메뉴 건너뛰기




Volumn 31, Issue 11, 2012, Pages 1223-1229

Two axial-flow Synergy Micro-Pumps as a biventricular assist device in an ovine animal model

Author keywords

BiVAD; biventricular support; CircuLite Synergy Micro Pump; left ventricular assist device; right ventricular assist device

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; ASCENDING AORTA; BIVENTRICULAR ASSIST DEVICE; BLOOD VOLUME; END TO END ANASTOMOSIS; FEASIBILITY STUDY; FEMALE; HEART LEFT ATRIUM; HEART LEFT VENTRICLE; HEART RIGHT VENTRICLE; HEART VENTRICLE FIBRILLATION; HEMODYNAMICS; LEFT VENTRICULAR ASSIST DEVICE; NONHUMAN; PRESSURE GRADIENT; PRIORITY JOURNAL; PULMONARY ARTERY; RIGHT VENTRICULAR ASSIST DEVICE; SHEEP; STERNOTOMY;

EID: 84867574206     PISSN: 10532498     EISSN: 15573117     Source Type: Journal    
DOI: 10.1016/j.healun.2012.08.008     Document Type: Article
Times cited : (18)

References (44)
  • 1
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • M.S. Slaughter, J.G. Rogers, C.A. Milano Advanced heart failure treated with continuous-flow left ventricular assist device N Engl J Med 361 2009 2241 2251
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 2
    • 67650093608 scopus 로고    scopus 로고
    • Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device
    • F.D. Pagani, L.W. Miller, S.D. Russell Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device J Am Coll Cardiol 54 2009 312 321
    • (2009) J Am Coll Cardiol , vol.54 , pp. 312-321
    • Pagani, F.D.1    Miller, L.W.2    Russell, S.D.3
  • 3
    • 84855827670 scopus 로고    scopus 로고
    • Implantation of a centrifugal pump as a left ventricular assist device through a novel, minimized approach: Upper hemisternotomy combined with anterolateral thoracotomy
    • J.D. Schmitto, U. Molitoris, A. Haverich, M. Strueber Implantation of a centrifugal pump as a left ventricular assist device through a novel, minimized approach: upper hemisternotomy combined with anterolateral thoracotomy J Thorac Cardiovasc Surg 143 2012 511 513
    • (2012) J Thorac Cardiovasc Surg , vol.143 , pp. 511-513
    • Schmitto, J.D.1    Molitoris, U.2    Haverich, A.3    Strueber, M.4
  • 4
    • 78049287188 scopus 로고    scopus 로고
    • Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial
    • G.M. Wieselthaler, O. Driscoll, P. Jansz, A. Khaghani, M. Strueber Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial J Heart Lung Transplant 29 2010 1218 1225
    • (2010) J Heart Lung Transplant , vol.29 , pp. 1218-1225
    • Wieselthaler, G.M.1    Driscoll, O.2    Jansz, P.3    Khaghani, A.4    Strueber, M.5
  • 6
    • 83455262979 scopus 로고    scopus 로고
    • Implantation of the HeartWare left ventricular assist device
    • M.S. Slaughter Implantation of the HeartWare left ventricular assist device Semin Thorac Cardiovasc Surg 23 2011 245 247
    • (2011) Semin Thorac Cardiovasc Surg , vol.23 , pp. 245-247
    • Slaughter, M.S.1
  • 8
    • 79951771915 scopus 로고    scopus 로고
    • Minimally invasive aortic valve replacement: How does this perform in high-risk patients?
    • J.D. Schmitto, F.W. Mohr, L.H. Cohn Minimally invasive aortic valve replacement: how does this perform in high-risk patients? Curr Opin Cardiol 26 2011 118 122
    • (2011) Curr Opin Cardiol , vol.26 , pp. 118-122
    • Schmitto, J.D.1    Mohr, F.W.2    Cohn, L.H.3
  • 9
    • 84855386659 scopus 로고    scopus 로고
    • Past, present, and future of minimally invasive mitral valve surgery
    • J.D. Schmitto, S.A. Mokashi, L.H. Cohn Past, present, and future of minimally invasive mitral valve surgery J Heart Valve Dis 20 2011 493 498
    • (2011) J Heart Valve Dis , vol.20 , pp. 493-498
    • Schmitto, J.D.1    Mokashi, S.A.2    Cohn, L.H.3
  • 10
    • 84863393498 scopus 로고    scopus 로고
    • The Fourth INTERMACS Annual Report: 4,000 implants and counting
    • J.K. Kirklin, D.C. Naftel, R.L. Kormos The Fourth INTERMACS Annual Report: 4,000 implants and counting J Heart Lung Transplant 31 2012 117 126
    • (2012) J Heart Lung Transplant , vol.31 , pp. 117-126
    • Kirklin, J.K.1    Naftel, D.C.2    Kormos, R.L.3
  • 11
    • 0037167691 scopus 로고    scopus 로고
    • Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: Analysis of 245 patients
    • Y. Ochiai, P.M. McCarthy, N.G. Smedira Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: analysis of 245 patients Circulation 106 12 Suppl 1 2002 I198 I202
    • (2002) Circulation , vol.106 , Issue.12 SUPPL. 1
    • Ochiai, Y.1    McCarthy, P.M.2    Smedira, N.G.3
  • 12
    • 84856495532 scopus 로고    scopus 로고
    • Decision tree for adjuvant right ventricular support in patients receiving a left ventricular assist device
    • Y. Wang, M.A. Simon, P. Bonde Decision tree for adjuvant right ventricular support in patients receiving a left ventricular assist device J Heart Lung Transplant 31 2012 140 149
    • (2012) J Heart Lung Transplant , vol.31 , pp. 140-149
    • Wang, Y.1    Simon, M.A.2    Bonde, P.3
  • 13
    • 77949490707 scopus 로고    scopus 로고
    • Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomes
    • R.L. Kormos, J.J. Teuteberg, F.D. Pagani Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes J Thorac Cardiovasc Surg 139 2010 1316 1324
    • (2010) J Thorac Cardiovasc Surg , vol.139 , pp. 1316-1324
    • Kormos, R.L.1    Teuteberg, J.J.2    Pagani, F.D.3
  • 14
    • 57049174043 scopus 로고    scopus 로고
    • Risk score derived from pre-operative data analysis predicts the need for biventricular mechanical circulatory support
    • 3rd
    • J.R. Fitzpatrick 3rd, J.R. Frederick, V.M. Hsu Risk score derived from pre-operative data analysis predicts the need for biventricular mechanical circulatory support J Heart Lung Transplant 27 2008 1286 1292
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1286-1292
    • Fitzpatrick, J.R.1    Frederick, J.R.2    Hsu, V.M.3
  • 15
    • 44049094013 scopus 로고    scopus 로고
    • The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates
    • J.C. Matthews, T.M. Koelling, F.D. Pagani, K.D. Aaronson The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates J Am Coll Cardiol 51 2008 2163 2172
    • (2008) J Am Coll Cardiol , vol.51 , pp. 2163-2172
    • Matthews, J.C.1    Koelling, T.M.2    Pagani, F.D.3    Aaronson, K.D.4
  • 16
    • 57049100424 scopus 로고    scopus 로고
    • Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device
    • E.V. Potapov, A. Stepanenko, M. Dandel Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device J Heart Lung Transplant 27 2008 1275 1281
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1275-1281
    • Potapov, E.V.1    Stepanenko, A.2    Dandel, M.3
  • 17
    • 84855859973 scopus 로고    scopus 로고
    • Usefulness of two-dimensional echocardiographic parameters of the left side of the heart to predict right ventricular failure after left ventricular assist device implantation
    • T.S. Kato, M. Farr, P.C. Schulze Usefulness of two-dimensional echocardiographic parameters of the left side of the heart to predict right ventricular failure after left ventricular assist device implantation Am J Cardiol 109 2012 246 251
    • (2012) Am J Cardiol , vol.109 , pp. 246-251
    • Kato, T.S.1    Farr, M.2    Schulze, P.C.3
  • 19
    • 4143052707 scopus 로고    scopus 로고
    • Cardiac replacement with a total artificial heart as a bridge to transplantation
    • J.G. Copeland, R.G. Smith, F.A. Arabia Cardiac replacement with a total artificial heart as a bridge to transplantation N Engl J Med 351 2004 859 867
    • (2004) N Engl J Med , vol.351 , pp. 859-867
    • Copeland, J.G.1    Smith, R.G.2    Arabia, F.A.3
  • 20
    • 33644797321 scopus 로고    scopus 로고
    • Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients
    • L. Dong, J.A. Wang, C.Y. Jiang Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients J Zhejiang Univ Sci B 6 2005 1157 1162
    • (2005) J Zhejiang Univ Sci B , vol.6 , pp. 1157-1162
    • Dong, L.1    Wang, J.A.2    Jiang, C.Y.3
  • 21
    • 0014114704 scopus 로고
    • Influence of age on the hemodynamic response to exercise
    • S. Julius, A. Amery, L.S. Whitlock, J. Conway Influence of age on the hemodynamic response to exercise Circulation 36 1967 222 230
    • (1967) Circulation , vol.36 , pp. 222-230
    • Julius, S.1    Amery, A.2    Whitlock, L.S.3    Conway, J.4
  • 22
    • 84859493387 scopus 로고    scopus 로고
    • Survival after biventricular mechanical circulatory support: Does the type of device matter?
    • M. Kirsch, J.P. Mazzucotelli, J.C. Roussel Survival after biventricular mechanical circulatory support: Does the type of device matter? J Heart Lung Transplant 2012 January 11
    • (2012) J Heart Lung Transplant
    • Kirsch, M.1    Mazzucotelli, J.P.2    Roussel, J.C.3
  • 23
    • 79957990950 scopus 로고    scopus 로고
    • Initial clinical experience of total cardiac replacement with dual HeartMate-II axial flow pumps for severe biventricular heart failure
    • M. Loebe, B. Bruckner, M.J. Reardon Initial clinical experience of total cardiac replacement with dual HeartMate-II axial flow pumps for severe biventricular heart failure Methodist Debakey Cardiovasc J 7 2011 40 44
    • (2011) Methodist Debakey Cardiovasc J , vol.7 , pp. 40-44
    • Loebe, M.1    Bruckner, B.2    Reardon, M.J.3
  • 24
    • 77956879634 scopus 로고    scopus 로고
    • Successful use of the HeartWare HVAD rotary blood pump for biventricular support
    • M. Strueber, A.L. Meyer, D. Malehsa, A. Haverich Successful use of the HeartWare HVAD rotary blood pump for biventricular support J Thorac Cardiovasc Surg 140 2010 936 937
    • (2010) J Thorac Cardiovasc Surg , vol.140 , pp. 936-937
    • Strueber, M.1    Meyer, A.L.2    Malehsa, D.3    Haverich, A.4
  • 25
    • 84855830794 scopus 로고    scopus 로고
    • Placement of 2 implantable centrifugal pumps to serve as a total artificial heart after cardiectomy
    • M. Strueber, J.D. Schmitto, I. Kutschka, A. Haverich Placement of 2 implantable centrifugal pumps to serve as a total artificial heart after cardiectomy J Thorac Cardiovasc Surg 143 2012 507 509
    • (2012) J Thorac Cardiovasc Surg , vol.143 , pp. 507-509
    • Strueber, M.1    Schmitto, J.D.2    Kutschka, I.3    Haverich, A.4
  • 26
    • 77953704021 scopus 로고    scopus 로고
    • Long-term biventricular support with the heartware implantable continuous flow pump
    • R. Hetzer, T. Krabatsch, A. Stepanenko, E.V. Potapov Long-term biventricular support with the heartware implantable continuous flow pump J Heart Lung Transplant 29 2010 822 824
    • (2010) J Heart Lung Transplant , vol.29 , pp. 822-824
    • Hetzer, R.1    Krabatsch, T.2    Stepanenko, A.3    Potapov, E.V.4
  • 27
    • 4644312137 scopus 로고    scopus 로고
    • Biventricular assistance with the Jarvik Flowmaker: A case report
    • O.H. Frazier, T.J. Myers, I. Gregoric Biventricular assistance with the Jarvik Flowmaker: a case report J Thorac Cardiovasc Surg 128 2004 625 626
    • (2004) J Thorac Cardiovasc Surg , vol.128 , pp. 625-626
    • Frazier, O.H.1    Myers, T.J.2    Gregoric, I.3
  • 28
    • 80052774775 scopus 로고    scopus 로고
    • Biventricular circulatory support with two miniaturized implantable assist devices
    • T. Krabatsch, E. Potapov, A. Stepanenko Biventricular circulatory support with two miniaturized implantable assist devices Circulation 124 11 Suppl 2011 S179 S186
    • (2011) Circulation , vol.124 , Issue.11 SUPPL.
    • Krabatsch, T.1    Potapov, E.2    Stepanenko, A.3
  • 29
    • 72249109546 scopus 로고    scopus 로고
    • Second INTERMACS annual report: More than 1,000 primary left ventricular assist device implants
    • J.K. Kirklin, D.C. Naftel, R.L. Kormos Second INTERMACS annual report: more than 1,000 primary left ventricular assist device implants J Heart Lung Transplant 29 2010 1 10
    • (2010) J Heart Lung Transplant , vol.29 , pp. 1-10
    • Kirklin, J.K.1    Naftel, D.C.2    Kormos, R.L.3
  • 30
    • 46249084728 scopus 로고    scopus 로고
    • Miniaturized HIA microdiagonal pump as left ventricular assist device in a sheep model
    • J.D. Schmitto, P. Ortmann, M. Akdis Miniaturized HIA microdiagonal pump as left ventricular assist device in a sheep model ASAIO J 54 2008 233 236
    • (2008) ASAIO J , vol.54 , pp. 233-236
    • Schmitto, J.D.1    Ortmann, P.2    Akdis, M.3
  • 31
    • 78649614599 scopus 로고    scopus 로고
    • Ventricular assist device in patients with prosthetic heart valves
    • S.A. Mokashi, J.D. Schmitto, L.S. Lee Ventricular assist device in patients with prosthetic heart valves Artif Organs 34 2010 1030 1034
    • (2010) Artif Organs , vol.34 , pp. 1030-1034
    • Mokashi, S.A.1    Schmitto, J.D.2    Lee, L.S.3
  • 32
    • 78649569353 scopus 로고    scopus 로고
    • Extracorporeal circulation for rewarming in drowning and near-drowning pediatric patients
    • K.O. Coskun, A.F. Popov, J.D. Schmitto Extracorporeal circulation for rewarming in drowning and near-drowning pediatric patients Artif Organs 34 2010 1026 1030
    • (2010) Artif Organs , vol.34 , pp. 1026-1030
    • Coskun, K.O.1    Popov, A.F.2    Schmitto, J.D.3
  • 33
    • 58349083287 scopus 로고    scopus 로고
    • Progressive right ventricular failure is not explained by myocardial ischemia in a pig model of right ventricular pressure overload
    • J.D. Schmitto, H. Doerge, H. Post Progressive right ventricular failure is not explained by myocardial ischemia in a pig model of right ventricular pressure overload Eur J Cardiothorac Surg 35 2009 229 234
    • (2009) Eur J Cardiothorac Surg , vol.35 , pp. 229-234
    • Schmitto, J.D.1    Doerge, H.2    Post, H.3
  • 34
    • 77950821200 scopus 로고    scopus 로고
    • Cardiac function during mild hypothermia in pigs: Increased inotropy at the expense of diastolic dysfunction
    • H. Post, J.D. Schmitto, P. Steendijk Cardiac function during mild hypothermia in pigs: increased inotropy at the expense of diastolic dysfunction Acta Physiol (Oxf) 199 2010 43 52
    • (2010) Acta Physiol (Oxf) , vol.199 , pp. 43-52
    • Post, H.1    Schmitto, J.D.2    Steendijk, P.3
  • 35
    • 78649544171 scopus 로고    scopus 로고
    • A novel, innovative ovine model of chronic ischemic cardiomyopathy induced by multiple coronary ligations
    • J.D. Schmitto, S.A. Mokashi, L.S. Lee A novel, innovative ovine model of chronic ischemic cardiomyopathy induced by multiple coronary ligations Artif Organs 34 2010 918 922
    • (2010) Artif Organs , vol.34 , pp. 918-922
    • Schmitto, J.D.1    Mokashi, S.A.2    Lee, L.S.3
  • 36
    • 79951677891 scopus 로고    scopus 로고
    • Large animal models of chronic heart failure (CHF)
    • J.D. Schmitto, S.A. Mokashi, L.S. Lee Large animal models of chronic heart failure (CHF) J Surg Res 166 2011 131 137
    • (2011) J Surg Res , vol.166 , pp. 131-137
    • Schmitto, J.D.1    Mokashi, S.A.2    Lee, L.S.3
  • 37
    • 78449259091 scopus 로고    scopus 로고
    • Preventing cardiac remodeling: The combination of cell-based therapy and cardiac support therapy preserves left ventricular function in rodent model of myocardial ischemia
    • S.A. Mokashi, J. Guan, D. Wang Preventing cardiac remodeling: the combination of cell-based therapy and cardiac support therapy preserves left ventricular function in rodent model of myocardial ischemia J Thorac Cardiovasc Surg 140 2010 1374 1380
    • (2010) J Thorac Cardiovasc Surg , vol.140 , pp. 1374-1380
    • Mokashi, S.A.1    Guan, J.2    Wang, D.3
  • 38
    • 55449136627 scopus 로고    scopus 로고
    • Histological changes in a model of chronic heart failure induced by multiple sequential coronary microembolization in sheep
    • J.D. Schmitto, P. Ortmann, T. Vorkamp Histological changes in a model of chronic heart failure induced by multiple sequential coronary microembolization in sheep J Cardiovasc Surg (Torino) 49 2008 533 537
    • (2008) J Cardiovasc Surg (Torino) , vol.49 , pp. 533-537
    • Schmitto, J.D.1    Ortmann, P.2    Vorkamp, T.3
  • 39
    • 45949104301 scopus 로고    scopus 로고
    • Chronic heart failure induced by multiple sequential coronary microembolization in sheep
    • J.D. Schmitto, P. Ortmann, R. Wachter Chronic heart failure induced by multiple sequential coronary microembolization in sheep Int J Artif Organs 31 2008 348 353
    • (2008) Int J Artif Organs , vol.31 , pp. 348-353
    • Schmitto, J.D.1    Ortmann, P.2    Wachter, R.3
  • 40
    • 78649585153 scopus 로고    scopus 로고
    • The role of phospho-adenosine monophosphate-activated protein kinase and vascular endothelial growth factor in a model of chronic heart failure
    • F. Heidrich, S. Sossalla, H. Schotola The role of phospho-adenosine monophosphate-activated protein kinase and vascular endothelial growth factor in a model of chronic heart failure Artif Organs 34 2010 969 979
    • (2010) Artif Organs , vol.34 , pp. 969-979
    • Heidrich, F.1    Sossalla, S.2    Schotola, H.3
  • 41
    • 70450231538 scopus 로고    scopus 로고
    • Hemodynamic changes in a model of chronic heart failure induced by multiple sequential coronary microembolization in sheep
    • J.D. Schmitto, K.O. Coskun, S.T. Coskun Hemodynamic changes in a model of chronic heart failure induced by multiple sequential coronary microembolization in sheep Artif Organs 33 2009 947 952
    • (2009) Artif Organs , vol.33 , pp. 947-952
    • Schmitto, J.D.1    Coskun, K.O.2    Coskun, S.T.3
  • 42
    • 67449085092 scopus 로고    scopus 로고
    • Proof of concept: Hemodynamic response to long-term partial ventricular support with the synergy pocket micro-pump
    • B. Meyns, S. Klotz, A. Simon Proof of concept: hemodynamic response to long-term partial ventricular support with the synergy pocket micro-pump J Am Coll Cardiol 54 2009 79 86
    • (2009) J Am Coll Cardiol , vol.54 , pp. 79-86
    • Meyns, B.1    Klotz, S.2    Simon, A.3
  • 43
    • 76149091231 scopus 로고    scopus 로고
    • Partial mechanical long-term support with the CircuLite Syndergy pump as bridge-to-transplant in congestive heart failure
    • S. Klotz, B. Meyns, A. Simon Partial mechanical long-term support with the CircuLite Syndergy pump as bridge-to-transplant in congestive heart failure Thorac Cardiovasc Surg 58 Suppl 2 2010 S173 S178
    • (2010) Thorac Cardiovasc Surg , vol.58 , Issue.SUPPL. 2
    • Klotz, S.1    Meyns, B.2    Simon, A.3
  • 44
    • 73349140879 scopus 로고    scopus 로고
    • Single-centre experience with the Thoratec paracorporeal ventricular assist device for patients with primary cardiac failure
    • M. Kirsch, E. Vermes, T. Damy Single-centre experience with the Thoratec paracorporeal ventricular assist device for patients with primary cardiac failure Arch Cardiovasc Dis 102 2009 509 518
    • (2009) Arch Cardiovasc Dis , vol.102 , pp. 509-518
    • Kirsch, M.1    Vermes, E.2    Damy, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.