1
-
-
0036581711
-
Dissolution of tungsten coils does not produce systemic toxicity, but leads to elevated levels of tungsten in the serum and recanalization of the previously occluded vessel
-
DOI 10.1017/S1047951102000513
-
Peuster M, Fink C, von Schnakenburg C, Hausdorf G. Dissolution of tungsten coils does not produce systemic toxicity, but leads to elevated levels of tungsten in the serum and recanalization of the previously occluded vessel. Cardiol Young 2002;12:229-235. (Pubitemid 41238835)
-
(2002)
Cardiology in the Young
, vol.12
, Issue.3
, pp. 229-235
-
-
Peuster, M.1
Fink, C.2
Von Schnakenburg, C.3
Hausdorf, G.4
-
2
-
-
0031465283
-
Characteristics of metals used in implants
-
Gotman I. Characteristics of metals used in implants. J Endourol 1997;11:383-389. (Pubitemid 28021408)
-
(1997)
Journal of Endourology
, vol.11
, Issue.6
, pp. 383-389
-
-
Gotman, I.1
-
3
-
-
0034893299
-
Redilation of endovascular stents in congenital heart disease: Factors implicated in the development of restenosis and neointimal proliferation
-
DOI 10.1016/S0735-1097(01)01406-1, PII S0735109701014061
-
McMahon CJ, El-Said HG, Grifka RG, Fraley JK, Nihill MR, Mullins CE. Redilation of endovascular stents in congenital heart disease: Factors implicated in the development of restenosis and neointimal proliferation. J Am Coll Cardiol 2001;38:521-526. (Pubitemid 32721783)
-
(2001)
Journal of the American College of Cardiology
, vol.38
, Issue.2
, pp. 521-526
-
-
McMahon, C.J.1
El-Said, H.G.2
Grifka, R.G.3
Fraley J.Kennard4
Nihill, M.R.5
Mullins, C.E.6
-
4
-
-
0043169537
-
The efficacy and safety of stent redilatation in congenital heart disease
-
Duke C, Rosenthal E, Qureshi SA. The efficacy and safety of stent redilatation in congenital heart disease. Heart 2003;89:905-912. (Pubitemid 36920818)
-
(2003)
Heart
, vol.89
, Issue.8
, pp. 905-912
-
-
Duke, C.1
Rosenthal, E.2
Qureshi, S.A.3
-
5
-
-
34147117347
-
Analysis of 36 reported cases of late thrombosis in drug-eluting stents placed in coronary arteries
-
DOI 10.1016/j.amjcard.2006.12.025, PII S0002914907000793
-
Artang R, Dieter RS. Analysis of 36 reported cases of late thrombosis in drug-eluting stents placed in coronary arteries. Am J Cardiol 2007;99:1039-1043. (Pubitemid 46560471)
-
(2007)
American Journal of Cardiology
, vol.99
, Issue.8
, pp. 1039-1043
-
-
Artang, R.1
Dieter, R.S.2
-
7
-
-
77953732519
-
Bioabsorbable coronary stents-Are these the next big thing in coronary angioplasty?
-
Balla S, Aggarwal K, Nistala R. Bioabsorbable coronary stents-Are these the next big thing in coronary angioplasty? Recent Pat Cardiovasc Drug Discov 2010;5:86-90.
-
(2010)
Recent Pat Cardiovasc Drug Discov
, vol.5
, pp. 86-90
-
-
Balla, S.1
Aggarwal, K.2
Nistala, R.3
-
8
-
-
33646016035
-
Biodegradable stents: They do their job and disappear
-
Waksman R. Biodegradable stents: They do their job and disappear. J Invasive Cardiol 2006;18:70-74.
-
(2006)
J Invasive Cardiol
, vol.18
, pp. 70-74
-
-
Waksman, R.1
-
9
-
-
0034768824
-
Dissolution of tungsten coils leads to device failure after transcatheter embolisation of pathologic vessels [3]
-
Peuster M, Kaese V, Wuensch G, Wuebbolt P, Niemeyer M, Boekenkamp R, Fink C, Haferkamp H, Hausdorf G. Dissolution of tungsten coils leads to device failure after transcatheter embolisation of pathologic vessels. Heart 2001;85:703-704. (Pubitemid 32973473)
-
(2001)
Heart
, vol.85
, Issue.6
, pp. 703-704
-
-
Peuster, M.1
Kaese, V.2
Wuensch, G.3
Wuebbolt, P.4
Niemeyer, M.5
Boekenkamp, R.6
Fink, C.7
Haferkamp, H.8
Hausdorf, G.9
-
10
-
-
0037273578
-
Mechanisms of restenosis after coronary intervention: Difference between plain old balloon angioplasty and stenting
-
DOI 10.1016/S1054-8807(02)00135-7, PII S1054880702001357
-
Nakatani M, Takeyama Y, Shibata M, Yorozuya M, Suzuki H, Koba S, Katagiri T. Mechanisms of restenosis after coronary intervention: Difference between plain old balloon angioplasty and stenting. Cardiovasc Pathol 2003;12:40-48. (Pubitemid 36206511)
-
(2003)
Cardiovascular Pathology
, vol.12
, Issue.1
, pp. 40-48
-
-
Nakatani, M.1
Takeyama, Y.2
Shibata, M.3
Yorozuya, M.4
Suzuki, H.5
Koba, S.6
Katagiri, T.7
-
11
-
-
0036952287
-
Biodegradation of tungsten embolisation coils used in children
-
DOI 10.1007/s00247-002-0825-1
-
Kampmann C, Brzezinska R, Abidini M, Wenzel A, Wippermann CF, Habermehl P, Knuf M, Schumacher R. Biodegradation of tungsten embolisation coils used in children. Pediatr Radiol 2002;32:839-843. (Pubitemid 36097139)
-
(2002)
Pediatric Radiology
, vol.32
, Issue.12
, pp. 839-843
-
-
Kampmann, C.1
Brzezinska, R.2
Abidini, M.3
Wenzel, A.4
Wippermann, C.-F.5
Hebermehl, P.6
Knuf, M.7
Schumacher, R.8
-
12
-
-
0034778878
-
A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal - Results 6-18 months after implantation into New Zealand white rabbits
-
Peuster M, Wohlsein P, Brugmann M, Ehlerding M, Seidler K, Fink C, Brauer H, Fischer A, Hausdorf G. A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-Results 6-18 months after implantation into New Zealand white rabbits. Heart 2001;86:563-569. (Pubitemid 32999872)
-
(2001)
Heart
, vol.86
, Issue.5
, pp. 563-569
-
-
Peuster, M.1
Wohlsein, P.2
Brugmann, M.3
Ehlerding, M.4
Seidler, K.5
Fink, C.6
Brauer, H.7
Fischer, A.8
Hausdorf, G.9
-
13
-
-
9244220627
-
Drug-eluting bioabsorbable magnesium stent
-
DOI 10.1111/j.1540-8183.2004.04081.x
-
Di Mario C, Griffiths H, Goktekin O, Peeters N, Verbist J, Bosiers M, Deloose K, Heublein B, Rohde R, Kasese V, Ilsley C, Erbel R. Drug-eluting bioabsorbable magnesium stent. J Interv Cardiol 2004;17:391-395. (Pubitemid 39552594)
-
(2004)
Journal of Interventional Cardiology
, vol.17
, Issue.6
, pp. 391-395
-
-
Di Mario, C.1
Griffiths, H.2
Goktekin, O.3
Peeters, N.4
Verbist, J.5
Bosiers, M.6
Deloose, K.7
Heublein, B.8
Rohde, R.9
Kasese, V.10
Ilsley, C.11
Erbel, R.12
-
15
-
-
33747740694
-
Are resorbable implants about to become a reality?
-
DOI 10.1017/S1047951106000011, PII S1047951106000011
-
Peuster M, Beerbaum P, Bach FW, Hauser H. Are resorbable implants about to become a reality? Cardiol Young 2006;16:107-116. (Pubitemid 44269389)
-
(2006)
Cardiology in the Young
, vol.16
, Issue.2
, pp. 107-116
-
-
Peuster, M.1
Beerbaum, P.2
Bach, F.-W.3
Hauser, H.4
-
16
-
-
0038354711
-
Biocompatibility of corroding tungsten coils: In vitro assessment of degradation kinetics and cytotoxicity on human cells
-
DOI 10.1016/S0142-9612(03)00274-6
-
Peuster M, Fink C, von Schnakenburg C. Biocompatibility of corroding tungsten coils: In vitro assessment of degradation kinetics and cytotoxicity on human cells. Biomaterials 2003;24:4057-4061. (Pubitemid 36794408)
-
(2003)
Biomaterials
, vol.24
, Issue.22
, pp. 4057-4061
-
-
Peuster, M.1
Fink, C.2
Von Schnakenburg, C.3
-
17
-
-
0038486163
-
Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology?
-
Heublein B, Rohde R, Kaese V, Niemeyer M, Hartung W, Haverich A. Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology? Heart 2003;89:651-656. (Pubitemid 36606211)
-
(2003)
Heart
, vol.89
, Issue.6
, pp. 651-656
-
-
Heublein, B.1
Rohde, R.2
Kaese, V.3
Niemeyer, M.4
Hartung, W.5
Haverich, A.6
-
18
-
-
33745736221
-
Cartilage repair on magnesium scaffolds used as a subchondral bone replacement
-
DOI 10.1002/mawe.200600027
-
Witte F, Reifenrath J, Müller PP, Crostack H-A, Nellesen J, Bach FW, Bormann D, Rudert M. Cartilage repair on magnesium scaffolds used as a subchondral bone replacement. Mat.-wiss u Werkstofftech 2006;37:504-508. (Pubitemid 44012814)
-
(2006)
Materialwissenschaft und Werkstofftechnik
, vol.37
, Issue.6
, pp. 504-508
-
-
Witte, F.1
Reifenrath, J.2
Muller, P.P.3
Crostack, H.-A.4
Nellesen, J.5
Bach, F.W.6
Bormann, D.7
Rudert, M.8
-
19
-
-
27644597192
-
In vitro and in vivo corrosion measurements of magnesium alloys
-
DOI 10.1016/j.biomaterials.2005.07.037, PII S0142961205007088
-
Witte F, Fischer J, Nellesen J, Crostack HA, Kaese V, Pisch A, Beckmann F, Windhagen H. In vitro and in vivo corrosion measurements of magnesium alloys. Biomaterials 2006;27:1013-1018. (Pubitemid 41566693)
-
(2006)
Biomaterials
, vol.27
, Issue.7
, pp. 1013-1018
-
-
Witte, F.1
Fischer, J.2
Nellesen, J.3
Crostack, H.-A.4
Kaese, V.5
Pisch, A.6
Beckmann, F.7
Windhagen, H.8
-
20
-
-
28844455504
-
First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby
-
DOI 10.1002/ccd.20520
-
Zartner P, Cesnjevar R, Singer H, Weyand M. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby. Catheter Cardiovasc Interv 2005;66:590-594. (Pubitemid 41779033)
-
(2005)
Catheterization and Cardiovascular Interventions
, vol.66
, Issue.4
, pp. 590-594
-
-
Zartner, P.1
Cesnjevar, R.2
Singer, H.3
Weyand, M.4
-
21
-
-
0029761378
-
Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries
-
van der Giessen WJ, Lincoff AM, Schwartz RS, van Beusekom HM, Serruys PW, Holmes DR Jr, Ellis SG, Topol EJ. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation 1996;94:1690-1697. (Pubitemid 26320276)
-
(1996)
Circulation
, vol.94
, Issue.7
, pp. 1690-1697
-
-
Van Der Giessen, W.J.1
Lincoff, A.M.2
Schwartz, R.S.3
Van Beusekom, H.M.M.4
Serruys, P.W.5
Holmes Jr., D.R.6
Ellis, S.G.7
Topol, E.J.8
-
22
-
-
3242877692
-
Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent
-
DOI 10.1016/j.ehj.2004.06.010, PII S0195668X04003938
-
Vogt F, Stein A, Rettemeier G, Krott N, Hoffmann R, vom Dahl J, Bosserhoff AK, Michaeli W, Hanrath P, Weber C, Blindt R. Longterm assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent. Eur Heart J 2004;25:1330-1340. (Pubitemid 38998510)
-
(2004)
European Heart Journal
, vol.25
, Issue.15
, pp. 1330-1340
-
-
Vogt, F.1
Stein, A.2
Rettemeier, G.3
Krott, N.4
Hoffmann, R.5
Dahl, J.V.6
Bosserhoff, A.-K.7
Michaeli, W.8
Hanrath, P.9
Weber, C.10
Blindt, R.11
-
23
-
-
21544469971
-
Biocompatibility screening in cardiovascular implants
-
DOI 10.1007/s00392-005-0231-4
-
Sigler M, Paul T, Grabitz RG. Biocompatibility screening in cardiovascular implants. Z Kardiol 2005;94:383-391. (Pubitemid 40921966)
-
(2005)
Zeitschrift fur Kardiologie
, vol.94
, Issue.6
, pp. 383-391
-
-
Sigler, M.1
Paul, T.2
Grabitz, R.G.3
-
24
-
-
0007488634
-
Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans
-
Tamai H, Igaki K, Kyo E, Kosuga K, Kawashima A, Matsui S, Komori H, Tsuji T, Motohara S, Uehata H. Initial and 6-month results of biodegradable poly-L-lactic acid coronary stents in humans. Circulation 2000;102:399-404. (Pubitemid 30490677)
-
(2000)
Circulation
, vol.102
, Issue.4
, pp. 399-404
-
-
Tamai, H.1
Igaki, K.2
Kyo, E.3
Kosuga, K.4
Kawashima, A.5
Matsui, S.6
Komori, H.7
Tsuji, T.8
Motohara, S.9
Uehata, H.10
-
25
-
-
0037400574
-
Collapse pressures of biodegradable stents
-
DOI 10.1016/S0142-9612(02)00640-3
-
Venkatraman S, Poh TL, Vinalia T, Mak KH, Boey F. Collapse pressures of biodegradable stents. Biomaterials 2003;24:2105-2111. (Pubitemid 36298782)
-
(2003)
Biomaterials
, vol.24
, Issue.12
, pp. 2105-2111
-
-
Venkatraman, S.1
Poh, T.L.2
Vinalia, T.3
Mak, K.H.4
Boey, F.5
-
26
-
-
33744988409
-
Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
-
DOI 10.1016/j.biomaterials.2006.05.029, PII S0142961206004923
-
Peuster M, Hesse C, Schloo T, Fink C, Beerbaum P, von Schnakenburg C. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta. Biomaterials 2006;27:4955-4962. (Pubitemid 43866928)
-
(2006)
Biomaterials
, vol.27
, Issue.28
, pp. 4955-4962
-
-
Peuster, M.1
Hesse, C.2
Schloo, T.3
Fink, C.4
Beerbaum, P.5
Von Schnakenburg, C.6
-
27
-
-
59449109182
-
Iron homeostasis: Recently identified proteins provide insight into novel control mechanisms
-
Zhang AS, Enns CA. Iron homeostasis: Recently identified proteins provide insight into novel control mechanisms. J Biol Chem 2009;284:711-715.
-
(2009)
J Biol Chem
, vol.284
, pp. 711-715
-
-
Zhang, A.S.1
Enns, C.A.2
-
28
-
-
2042546096
-
Balancing acts: Molecular control of mammalian iron metabolism
-
DOI 10.1016/S0092-8674(04)00343-5, PII S0092867404003435
-
Hentze MW, Muckenthaler MU, Andrews NC. Balancing acts: Molecular control of mammalian iron metabolism. Cell 2004;117:285-297. (Pubitemid 38534536)
-
(2004)
Cell
, vol.117
, Issue.3
, pp. 285-297
-
-
Hentze, M.W.1
Muckenthaler, M.U.2
Andrews, N.C.3
-
29
-
-
57649090012
-
Degradation behaviour of metallic biomaterials for degradable stents
-
Hermawan H, Moravej M, Dubé D, Fiset M, Mantovani D. Degradation behaviour of metallic biomaterials for degradable stents. Adv Mater Res 15;15-17:113-118.
-
(2007)
Adv Mater Res
, vol.15-17
, pp. 113-118
-
-
Hermawan, H.1
Moravej, M.2
Dubé, D.3
Fiset, M.4
Mantovani, D.5
-
30
-
-
65549107313
-
Genetic lines differ in Toll-like receptor gene expression in spleens of chicks inoculated with Salmonella enterica serovar Enteritidis
-
Abasht B, Kaiser MG, van der Poel J, Lamont SJ. Genetic lines differ in Toll-like receptor gene expression in spleens of chicks inoculated with Salmonella enterica serovar Enteritidis. Poult Sci 2009;88:744-749.
-
(2009)
Poult Sci
, vol.88
, pp. 744-749
-
-
Abasht, B.1
Kaiser, M.G.2
Van Der Poel, J.3
Lamont, S.J.4
-
31
-
-
28844497993
-
Control of smooth muscle cell proliferation by ferrous iron
-
DOI 10.1016/j.biomaterials.2005.10.042, PII S0142961205010173
-
Mueller PP, May T, Perz A, Hauser H, Peuster M. Control of smooth muscle cell proliferation by ferrous iron. Biomaterials 2006;27:2193-2200. (Pubitemid 41774531)
-
(2006)
Biomaterials
, vol.27
, Issue.10
, pp. 2193-2200
-
-
Mueller, P.P.1
May, T.2
Perz, A.3
Hauser, H.4
Peuster, M.5
-
32
-
-
77649201086
-
Degradable metallic biomaterials: Design and development of Fe-Mn alloys for stents
-
Hermawan H, Dubé D, Mantovani D. Degradable metallic biomaterials: Design and development of Fe-Mn alloys for stents. J Biomed Mater Res A 2010;93:1-11.
-
(2010)
J Biomed Mater Res A
, vol.93
, pp. 1-11
-
-
Hermawan, H.1
Dubé, D.2
Mantovani, D.3
-
34
-
-
33749057310
-
Future devices: Bioabsorbable stents
-
Griffiths H, Peeters P, Verbist J, Bosiers M, Deloose K, Heublein B, Rohde R, Kasese V, Ilsley C, di Mario C. Future devices: Bioabsorbable stents. Br J Cardiol 2004;11:80-84.
-
(2004)
Br J Cardiol
, vol.11
, pp. 80-84
-
-
Griffiths, H.1
Peeters, P.2
Verbist, J.3
Bosiers, M.4
Deloose, K.5
Heublein, B.6
Rohde, R.7
Kasese, V.8
Ilsley, C.9
Di Mario, C.10
-
35
-
-
6444221460
-
Preclinical evaluation of drug-eluting stents for peripheral applications: Recommendations from an expert consensus group
-
DOI 10.1161/01.CIR.0000145164.85178.2E
-
Schwartz RS, Edelman ER, Carter A, Chronos NA, Rogers C, Robinson KA, Waksman R, Machan L, Weinberger J, Wilensky RL, Goode JL, Hottenstein OD, Zuckerman BD, Virmani R. Preclinical evaluation of drug-eluting stents for peripheral applications: Recommendations from an expert consensus group. Circulation 2004;110:2498-2505. (Pubitemid 39407359)
-
(2004)
Circulation
, vol.110
, Issue.16
, pp. 2498-2505
-
-
Schwartz, R.S.1
Edelman, E.R.2
Carter, A.3
Chronos, N.A.4
Rogers, C.5
Robinson, K.A.6
Waksman, R.7
Machan, L.8
Weinberger, J.9
Wilensky, R.L.10
Goode, J.L.11
Hottenstein, O.D.12
Zuckerman, B.D.13
Virmani, R.14
-
36
-
-
84907126089
-
Embedding in epoxy resins for ultrathin sectioning in electron microscopy
-
Richardson KC, Jarett L, Finke EH. Embedding in epoxy resins for ultrathin sectioning in electron microscopy. Stain Technol 1960;35:313-323.
-
(1960)
Stain Technol
, vol.35
, pp. 313-323
-
-
Richardson, K.C.1
Jarett, L.2
Finke, E.H.3
-
37
-
-
0038005018
-
DAVID: Database for annotation, visualization, and integrated discovery
-
Dennis G Jr, Sherman BT, Hosack DA, Yang J, Gao W, Lane HC, Lempicki RA. DAVID: Database for Annotation, Visualization, and Integrated Discovery. Genome Biol 2003;4:P3.
-
(2003)
Genome Biol
, vol.4
, pp. 3
-
-
Dennis Jr., G.1
Sherman, B.T.2
Hosack, D.A.3
Yang, J.4
Gao, W.5
Lane, H.C.6
Lempicki, R.A.7
-
38
-
-
3142756502
-
Open source clustering software
-
DOI 10.1093/bioinformatics/bth078
-
de Hoon MJ, Imoto S, Nolan J, Miyano S. Open source clustering software. Bioinformatics 2004;20:1453-1454. (Pubitemid 38931415)
-
(2004)
Bioinformatics
, vol.20
, Issue.9
, pp. 1453-1454
-
-
De Hoon, M.J.L.1
Imoto, S.2
Nolan, J.3
Miyano, S.4
-
39
-
-
77951698149
-
Hypoxia-inducible factor-1-dependent mechanisms of vascularization and vascular remodelling
-
Rey S, Semenza GL. Hypoxia-inducible factor-1-dependent mechanisms of vascularization and vascular remodelling. Cardiovasc Res 2010;86:236-242.
-
(2010)
Cardiovasc Res
, vol.86
, pp. 236-242
-
-
Rey, S.1
Semenza, G.L.2
-
40
-
-
27944442568
-
Angiogenesis: Update 2005
-
DOI 10.1111/j.1538-7836.2005.01361.x
-
Dvorak HF. Angiogenesis: Update 2005. J Thromb Haemost 2005;3:1835-1842. (Pubitemid 41716570)
-
(2005)
Journal of Thrombosis and Haemostasis
, vol.3
, Issue.8
, pp. 1835-1842
-
-
Dvorak, H.F.1
-
41
-
-
77954535213
-
Influence of Fe (II) and Fe (III) on the expression of genes related to cholesterol and fatty acid metabolism in human vascular smooth muscle cells
-
Drynda A, Hoehn R, Peuster M. Influence of Fe (II) and Fe (III) on the expression of genes related to cholesterol and fatty acid metabolism in human vascular smooth muscle cells. J Mater Sci Mater Med 2010;21:1655-1663.
-
(2010)
J Mater Sci Mater Med
, vol.21
, pp. 1655-1663
-
-
Drynda, A.1
Hoehn, R.2
Peuster, M.3
-
42
-
-
84857285894
-
Hypoxia differentially regulates arterial and venous smooth muscle cell proliferation via PDGFRbeta and VEGFR-2 expression
-
Chanakira A, Dutta R, Charboneau R, Barke R, Santilli SM, Roy S. Hypoxia differentially regulates arterial and venous smooth muscle cell proliferation via PDGFRbeta and VEGFR-2 expression. Am J Physiol Heart Circ Physiol 2012;302:H1173-H1184.
-
(2012)
Am J Physiol Heart Circ Physiol
, vol.302
-
-
Chanakira, A.1
Dutta, R.2
Charboneau, R.3
Barke, R.4
Santilli, S.M.5
Roy, S.6
-
43
-
-
82955250113
-
A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials
-
Pierson D, Edick J, Tauscher A, Pokorney E, Bowen P, Gelbaugh J, Stinson J, Getty H, Lee CH, Drelich J, Goldman J. A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials. J Biomed Mater Res Part B 2012;100B: 58-67.
-
(2012)
J Biomed Mater Res Part B
, vol.100 B
, pp. 58-67
-
-
Pierson, D.1
Edick, J.2
Tauscher, A.3
Pokorney, E.4
Bowen, P.5
Gelbaugh, J.6
Stinson, J.7
Getty, H.8
Lee, C.H.9
Drelich, J.10
Goldman, J.11
-
44
-
-
33744516940
-
Role of stent design and coatings on restenosis and thrombosis
-
DOI 10.1016/j.addr.2006.01.022, PII S0169409X06000263
-
Hara H, Nakamura M, Palmaz JC, Schwartz RS. Role of stent design and coatings on restenosis and thrombosis. Adv Drug Deliv Rev 2006;58:377-386. (Pubitemid 43816740)
-
(2006)
Advanced Drug Delivery Reviews
, vol.58
, Issue.3
, pp. 377-386
-
-
Hara, H.1
Nakamura, M.2
Palmaz, J.C.3
Schwartz, R.S.4
-
45
-
-
33747843457
-
The engineering of endovascular stent technology: A review
-
DOI 10.1177/153857440604000201
-
Whittaker DR, Fillinger MF. The engineering of endovascular stent technology: A review. Vasc Endovascular Surg 2006;40:85-94. (Pubitemid 44439942)
-
(2006)
Vascular and Endovascular Surgery
, vol.40
, Issue.2
, pp. 85-94
-
-
Whittaker, D.R.1
Fillinger, M.F.2
-
46
-
-
0036634198
-
Effect of endovascular stent strut geometry on vascular injury, myointimal hyperplasia, and restenosis
-
DOI 10.1067/mva.2002.122878
-
Sullivan TM, Ainsworth SD, Langan EM, Taylor S, Snyder B, Cull D, Youkey J, Laberge M. Effect of endovascular stent strut geometry on vascular injury, myointimal hyperplasia, and restenosis. J Vasc Surg 2002;36:143-149. (Pubitemid 41122903)
-
(2002)
Journal of Vascular Surgery
, vol.36
, Issue.1
, pp. 143-149
-
-
Sullivan, T.M.1
Ainsworth, S.D.2
Langan, E.M.3
Taylor, S.4
Snyder, B.5
Cull, D.6
Youkey, J.7
Laberge, M.8
-
47
-
-
56549115849
-
Development of degradable Fe-35Mn alloy for biomedical application
-
Hermawan H, Dubé D, Mantovani D. Development of degradable Fe-35Mn alloy for biomedical application. Adv Mater Res 2007;15-17:107-112.
-
(2007)
Adv Mater Res
, vol.15-17
, pp. 107-112
-
-
Hermawan, H.1
Dubé, D.2
Mantovani, D.3
-
48
-
-
77954684596
-
Fe-Mn alloys for metallic biodegradable stents: Degradation and cell viability studies
-
Hermawan H, Purnama A, Dubé D, Couet J, Mantovani D. Fe-Mn alloys for metallic biodegradable stents: Degradation and cell viability studies. Acta Biomaterialia 2010;6:1852-1860.
-
(2010)
Acta Biomaterialia
, vol.6
, pp. 1852-1860
-
-
Hermawan, H.1
Purnama, A.2
Dubé, D.3
Couet, J.4
Mantovani, D.5
-
49
-
-
0037292878
-
Granatsplitterverletzung unter dem klinischen bild einer thrombophlebitis
-
Gaber Y. [Grenade splinter injury simulating thrombophlebitis]. Vasa 2003;32:40-42. (Pubitemid 36286280)
-
(2003)
Vasa - Journal of Vascular Diseases
, vol.32
, Issue.1
, pp. 40-42
-
-
Gaber, Y.1
-
50
-
-
0042413424
-
Spontaneous extrusion of hand grenade fragments from the face 60 years after injury
-
Ghislain PD. Spontaneous extrusion of hand grenade fragments from the face 60 years after injury. JAMA 2003;290:1317-1318.
-
(2003)
JAMA
, vol.290
, pp. 1317-1318
-
-
Ghislain, P.D.1
-
52
-
-
0016793761
-
Wandering of foreign bodies. (Grenate fragment in the common bile duct causing jaundice)
-
Voigtlaender H. [Wandering of foreign bodies. (Grenate fragment in the common bile duct causing jaundice)]. Chirurg 1975;46:467-469.
-
(1975)
Chirurg
, vol.46
, pp. 467-469
-
-
Voigtlaender, H.1
-
53
-
-
32244444932
-
Pulmonary haemosiderosis in infants and children
-
DOI 10.1016/j.prrv.2005.11.003, PII S1526054205001168
-
Nuesslein TG, Teig N, Rieger CH. Pulmonary haemosiderosis in infants and children. Paediatr Respir Rev 2006;7:45-48. (Pubitemid 43210642)
-
(2006)
Paediatric Respiratory Reviews
, vol.7
, Issue.1
, pp. 45-48
-
-
Nuesslein, T.G.1
Teig, N.2
Rieger, C.H.L.3
-
54
-
-
34248994970
-
Diffuse alveolar hemorrhage syndromes in children
-
DOI 10.1097/MOP.0b013e3280dd8c4a, PII 0000848020070600000014
-
Susarla SC, Fan LL. Diffuse alveolar hemorrhage syndromes in children. Curr Opin Pediatr 2007;19:314-320. (Pubitemid 46788119)
-
(2007)
Current Opinion in Pediatrics
, vol.19
, Issue.3
, pp. 314-320
-
-
Susarla, S.C.1
Fan, L.L.2
-
55
-
-
0033623947
-
Sideroelastose der pulmonalgefasse nach schweissrauchexposition
-
DOI 10.1007/s002920050392
-
Verhoff MA, Muller KM. [Sideroelastosis of pulmonary vessels after welder dust exposure]. Pathologe 2000;21:229-233. (Pubitemid 30414675)
-
(2000)
Pathologe
, vol.21
, Issue.3
, pp. 229-233
-
-
Verhoff, M.A.1
Muller, K.-M.2
|