메뉴 건너뛰기




Volumn 22, Issue 5, 2007, Pages 761-768

Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models

Author keywords

Implant divergence; Implant level impression; Internal connection implant; Strain gauge

Indexed keywords

ACRYLIC ACID RESIN; BIOMEDICAL AND DENTAL MATERIALS; POLYVINYL DERIVATIVE; SILOXANE; UNCLASSIFIED DRUG; VINYL POLYSILOXANE;

EID: 35648962421     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (88)

References (41)
  • 1
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Bränemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Bränemark, P.-I.4
  • 2
    • 0020823258 scopus 로고
    • Osseointegration and its experimental background
    • Brånemark P-I. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410.
    • (1983) J Prosthet Dent , vol.50 , pp. 399-410
    • Brånemark, P.-I.1
  • 3
    • 0025412014 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants:TheToronto study. Part I: Surgical results
    • Zarb GA, Schmitt A.The longitudinal clinical effectiveness of osseointegrated dental implants:TheToronto study. Part I: Surgical results. J Prosthet Dent 1990;63:451-457.
    • (1990) J Prosthet Dent , vol.63 , pp. 451-457
    • Zarb, G.A.1    Schmitt, A.2
  • 4
    • 0025456734 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants:TheToronto Study. Part II: The prosthetic results
    • Zarb GA, Schmitt A.The longitudinal clinical effectiveness of osseointegrated dental implants:TheToronto Study. Part II: The prosthetic results. J Prosthet Dent 1990;64:53-61.
    • (1990) J Prosthet Dent , vol.64 , pp. 53-61
    • Zarb, G.A.1    Schmitt, A.2
  • 5
    • 0020804122 scopus 로고
    • Maxillary fixed prostheses on osseointegrated dental implants
    • Lundqvist S, Carlsson GE. Maxillary fixed prostheses on osseointegrated dental implants. J Prosthet Dent 1983;50:262-270.
    • (1983) J Prosthet Dent , vol.50 , pp. 262-270
    • Lundqvist, S.1    Carlsson, G.E.2
  • 6
    • 0025412492 scopus 로고
    • An evaluation of impression techniques for osseointegrated implants
    • Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990;63:444-447.
    • (1990) J Prosthet Dent , vol.63 , pp. 444-447
    • Spector, M.R.1    Donovan, T.E.2    Nicholls, J.I.3
  • 7
    • 75549100525 scopus 로고    scopus 로고
    • Rudd KD, O'Leary TJ, Stumpf AJ Jr. Horizontal Tooth Mobility In Carefully Screened Subjects. Techn Docum Rep Sam-Tdr-64-12.Tech Doc Rep U S Air Force Syst Command Electron Syst Div 1964;94:1-6.
    • Rudd KD, O'Leary TJ, Stumpf AJ Jr. Horizontal Tooth Mobility In Carefully Screened Subjects. Techn Docum Rep Sam-Tdr-64-12.Tech Doc Rep U S Air Force Syst Command Electron Syst Div 1964;94:1-6.
  • 8
    • 35648962835 scopus 로고    scopus 로고
    • Sekine H.Komiyama Y, Hotta H.Yoshida K. Mobility characteristics and tactile sensitivity of osseointegrated fixture-supporting systems. In: van Steenberghe D (ed).Tissue Integration in Oral Maxillofacial Reconstruction. Amsterdam: Excerpta Medica, 1986:326-332.
    • Sekine H.Komiyama Y, Hotta H.Yoshida K. Mobility characteristics and tactile sensitivity of osseointegrated fixture-supporting systems. In: van Steenberghe D (ed).Tissue Integration in Oral Maxillofacial Reconstruction. Amsterdam: Excerpta Medica, 1986:326-332.
  • 9
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in fullarch fixed prostheses supported by osseointegrated implants after 5 years
    • KallusT, Bessing C. Loose gold screws frequently occur in fullarch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9:169-178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 10
    • 0030277405 scopus 로고    scopus 로고
    • The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit
    • Carr AB, Gerard DA, Larsen PE.The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. J Prosthet Dent 1996,76:500-509.
    • (1996) J Prosthet Dent , vol.76 , pp. 500-509
    • Carr, A.B.1    Gerard, D.A.2    Larsen, P.E.3
  • 11
    • 0030098964 scopus 로고    scopus 로고
    • The effect of implant/abutment hexagonal misfit on screw joint stability
    • Binon PP.The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996;9:149-160.
    • (1996) Int J Prosthodont , vol.9 , pp. 149-160
    • Binon, P.P.1
  • 12
    • 0030155422 scopus 로고    scopus 로고
    • Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys
    • Isidor F. Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clin Oral Implants Res 1996;7:143-152.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 143-152
    • Isidor, F.1
  • 13
    • 0031061799 scopus 로고    scopus 로고
    • Histological evaluation of peri-implant bone at Implants subjected to occlusal overload or plaque accumulation
    • Isidor F. Histological evaluation of peri-implant bone at Implants subjected to occlusal overload or plaque accumulation. Clin Oral Implants Res 1997;8:1-9.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 1-9
    • Isidor, F.1
  • 14
    • 0032060817 scopus 로고    scopus 로고
    • Mobility assessment with the Periotest system in relation to histologic findings of oral implants
    • Isidor F. Mobility assessment with the Periotest system in relation to histologic findings of oral implants. Int J Oral Maxillofac Implants 1998;13:377-383.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 377-383
    • Isidor, F.1
  • 15
    • 0035223781 scopus 로고    scopus 로고
    • The significance of passive framework fit in implant prosthodontics: Current status
    • Sahin S,Cehreli MC.The significance of passive framework fit in implant prosthodontics: Current status. Implant Dent 2001;10:85-92.
    • (2001) Implant Dent , vol.10 , pp. 85-92
    • Sahin, S.1    Cehreli, M.C.2
  • 17
    • 0003919966 scopus 로고
    • Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry.Chicago:Quintessence
    • Brånemark P-I,Zarb G, Albrektsson T. Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry.Chicago:Quintessence, 1985:11-12, 253-257.
    • (1985)
    • Brånemark, P.-I.1    Zarb, G.2    Albrektsson, T.3
  • 20
    • 7444265288 scopus 로고    scopus 로고
    • An evaluation of impression techniques for multiple internal connection implant prostheses
    • Vigolo P, Fonzi F, Majzoub Z, Cordioli G. An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 2004;92:470-476.
    • (2004) J Prosthet Dent , vol.92 , pp. 470-476
    • Vigolo, P.1    Fonzi, F.2    Majzoub, Z.3    Cordioli, G.4
  • 21
    • 0025622921 scopus 로고
    • The accuracy of implant master casts constructed from transfer impressions
    • Humphries RM, Yaman P, Bloem TJ.The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990;5:331-336.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 331-336
    • Humphries, R.M.1    Yaman, P.2    Bloem, T.J.3
  • 22
    • 0027615809 scopus 로고
    • A comparative analysis of the accuracy of implant transfer techniques
    • Hsu CC, Millstein PL, Stein RS. A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 1993;69:588-593.
    • (1993) J Prosthet Dent , vol.69 , pp. 588-593
    • Hsu, C.C.1    Millstein, P.L.2    Stein, R.S.3
  • 24
    • 0034185646 scopus 로고    scopus 로고
    • Evaluation of impression accuracy for osseointegrated implant supported superstructures
    • Herbst D, Nel JC, Driessen CH, Becker PJ. Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 2000;83:555-561.
    • (2000) J Prosthet Dent , vol.83 , pp. 555-561
    • Herbst, D.1    Nel, J.C.2    Driessen, C.H.3    Becker, P.J.4
  • 25
    • 0027597615 scopus 로고
    • Evaluation of three impression techniques for osseointegrated oral implants
    • Inturregui JA, Aquilino SA, Ryther JS, Lund PS. Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 1993;69:503-509.
    • (1993) J Prosthet Dent , vol.69 , pp. 503-509
    • Inturregui, J.A.1    Aquilino, S.A.2    Ryther, J.S.3    Lund, P.S.4
  • 26
    • 0030641241 scopus 로고    scopus 로고
    • A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system
    • Burawi G, Houston F, Byrne D, Claffey N. A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 1997;77:68-75.
    • (1997) J Prosthet Dent , vol.77 , pp. 68-75
    • Burawi, G.1    Houston, F.2    Byrne, D.3    Claffey, N.4
  • 27
    • 0036982599 scopus 로고    scopus 로고
    • The suitability of head-of-implant and conventional abutment impression techniques for implant-retained 3 unit bridges: An in vitro study
    • Bartlett DW, Greenwood R, Howe L.The suitability of head-of-implant and conventional abutment impression techniques for implant-retained 3 unit bridges: An in vitro study. Eur J Prosthodont Restorative Dent 2002;10:163-166.
    • (2002) Eur J Prosthodont Restorative Dent , vol.10 , pp. 163-166
    • Bartlett, D.W.1    Greenwood, R.2    Howe, L.3
  • 28
    • 0038727298 scopus 로고    scopus 로고
    • Vigolo P, Majzoub Z.Cordioli G. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 2003;89:186-192.
    • Vigolo P, Majzoub Z.Cordioli G. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 2003;89:186-192.
  • 29
    • 0033218582 scopus 로고    scopus 로고
    • Accuracy of implant impression splinted techniques: Effect of splinting material
    • Assif D, Nissan J, Varsano I, Singer A. Accuracy of implant impression splinted techniques: Effect of splinting material. Int J Oral Maxillofac Implants 1999;14:885-888.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 885-888
    • Assif, D.1    Nissan, J.2    Varsano, I.3    Singer, A.4
  • 31
    • 0022103286 scopus 로고
    • Dimensional change of acrylic resin tray materials
    • Goldfogel M, Harvey WL,Winter D. Dimensional change of acrylic resin tray materials. J Prosthet Dent 1985;54:284-286.
    • (1985) J Prosthet Dent , vol.54 , pp. 284-286
    • Goldfogel, M.1    Harvey, W.L.2    Winter, D.3
  • 33
    • 0028455733 scopus 로고
    • A modified impression technique for implant-supported restoration
    • Assif D, Marshak B, Nissan J. A modified impression technique for implant-supported restoration. J Prosthet Dent 1994;71:589-591.
    • (1994) J Prosthet Dent , vol.71 , pp. 589-591
    • Assif, D.1    Marshak, B.2    Nissan, J.3
  • 34
    • 0016998151 scopus 로고
    • The bonding properties of elastomer tray adhesives
    • Davis GB, Moser JB, Brinsden GI. The bonding properties of elastomer tray adhesives. J Prosthet Dent 1976;36:278-285.
    • (1976) J Prosthet Dent , vol.36 , pp. 278-285
    • Davis, G.B.1    Moser, J.B.2    Brinsden, G.I.3
  • 35
    • 0017484453 scopus 로고
    • 19 for Non-aqueous, Elastomeric Dental Impression Materials
    • Revised American Dental Association Specification no
    • Revised American Dental Association Specification no. 19 for Non-aqueous, Elastomeric Dental Impression Materials. J Am Dent Assoc 1977;94:733-741.
    • (1977) J Am Dent Assoc , vol.94 , pp. 733-741
  • 37
    • 0035406111 scopus 로고    scopus 로고
    • Nissan J, Gross M.Shifman A, Assif D. Stress levels for well-fitting implant superstructures as a function of tightening force levels, tightening sequence, and different operators. J Prosthet Dent 2001;86:20-23.
    • Nissan J, Gross M.Shifman A, Assif D. Stress levels for well-fitting implant superstructures as a function of tightening force levels, tightening sequence, and different operators. J Prosthet Dent 2001;86:20-23.
  • 38
    • 2342435354 scopus 로고
    • The accuracy of implant impression procedures [abstract 1065]
    • Fenton A, Assif D, Zarb G, Schmitt A.The accuracy of implant impression procedures [abstract 1065], J Dent Res 1991;70:399.
    • (1991) J Dent Res , vol.70 , pp. 399
    • Fenton, A.1    Assif, D.2    Zarb, G.3    Schmitt, A.4
  • 39
    • 0026311384 scopus 로고
    • Comparison of impression techniques for a five-implant mandibular model
    • Carr AB. Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991;6:448-455.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 448-455
    • Carr, A.B.1
  • 41
    • 0027031321 scopus 로고
    • Comparison of impression techniques for a two-implant 15-degree divergent model
    • Carr AB. Comparison of impression techniques for a two-implant 15-degree divergent model. Int J Oral Maxillofac Implants 1992;7:468-475.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 468-475
    • Carr, A.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.