-
1
-
-
3042520594
-
Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system
-
J.L. Barker, A.S. Garden, and K.K. Ang Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system Int J Radiat Oncol Biol Phys 59 2004 960 970
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, pp. 960-970
-
-
Barker, J.L.1
Garden, A.S.2
Ang, K.K.3
-
2
-
-
0346106247
-
When should systematic patient positioning errors in radiotherapy be corrected?
-
T. Bortfeld, M. van Herk, and S.B. Jiang When should systematic patient positioning errors in radiotherapy be corrected? Phys Med Biol 47 2002 N297 N302
-
(2002)
Phys Med Biol
, vol.47
-
-
Bortfeld, T.1
Van Herk, M.2
Jiang, S.B.3
-
3
-
-
21244477043
-
Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control
-
L.A. Dawson, C. Eccles, J.-P. Bissonnette, and K.K. Brock Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control Int J Radiat Oncol Biol Phys 62 2005 1247 1252
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.62
, pp. 1247-1252
-
-
Dawson, L.A.1
Eccles, C.2
Bissonnette, J.-P.3
Brock, K.K.4
-
4
-
-
0037249948
-
Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer
-
S.C. Erridge, Y. Seppenwoolde, and S.H. Muller Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer Radiother Oncol 66 2003 75 85
-
(2003)
Radiother Oncol
, vol.66
, pp. 75-85
-
-
Erridge, S.C.1
Seppenwoolde, Y.2
Muller, S.H.3
-
6
-
-
23644445797
-
Engaging the vascular component of the tumor response
-
Z. Fuks, and R. Kolesnick Engaging the vascular component of the tumor response Cancer Cell 8 2005 89 91
-
(2005)
Cancer Cell
, vol.8
, pp. 89-91
-
-
Fuks, Z.1
Kolesnick, R.2
-
7
-
-
0142186646
-
Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device
-
M.G. Herman, T.M. Pisansky, J.J. Kruse, J.I. Prisciandaro, B.J. Davis, and B.F. King Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device Int J Radiat Oncol Biol Phys 57 2003 1131 1140
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.57
, pp. 1131-1140
-
-
Herman, M.G.1
Pisansky, T.M.2
Kruse, J.J.3
Prisciandaro, J.I.4
Davis, B.J.5
King, B.F.6
-
8
-
-
20644472432
-
Clinical use of electronic portal imaging
-
M.G. Herman Clinical use of electronic portal imaging Semin Radiat Oncol 15 2005 157 167
-
(2005)
Semin Radiat Oncol
, vol.15
, pp. 157-167
-
-
Herman, M.G.1
-
9
-
-
14744296853
-
Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer
-
M.S. Hoogeman, M. van Herk, J. deBois, and J.V. Lebesque Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer Radiother Oncol 74 2005 177 185
-
(2005)
Radiother Oncol
, vol.74
, pp. 177-185
-
-
Hoogeman, M.S.1
Van Herk, M.2
Debois, J.3
Lebesque, J.V.4
-
10
-
-
0037359794
-
Development of a semi-automatic alignment tool for accelerated localization of the prostate
-
C. Hua, D.M. Lovelock, and G.S. Mageras Development of a semi-automatic alignment tool for accelerated localization of the prostate Int J Radiat Oncol Biol Phys 55 2003 811 824
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.55
, pp. 811-824
-
-
Hua, C.1
Lovelock, D.M.2
Mageras, G.S.3
-
11
-
-
20644454162
-
Emergent technologies for 3-dimensional image-guided radiation delivery
-
D.A. Jaffray Emergent technologies for 3-dimensional image-guided radiation delivery Semin Radiat Oncol 15 2005 208 216
-
(2005)
Semin Radiat Oncol
, vol.15
, pp. 208-216
-
-
Jaffray, D.A.1
-
12
-
-
0036803209
-
Detection of organ movement in cervix cancer patients using a fluoroscopic electronic portal iimaging device and radiopaque markers
-
R.S.J.P. Kaatee, M.J.J. Olofsen, M.B.J. Verstraate, S. Quint, and B.J.M. Heijmen Detection of organ movement in cervix cancer patients using a fluoroscopic electronic portal iimaging device and radiopaque markers Int J Radiat Oncol Biol Phys 54 2002 576 583
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.54
, pp. 576-583
-
-
Kaatee, R.S.J.P.1
Olofsen, M.J.J.2
Verstraate, M.B.J.3
Quint, S.4
Heijmen, B.J.M.5
-
13
-
-
22144485867
-
Initial experience with megavoltage (MV) CT guidance for daily prostate alignments
-
K.M. Langen, Y. Zhang, and R.D. Andrews Initial experience with megavoltage (MV) CT guidance for daily prostate alignments Int J Radiat Oncol Biol Phys 62 2005 1517 1524
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.62
, pp. 1517-1524
-
-
Langen, K.M.1
Zhang, Y.2
Andrews, R.D.3
-
14
-
-
22444433075
-
Cone-beam-CT guided radiation therapy: Technical implementation
-
D. Létourneau, J.W. Wong, and M. Oldham Cone-beam-CT guided radiation therapy: technical implementation Radiother Oncol 75 2005 279 286
-
(2005)
Radiother Oncol
, vol.75
, pp. 279-286
-
-
Létourneau, D.1
Wong, J.W.2
Oldham, M.3
-
15
-
-
0842349454
-
Tracking moving organs in real time
-
M.J. Murphy Tracking moving organs in real time Semin Radiat Oncol 14 2004 91 100
-
(2004)
Semin Radiat Oncol
, vol.14
, pp. 91-100
-
-
Murphy, M.J.1
-
16
-
-
0034212293
-
Setup error in radiotherapy: On-line corrections using electronic kilovoltage and megavoltage radiographs
-
L. Pisani, D. Lockman, D. Jaffray, D. Yan, A. Martinez, and J. Wong Setup error in radiotherapy: on-line corrections using electronic kilovoltage and megavoltage radiographs Int J Radiat Oncol Biol Phys 47 2000 267 270
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.47
, pp. 267-270
-
-
Pisani, L.1
Lockman, D.2
Jaffray, D.3
Yan, D.4
Martinez, A.5
Wong, J.6
-
18
-
-
0033824313
-
Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
-
H. Shirato, S. Shimizu, and K. Kitamura Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor Int J Radiat Oncol Biol Phys 48 2000 435 442
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.48
, pp. 435-442
-
-
Shirato, H.1
Shimizu, S.2
Kitamura, K.3
-
19
-
-
0842284569
-
Intrafractional tumor motion: Lung and liver
-
H. Shirato, Y. Seppenwoolde, K. Kitamura, R. Onimura, and S. Shimizu Intrafractional tumor motion: lung and liver Semin Radiat Oncol 14 2004 10 18
-
(2004)
Semin Radiat Oncol
, vol.14
, pp. 10-18
-
-
Shirato, H.1
Seppenwoolde, Y.2
Kitamura, K.3
Onimura, R.4
Shimizu, S.5
-
20
-
-
27144520502
-
Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy
-
M.H.P. Smitsmans, J. deBois, and J.-J. Sonke Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy Int J Radiat Oncol Biol Phys 63 2005 975 984
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.63
, pp. 975-984
-
-
Smitsmans, M.H.P.1
Debois, J.2
Sonke, J.-J.3
-
22
-
-
0842306308
-
Errors and margins in radiation therapy
-
M. Van Herk Errors and margins in radiation therapy Semin Radiat Oncol 14 2005 52 64
-
(2005)
Semin Radiat Oncol
, vol.14
, pp. 52-64
-
-
Van Herk, M.1
-
23
-
-
20644450346
-
Computed tomography guided management of interfractional patient variation
-
D. Yan, D. Lockman, and A. Martinez Computed tomography guided management of interfractional patient variation Semin Radiat Oncol 15 2005 168 181
-
(2005)
Semin Radiat Oncol
, vol.15
, pp. 168-181
-
-
Yan, D.1
Lockman, D.2
Martinez, A.3
-
24
-
-
28944433290
-
Radiation therapy: Intensity modulated, image guided, biologically optimized and evidence based
-
S.M. Bentzen Radiation therapy: Intensity modulated, image guided, biologically optimized and evidence based Radiat Oncol 77 2005 227 230
-
(2005)
Radiat Oncol
, vol.77
, pp. 227-230
-
-
Bentzen, S.M.1
|