메뉴 건너뛰기




Volumn 36, Issue 6, 2012, Pages 1450-1459

Variable velocity encoding in a three-dimensional, three-directional phase contrast sequence: Evaluation in phantom and volunteers

Author keywords

blood flow visualization; flow MRI; phase contrast magnetic resonance imaging; velocity encoding; velocity mapping

Indexed keywords

ADULT; ARTICLE; ASCENDING AORTA; BLOOD FLOW VELOCITY; CONTROLLED STUDY; DIASTOLE; FEMALE; HUMAN; HUMAN EXPERIMENT; LINEAR SYSTEM; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; THREE DIMENSIONAL THREE DIRECTIONAL PHASE CONTRAST SEQUENCE;

EID: 84869381468     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23778     Document Type: Article
Times cited : (29)

References (28)
  • 1
    • 34548598651 scopus 로고    scopus 로고
    • Flow measurement by magnetic resonance: A unique asset worth optimising
    • Kilner PJ, Gatehouse PD, Firmin DN,. Flow measurement by magnetic resonance: a unique asset worth optimising. J Cardiovasc Magn Reson 2007; 9: 723-728.
    • (2007) J Cardiovasc Magn Reson , vol.9 , pp. 723-728
    • Kilner, P.J.1    Gatehouse, P.D.2    Firmin, D.N.3
  • 2
    • 0032915991 scopus 로고    scopus 로고
    • Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI
    • Wigstrom L, Ebbers T, Fyrenius A, et al. Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI. Magn Reson Med 1999; 41: 793-799.
    • (1999) Magn Reson Med , vol.41 , pp. 793-799
    • Wigstrom, L.1    Ebbers, T.2    Fyrenius, A.3
  • 3
    • 79953304124 scopus 로고    scopus 로고
    • Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
    • Markl M, Kilner PJ, Ebbers T,. Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2011; 13: 7.
    • (2011) J Cardiovasc Magn Reson , vol.13 , pp. 7
    • Markl, M.1    Kilner, P.J.2    Ebbers, T.3
  • 5
    • 12244274310 scopus 로고    scopus 로고
    • Time-resolved three-dimensional phase-contrast MRI
    • Markl M, Chan FP, Alley MT, et al. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging 2003; 17: 499-506.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 499-506
    • Markl, M.1    Chan, F.P.2    Alley, M.T.3
  • 6
    • 0031830533 scopus 로고    scopus 로고
    • Visualizing blood flow patterns using streamlines, arrows, and particle paths
    • Buonocore MH,. Visualizing blood flow patterns using streamlines, arrows, and particle paths. Magn Reson Med 1998; 40: 210-226.
    • (1998) Magn Reson Med , vol.40 , pp. 210-226
    • Buonocore, M.H.1
  • 8
    • 0026834645 scopus 로고
    • Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging
    • Napel S, Lee DH, Frayne R, Rutt BK,. Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging. J Magn Reson Imaging 1992; 2: 143-153.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 143-153
    • Napel, S.1    Lee, D.H.2    Frayne, R.3    Rutt, B.K.4
  • 9
    • 0035028867 scopus 로고    scopus 로고
    • Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping
    • Kozerke S, Hasenkam JM, Pedersen EM, Boesiger P,. Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping. J Magn Reson Imaging 2001; 13: 690-698.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 690-698
    • Kozerke, S.1    Hasenkam, J.M.2    Pedersen, E.M.3    Boesiger, P.4
  • 10
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts and implementation
    • Lotz J, Meier C, Leppert A, Galanski M,. Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 2002; 22: 651-671.
    • (2002) Radiographics , vol.22 , pp. 651-671
    • Lotz, J.1    Meier, C.2    Leppert, A.3    Galanski, M.4
  • 12
    • 0028854765 scopus 로고
    • Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio
    • Lee AT, Pike GB, Pelc NJ,. Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio. Magn Reson Med 1995; 33: 122-126.
    • (1995) Magn Reson Med , vol.33 , pp. 122-126
    • Lee, A.T.1    Pike, G.B.2    Pelc, N.J.3
  • 13
    • 75749111626 scopus 로고    scopus 로고
    • Improved SNR in phase contrast velocimetry with five-point balanced flow encoding
    • Johnson KM, Markl M,. Improved SNR in phase contrast velocimetry with five-point balanced flow encoding. Magn Reson Med 2010; 63: 349-355.
    • (2010) Magn Reson Med , vol.63 , pp. 349-355
    • Johnson, K.M.1    Markl, M.2
  • 15
    • 2942715055 scopus 로고    scopus 로고
    • Arterial MR imaging phase-contrast flow measurement: Improvements with varying velocity sensitivity during cardiac cycle
    • Ringgaard S, Oyre SA, Pedersen EM,. Arterial MR imaging phase-contrast flow measurement: improvements with varying velocity sensitivity during cardiac cycle. Radiology 2004; 232: 289-294.
    • (2004) Radiology , vol.232 , pp. 289-294
    • Ringgaard, S.1    Oyre, S.A.2    Pedersen, E.M.3
  • 16
    • 0028055088 scopus 로고
    • MR angiography of the pelvis with variable velocity encoding and a phased-array coil
    • Swan JS, Grist TM, Weber DM, Sproat IA, Wojtowycz MM,. MR angiography of the pelvis with variable velocity encoding and a phased-array coil. Radiology 1994; 190: 363-369.
    • (1994) Radiology , vol.190 , pp. 363-369
    • Swan, J.S.1    Grist, T.M.2    Weber, D.M.3    Sproat, I.A.4    Wojtowycz, M.M.5
  • 17
    • 0027302493 scopus 로고
    • Blood flow measurement using variable velocity encoding in the RR interval
    • Buonocore MH,. Blood flow measurement using variable velocity encoding in the RR interval. Magn Reson Med 1993; 29: 790-795.
    • (1993) Magn Reson Med , vol.29 , pp. 790-795
    • Buonocore, M.H.1
  • 18
    • 84857015934 scopus 로고    scopus 로고
    • Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: Head to head comparison and validation at 1.5 T and 3 T
    • Carlsson M, Toger J, Kanski M, et al. Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T. J Cardiovasc Magn Reson 2011; 13: 55.
    • (2011) J Cardiovasc Magn Reson , vol.13 , pp. 55
    • Carlsson, M.1    Toger, J.2    Kanski, M.3
  • 20
  • 21
    • 66149091582 scopus 로고    scopus 로고
    • Referenceless phase velocity mapping using balanced SSFP
    • Nielsen JF, Nayak KS,. Referenceless phase velocity mapping using balanced SSFP. Magn Reson Med 2009; 61: 1096-1102.
    • (2009) Magn Reson Med , vol.61 , pp. 1096-1102
    • Nielsen, J.F.1    Nayak, K.S.2
  • 22
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO,. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 2007; 26: 375-385.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 375-385
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3    Reiser, M.F.4    Schoenberg, S.O.5
  • 23
    • 70349613200 scopus 로고    scopus 로고
    • Reliable two-dimensional phase unwrapping method using region growing and local linear estimation
    • Zhou K, Zaitsev M, Bao S,. Reliable two-dimensional phase unwrapping method using region growing and local linear estimation. Magn Reson Med 2009; 62: 1085-1090.
    • (2009) Magn Reson Med , vol.62 , pp. 1085-1090
    • Zhou, K.1    Zaitsev, M.2    Bao, S.3
  • 25
    • 79958782233 scopus 로고    scopus 로고
    • Sequence optimization to reduce velocity offsets in cardiovascular magnetic resonance volume flow quantification-a multi-vendor study
    • Rolf MP, Hofman MB, Gatehouse PD, et al. Sequence optimization to reduce velocity offsets in cardiovascular magnetic resonance volume flow quantification-a multi-vendor study. J Cardiovasc Magn Reson 2011; 13: 18.
    • (2011) J Cardiovasc Magn Reson , vol.13 , pp. 18
    • Rolf, M.P.1    Hofman, M.B.2    Gatehouse, P.D.3
  • 26
    • 34250697428 scopus 로고    scopus 로고
    • Baseline correction of phase contrast images improves quantification of blood flow in the great vessels
    • Chernobelsky A, Shubayev O, Comeau CR, Wolff SD,. Baseline correction of phase contrast images improves quantification of blood flow in the great vessels. J Cardiovasc Magn Reson 2007; 9: 681-685.
    • (2007) J Cardiovasc Magn Reson , vol.9 , pp. 681-685
    • Chernobelsky, A.1    Shubayev, O.2    Comeau, C.R.3    Wolff, S.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.