메뉴 건너뛰기




Volumn 52, Issue 4, 2012, Pages 359-364

Posterior interspinous fusion device for one-level fusion in degenerative lumbar spine disease: Comparison with pedicle screw fixation - preliminary report of at least one year follow up

Author keywords

Adjacent segmental degeneration; Degenerative; Fusion device; Interspinous; Lumbar disease; Posterior

Indexed keywords

ADJACENT SEGMENTAL DEGENERATION; ADULT; ARTICLE; CONTROLLED STUDY; DEVICE SAFETY; FEMALE; FOLLOW UP; HUMAN; INTERVERTEBRAL DISK HERNIA; LUMBAR SPINE; MAJOR CLINICAL STUDY; MALE; OSWESTRY DISABILITY INDEX; OUTCOME ASSESSMENT; PEDICLE SCREW; POSTOPERATIVE COMPLICATION; SPINE DISEASE; SPINE FUSION; SPINE RADIOGRAPHY; SPONDYLOLISTHESIS; SURGICAL RISK; VERTEBRAL CANAL STENOSIS; VISUAL ANALOG SCALE;

EID: 84868643289     PISSN: 20053711     EISSN: 15987876     Source Type: Journal    
DOI: 10.3340/jkns.2012.52.4.359     Document Type: Article
Times cited : (39)

References (23)
  • 1
    • 0027485491 scopus 로고
    • The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis
    • Bridwell KH, Sedgewick TA, O'Brien MF, Lenke LG, Baldus C: The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord 6: 461-472, 1993
    • (1993) J Spinal Disord , vol.6 , pp. 461-472
    • Bridwell, K.H.1    Sedgewick, T.A.2    O'Brien, M.F.3    Lenke, L.G.4    Baldus, C.5
  • 2
    • 67649130670 scopus 로고    scopus 로고
    • Does superior-segment facet violation or laminectomy destabilize the adjacent level in lumbar transpedicular fixation? An in vitro human cadaveric assessment
    • Cardoso MJ, Dmitriev AE, Helgeson M, Lehman RA, Kuklo TR, Rosner MK: Does superior-segment facet violation or laminectomy destabilize the adjacent level in lumbar transpedicular fixation? An in vitro human cadaveric assessment. Spine (Phila Pa 1976) 33: 2868-2873, 2008
    • (2008) Spine (Phila Pa 1976) , vol.33 , pp. 2868-2873
    • Cardoso, M.J.1    Dmitriev, A.E.2    Helgeson, M.3    Lehman, R.A.4    Kuklo, T.R.5    Rosner, M.K.6
  • 3
    • 0031427748 scopus 로고    scopus 로고
    • The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure: An in vitro biomechanical analysis
    • Cunningham BW, Kotani Y, McNulty PS, Cappuccino A, McAfee PC: The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure: an in vitro biomechanical analysis. Spine (Phila Pa 1976) 22: 2655-2663, 1997
    • (1997) Spine (Phila Pa 1976) , vol.22 , pp. 2655-2663
    • Cunningham, B.W.1    Kotani, Y.2    McNulty, P.S.3    Cappuccino, A.4    McAfee, P.C.5
  • 4
    • 0026439770 scopus 로고
    • Transpedicular screw-rod fixation of the lumbar spine: Operative technique and outcome in 104 cases
    • Dickman CA, Fessler RG, MacMillan M, Haid RW: Transpedicular screw-rod fixation of the lumbar spine: operative technique and outcome in 104 cases. J Neurosurg 77: 860-870, 1992
    • (1992) J Neurosurg , vol.77 , pp. 860-870
    • Dickman, C.A.1    Fessler, R.G.2    Macmillan, M.3    Haid, R.W.4
  • 5
    • 0027484342 scopus 로고    scopus 로고
    • Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members
    • discussion 2239, 1993
    • Esses SI, Sachs BL, Dreyzin V: Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976) 18: 2231-2238; discussion 2239, 1993
    • Spine (Phila Pa 1976) , vol.18 , pp. 2231-2238
    • Esses, S.I.1    Sachs, B.L.2    Dreyzin, V.3
  • 6
    • 0031573532 scopus 로고    scopus 로고
    • 1997 Volvo Award winner in clinical studies. Degenerative lumbar spondylolisthesis with spinal stenosis: A prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation
    • Fischgrund JS, Mackay M, Herkowitz HN, Brower R, Montgomery DM, Kurz LT: 1997 Volvo Award winner in clinical studies. Degenerative lumbar spondylolisthesis with spinal stenosis: a prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation. Spine (Phila Pa 1976) 22: 2807-2812, 1997
    • (1997) Spine (Phila Pa 1976) , vol.22 , pp. 2807-2812
    • Fischgrund, J.S.1    Mackay, M.2    Herkowitz, H.N.3    Brower, R.4    Montgomery, D.M.5    Kurz, L.T.6
  • 7
    • 0038046361 scopus 로고    scopus 로고
    • L5-S1 segment survivorship and clinical outcome analysis after L4-L5 isolated fusion
    • discussion 1280, 2003
    • Ghiselli G, Wang JC, Hsu WK, Dawson EG: L5-S1 segment survivorship and clinical outcome analysis after L4-L5 isolated fusion. Spine (Phila Pa 1976) 12: 1275-1280; discussion 1280, 2003
    • Spine (Phila Pa 1976) , vol.12 , pp. 1275-1280
    • Ghiselli, G.1    Wang, J.C.2    Hsu, W.K.3    Dawson, E.G.4
  • 8
    • 8644271684 scopus 로고    scopus 로고
    • Adjacent segment degeneration and adjacent segment disease: The consequences of spinal fusion?
    • Hilibrand AS, Robbins M: Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion? Spine J 4: 190S-194S, 2004
    • (2004) Spine J , vol.4
    • Hilibrand, A.S.1    Robbins, M.2
  • 9
    • 0036458441 scopus 로고    scopus 로고
    • Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations
    • Jutte PC, Castelein RM: Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 11: 594-598, 2002
    • (2002) Eur Spine J , vol.11 , pp. 594-598
    • Jutte, P.C.1    Castelein, R.M.2
  • 11
    • 34447558123 scopus 로고    scopus 로고
    • New interspinous implant evaluation using an in vitro biomechanical study combined with a finite-element analysis
    • Lafage V, Gangnet N, Sénégas J, Lavaste F, Skalli W: New interspinous implant evaluation using an in vitro biomechanical study combined with a finite-element analysis. Spine (Phila Pa 1976) 32: 1706-1713, 2007
    • (2007) Spine (Phila Pa 1976) , vol.32 , pp. 1706-1713
    • Lafage, V.1    Gangnet, N.2    Sénégas, J.3    Lavaste, F.4    Skalli, W.5
  • 12
    • 0021221787 scopus 로고
    • Lumbosacral spinal fusion. A biomechanical study
    • Lee CK, Langrana NA: Lumbosacral spinal fusion. A biomechanical study. Spine (Phila Pa 1976) 9: 574-581, 1984
    • (1984) Spine (Phila Pa 1976) , vol.9 , pp. 574-581
    • Lee, C.K.1    Langrana, N.A.2
  • 13
    • 0031043855 scopus 로고    scopus 로고
    • An in vitro study of the biomechanical effects of flexible stabilization on the lumbar spine
    • Papp T, Porter RW, Aspden RM, Shepperd JA: An in vitro study of the biomechanical effects of flexible stabilization on the lumbar spine. Spine (Phila Pa 1976) 22: 151-155, 1997
    • (1997) Spine (Phila Pa 1976) , vol.22 , pp. 151-155
    • Papp, T.1    Porter, R.W.2    Aspden, R.M.3    Shepperd, J.A.4
  • 14
  • 15
    • 0029919012 scopus 로고    scopus 로고
    • Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions
    • Schlegel JD, Smith JA, Schleusener RL: Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine (Phila Pa 1976) 21: 970-981, 1996
    • (1996) Spine (Phila Pa 1976) , vol.21 , pp. 970-981
    • Schlegel, J.D.1    Smith, J.A.2    Schleusener, R.L.3
  • 16
    • 33644837768 scopus 로고    scopus 로고
    • Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis
    • Schnake KJ, Schaeren S, Jeanneret B: Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine (Phila Pa 1976) 31: 442-449, 2006
    • (2006) Spine (Phila Pa 1976) , vol.31 , pp. 442-449
    • Schnake, K.J.1    Schaeren, S.2    Jeanneret, B.3
  • 17
    • 37249014966 scopus 로고    scopus 로고
    • Disc height reduction in adjacent segments and clinical outcome 10 years after lumbar 360 degrees fusion
    • Schulte TL, Leistra F, Bullmann V, Osada N, Vieth V, Marquardt B, et al.: Disc height reduction in adjacent segments and clinical outcome 10 years after lumbar 360 degrees fusion. Eur Spine J 16: 2152-2158, 2007
    • (2007) Eur Spine J , vol.16 , pp. 2152-2158
    • Schulte, T.L.1    Leistra, F.2    Bullmann, V.3    Osada, N.4    Vieth, V.5    Marquardt, B.6
  • 18
    • 0029266457 scopus 로고
    • Role of spinal instrumentation in fusion for degenerative disease of the lumbosacral spine
    • Sonntag VK, Marciano FF: Role of spinal instrumentation in fusion for degenerative disease of the lumbosacral spine. West J Med 162: 262-263, 1995
    • (1995) West J Med , vol.162 , pp. 262-263
    • Sonntag, V.K.1    Marciano, F.F.2
  • 19
    • 0031573727 scopus 로고    scopus 로고
    • 1997 Volvo Award winner in clinical studies. The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion: A prospective, randomized clinical study
    • Thomsen K, Christensen FB, Eiskjaer SP, Hansen ES, Fruensgaard S, Bünger CE: 1997 Volvo Award winner in clinical studies. The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion: a prospective, randomized clinical study. Spine (Phila Pa 1976) 22: 2813-2822, 1997
    • (1997) Spine (Phila Pa 1976) , vol.22 , pp. 2813-2822
    • Thomsen, K.1    Christensen, F.B.2    Eiskjaer, S.P.3    Hansen, E.S.4    Fruensgaard, S.5    Bünger, C.E.6
  • 20
    • 33644882760 scopus 로고    scopus 로고
    • Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion
    • Invited submission from the Joint Section Meeting On Disorders of the Spine and Peripheral Nerves, March 2005
    • Wang JC, Haid RW Jr, Miller JS, Robinson JC: Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting On Disorders of the Spine and Peripheral Nerves, March 2005. J Neurosurg Spine 4: 132-136, 2006
    • (2006) J Neurosurg Spine , vol.4 , pp. 132-136
    • Wang, J.C.1    Haid Jr., R.W.2    Miller, J.S.3    Robinson, J.C.4
  • 21
    • 33644886881 scopus 로고    scopus 로고
    • SPIRE spinous process stabilization plate: Biomechanical evaluation of a novel technology
    • Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005
    • Wang JC, Spenciner D, Robinson JC: SPIRE spinous process stabilization plate: biomechanical evaluation of a novel technology. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005. J Neurosurg Spine 4: 160-164, 2006
    • (2006) J Neurosurg Spine , vol.4 , pp. 160-164
    • Wang, J.C.1    Spenciner, D.2    Robinson, J.C.3
  • 22
    • 0025879589 scopus 로고
    • Complications of the variable screw plate pedicle screw fixation
    • West JL 3rd, Ogilvie JW, Bradford DS: Complications of the variable screw plate pedicle screw fixation. Spine (Phila Pa 1976) 16: 576-579, 1991
    • (1991) Spine (Phila Pa 1976) , vol.16 , pp. 576-579
    • West III, J.L.1    Ogilvie, J.W.2    Bradford, D.S.3
  • 23
    • 0027300763 scopus 로고
    • A prospective, randomized study of lumbar fusion. Preliminary results
    • Zdelblick TA: A prospective, randomized study of lumbar fusion. Preliminary results. Spine (Phila Pa 1976) 18: 983-991, 1993
    • (1993) Spine (Phila Pa 1976) , vol.18 , pp. 983-991
    • Zdelblick, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.