-
1
-
-
0037411338
-
Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr
-
M. Niinomi Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr Biomaterials 24 2003 2673 2683
-
(2003)
Biomaterials
, vol.24
, pp. 2673-2683
-
-
Niinomi, M.1
-
2
-
-
0037389297
-
Aging response of the Young's modulus and mechanical properties of Ti-29Nb-13Ta-4.6Zr for biomedical applications
-
Y.L. Hao, M. Niinomi, D. Kuroda, K. Fukunaga, R. Yang, and A. Suzuki Aging response of the Young's modulus and mechanical properties of Ti-29Nb-13Ta-4.6Zr for biomedical applications Metall. Mater. Trans. A 34 2003 1007 1013
-
(2003)
Metall. Mater. Trans. A
, vol.34
, pp. 1007-1013
-
-
Hao, Y.L.1
Niinomi, M.2
Kuroda, D.3
Fukunaga, K.4
Yang, R.5
Suzuki, A.6
-
3
-
-
0037003833
-
Development of low rigidity β-type titanium alloy for biomedical applications
-
M. Niinomi, T. Hattori, K. Morikawa, T. Kasuga, A. Suzuki, H. Fukui, and S. Niwa Development of low rigidity β-type titanium alloy for biomedical applications Mater. Trans. 43 2002 2970 2977
-
(2002)
Mater. Trans.
, vol.43
, pp. 2970-2977
-
-
Niinomi, M.1
Hattori, T.2
Morikawa, K.3
Kasuga, T.4
Suzuki, A.5
Fukui, H.6
Niwa, S.7
-
4
-
-
0032487135
-
Quasi-biological apatite film induced by titanium in a simulated body fluid
-
P. Li, and P. Ducheyne Quasi-biological apatite film induced by titanium in a simulated body fluid J. Biomed. Mater. Res. A 41 1998 341 348
-
(1998)
J. Biomed. Mater. Res. A
, vol.41
, pp. 341-348
-
-
Li, P.1
Ducheyne, P.2
-
5
-
-
0003010929
-
Titanium and its oxide film substrate for formation of apatite
-
J.E. Davies, University of Toronto Press Toronto
-
T. Hanawa Titanium and its oxide film substrate for formation of apatite J.E. Davies, The Bone-Biomaterial Interface 2002 University of Toronto Press Toronto 49 61
-
(2002)
The Bone-Biomaterial Interface
, pp. 49-61
-
-
Hanawa, T.1
-
6
-
-
0025918458
-
Calcium phosphate naturally formed on titanium in electrolyte solution
-
T. Hanawa, and M. Ota Calcium phosphate naturally formed on titanium in electrolyte solution Biomaterials 12 1991 767 774
-
(1991)
Biomaterials
, vol.12
, pp. 767-774
-
-
Hanawa, T.1
Ota, M.2
-
7
-
-
0032052625
-
Electrochemical and surface characterization of a nickel-titanium alloy
-
D.J. Wever, A.G. Veldhuizen, J. de Vries, H.J. Busscher, D.R.A. Uges, and J.R. van Horn Electrochemical and surface characterization of a nickel-titanium alloy Biomaterials 19 1998 761 769
-
(1998)
Biomaterials
, vol.19
, pp. 761-769
-
-
Wever, D.J.1
Veldhuizen, A.G.2
De Vries, J.3
Busscher, H.J.4
Uges, D.R.A.5
Van Horn, J.R.6
-
8
-
-
0000975161
-
Compositional change in surface of Ti-Zr alloys in artificial bioliquid
-
T. Hanawa, O. Okuno, and H. Hamanaka Compositional change in surface of Ti-Zr alloys in artificial bioliquid J. Jpn. Inst. Metals 56 1992 1168 1173
-
(1992)
J. Jpn. Inst. Metals
, vol.56
, pp. 1168-1173
-
-
Hanawa, T.1
Okuno, O.2
Hamanaka, H.3
-
9
-
-
0029239821
-
Spectroscopic characterization of passivated titanium in a physiologic solution
-
J.L. Ong, L.C. Lucas, G.N. Raikar, R. Connatser, and J.C. Gregory Spectroscopic characterization of passivated titanium in a physiologic solution J. Mater. Sci.: Mater. Med. 6 1995 113 119
-
(1995)
J. Mater. Sci.: Mater. Med.
, vol.6
, pp. 113-119
-
-
Ong, J.L.1
Lucas, L.C.2
Raikar, G.N.3
Connatser, R.4
Gregory, J.C.5
-
10
-
-
0242438597
-
Composition of surface oxide film of titanium with culturing murine fibroblasts L929
-
S. Hiromoto, T. Hanawa, and K. Asami Composition of surface oxide film of titanium with culturing murine fibroblasts L929 Biomaterials 25 2004 979 986
-
(2004)
Biomaterials
, vol.25
, pp. 979-986
-
-
Hiromoto, S.1
Hanawa, T.2
Asami, K.3
-
11
-
-
0029361094
-
Characterization of thin hydroxyapatite layers formed on anodic titanium oxide films containing Ca and P by hydrothermal treatment
-
H. Ishizawa, and M. Ogino Characterization of thin hydroxyapatite layers formed on anodic titanium oxide films containing Ca and P by hydrothermal treatment J. Biomed. Mater. Res. 29 1995 1071 1079
-
(1995)
J. Biomed. Mater. Res.
, vol.29
, pp. 1071-1079
-
-
Ishizawa, H.1
Ogino, M.2
-
12
-
-
0037461450
-
Structure and in vitro bioactivity of titania-based films by micro-arc oxidation
-
Y. Han, S.H. Hong, and K.W. Xu Structure and in vitro bioactivity of titania-based films by micro-arc oxidation Surf. Coat. Technol. 168 2003 249 258
-
(2003)
Surf. Coat. Technol.
, vol.168
, pp. 249-258
-
-
Han, Y.1
Hong, S.H.2
Xu, K.W.3
-
13
-
-
23044473009
-
Formation of hydroxyapatite on Ti-6Al-4V alloy by micro-arc oxidation and hydrothermal treatment
-
F. Liu, F.P. Wang, T. Shimizu, K. Igarashi, and L.C. Zhao Formation of hydroxyapatite on Ti-6Al-4V alloy by micro-arc oxidation and hydrothermal treatment Surf. Coat. Technol. 199 2005 220 224
-
(2005)
Surf. Coat. Technol.
, vol.199
, pp. 220-224
-
-
Liu, F.1
Wang, F.P.2
Shimizu, T.3
Igarashi, K.4
Zhao, L.C.5
-
14
-
-
45749129710
-
Histological evaluation and surface componential analysis of modified micro-arc oxidation-treated titanium implants
-
W. Ma, J.H. Wei, Y.Z. Li, X.M. Wang, H.Y. Shi, S. Tsutsumi, and D.H. Li Histological evaluation and surface componential analysis of modified micro-arc oxidation-treated titanium implants, J. Biomed. Mater. Res. 86B 2008 162 169
-
(2008)
J. Biomed. Mater. Res.
, vol.86 B
, pp. 162-169
-
-
Ma, W.1
Wei, J.H.2
Li, Y.Z.3
Wang, X.M.4
Shi, H.Y.5
Tsutsumi, S.6
Li, D.H.7
-
15
-
-
42749093443
-
The effect of chemical treatment on apatite-forming ability of the macroporous zirconia films formed by micro-arc oxidation
-
Y. Yan, Y. Han, and C. Lu The effect of chemical treatment on apatite-forming ability of the macroporous zirconia films formed by micro-arc oxidation Appl. Surf. Sci. 254 2008 4833 4839
-
(2008)
Appl. Surf. Sci.
, vol.254
, pp. 4833-4839
-
-
Yan, Y.1
Han, Y.2
Lu, C.3
-
16
-
-
79959508379
-
Enhancement of calcium phosphate formation on zirconium by micro-arc oxidation and chemical treatments
-
J.Y. Ha, Y. Tsutsumi, H. Doi, N. Nomura, K.H. Kim, and T. Hanawa Enhancement of calcium phosphate formation on zirconium by micro-arc oxidation and chemical treatments Surf. Coat. Technol. 205 2011 4948 4955
-
(2011)
Surf. Coat. Technol.
, vol.205
, pp. 4948-4955
-
-
Ha, J.Y.1
Tsutsumi, Y.2
Doi, H.3
Nomura, N.4
Kim, K.H.5
Hanawa, T.6
-
17
-
-
0037209993
-
Effect of hydrothermally treated anodic oxide films on osteoblast attachment and proliferation
-
J.Y. Suh, B.C. Janga, X. Zhu, J.L. Ong, and K.H. Kim Effect of hydrothermally treated anodic oxide films on osteoblast attachment and proliferation Biomaterials 24 2003 347 355
-
(2003)
Biomaterials
, vol.24
, pp. 347-355
-
-
Suh, J.Y.1
Janga, B.C.2
Zhu, X.3
Ong, J.L.4
Kim, K.H.5
-
18
-
-
0344738845
-
In vivo histological response to anodized and anodized/hydrothermally treated titanium implants
-
W.W. Son, X. Zhu, H.I. Shin, J.L. Ong, and K.H. Kim In vivo histological response to anodized and anodized/hydrothermally treated titanium implants, J. Biomed. Mater. Res. B Appl. Biomater. 66B 2003 520 525
-
(2003)
J. Biomed. Mater. Res. B Appl. Biomater.
, vol.66 B
, pp. 520-525
-
-
Son, W.W.1
Zhu, X.2
Shin, H.I.3
Ong, J.L.4
Kim, K.H.5
-
19
-
-
34248526191
-
Calcium phosphate formation on titanium by low-voltage electrolytic treatments
-
Y. Tanaka, E. Kobayashi, S. Hiromoto, K. Asami, H. Imai, and T. Hanawa Calcium phosphate formation on titanium by low-voltage electrolytic treatments J. Mater. Sci.: Mater. Med. 18 2007 797 806
-
(2007)
J. Mater. Sci.: Mater. Med.
, vol.18
, pp. 797-806
-
-
Tanaka, Y.1
Kobayashi, E.2
Hiromoto, S.3
Asami, K.4
Imai, H.5
Hanawa, T.6
-
20
-
-
33744538097
-
High-resolution X-ray photoemission spectrum of the valence bands of gold
-
D.A. Shirley High-resolution X-ray photoemission spectrum of the valence bands of gold Phys. Rev. B5 1972 552 556
-
(1972)
Phys. Rev.
, vol.5 B
, pp. 552-556
-
-
Shirley, D.A.1
-
21
-
-
0017632531
-
XPS determination of compositions of alloy surfaces and surface oxides on mechanically polished iron-chromium alloys
-
K. Asami, K. Hashimoto, and S. Shimodaira XPS determination of compositions of alloy surfaces and surface oxides on mechanically polished iron-chromium alloys Corros. Sci. 17 1977 713 723
-
(1977)
Corros. Sci.
, vol.17
, pp. 713-723
-
-
Asami, K.1
Hashimoto, K.2
Shimodaira, S.3
-
22
-
-
0025624253
-
A photoelectrochemical and ESCA study of passivity of amorphous nickel-valve metal alloys
-
K. Asami, S.C. Chen, H. Habazaki, A. Kawashima, and K. Hashimoto A photoelectrochemical and ESCA study of passivity of amorphous nickel-valve metal alloys Corros. Sci. 31 1990 727 732
-
(1990)
Corros. Sci.
, vol.31
, pp. 727-732
-
-
Asami, K.1
Chen, S.C.2
Habazaki, H.3
Kawashima, A.4
Hashimoto, K.5
-
23
-
-
0017727412
-
Electrochemical and XPS studies on corrosion behavior of amorphous Ni-Cr-P-B alloys
-
K. Hashimoto, M. Kasaya, K. Asami, and T. Masumoto Electrochemical and XPS studies on corrosion behavior of amorphous Ni-Cr-P-B alloys Corros. Eng. 26 1977 445 452
-
(1977)
Corros. Eng.
, vol.26
, pp. 445-452
-
-
Hashimoto, K.1
Kasaya, M.2
Asami, K.3
Masumoto, T.4
-
24
-
-
0041742046
-
Hartree-Slater subshell photoionization cross-sections at 1254 and 1487 eV
-
J.H. Scofield Hartree-Slater subshell photoionization cross-sections at 1254 and 1487 eV J. Electron Spectrosc. Relat. Phenom. 8 1976 129 137
-
(1976)
J. Electron Spectrosc. Relat. Phenom.
, vol.8
, pp. 129-137
-
-
Scofield, J.H.1
-
25
-
-
0027807808
-
The surface characterization of titanium and titanium-nickel alloys in sulfuric acid
-
K. Asami, S.C. Chen, H. Habazaki, and K. Hashimoto The surface characterization of titanium and titanium-nickel alloys in sulfuric acid Corros. Sci. 35 1993 43 49
-
(1993)
Corros. Sci.
, vol.35
, pp. 43-49
-
-
Asami, K.1
Chen, S.C.2
Habazaki, H.3
Hashimoto, K.4
-
26
-
-
0033723102
-
Oxidation of a polycrystalline titanium surface by oxygen and water
-
G. Lu, S.L. Bernasek, and J. Schwartz Oxidation of a polycrystalline titanium surface by oxygen and water Surf. Sci. 458 2000 80 90
-
(2000)
Surf. Sci.
, vol.458
, pp. 80-90
-
-
Lu, G.1
Bernasek, S.L.2
Schwartz, J.3
-
27
-
-
0035851262
-
Characterization of the surface oxide film of a Co-Cr-Mo alloy after being located in quasi-biological environments using XPS
-
T. Hanawa, S. Hiromoto, and K. Asami Characterization of the surface oxide film of a Co-Cr-Mo alloy after being located in quasi-biological environments using XPS Appl. Surf. Sci. 183 2001 68 75
-
(2001)
Appl. Surf. Sci.
, vol.183
, pp. 68-75
-
-
Hanawa, T.1
Hiromoto, S.2
Asami, K.3
|