A.A.1    Kutsumi, K.2    Zobitz, M.E.3    Cooney III, W.P.4
  • 9
    • 34247585543 scopus 로고    scopus 로고
    • Mechanical Characteristics of Locking and Compression Plate Constructs Applied Dorsally to Distal Radius Fractures
    • DOI 10.1016/j.jhsa.2007.03.005, PII S0363502307003139
    • Boswell S, McIff TE, Trease CA, Toby EB. Mechanical characteristics of locking and compression plate constructs applied dorsally to distal radius fractures. J Hand Surg 2007;32A:623-629. (Pubitemid 46669835)
    • (2007) Journal of Hand Surgery , vol.32 , Issue.5 , pp. 623-629
    • Boswell, S.1    McIff, T.E.2    Trease, C.A.3    Toby, E.B.4
  • 11
    • 43049137358 scopus 로고    scopus 로고
    • Biomechanical strength of the Peri-Loc proximal tibial plate: A comparison of all-locked versus hybrid locked/nonlocked screw configurations
    • DOI 10.1097/BOT.0b013e31817279b8, PII 0000513120080500000005
    • Estes C, Rhee P, Shrader MW, Csavina K, Jacofsky MC, Jacofsky DJ. Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations. J Orthop Trauma 2008;22:312-316. (Pubitemid 351630244)
    • (2008) Journal of Orthopaedic Trauma , vol.22 , Issue.5 , pp. 312-316
    • Estes, C.1    Rhee, P.2    Shrader, M.W.3    Csavina, K.4    Jacofsky, M.C.5    Jacofsky, D.J.6
  • 12
    • 33646506008 scopus 로고    scopus 로고
    • Volar fixation for dorsally angulated extra-articular fractures of the distal radius: A biomechanical study
    • Koh S, Morris RP, Patterson RM, Kearney JP, Buford WL Jr, Viegas SF. Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study. J Hand Surg 2006;31A:771-779.
    • (2006) J Hand Surg , vol.31 A , pp. 771-779
    • Koh, S.1    Morris, R.P.2    Patterson, R.M.3    Kearney, J.P.4    Buford Jr., W.L.5    Viegas, S.F.6
  • 13
    • 35448968338 scopus 로고    scopus 로고
    • A surrogate long-bone model with osteoporotic material properties for biomechanical testing of fracture implants
    • DOI 10.1016/j.jbiomech.2007.04.024, PII S0021929007001972
    • Sommers MB, Fitzpatrick DC, Madey SM, Vande Zanderschulp C, Bottlang M. A surrogate long-bone model with osteoporotic material properties for biomechanical testing of fracture implants. J Biomech 2007;40:3297-3304. (Pubitemid 47632584)
    • (2007) Journal of Biomechanics , vol.40 , Issue.15 , pp. 3297-3304
    • Sommers, M.B.1    Fitzpatrick, D.C.2    Madey, S.M.3    Vande, Z.C.4    Bottlang, M.5
  • 14
    • 0028331088 scopus 로고
    • Hydroxyapatite enhancement of posterior spinal instrumentation fixation
    • Phila PA
    • Spivak JM, Neuwirth MG, Labiak JJ, Kummer FJ, Ricci JL. Hydroxyapatite enhancement of posterior spinal instrumentation fixation. Spine (Phila PA 1976) 1994;19:955-964.
    • (1976) Spine , vol.19 , pp. 955-964
    • Spivak, J.M.1    Neuwirth, M.G.2    Labiak, J.J.3    Kummer, F.J.4    Ricci, J.L.5
  • 16
    • 0038627493 scopus 로고    scopus 로고
    • Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model
    • DOI 10.1016/S0266-7681(03)00011-1
    • Leung F, Zhu L, Ho H, Lu WW, Chow SP. Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - a biomechanical study in a cadaveric model. J Hand Surg 2003;28B:263-266. (Pubitemid 36612083)
    • (2003) Journal of Hand Surgery , vol.28 B , Issue.3 , pp. 263-266
    • Leung, F.1    Zhu, L.2    Ho, H.3    Lu, W.W.4    Chow, S.P.5
  • 17
    • 34250889457 scopus 로고    scopus 로고
    • Volar Versus Dorsal Fixed-Angle Fixation of Dorsally Unstable Extra-Articular Distal Radius Fractures: A Biomechanic Study
    • DOI 10.1016/j.jhsa.2007.04.016, PII S0363502307004698
    • McCall TA, Conrad B, Badman B, Wright T. Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanic study. J Hand Surg 2007;32A:806-812. (Pubitemid 46991175)
    • (2007) Journal of Hand Surgery , vol.32 , Issue.6 , pp. 806-812
    • McCall, T.A.1    Conrad, B.2    Badman, B.3    Wright, T.4
  • 18
    • 72449205194 scopus 로고    scopus 로고
    • Influence of an additional locking screw on fracture reduction after volar fixed-angle plating-introduction of the "protection screw" in an extra-articular distal radius fracture model
    • Weninger P, Schueller M, Drobetz H, Jamek M, Redl H, Tschegg E. Influence of an additional locking screw on fracture reduction after volar fixed-angle plating-introduction of the "protection screw" in an extra-articular distal radius fracture model. J Trauma 2009;67:746-751.
    • (2009) J Trauma , vol.67 , pp. 746-751
    • Weninger, P.1    Schueller, M.2    Drobetz, H.3    Jamek, M.4    Redl, H.5    Tschegg, E.6
  • 19
    • 77952707717 scopus 로고    scopus 로고
    • Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: Biomechanical study
    • Mehling I, Muller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM. Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg 2010;35A:885-891.
    • (2010) J Hand Surg , vol.35 A , pp. 885-891
    • Mehling, I.1    Muller, L.P.2    Delinsky, K.3    Mehler, D.4    Burkhart, K.J.5    Rommens, P.M.6
  • 21
    • 0142168925 scopus 로고    scopus 로고
    • Biomechanical testing of the LCP - How can stability in locked internal fixators be controlled?
    • Stoffel K, Dieter U, Stachowiak G, Gachter A, Kuster MS. Biomechanical testing of the LCP - how can stability in locked internal fixators be controlled? Injury 2003;34 Suppl 2:B11-19.
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Stoffel, K.1    Dieter, U.2    Stachowiak, G.3    Gachter, A.4    Kuster, M.S.5
  • 22
    • 58649101626 scopus 로고    scopus 로고
    • Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis
    • Bristol, Avon
    • Fitzpatrick DC, Doornink J, Madey SM Bottlang M. Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis. Clin Biomech (Bristol, Avon) 2009;24:203-209.
    • (2009) Clin Biomech , vol.24 , pp. 203-209
    • Fitzpatrick, D.C.1    Doornink, J.2    Madey, S.M.3    Bottlang, M.4
  • 23
    • 37549053244 scopus 로고    scopus 로고
    • Complications of volar plating of distal radius fractures
    • Rampoldi M, Marsico S. Complications of volar plating of distal radius fractures. Acta Orthop Belg 2007;73:714-719.
    • (2007) Acta Orthop Belg , vol.73 , pp. 714-719
    • Rampoldi, M.1    Marsico, S.2
  • 24
    • 34248229716 scopus 로고    scopus 로고
    • Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
    • DOI 10.1097/BOT.0b013e318059b993, PII 0000513120070500000005
    • Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007;21:316-322. (Pubitemid 46718027)
    • (2007) Journal of Orthopaedic Trauma , vol.21 , Issue.5 , pp. 316-322
    • Arora, R.1    Lutz, M.2    Hennerbichler, A.3    Krappinger, D.4    Espen, D.5    Gabl, M.6
  • 26
    • 68049097129 scopus 로고    scopus 로고
    • Delayed rupture of extensor digitorum communis tendon following volar plating of distal radius fracture
    • Hattori Y, Doi K, Sakamoto S, Yukata K. Delayed rupture of extensor digitorum communis tendon following volar plating of distal radius fracture. Hand Surg 2008;13:183-185.
    • (2008) Hand Surg , vol.13 , pp. 183-185
    • Hattori, Y.1    Doi, K.2    Sakamoto, S.3    Yukata, K.4
  • 27
    • 47649088109 scopus 로고    scopus 로고
    • Volar Approach to Distal Radius Fractures
    • DOI 10.1016/j.jhsa.2008.04.018, PII S0363502308003912
    • Protopsaltis TS, Ruch DS. Volar approach to distal radius fractures. J Hand Surg 2008;33A:958-965. (Pubitemid 352020475)
    • (2008) Journal of Hand Surgery , vol.33 , Issue.6 , pp. 958-965
    • Protopsaltis, T.S.1    Ruch, D.S.2
  • 28
    • 0142148000 scopus 로고    scopus 로고
    • Bone Remodeling at the Endocortical Surface of the Human Femoral Neck: A Mechanism for Regional Cortical Thinning in Cases of Hip Fracture
    • DOI 10.1359/jbmr.2003.18.10.1775
    • Power J, Loveridge N, Lyon A, Rushton N, Parker M, Reeve J. Bone remodeling at the endocortical surface of the human femoral neck: a mechanism for regional cortical thinning in cases of hip fracture. J Bone Miner Res 2003;18:1775-1780. (Pubitemid 37322554)
    • (2003) Journal of Bone and Mineral Research , vol.18 , Issue.10 , pp. 1775-1780
    • Power, J.1    Loveridge, N.2    Lyon, A.3    Rushton, N.4    Parker, M.5    Reeve, J.6
  • 30
    • 0030131155 scopus 로고    scopus 로고
    • Mechanical validation of whole bone composite femur models
    • DOI 10.1016/0021-9290(95)00084-4
    • Cristofolini L, Viceconti M, Cappello A, Toni A. Mechanical validation of whole bone composite femur models. J Biomech 1996;29:525-535. (Pubitemid 26065734)
    • (1996) Journal of Biomechanics , vol.29 , Issue.4 , pp. 525-535
    • Cristofolini, L.1    Viceconti, M.2    Cappello, A.3    Toni, A.4
  • 31
    • 0034922981 scopus 로고    scopus 로고
    • Structural properties of a new design of composite replicate femurs and tibias
    • DOI 10.1016/S0021-9290(01)00015-X, PII S002192900100015X
    • Heiner AD, Brown TD. Structural properties of a new design of composite replicate femurs and tibias. J Biomech 2001;34:773-781. (Pubitemid 32674356)
    • (2001) Journal of Biomechanics , vol.34 , Issue.6 , pp. 773-781
    • Heiner, A.D.1    Brown, T.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.