메뉴 건너뛰기




Volumn 37, Issue 4, 2012, Pages 396-400

Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer

Author keywords

Interfraction rotation; KV image guided radiotherapy; On line target localization; Prostate fiducials

Indexed keywords

ADULT; ARTICLE; CANCER LOCALIZATION; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COHORT ANALYSIS; COMPUTER PROGRAM; CONTROLLED STUDY; DOSIMETRY; FEASIBILITY STUDY; FIDUCIAL MARKER; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; INTENSITY MODULATED RADIATION THERAPY; MALE; PRIORITY JOURNAL; PROSTATE CANCER; RADIATION DOSE DISTRIBUTION; RADIATION FIELD;

EID: 84868197068     PISSN: 09583947     EISSN: 18734022     Source Type: Journal    
DOI: 10.1016/j.meddos.2012.02.006     Document Type: Article
Times cited : (27)

References (40)
  • 1
    • 32844463684 scopus 로고    scopus 로고
    • The efficacy of conventional external beam, three-dimensional conformal, intensity-modulated, particle beam radiation, and brachytherapy for localized prostate cancer
    • Eng T.Y., Luh J.Y., Thomas C.R. The efficacy of conventional external beam, three-dimensional conformal, intensity-modulated, particle beam radiation, and brachytherapy for localized prostate cancer. Curr. Urol. Rep. 2005, 6:194-209.
    • (2005) Curr. Urol. Rep. , vol.6 , pp. 194-209
    • Eng, T.Y.1    Luh, J.Y.2    Thomas, C.R.3
  • 2
    • 25844451193 scopus 로고    scopus 로고
    • Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging
    • Schallenkamp J.M., Herman M.G., Kruse J.J., et al. Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging. Int. J. Radiat. Oncol. Biol. Phys. 2005, 63:800-811.
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.63 , pp. 800-811
    • Schallenkamp, J.M.1    Herman, M.G.2    Kruse, J.J.3
  • 4
    • 0028960870 scopus 로고
    • Control, correction, and modeling of setup errors and organ motion
    • Kutcher G.J., Mageras G.S., Liebel S.A. Control, correction, and modeling of setup errors and organ motion. Semin. Radiat. Oncol. 1995, 5:134-145.
    • (1995) Semin. Radiat. Oncol. , vol.5 , pp. 134-145
    • Kutcher, G.J.1    Mageras, G.S.2    Liebel, S.A.3
  • 5
    • 0034748364 scopus 로고    scopus 로고
    • Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers
    • Wu J., Haycocks T., Alasti H., et al. Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers. Radiother. Oncol. 2001, 61:127-133.
    • (2001) Radiother. Oncol. , vol.61 , pp. 127-133
    • Wu, J.1    Haycocks, T.2    Alasti, H.3
  • 6
    • 0038030020 scopus 로고    scopus 로고
    • Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging
    • Verellen D., Soete G., Linthout N., et al. Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging. Radiother. Oncol. 2003, 67:129-141.
    • (2003) Radiother. Oncol. , vol.67 , pp. 129-141
    • Verellen, D.1    Soete, G.2    Linthout, N.3
  • 7
    • 0036834636 scopus 로고    scopus 로고
    • Clinical use of stereoscopic X-ray positioning of patients treated with conformal radiotherapy for prostate cancer
    • Soete G., Verellen D., Michielsen D., et al. Clinical use of stereoscopic X-ray positioning of patients treated with conformal radiotherapy for prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2002, 54:948-952.
    • (2002) Int. J. Radiat. Oncol. Biol. Phys. , vol.54 , pp. 948-952
    • Soete, G.1    Verellen, D.2    Michielsen, D.3
  • 8
    • 4644289998 scopus 로고    scopus 로고
    • Trans-perineal implantation of radio-opaque treatment verification markers into the prostate: An assessment of procedure related morbidity, patient acceptability and accuracy
    • Henry A.M., Wilkinson C., Wylie J.P., et al. Trans-perineal implantation of radio-opaque treatment verification markers into the prostate: An assessment of procedure related morbidity, patient acceptability and accuracy. Radiother. Oncol. 2004, 73:57-59.
    • (2004) Radiother. Oncol. , vol.73 , pp. 57-59
    • Henry, A.M.1    Wilkinson, C.2    Wylie, J.P.3
  • 9
    • 22144456659 scopus 로고    scopus 로고
    • Intraprostatic fiducials for localization of the prostate gland: Monitoring intermarker distances during radiation therapy to test for marker stability
    • Kupelian P.A., Willoughby T.R., Meeks S.L., et al. Intraprostatic fiducials for localization of the prostate gland: Monitoring intermarker distances during radiation therapy to test for marker stability. Int. J. Radiat. Oncol. Biol. Phys. 2005, 62:1291-1296.
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.62 , pp. 1291-1296
    • Kupelian, P.A.1    Willoughby, T.R.2    Meeks, S.L.3
  • 10
    • 0032951630 scopus 로고    scopus 로고
    • Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery
    • Cosgrove V.P., Jahn U., Pfaender M., et al. Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery. Radiother. Oncol. 1999, 50:325-336.
    • (1999) Radiother. Oncol. , vol.50 , pp. 325-336
    • Cosgrove, V.P.1    Jahn, U.2    Pfaender, M.3
  • 11
    • 0003651542 scopus 로고
    • International Commission on Radiation Units and Measurements, ICRU Report 50. Bethesda, MD
    • Prescribing, recording and reporting photon beam therapy 1993, International Commission on Radiation Units and Measurements, ICRU Report 50. Bethesda, MD.
    • (1993) Prescribing, recording and reporting photon beam therapy
  • 12
    • 33748677474 scopus 로고    scopus 로고
    • Setup accuracy of stereoscopic X-ray positioning with automated correction for rotational errors in patients treated with conformal arc radiotherapy for prostate cancer
    • Soete G., Verellen D., Tournel K., et al. Setup accuracy of stereoscopic X-ray positioning with automated correction for rotational errors in patients treated with conformal arc radiotherapy for prostate cancer. Radiother. Oncol. 2006, 80:371-373.
    • (2006) Radiother. Oncol. , vol.80 , pp. 371-373
    • Soete, G.1    Verellen, D.2    Tournel, K.3
  • 13
    • 0036499164 scopus 로고    scopus 로고
    • Initial clinical experience with infrared-reflecting skin markers in the positioning of patients treated by conformal radiotherapy for prostate cancer
    • Soete G., Van de Steene J., Verellen D., et al. Initial clinical experience with infrared-reflecting skin markers in the positioning of patients treated by conformal radiotherapy for prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2002, 52:694-698.
    • (2002) Int. J. Radiat. Oncol. Biol. Phys. , vol.52 , pp. 694-698
    • Soete, G.1    Van de Steene, J.2    Verellen, D.3
  • 14
    • 33644761975 scopus 로고    scopus 로고
    • From IMRT to IGRT: Frontierland or neverland?
    • Ling C.C., Yorke E., Fuks Z. From IMRT to IGRT: Frontierland or neverland?. Radiother. Oncol. 2006, 78:119-122.
    • (2006) Radiother. Oncol. , vol.78 , pp. 119-122
    • Ling, C.C.1    Yorke, E.2    Fuks, Z.3
  • 15
    • 36349032762 scopus 로고    scopus 로고
    • Fiducial-based quantification of prostate tilt using cone beam computer tomography (CBCT)
    • Boda-Heggemann J., Köhler F., Wertz H., et al. Fiducial-based quantification of prostate tilt using cone beam computer tomography (CBCT). Radiother. Oncol. 2007, 85:247-250.
    • (2007) Radiother. Oncol. , vol.85 , pp. 247-250
    • Boda-Heggemann, J.1    Köhler, F.2    Wertz, H.3
  • 16
    • 4644351656 scopus 로고    scopus 로고
    • Performing daily prostate targeting with a standard V-EPID and an automated radio-opaque marker detection algorithm
    • Beaulieu L., Girouard L.M., Aubin S., et al. Performing daily prostate targeting with a standard V-EPID and an automated radio-opaque marker detection algorithm. Radiother. Oncol. 2004, 73:61-64.
    • (2004) Radiother. Oncol. , vol.73 , pp. 61-64
    • Beaulieu, L.1    Girouard, L.M.2    Aubin, S.3
  • 17
    • 0028811317 scopus 로고
    • Prostate motion during standard radiotherapy as assessed by fiducial markers
    • Crook J.M., Raymond Y., Salhani D., et al. Prostate motion during standard radiotherapy as assessed by fiducial markers. Radiother. Oncol. 1995, 37:35-42.
    • (1995) Radiother. Oncol. , vol.37 , pp. 35-42
    • Crook, J.M.1    Raymond, Y.2    Salhani, D.3
  • 18
    • 0142043343 scopus 로고    scopus 로고
    • Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials
    • Nederveen A.J., Dehnad H., van der Heide U.A., et al. Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials. Radiother. Oncol. 2003, 68:81-88.
    • (2003) Radiother. Oncol. , vol.68 , pp. 81-88
    • Nederveen, A.J.1    Dehnad, H.2    van der Heide, U.A.3
  • 19
    • 4444285372 scopus 로고    scopus 로고
    • On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma
    • Chung P.W., Haycocks T., Brown T., et al. On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma. Int. J. Radiat. Oncol. Biol. Phys. 2004, 60:329-334.
    • (2004) Int. J. Radiat. Oncol. Biol. Phys. , vol.60 , pp. 329-334
    • Chung, P.W.1    Haycocks, T.2    Brown, T.3
  • 20
    • 0034653323 scopus 로고    scopus 로고
    • 3-D portal image analysis in clinical practice: An evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients
    • Remeijer P., Geerlof E., Ploeger L., et al. 3-D portal image analysis in clinical practice: An evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients. Int. J. Radiat. Oncol. Biol. Phys. 2000, 46:1281-1290.
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.46 , pp. 1281-1290
    • Remeijer, P.1    Geerlof, E.2    Ploeger, L.3
  • 21
    • 0028803534 scopus 로고
    • Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
    • van Herk M., Bruce A., Kroes A.P., et al. Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. Int. J. Radiat. Oncol. Biol. Phys. 1995, 33:1311-1320.
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.33 , pp. 1311-1320
    • van Herk, M.1    Bruce, A.2    Kroes, A.P.3
  • 22
    • 4444270625 scopus 로고    scopus 로고
    • Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers
    • Aubry J.F., Beaulieu L., Girouard L.M., et al. Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers. Int. J. Radiat. Oncol. Biol. Phys. 2004, 60:30-39.
    • (2004) Int. J. Radiat. Oncol. Biol. Phys. , vol.60 , pp. 30-39
    • Aubry, J.F.1    Beaulieu, L.2    Girouard, L.M.3
  • 23
    • 34248640300 scopus 로고    scopus 로고
    • Assessment of secondary patient motion induced by automated couch movement during on-line 6 dimensional repositioning in prostate cancer treatment
    • Linthout N., Verellen D., Tournel K., et al. Assessment of secondary patient motion induced by automated couch movement during on-line 6 dimensional repositioning in prostate cancer treatment. Radiother. Oncol. 2007, 83:168-174.
    • (2007) Radiother. Oncol. , vol.83 , pp. 168-174
    • Linthout, N.1    Verellen, D.2    Tournel, K.3
  • 24
    • 14744296853 scopus 로고    scopus 로고
    • Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer
    • Hoogeman M.S., van Herk M., de Bois J., et al. Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer. Radiother. Oncol. 2005, 74:177-185.
    • (2005) Radiother. Oncol. , vol.74 , pp. 177-185
    • Hoogeman, M.S.1    van Herk, M.2    de Bois, J.3
  • 25
    • 33748878207 scopus 로고    scopus 로고
    • Emptying the rectum before treatment delivery limits the variations of rectal dose - volume parameters during 3DCRT of prostate cancer
    • Stasi M., Munoz F., Fiorino C., et al. Emptying the rectum before treatment delivery limits the variations of rectal dose - volume parameters during 3DCRT of prostate cancer. Radiother. Oncol. 2006, 80:363-370.
    • (2006) Radiother. Oncol. , vol.80 , pp. 363-370
    • Stasi, M.1    Munoz, F.2    Fiorino, C.3
  • 26
    • 34247494807 scopus 로고    scopus 로고
    • Effect of bladder filling on doses to prostate and organs at risk: A treatment planning study
    • Moiseenko V., Liu M., Kristensen S., et al. Effect of bladder filling on doses to prostate and organs at risk: A treatment planning study. J. Appl. Clin. Med. Phys. 2007, 8:55-68.
    • (2007) J. Appl. Clin. Med. Phys. , vol.8 , pp. 55-68
    • Moiseenko, V.1    Liu, M.2    Kristensen, S.3
  • 27
    • 67349194708 scopus 로고    scopus 로고
    • Conformal arc radiotherapy for prostate cancer: Increased biochemical failure in patients with distended rectum on the planning computed tomogram despite image guidance by implanted Markers
    • Engels B., Soete G., Verellen D., et al. Conformal arc radiotherapy for prostate cancer: Increased biochemical failure in patients with distended rectum on the planning computed tomogram despite image guidance by implanted Markers. Int. J. Radiat. Oncol. Biol. Phys. 2009, 74:388-391.
    • (2009) Int. J. Radiat. Oncol. Biol. Phys. , vol.74 , pp. 388-391
    • Engels, B.1    Soete, G.2    Verellen, D.3
  • 28
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • Van Herk M., Remeijer P., Rasch C., et al. The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy. Int. J. Radiat. Oncol. Biol. Phys. 2000, 47:1121-1135.
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.47 , pp. 1121-1135
    • Van Herk, M.1    Remeijer, P.2    Rasch, C.3
  • 29
    • 39749094602 scopus 로고    scopus 로고
    • Evaluation of image-guidance strategies in the treatment of localized prostate cancer
    • Kupelian P.A., Lee C., Langen K.M., et al. Evaluation of image-guidance strategies in the treatment of localized prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2008, 70:1151-1157.
    • (2008) Int. J. Radiat. Oncol. Biol. Phys. , vol.70 , pp. 1151-1157
    • Kupelian, P.A.1    Lee, C.2    Langen, K.M.3
  • 30
    • 14844330713 scopus 로고    scopus 로고
    • Application of the no action level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markers
    • De Boer H.C., van Os M.J., Jansen P.P., et al. Application of the no action level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markers. Int. J. Radiat. Oncol. Biol. Phys. 2005, 6:969-983.
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.6 , pp. 969-983
    • De Boer, H.C.1    van Os, M.J.2    Jansen, P.P.3
  • 31
    • 26944448269 scopus 로고    scopus 로고
    • Retrospective analysis of prostate cancer patients with implanted gold markers using off-line and adaptive therapy protocols
    • Litzenberg D.W., Balter J.M., Lam K.L., et al. Retrospective analysis of prostate cancer patients with implanted gold markers using off-line and adaptive therapy protocols. Int. J. Radiat. Oncol. Biol. Phys. 2005, 63:123-133.
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.63 , pp. 123-133
    • Litzenberg, D.W.1    Balter, J.M.2    Lam, K.L.3
  • 32
    • 36348964173 scopus 로고    scopus 로고
    • Residual set-up errors and margins in on-line image-guided prostate localization in radiotherapy
    • Poulsen P.R., Muren L.P., Høyer M. Residual set-up errors and margins in on-line image-guided prostate localization in radiotherapy. Radiother. Oncol. 2007, 85:201-206.
    • (2007) Radiother. Oncol. , vol.85 , pp. 201-206
    • Poulsen, P.R.1    Muren, L.P.2    Høyer, M.3
  • 33
    • 45849116534 scopus 로고    scopus 로고
    • Dosimetric evaluation of prostate rotations and their correction by couch rotations
    • Van Herten Y.R., van de Kamer J.B., van Wieringen N., et al. Dosimetric evaluation of prostate rotations and their correction by couch rotations. Radiother. Oncol. 2008, 88:156-162.
    • (2008) Radiother. Oncol. , vol.88 , pp. 156-162
    • Van Herten, Y.R.1    van de Kamer, J.B.2    van Wieringen, N.3
  • 34
    • 47949085026 scopus 로고    scopus 로고
    • A treatment planning investigation into the dosimetric effects of systematic prostate patient rotational set-up errors
    • Cranmer-Sargison G. A treatment planning investigation into the dosimetric effects of systematic prostate patient rotational set-up errors. Med. Dosim. 2008, 33:19-205.
    • (2008) Med. Dosim. , vol.33 , pp. 19-205
    • Cranmer-Sargison, G.1
  • 35
    • 33749606407 scopus 로고    scopus 로고
    • Dosimetric effects of patient rotational setup errors on prostate IMRT treatments
    • Fu W., Yang Y., Li X., et al. Dosimetric effects of patient rotational setup errors on prostate IMRT treatments. Phys. Med. Biol. 2006, 51:5321-5331.
    • (2006) Phys. Med. Biol. , vol.51 , pp. 5321-5331
    • Fu, W.1    Yang, Y.2    Li, X.3
  • 36
    • 23244444205 scopus 로고    scopus 로고
    • The sensitivity of dose distributions for organ motion and set-up uncertainties in prostate IMRT
    • Bos L.J., van der Geer J., van Herk M., et al. The sensitivity of dose distributions for organ motion and set-up uncertainties in prostate IMRT. Radiother. Oncol. 2005, 76:18-26.
    • (2005) Radiother. Oncol. , vol.76 , pp. 18-26
    • Bos, L.J.1    van der Geer, J.2    van Herk, M.3
  • 38
    • 0037966410 scopus 로고    scopus 로고
    • Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation
    • Dehnad H., Nederveen A.J., van der Heide U.A., et al. Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation. Radiother. Oncol. 2003, 67:295-302.
    • (2003) Radiother. Oncol. , vol.67 , pp. 295-302
    • Dehnad, H.1    Nederveen, A.J.2    van der Heide, U.A.3
  • 39
    • 0032976707 scopus 로고    scopus 로고
    • Internal organ motion in prostate cancer patients treated in prone and supine treatment position
    • Stroom J.C., Koper P.C., Korevaar G.A., et al. Internal organ motion in prostate cancer patients treated in prone and supine treatment position. Radiother. Oncol. 1999, 51:237-248.
    • (1999) Radiother. Oncol. , vol.51 , pp. 237-248
    • Stroom, J.C.1    Koper, P.C.2    Korevaar, G.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.