메뉴 건너뛰기




Volumn 414, Issue , 2012, Pages 234-240

Systematic monitoring of standardization and harmonization status with commutable EQA-samples—Five year experience from the Netherlands

Author keywords

Commutable EQA materials; Desirable bias and imprecision; Harmonization; Standardization; Test equivalence; Total allowable error

Indexed keywords

CREATININE; ELECTROLYTE; ENZYME;

EID: 84867595672     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2012.09.027     Document Type: Article
Times cited : (40)

References (21)
  • 1
    • 0034257330 scopus 로고    scopus 로고
    • The quest for comparability: Calibration 2000
    • Jansen, R.T.P., The quest for comparability: Calibration 2000. Accredit Qual Assur 5 (2000), 363–366.
    • (2000) Accredit Qual Assur , vol.5 , pp. 363-366
    • Jansen, R.T.P.1
  • 2
    • 0033636288 scopus 로고    scopus 로고
    • Implementation of reference systems in laboratory medicine
    • Müller, M.M., Implementation of reference systems in laboratory medicine. Clin Chem 46 (2000), 1907–1909.
    • (2000) Clin Chem , vol.46 , pp. 1907-1909
    • Müller, M.M.1
  • 3
    • 79961074096 scopus 로고    scopus 로고
    • Roadmap for harmonization of clinical laboratory measurement procedures
    • Miller, W.G., Myers, G.L., Gantzer, M.L., et al. Roadmap for harmonization of clinical laboratory measurement procedures. Clin Chem 57 (2011), 1108–1117.
    • (2011) Clin Chem , vol.57 , pp. 1108-1117
    • Miller, W.G.1    Myers, G.L.2    Gantzer, M.L.3
  • 4
    • 82755167810 scopus 로고    scopus 로고
    • Proficiency testing/external quality assessment: current challenges and future directions
    • Miller, W.G., Jones, G.R.D., Horowitz, G.L., Weykamp, C., Proficiency testing/external quality assessment: current challenges and future directions. Clin Chem 57 (2011), 1670–1680.
    • (2011) Clin Chem , vol.57 , pp. 1670-1680
    • Miller, W.G.1    Jones, G.R.D.2    Horowitz, G.L.3    Weykamp, C.4
  • 5
    • 0033392528 scopus 로고    scopus 로고
    • Consensus agreement conference on strategies to set global quality specifications in laboratory medicine. Stockholm. April 24–26, 1999
    • Kallner, A., McQueen, M., Heuck, C., Consensus agreement conference on strategies to set global quality specifications in laboratory medicine. Stockholm. April 24–26, 1999. Scand J Clin Lab Invest 59 (1999), 475–476.
    • (1999) Scand J Clin Lab Invest , vol.59 , pp. 475-476
    • Kallner, A.1    McQueen, M.2    Heuck, C.3
  • 6
    • 84860447264 scopus 로고    scopus 로고
    • Minimum analytical quality specifications of inter-laboratory comparisons: agreement among Spanish EQAP organizers
    • Ricós, C., Ramón, F., Salas, A., Buño, A., Calafell, R., Morancho, J., Minimum analytical quality specifications of inter-laboratory comparisons: agreement among Spanish EQAP organizers. Clin Chem Lab Med 50 (2012), 455–461.
    • (2012) Clin Chem Lab Med , vol.50 , pp. 455-461
    • Ricós, C.1    Ramón, F.2    Salas, A.3    Buño, A.4    Calafell, R.5    Morancho, J.6
  • 7
    • 85072787625 scopus 로고    scopus 로고
    • Allowable limits of performance—statistical basis and implementation
    • Gill, J., Allowable limits of performance—statistical basis and implementation. Pathology 43:S1 (2011), S17–S20.
    • (2011) Pathology , vol.43 , Issue.S1 , pp. S17-S20
    • Gill, J.1
  • 9
    • 84888889422 scopus 로고    scopus 로고
    • A nationwide split patient and control sample experiment to check the commutability of control samples [Abstract]
    • (abstract T250)
    • Baadenhuijsen, H., Jansen, R.T.P., Weykamp, C.W., Steigstra, H., Kuypers, A.W.H.M., A nationwide split patient and control sample experiment to check the commutability of control samples [Abstract]. Clin Chem Lab Med, 37, 1999, S279 (abstract T250).
    • (1999) Clin Chem Lab Med , vol.37 , pp. S279
    • Baadenhuijsen, H.1    Jansen, R.T.P.2    Weykamp, C.W.3    Steigstra, H.4    Kuypers, A.W.H.M.5
  • 10
    • 0034011641 scopus 로고    scopus 로고
    • A model for harmonization of routine clinical chemistry results between clinical laboratories
    • Baadenhuijsen, H., Scholten, R., Willems, H.L., Weykamp, C.W., Jansen, R.T.P., A model for harmonization of routine clinical chemistry results between clinical laboratories. Ann Clin Biochem 37 (2000), 330–337.
    • (2000) Ann Clin Biochem , vol.37 , pp. 330-337
    • Baadenhuijsen, H.1    Scholten, R.2    Willems, H.L.3    Weykamp, C.W.4    Jansen, R.T.P.5
  • 12
    • 33746915004 scopus 로고    scopus 로고
    • Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum. An international study in the EC4 framework of the Calibration 2000 project
    • Jansen, R., Schumann, G., Baadenhuijsen, H., et al. Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum. An international study in the EC4 framework of the Calibration 2000 project. Clin Chim Acta 368 (2006), 160–167.
    • (2006) Clin Chim Acta , vol.368 , pp. 160-167
    • Jansen, R.1    Schumann, G.2    Baadenhuijsen, H.3
  • 13
    • 33644799923 scopus 로고    scopus 로고
    • Harmonisation of factor VIII:C assay results: study within the framework of the Dutch project ‘Calibration 2000’
    • van den Besselaar, A.M.H.P., Haas, F.J.L.M., Kuypers, A.W.H.M., Harmonisation of factor VIII:C assay results: study within the framework of the Dutch project ‘Calibration 2000’. Br J Haematol 132 (2006), 75–79.
    • (2006) Br J Haematol , vol.132 , pp. 75-79
    • van den Besselaar, A.M.H.P.1    Haas, F.J.L.M.2    Kuypers, A.W.H.M.3
  • 14
    • 70350230180 scopus 로고    scopus 로고
    • Harmonization of fibrinogen assay results: study within the framework of the Dutch project ‘Calibration 2000’
    • van den Besselaar, A.M.H.P., Haas, F.J.L.M., van der Graaf, F., Kuypers, A.W.H.M., Harmonization of fibrinogen assay results: study within the framework of the Dutch project ‘Calibration 2000’. Int J Lab Hematol 3 (2009), 513–520.
    • (2009) Int J Lab Hematol , vol.3 , pp. 513-520
    • van den Besselaar, A.M.H.P.1    Haas, F.J.L.M.2    van der Graaf, F.3    Kuypers, A.W.H.M.4
  • 16
    • 0036721593 scopus 로고    scopus 로고
    • Commutability assessment of potential reference materials using a multicenter split-patient-sample between-field-methods (twin-study) design: study within the framework of the Dutch project “Calibration 2000”
    • Baadenhuijsen, H., Steigstra, H., Cobbaert, C., Kuypers, A., Weykamp, C., Jansen, R., Commutability assessment of potential reference materials using a multicenter split-patient-sample between-field-methods (twin-study) design: study within the framework of the Dutch project “Calibration 2000”. Clin Chem 48 (2002), 1520–1525.
    • (2002) Clin Chem , vol.48 , pp. 1520-1525
    • Baadenhuijsen, H.1    Steigstra, H.2    Cobbaert, C.3    Kuypers, A.4    Weykamp, C.5    Jansen, R.6
  • 18
    • 17044380940 scopus 로고    scopus 로고
    • External quality assessment in the Netherlands: time to introduce commutable survey specimens. Lessons from the Dutch “Calibration 2000” project
    • Baadenhuijsen, H., Kuypers, A., Weykamp, C., Cobbaert, C., Jansen, R., External quality assessment in the Netherlands: time to introduce commutable survey specimens. Lessons from the Dutch “Calibration 2000” project. Clin Chem Lab Med 43 (2005), 304–307.
    • (2005) Clin Chem Lab Med , vol.43 , pp. 304-307
    • Baadenhuijsen, H.1    Kuypers, A.2    Weykamp, C.3    Cobbaert, C.4    Jansen, R.5
  • 19
    • 0033374189 scopus 로고    scopus 로고
    • General strategies to set quality specifications for reliability performance characteristics
    • Fraser, C.G., General strategies to set quality specifications for reliability performance characteristics. Scand J Clin Lab Invest 59 (1999), 487–490.
    • (1999) Scand J Clin Lab Invest , vol.59 , pp. 487-490
    • Fraser, C.G.1
  • 20
    • 0033369894 scopus 로고    scopus 로고
    • Current databases on biologic variation: pros, cons and progress
    • Ricos, C., Alvarez, V., Cava, F., et al. Current databases on biologic variation: pros, cons and progress. Scand J Clin Lab Invest 59 (1999), 491–500.
    • (1999) Scand J Clin Lab Invest , vol.59 , pp. 491-500
    • Ricos, C.1    Alvarez, V.2    Cava, F.3
  • 21
    • 62149102286 scopus 로고    scopus 로고
    • Prime time for enzymatic creatinine methods in pediatrics
    • Cobbaert, C., Baadenhuijsen, H., Weykamp, C.W., Prime time for enzymatic creatinine methods in pediatrics. Clin Chem 55 (2009), 549–558.
    • (2009) Clin Chem , vol.55 , pp. 549-558
    • Cobbaert, C.1    Baadenhuijsen, H.2    Weykamp, C.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.