메뉴 건너뛰기




Volumn 3, Issue 11, 2012, Pages 2784-2793

Integration of optical components on-chip for scattering and fluorescence detection in an optofluidic device

Author keywords

[No Author keywords available]

Indexed keywords

PHOTOEXCITATION;

EID: 84869109451     PISSN: None     EISSN: 21567085     Source Type: Journal    
DOI: 10.1364/BOE.3.002784     Document Type: Article
Times cited : (28)

References (34)
  • 1
    • 82555162620 scopus 로고    scopus 로고
    • Emerging technologies for point-of-care CD4 T-lymphocyte counting
    • D. S. Boyle, K. R. Hawkins, M. S. Steele, M. Singhal, and X. Cheng, "Emerging technologies for point-of-care CD4 T-lymphocyte counting, " Trends Biotechnol. 30(1), 45-54 (2012).
    • (2012) Trends Biotechnol. , vol.30 , Issue.1 , pp. 45-54
    • Boyle, D.S.1    Hawkins, K.R.2    Steele, M.S.3    Singhal, M.4    Cheng, X.5
  • 2
    • 79956101040 scopus 로고    scopus 로고
    • Microfluidic whole-blood immunoassays
    • H. Jiang, X. Weng, and D. Q. Li, "Microfluidic whole-blood immunoassays, " Microfluid. Nanofluid. 10(5), 941-964 (2011).
    • (2011) Microfluid. Nanofluid , vol.10 , Issue.5 , pp. 941-964
    • Jiang, H.1    Weng, X.2    Li, D.Q.3
  • 3
    • 77954955369 scopus 로고    scopus 로고
    • A niche for microfluidics in portable hematology analyzers
    • D. Heikali and D. Di Carlo, "A niche for microfluidics in portable hematology analyzers, " J. Assoc. Lab. Autom. 15(4), 319-328 (2010).
    • (2010) J. Assoc. Lab. Autom. , vol.15 , Issue.4 , pp. 319-328
    • Heikali, D.1    Di Carlo, D.2
  • 4
    • 77955618032 scopus 로고    scopus 로고
    • Microfluidic platforms for single-cell analysis
    • R. N. Zare and S. Kim, "Microfluidic platforms for single-cell analysis, " Annu. Rev. Biomed. Eng. 12(1), 187-201 (2010).
    • (2010) Annu. Rev. Biomed. Eng. , vol.12 , Issue.1 , pp. 187-201
    • Zare, R.N.1    Kim, S.2
  • 5
    • 76849096270 scopus 로고    scopus 로고
    • Nano/Microfluidics for diagnosis of infectious diseases in developing countries
    • W. G. Lee, Y.-G. Kim, B. G. Chung, U. Demirci, and A. Khademhosseini, "Nano/Microfluidics for diagnosis of infectious diseases in developing countries, " Adv. Drug Deliv. Rev. 62(4-5), 449-457 (2010).
    • (2010) Adv. Drug Deliv. Rev. , vol.62 , Issue.4-5 , pp. 449-457
    • Lee, W.G.1    Kim, Y.-G.2    Chung, B.G.3    Demirci, U.4    Khademhosseini, A.5
  • 6
    • 78149391194 scopus 로고    scopus 로고
    • Simultaneous counting of two subsets of leukocytes using fluorescent silica nanoparticles in a sheathless microchip flow cytometer
    • H. Yun, H. Bang, J. Min, C. Chung, J. K. Chang, and D.-C. Han, "Simultaneous counting of two subsets of leukocytes using fluorescent silica nanoparticles in a sheathless microchip flow cytometer, " Lab Chip 10(23), 3243-3254 (2010).
    • (2010) Lab Chip , vol.10 , Issue.23 , pp. 3243-3254
    • Yun, H.1    Bang, H.2    Min, J.3    Chung, C.4    Chang, J.K.5    Han, D.-C.6
  • 7
    • 70350247721 scopus 로고    scopus 로고
    • Rapid on-chip flow cytometric detection of Listeria monocytogenes in milk
    • M. Ikeda, N. Yamaguchi, and M. Nasu, "Rapid on-chip flow cytometric detection of Listeria monocytogenes in milk, " J. Health Sci. 55(5), 851-856 (2009).
    • (2009) J. Health Sci. , vol.55 , Issue.5 , pp. 851-856
    • Ikeda, M.1    Yamaguchi, N.2    Nasu, M.3
  • 8
    • 77955324887 scopus 로고    scopus 로고
    • Micro flow cytometry chip device integrated with tunable microlens for ciculating tumor cells detection and counting applications
    • S. K. Hsiung, S. R. Lin, and C. H. Lin, "Micro flow cytometry chip device integrated with tunable microlens for ciculating tumor cells detection and counting applications, " Jpn. J. Appl. Phys. 49(6), 060218 (2010).
    • (2010) Jpn. J. Appl. Phys. , vol.49 , Issue.6 , pp. 060218
    • Hsiung, S.K.1    Lin, S.R.2    Lin, C.H.3
  • 10
    • 37549007566 scopus 로고    scopus 로고
    • Recent advances in miniaturized microfluidic flow cytometry for clinical use
    • T. D. Chung and H. C. Kim, "Recent advances in miniaturized microfluidic flow cytometry for clinical use, " Electrophoresis 28(24), 4511-4520 (2007).
    • (2007) Electrophoresis , vol.28 , Issue.24 , pp. 4511-4520
    • Chung, T.D.1    Kim, H.C.2
  • 11
    • 23844499837 scopus 로고    scopus 로고
    • Microfluidics for flow cytometric analysis of cells and particles
    • D. Huh, W. Gu, Y. Kamotani, J. B. Grotberg, and S. Takayama, "Microfluidics for flow cytometric analysis of cells and particles, " Physiol. Meas. 26(3), R73-R98 (2005).
    • (2005) Physiol. Meas. , vol.26 , Issue.3
    • Huh, D.1    Gu, W.2    Kamotani, Y.3    Grotberg, J.B.4    Takayama, S.5
  • 12
    • 84868013420 scopus 로고    scopus 로고
    • Fabrication and performance of a photonic-microfluidic integrated device
    • B. R. Watts, T. Kowpak, Z. Zhang, C. Q. Xu, S. Zhu, X. Cao, and M. Lin, "Fabrication and performance of a photonic-microfluidic integrated device, " Micromachines 3(1), 62-77 (2012).
    • (2012) Micromachines , vol.3 , Issue.1 , pp. 62-77
    • Watts, B.R.1    Kowpak, T.2    Zhang, Z.3    Xu, C.Q.4    Zhu, S.5    Cao, X.6    Lin, M.7
  • 13
    • 79957782416 scopus 로고    scopus 로고
    • Formation and characterization of an ideal excitation beam geometry in an optofluidic device
    • B. R. Watts, T. Kowpak, Z. Zhang, C. Q. Xu, and S. Zhu, "Formation and characterization of an ideal excitation beam geometry in an optofluidic device, " Biomed. Opt. Express 1(3), 848-860 (2010).
    • (2010) Biomed. Opt. Express , vol.1 , Issue.3 , pp. 848-860
    • Watts, B.R.1    Kowpak, T.2    Zhang, Z.3    Xu, C.Q.4    Zhu, S.5
  • 14
    • 84855278190 scopus 로고    scopus 로고
    • Sealing SU-8 microfluidic channels using PDMS
    • Z. Zhang, P. Zhao, G. Xiao, B. R. Watts, and C. Q. Xu, "Sealing SU-8 microfluidic channels using PDMS, " Biomicrofluidics 5(4), 046503 (2011).
    • (2011) Biomicrofluidics , vol.5 , Issue.4 , pp. 046503
    • Zhang, Z.1    Zhao, P.2    Xiao, G.3    Watts, B.R.4    Xu, C.Q.5
  • 15
    • 45249114510 scopus 로고    scopus 로고
    • Scattering-based cyotmetric detection using integrated arrayed waveguides with microfluidics
    • C. H. Chen, F. Tsai, V. Lien, N. Justis, and Y.-H. Lo, "Scattering-based cyotmetric detection using integrated arrayed waveguides with microfluidics, " IEEE Photon. Technol. Lett. 19(6), 441-443 (2007).
    • (2007) IEEE Photon. Technol. Lett. , vol.19 , Issue.6 , pp. 441-443
    • Chen, C.H.1    Tsai, F.2    Lien, V.3    Justis, N.4    Lo, Y.-H.5
  • 16
    • 29144457612 scopus 로고    scopus 로고
    • High-sensitivity cytometric detection using fluidic-photonic integrated circuits with array waveguides
    • V. Lien, K. Zhao, Y. Berdichevsky, and Y.-H. Lo, "High-sensitivity cytometric detection using fluidic-photonic integrated circuits with array waveguides, " IEEE J. Sel. Top. Quantum Electron. 11(4), 827-834 (2005).
    • (2005) IEEE J. Sel. Top. Quantum Electron. , vol.11 , Issue.4 , pp. 827-834
    • Lien, V.1    Zhao, K.2    Berdichevsky, Y.3    Lo, Y.-H.4
  • 17
    • 80053450007 scopus 로고    scopus 로고
    • Two-parameter angular light scatter collection for microfluidic flow cytometry by unique waveguide structures
    • J. Godin and Y.-H. Lo, "Two-parameter angular light scatter collection for microfluidic flow cytometry by unique waveguide structures, " Biomed. Opt. Express 1(5), 1472-1479 (2010).
    • (2010) Biomed. Opt. Express , vol.1 , Issue.5 , pp. 1472-1479
    • Godin, J.1    Lo, Y.-H.2
  • 19
    • 79955976623 scopus 로고    scopus 로고
    • Miniaturized flow cytometer with 3D hydrodynamic particle focusing and integrated optical elements applying silicon photodiodes
    • M. Rosenauer, W. Buchegger, I. Finoulst, P. Verhaert, and M. Vellekoop, "Miniaturized flow cytometer with 3D hydrodynamic particle focusing and integrated optical elements applying silicon photodiodes, " Microfluid. Nanofluid. 10(4), 761-771 (2011).
    • (2011) Microfluid. Nanofluid , vol.10 , Issue.4 , pp. 761-771
    • Rosenauer, M.1    Buchegger, W.2    Finoulst, I.3    Verhaert, P.4    Vellekoop, M.5
  • 20
    • 82555202745 scopus 로고    scopus 로고
    • Simultaneous high speed optical and impedance analysis of single particles with a microfluidic cytometer
    • D. Barat, D. Spencer, G. Benazzi, M. C. Mowlem, and H. Morgan, "Simultaneous high speed optical and impedance analysis of single particles with a microfluidic cytometer, " Lab Chip 12(1), 118-126 (2011).
    • (2011) Lab Chip , vol.12 , Issue.1 , pp. 118-126
    • Barat, D.1    Spencer, D.2    Benazzi, G.3    Mowlem, M.C.4    Morgan, H.5
  • 22
    • 77954000500 scopus 로고    scopus 로고
    • Fabrication of photonic/microfluidic integrated devices using an epoxy photoresist
    • T. Kowpak, B. R. Watts, Z. Zhang, S. Zhu, and C. Q. Xu, "Fabrication of photonic/microfluidic integrated devices using an epoxy photoresist, " Macromol. Mater. Eng. 295(6), 559-565 (2010).
    • (2010) Macromol. Mater. Eng. , vol.295 , Issue.6 , pp. 559-565
    • Kowpak, T.1    Watts, B.R.2    Zhang, Z.3    Zhu, S.4    Xu, C.Q.5
  • 24
    • 80053446269 scopus 로고    scopus 로고
    • Optofluidic characterization of marine algae using a microflow cytometer
    • N. Hashemi, J. S. Erickson, J. P. Golden, and F. S. Ligler, "Optofluidic characterization of marine algae using a microflow cytometer, " Biomicrofluidics 5(3), 032009 (2011).
    • (2011) Biomicrofluidics , vol.5 , Issue.3 , pp. 032009
    • Hashemi, N.1    Erickson, J.S.2    Golden, J.P.3    Ligler, F.S.4
  • 25
    • 62649119668 scopus 로고    scopus 로고
    • Microfluidic structures for flow cytometric analysis of hydrodynamically focussed blood cells fabricated by ultraprecision micromachining
    • A. Kummrow, J. Theisen, M. Frankowski, A. Tuchscheerer, H. Yildirim, K. Brattke, M. Schmidt, and J. Neukammer, "Microfluidic structures for flow cytometric analysis of hydrodynamically focussed blood cells fabricated by ultraprecision micromachining, " Lab Chip 9(7), 972-981 (2009).
    • (2009) Lab Chip , vol.9 , Issue.7 , pp. 972-981
    • Kummrow, A.1    Theisen, J.2    Frankowski, M.3    Tuchscheerer, A.4    Yildirim, H.5    Brattke, K.6    Schmidt, M.7    Neukammer, J.8
  • 27
    • 84879319706 scopus 로고    scopus 로고
    • A high performance interconnect for PDMS microfluidic devices
    • (to be published)
    • C. Mu, Z. Zhang, M. Lin, X. Cao, B. R. Watts, and C. Q. Xu, "A high performance interconnect for PDMS microfluidic devices, " Sens. Actuators (to be published).
    • Sens. Actuators
    • Mu, C.1    Zhang, Z.2    Lin, M.3    Cao, X.4    Watts, B.R.5    Xu, C.Q.6
  • 28
    • 66149096113 scopus 로고    scopus 로고
    • Single-layer planar on-chip flow cytometer using microfluidic drifting based three-dimensional (3D) hydrodynamic focusing
    • X. Mao, S. C. S. Lin, C. Dong, and T. J. Huang, "Single-layer planar on-chip flow cytometer using microfluidic drifting based three-dimensional (3D) hydrodynamic focusing, " Lab Chip 9(11), 1583-1589 (2009).
    • (2009) Lab Chip , vol.9 , Issue.11 , pp. 1583-1589
    • Mao, X.1    Lin, S.C.S.2    Dong, C.3    Huang, T.J.4
  • 29
    • 84855923896 scopus 로고    scopus 로고
    • Microflow cytometer incorporating sequential micro-weir structure for three-dimensional focusing
    • H. C. Lee, H. H. Hou, R. J. Yang, C. H. Lin, and L. M. Fu, "Microflow cytometer incorporating sequential micro-weir structure for three-dimensional focusing, " Microfluid. Nanofluid. 11(4), 469-478 (2011).
    • (2011) Microfluid. Nanofluid. , vol.11 , Issue.4 , pp. 469-478
    • Lee, H.C.1    Hou, H.H.2    Yang, R.J.3    Lin, C.H.4    Fu, L.M.5
  • 31
    • 0035499699 scopus 로고    scopus 로고
    • Flow cytometry of Escherichia coli on microfluidic devices
    • M. A. McClain, C. T. Culbertson, S. C. Jacobson, and J. M. Ramsey, "Flow cytometry of Escherichia coli on microfluidic devices, " Anal. Chem. 73(21), 5334-5338 (2001).
    • (2001) Anal. Chem. , vol.73 , Issue.21 , pp. 5334-5338
    • McClain, M.A.1    Culbertson, C.T.2    Jacobson, S.C.3    Ramsey, J.M.4
  • 32
    • 80053446269 scopus 로고    scopus 로고
    • Optofluidic characterization of marine algai using a microflow cytometer
    • N. Hashemi, J. S. Erickson, J. P. Golden, and F. S. Ligler, "Optofluidic characterization of marine algai using a microflow cytometer, " Biomicrofluidics 5(3), 032009 (2011).
    • (2011) Biomicrofluidics , vol.5 , Issue.3 , pp. 032009
    • Hashemi, N.1    Erickson, J.S.2    Golden, J.P.3    Ligler, F.S.4
  • 33
    • 84879304235 scopus 로고    scopus 로고
    • Application Note
    • A. Cytometry, "VenturiOne cell cycle analysis, " Application Note, http://www.appliedcytometry.com/pdfs/VenturiOne_DNA_Cell_Cycle_Application_Note_low_res.pdf.
    • VenturiOne cell cycle analysis
    • Cytometry, A.1
  • 34
    • 63749098176 scopus 로고    scopus 로고
    • Optical microflow cytometer for particle counting, sizing and fluorescence detection
    • H. T. Chen and Y. N. Wang, "Optical microflow cytometer for particle counting, sizing and fluorescence detection, " Microfluid. Nanofluid. 6(4), 529-537 (2009).
    • (2009) Microfluid. Nanofluid. , vol.6 , Issue.4 , pp. 529-537
    • Chen, H.T.1    Wang, Y.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.