메뉴 건너뛰기




Volumn 26, Issue 5, 2011, Pages 1011-1015

Accuracy of impressions for internal-connection implant prostheses with various divergent angles

Author keywords

Deformation of impression; Divergent angle; Implant impression; Implant level impressions; Impression accuracy; Internal connection implant

Indexed keywords

ARTICLE; DENTAL IMPRESSION; DENTAL PROCEDURE; ENDODONTICS; HUMAN; INSTRUMENTATION; MATERIALS TESTING; STANDARD; SURFACE PROPERTY; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 84867620880     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (28)

References (21)
  • 1
    • 0025412492 scopus 로고
    • An evaluation of impression techniques for osseointegrated implants
    • Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990; 63: 444-447.
    • (1990) J Prosthet Dent , vol.63 , pp. 444-447
    • Spector, M.R.1    Donovan, T.E.2    Nicholls, J.I.3
  • 5
    • 35648962421 scopus 로고    scopus 로고
    • Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models
    • Choi JH, Lim YJ, Yim SH, Kim CW. Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models. Int J Oral Maxillofac Implants 2007; 22: 761-768.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 761-768
    • Choi, J.H.1    Lim, Y.J.2    Yim, S.H.3    Kim, C.W.4
  • 6
    • 11444261183 scopus 로고    scopus 로고
    • Evaluation of transfer impressions for osseointegrated implants at various angulations
    • Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 2004; 13: 358-366.
    • (2004) Implant Dent , vol.13 , pp. 358-366
    • Assuncao, W.G.1    Filho, H.G.2    Zaniquelli, O.3
  • 7
    • 52249091557 scopus 로고    scopus 로고
    • The accuracy of implant impressions:A systematic review
    • Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions:A systematic review. J Prosthet Dent 2008; 100: 285-291.
    • (2008) J Prosthet Dent , vol.100 , pp. 285-291
    • Lee, H.1    So, J.S.2    Hochstedler, J.L.3    Ercoli, C.4
  • 8
    • 0035296004 scopus 로고    scopus 로고
    • A laboratory investigation of the accuracy of two impression techniques for single-tooth implants
    • Daoudi MF, Setchell DJ, Searson LJ. A laboratory investigation of the accuracy of two impression techniques for single-tooth implants. Int J Prosthodont 2001; 14: 152-158.
    • (2001) Int J Prosthodont , vol.14 , pp. 152-158
    • Daoudi, M.F.1    Setchell, D.J.2    Searson, L.J.3
  • 9
    • 0026311384 scopus 로고
    • Comparison of impression techniques for a five-implant mandibular model
    • Carr AB. Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991; 6: 448-455.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 448-455
    • Carr, A.B.1
  • 11
  • 12
    • 34250364800 scopus 로고    scopus 로고
    • Comparative analysis of 4 impression techniques for implants
    • Cabral LM, Guedes CG. Comparative analysis of 4 impression techniques for implants. Implant Dent 2007; 16: 187-194.
    • (2007) Implant Dent , vol.16 , pp. 187-194
    • Cabral, L.M.1    Guedes, C.G.2
  • 13
    • 58149186732 scopus 로고    scopus 로고
    • Prosthetic transfer impression accuracy evaluation for osseointegrated implants
    • Assuncao WG, Tabata LF, Cardoso A, Rocha EP, Gomes EA. Prosthetic transfer impression accuracy evaluation for osseointegrated implants. Implant Dent 2008; 17: 248-256.
    • (2008) Implant Dent , vol.17 , pp. 248-256
    • Assuncao, W.G.1    Tabata, L.F.2    Cardoso, A.3    Rocha, E.P.4    Gomes, E.A.5
  • 14
    • 0027031321 scopus 로고
    • Comparison of impression techniques for a two-implant 15-degree divergent model
    • Carr AB. Comparison of impression techniques for a two-implant 15-degree divergent model. Int J Oral Maxillofac Implants 1992; 7: 468-475.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 468-475
    • Carr, A.B.1
  • 15
    • 34347329149 scopus 로고    scopus 로고
    • Accuracy of two impression techniques with angulated implants
    • Conrad HJ, Pesun IJ, DeLong R, Hodges JS. Accuracy of two impression techniques with angulated implants. J Prosthet Dent 2007; 97: 349-356.
    • (2007) J Prosthet Dent , vol.97 , pp. 349-356
    • Conrad, H.J.1    Pesun, I.J.2    DeLong, R.3    Hodges, J.S.4
  • 19
    • 0034185646 scopus 로고    scopus 로고
    • Evaluation of impression accuracy for osseointegrated implant supported superstructures
    • Herbst D, Nel JC, Driessen CH, Becker PJ. Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 2000; 83: 555-561.
    • (2000) J Prosthet Dent , vol.83 , pp. 555-561
    • Herbst, D.1    Nel, J.C.2    Driessen, C.H.3    Becker, P.J.4
  • 20
    • 0034146316 scopus 로고    scopus 로고
    • Comparison of impression materials for direct multiimplant impressions
    • Wee AG. Comparison of impression materials for direct multiimplant impressions. J Prosthet Dent 2000; 83: 323-331.
    • (2000) J Prosthet Dent , vol.83 , pp. 323-331
    • Wee, A.G.1
  • 21
    • 40849137885 scopus 로고    scopus 로고
    • Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection
    • Wenz HJ, Hertrampf K. Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implants 2008; 23: 39-47.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 39-47
    • Wenz, H.J.1    Hertrampf, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.