메뉴 건너뛰기




Volumn 4, Issue 2, 2006, Pages 160-164

SPIRE spinous process stabilization plate: Biomechanical evaluation of a novel technology. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005

Author keywords

Biomechanics; Degenerative disc disease; Lumbar spine; Pedicle screw; Plate fixation; Posterior lumbar fixation; Spinous process

Indexed keywords

ANALYSIS OF VARIANCE; CONFERENCE PAPER; DEVICE; FLEXOR REFLEX; HUMAN; INTERMETHOD COMPARISON; INTERVERTEBRAL DISKECTOMY; INTRAMEDULLARY NAILING; LUMBAR SPINE; PEDICLE SCREW; PLATE FIXATION; RANGE OF MOTION; SPINE STABILIZATION; SPIRE PLATE; ADULT; AGED; ARTICLE; BIOMECHANICS; BONE PLATE; BONE SCREW; CADAVER; FEMALE; INSTRUMENTATION; INTERVERTEBRAL DISK; INTERVERTEBRAL DISK HERNIA; LUMBAR VERTEBRA; MALE; MATERIALS TESTING; MIDDLE AGED; ORTHOPEDIC EQUIPMENT; PATHOLOGY; PROSTHESIS; SPINE FUSION;

EID: 33644886881     PISSN: 15475654     EISSN: None     Source Type: Journal    
DOI: 10.3171/spi.2006.4.2.160     Document Type: Conference Paper
Times cited : (36)

References (11)
  • 1
    • 0021182917 scopus 로고    scopus 로고
    • Bostman O, Myllynen P. Riska EB: Posterior spinal fusion using internal fixation with the Daab plate. Acta Orthop Scand 55:310-314, 1984
    • Bostman O, Myllynen P. Riska EB: Posterior spinal fusion using internal fixation with the Daab plate. Acta Orthop Scand 55:310-314, 1984
  • 2
    • 0015056692 scopus 로고
    • The value of the Wilson plate in spinal fusion
    • Cobey MC: The value of the Wilson plate in spinal fusion. Clin Orthop Relat Res 76:138-140, 1971
    • (1971) Clin Orthop Relat Res , vol.76 , pp. 138-140
    • Cobey, M.C.1
  • 3
    • 0025153831 scopus 로고
    • Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires
    • Coe JD, Warden KE, Herzig MA, McAfee PC: Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires. Spine 15:902-907, 1990
    • (1990) Spine , vol.15 , pp. 902-907
    • Coe, J.D.1    Warden, K.E.2    Herzig, M.A.3    McAfee, P.C.4
  • 5
    • 0027484342 scopus 로고
    • Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members
    • Esses SI, Sachs BL, Dreyzin V: Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18:2231-2239, 1993
    • (1993) Spine , vol.18 , pp. 2231-2239
    • Esses, S.I.1    Sachs, B.L.2    Dreyzin, V.3
  • 6
    • 0023616509 scopus 로고
    • Biomechanical comparison of seven internal fixation devices for the lumbosacral junction
    • Guyer DW, Yuan HA, Werner FW, Frederickson BE, Murphy D: Biomechanical comparison of seven internal fixation devices for the lumbosacral junction. Spine 12:569-573, 1987
    • (1987) Spine , vol.12 , pp. 569-573
    • Guyer, D.W.1    Yuan, H.A.2    Werner, F.W.3    Frederickson, B.E.4    Murphy, D.5
  • 7
    • 0031975480 scopus 로고    scopus 로고
    • Stability of different wiring techniques in segmental spinal instrumentation. An experimental study
    • Heller KD, Prescher A, Schneider T, Block FR, Forst R: Stability of different wiring techniques in segmental spinal instrumentation. An experimental study. Arch Orthop Trauma Surg 117:96-99, 1998
    • (1998) Arch Orthop Trauma Surg , vol.117 , pp. 96-99
    • Heller, K.D.1    Prescher, A.2    Schneider, T.3    Block, F.R.4    Forst, R.5
  • 8
    • 0036458441 scopus 로고    scopus 로고
    • Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations
    • Jutte PC, Castelein RM: Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 11:594-598, 2002
    • (2002) Eur Spine J , vol.11 , pp. 594-598
    • Jutte, P.C.1    Castelein, R.M.2
  • 9
    • 0026040576 scopus 로고
    • Design and evaluation of a posterior laminar clamp spinal fixation system
    • Tencer AF, Self J, Allen BL Jr, Drummond D: Design and evaluation of a posterior laminar clamp spinal fixation system. Spine 16:910-918, 1991
    • (1991) Spine , vol.16 , pp. 910-918
    • Tencer, A.F.1    Self, J.2    Allen Jr, B.L.3    Drummond, D.4
  • 10
    • 33644882760 scopus 로고    scopus 로고
    • Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005
    • Wang JC, Haid RW Jr, Miller JS, Robinson JC: Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005. J Neurosurg Spine 4:132-136, 2006
    • (2006) J Neurosurg Spine , vol.4 , pp. 132-136
    • Wang, J.C.1    Haid Jr, R.W.2    Miller, J.S.3    Robinson, J.C.4
  • 11
    • 0027300763 scopus 로고
    • A prospective, randomized study of lumbar fusion. Preliminary results
    • Zdeblick TA: A prospective, randomized study of lumbar fusion. Preliminary results. Spine 18:983-991, 1993
    • (1993) Spine , vol.18 , pp. 983-991
    • Zdeblick, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.