메뉴 건너뛰기




Volumn 68, Issue 5, 2012, Pages 1623-1631

Regional ventilation mapping of the rat lung using hyperpolarized 129Xe magnetic resonance imaging

Author keywords

helium; hyperpolarized; lung; ventilation; xenon

Indexed keywords

BIOLOGICAL ORGANS; HELIUM; PIXELS; RATS; VENTILATION; XENON;

EID: 84867858690     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24152     Document Type: Article
Times cited : (28)

References (25)
  • 6
    • 68149137721 scopus 로고    scopus 로고
    • A robust protocol for regional evaluation of methacholine challenge in mouse models of allergic asthma using hyperpolarized He-3 MRI
    • Thomas AC, Potts EN, Chen BT, Slipetz DM, Foster WM, Driehuys B,. A robust protocol for regional evaluation of methacholine challenge in mouse models of allergic asthma using hyperpolarized He-3 MRI. NMR Biomed 2009; 22: 502-515.
    • (2009) NMR Biomed , vol.22 , pp. 502-515
    • Thomas, A.C.1    Potts, E.N.2    Chen, B.T.3    Slipetz, D.M.4    Foster, W.M.5    Driehuys, B.6
  • 9
    • 0035143503 scopus 로고    scopus 로고
    • Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs
    • Marcucci C, Nyhan D, Simon BA,. Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs. J Appl Physiol 2001; 90: 421-430.
    • (2001) J Appl Physiol , vol.90 , pp. 421-430
    • Marcucci, C.1    Nyhan, D.2    Simon, B.A.3
  • 10
    • 35648947301 scopus 로고    scopus 로고
    • Micro-CT imaging of rat lung ventilation using continuous image acquisition during xenon gas contrast enhancement
    • Lam WW, Holdsworth DW, Du LY, Drangova M, McCormack DG, Santyr GE,. Micro-CT imaging of rat lung ventilation using continuous image acquisition during xenon gas contrast enhancement. J Appl Physiol 2007; 103: 1848-1856.
    • (2007) J Appl Physiol , vol.103 , pp. 1848-1856
    • Lam, W.W.1    Holdsworth, D.W.2    Du, L.Y.3    Drangova, M.4    McCormack, D.G.5    Santyr, G.E.6
  • 11
    • 80054052135 scopus 로고    scopus 로고
    • Comparison of hyperpolarized (3) He MRI with Xe-enhanced computed tomography imaging for ventilation mapping of rat lung
    • Santyr GE, Couch MJ, Lam WW, Ouriadov A, Drangova M, McCormack DG, Holdsworth DW,. Comparison of hyperpolarized (3) He MRI with Xe-enhanced computed tomography imaging for ventilation mapping of rat lung. NMR Biomed 2011; 24: 1073-1080.
    • (2011) NMR Biomed , vol.24 , pp. 1073-1080
    • Santyr, G.E.1    Couch, M.J.2    Lam, W.W.3    Ouriadov, A.4    Drangova, M.5    McCormack, D.G.6    Holdsworth, D.W.7
  • 15
    • 44949133164 scopus 로고    scopus 로고
    • Rapid and efficient mapping of regional ventilation in the rat lung using hyperpolarized 3He with flip angle variation for offset of rf and relaxation (FAVOR)
    • Santyr GE, Lam WW, Ouriadov A,. Rapid and efficient mapping of regional ventilation in the rat lung using hyperpolarized 3He with flip angle variation for offset of rf and relaxation (FAVOR). Magn Reson Med 2008; 59: 1304-1310.
    • (2008) Magn Reson Med , vol.59 , pp. 1304-1310
    • Santyr, G.E.1    Lam, W.W.2    Ouriadov, A.3
  • 16
    • 66549112796 scopus 로고    scopus 로고
    • Hyperpolarized noble gas magnetic resonance imaging of the animal lung: Approaches and applications
    • Santyr GE, Lam WW, Parra-Robles JM, Taves TM, Ouriadov AV,. Hyperpolarized noble gas magnetic resonance imaging of the animal lung: approaches and applications. J Appl Phys 2009; 105: 102004.
    • (2009) J Appl Phys , vol.105 , pp. 102004
    • Santyr, G.E.1    Lam, W.W.2    Parra-Robles, J.M.3    Taves, T.M.4    Ouriadov, A.V.5
  • 17
    • 0037408441 scopus 로고    scopus 로고
    • Imaging single mammalian cells with a 1.5 T clinical MRI scanner
    • Foster-Gareau P, Heyn C, Alejski A, Rutt BK,. Imaging single mammalian cells with a 1.5 T clinical MRI scanner. Magn Reson Med 2003; 49: 968-971.
    • (2003) Magn Reson Med , vol.49 , pp. 968-971
    • Foster-Gareau, P.1    Heyn, C.2    Alejski, A.3    Rutt, B.K.4
  • 19
    • 75149180414 scopus 로고    scopus 로고
    • Rapid 3-D mapping of hyperpolarized 3He spin-lattice relaxation times using variable flip angle gradient echo imaging with application to alveolar oxygen partial pressure measurement in rat lungs
    • Ouriadov AV, Lam WW, Santyr GE,. Rapid 3-D mapping of hyperpolarized 3He spin-lattice relaxation times using variable flip angle gradient echo imaging with application to alveolar oxygen partial pressure measurement in rat lungs. MAGMA 2009; 22: 309-318.
    • (2009) MAGMA , vol.22 , pp. 309-318
    • Ouriadov, A.V.1    Lam, W.W.2    Santyr, G.E.3
  • 21
    • 2542558666 scopus 로고    scopus 로고
    • Respiration
    • Krinke G.J. editor. San Diego, California, USA: Academic Press;
    • Schulz H, Muhle H,. Respiration. In:, Krinke GJ, editor. The laboratory rat. San Diego, California, USA: Academic Press; 2000. pp 323-344.
    • (2000) The Laboratory Rat , pp. 323-344
    • Schulz, H.1    Muhle, H.2
  • 23
    • 46849096514 scopus 로고    scopus 로고
    • In vivo MRI using real-time production of hyperpolarized Xe-129
    • Driehuys B, Pollaro J, Cofer GP,. In vivo MRI using real-time production of hyperpolarized Xe-129. Magn Reson Med 2008; 60: 14-20.
    • (2008) Magn Reson Med , vol.60 , pp. 14-20
    • Driehuys, B.1    Pollaro, J.2    Cofer, G.P.3
  • 25
    • 0037225618 scopus 로고    scopus 로고
    • Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI
    • Chen BT, Brau AC, Johnson GA,. Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI. Magn Reson Med 2003; 49: 78-88.
    • (2003) Magn Reson Med , vol.49 , pp. 78-88
    • Chen, B.T.1    Brau, A.C.2    Johnson, G.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.