메뉴 건너뛰기




Volumn 132, Issue 1, 2006, Pages 75-79

Harmonisation of factor VIII:C assay results: Study within the framework of the Dutch project 'Calibration 2000'

Author keywords

Calibration; Commutability; External quality assessment; Factor VIII:C assay; Harmonisation

Indexed keywords

BLOOD CLOTTING FACTOR 8;

EID: 33644799923     PISSN: 00071048     EISSN: 13652141     Source Type: Journal    
DOI: 10.1111/j.1365-2141.2005.05829.x     Document Type: Article
Times cited : (12)

References (10)
  • 1
    • 0026702675 scopus 로고
    • Factors affecting the performance of Factor VIII coagulant activity assays. Results of proficiency surveys of the College of American Pathologists
    • Arkin C.F. Bovill E.G. Brandt J.T. Rock W.A. Triplett D.A. 1992 Factors affecting the performance of Factor VIII coagulant activity assays. Results of proficiency surveys of the College of American Pathologists Archives of Pathology and Laboratory Medicine 116 908 915
    • (1992) Archives of Pathology and Laboratory Medicine , vol.116 , pp. 908-915
    • Arkin, C.F.1    Bovill, E.G.2    Brandt, J.T.3    Rock, W.A.4    Triplett, D.A.5
  • 2
    • 0036721593 scopus 로고    scopus 로고
    • Commutability assessment of potential reference materials using a multicenter split-patient-sample between-field-methods (twin-study) design: Study within the framework of the Dutch project 'Calibration 2000'
    • Baadenhuijsen H. Steigstra H. Cobbaert C. Kuypers A. Weykamp C. Jansen R. 2002 Commutability assessment of potential reference materials using a multicenter split-patient-sample between-field-methods (twin-study) design: study within the framework of the Dutch project 'Calibration 2000' Clinical Chemistry 48 1520 1525
    • (2002) Clinical Chemistry , vol.48 , pp. 1520-1525
    • Baadenhuijsen, H.1    Steigstra, H.2    Cobbaert, C.3    Kuypers, A.4    Weykamp, C.5    Jansen, R.6
  • 3
    • 0035073745 scopus 로고    scopus 로고
    • Standardisation of Factor VIII and von Willebrand Factor in plasma: Calibration of the 4th International Standard (97/586)
    • Hubbard A.R. Rigsby P. Barrowcliffe T.W. 2001 Standardisation of Factor VIII and von Willebrand Factor in plasma: Calibration of the 4th International Standard (97/586) Thrombosis and Haemostasis 85 634 638
    • (2001) Thrombosis and Haemostasis , vol.85 , pp. 634-638
    • Hubbard, A.R.1    Rigsby, P.2    Barrowcliffe, T.W.3
  • 5
    • 0037212728 scopus 로고    scopus 로고
    • Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes
    • Miller W.G. 2003 Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes Clinica Chimica Acta 327 25 37
    • (2003) Clinica Chimica Acta , vol.327 , pp. 25-37
    • Miller, W.G.1
  • 6
  • 7
    • 0021752980 scopus 로고
    • Methodology of the one-stage assay of factor VIII (VIII:C)
    • Over J. 1984 Methodology of the one-stage assay of factor VIII (VIII:C) Scandinavian Journal of Haematology Supplement 41 13 24
    • (1984) Scandinavian Journal of Haematology Supplement , vol.41 , pp. 13-24
    • Over, J.1
  • 8
    • 0031668611 scopus 로고    scopus 로고
    • Laboratory diagnosis of hereditary bleeding disorders: External quality assessment
    • Preston F.E. 1998 Laboratory diagnosis of hereditary bleeding disorders: external quality assessment Haemophilia 4 Suppl 2 12 18
    • (1998) Haemophilia , vol.4 , Issue.SUPPL. 2 , pp. 12-18
    • Preston, F.E.1
  • 9
    • 0031830492 scopus 로고    scopus 로고
    • Quality control and factor VIII assays
    • Preston F.E. Kitchen S. 1998 Quality control and factor VIII assays Haemophilia 4 651 653
    • (1998) Haemophilia , vol.4 , pp. 651-653
    • Preston, F.E.1    Kitchen, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.