메뉴 건너뛰기




Volumn 54, Issue 3, 2008, Pages 233-236

Miniaturized HIA microdiagonal pump as left ventricular assist device in a sheep model

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVATED CLOTTING TIME; ANIMAL STUDIES; ANTI-COAGULATION; ARTERY PRESSURE; ASPARTATE AMINOTRANSFERASE; BLOOD PUMP; BLOOD SAMPLES; CLINICAL TRIAL; CONTINUOUS FLOWS; CURRENT TECHNOLOGY; GLUTAMATE DEHYDROGENASE; GLUTAMIC-OXALOACETIC TRANSAMINASE; HEMOGLOBIN LEVELS; LEFT ATRIUMS; LEFT VENTRICULAR ASSIST DEVICES; MACROSCOPIC EXAMINATION; SHEEP MODEL;

EID: 46249084728     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e318175258e     Document Type: Article
Times cited : (14)

References (22)
  • 1
    • 67649217886 scopus 로고    scopus 로고
    • National Center for Health Statistics: Health, United States. 1995 DHHS No. (PHS) 96 ± 1232. US Govt. Printing Office, 1996.
    • National Center for Health Statistics: Health, United States. 1995 DHHS No. (PHS) 96 ± 1232. US Govt. Printing Office, 1996.
  • 3
    • 0027501620 scopus 로고
    • Epidemiology of heart failure in the United States
    • Gillum RF: Epidemiology of heart failure in the United States. Am Heart J 126: 1042-1047, 1993.
    • (1993) Am Heart J , vol.126 , pp. 1042-1047
    • Gillum, R.F.1
  • 4
    • 0033838655 scopus 로고    scopus 로고
    • Incidence and epidemiology of heart failure
    • Kannel WB: Incidence and epidemiology of heart failure. Heart Fail Rev 5: 167-173, 2000.
    • (2000) Heart Fail Rev , vol.5 , pp. 167-173
    • Kannel, W.B.1
  • 5
    • 4544288721 scopus 로고    scopus 로고
    • Extensive coagulation monitoring in patients after implantation of the MicroMed Debakey continuous flow axial pump
    • Bonaros N, Mueller MR, Salat A, et al: Extensive coagulation monitoring in patients after implantation of the MicroMed Debakey continuous flow axial pump. ASAIO J 50: 424-431, 2004.
    • (2004) ASAIO J , vol.50 , pp. 424-431
    • Bonaros, N.1    Mueller, M.R.2    Salat, A.3
  • 7
    • 0035892018 scopus 로고    scopus 로고
    • Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group. Long term mechanical left ventricular assistance for end stage heart failure
    • Rose EA, Gelijns AC, Moskowitz AJ, et al: Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group. Long term mechanical left ventricular assistance for end stage heart failure. N Engl J Med 345: 1435-1443, 2001.
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 8
    • 4143052707 scopus 로고    scopus 로고
    • CardioWest Total Artificial Heart Investigators. Cardiac replacement with a total artificial heart as a bridge to transplantation
    • Copeland JG, Smith RG, Arabia FA, et al: CardioWest Total Artificial Heart Investigators. Cardiac replacement with a total artificial heart as a bridge to transplantation. N Engl J Med 351: 859-867, 2004.
    • (2004) N Engl J Med , vol.351 , pp. 859-867
    • Copeland, J.G.1    Smith, R.G.2    Arabia, F.A.3
  • 9
    • 2342666130 scopus 로고    scopus 로고
    • Experimental Testing of a New Left Ventricular Assist device The Microdiagonal Blood Pump
    • Christiansen S, Demircan L, Kwant PB, et al: Experimental Testing of a New Left Ventricular Assist device The Microdiagonal Blood Pump. ASAIO J 50: 200-204, 2004.
    • (2004) ASAIO J , vol.50 , pp. 200-204
    • Christiansen, S.1    Demircan, L.2    Kwant, P.B.3
  • 10
    • 0035004645 scopus 로고    scopus 로고
    • Atrial, ventricular, or both cannulation sites to optimize left ventricular assistance
    • Tevaearai HT, Mueller XM, Jegger D, Horisberger J, Von Segesser L: Atrial, ventricular, or both cannulation sites to optimize left ventricular assistance. ASAIO J 47: 261-265, 2001.
    • (2001) ASAIO J , vol.47 , pp. 261-265
    • Tevaearai, H.T.1    Mueller, X.M.2    Jegger, D.3    Horisberger, J.4    Von Segesser, L.5
  • 11
    • 15444363212 scopus 로고    scopus 로고
    • Concept for a new hydrodynamic blood bearing for miniature blood pumps
    • Kink T, Reul H: Concept for a new hydrodynamic blood bearing for miniature blood pumps. Artif Organs 28: 916-920, 2004.
    • (2004) Artif Organs , vol.28 , pp. 916-920
    • Kink, T.1    Reul, H.2
  • 12
    • 33748435950 scopus 로고    scopus 로고
    • Mechanical circulatory support therapy as a bridge to transplant or recovery (new advances)
    • Kirklin JK, Holman WL: Mechanical circulatory support therapy as a bridge to transplant or recovery (new advances). Curr Opin Cardiol 21: 120-126, 2006.
    • (2006) Curr Opin Cardiol , vol.21 , pp. 120-126
    • Kirklin, J.K.1    Holman, W.L.2
  • 13
    • 0034063060 scopus 로고    scopus 로고
    • Anticoagulation during use of a left ventricular assist device
    • Takahama T, Kanai F, Onishi K: Anticoagulation during use of a left ventricular assist device. ASAIO J 46: 354-357, 2000.
    • (2000) ASAIO J , vol.46 , pp. 354-357
    • Takahama, T.1    Kanai, F.2    Onishi, K.3
  • 14
    • 67649217885 scopus 로고    scopus 로고
    • Midterm run of the miniaturized MEDOS diagonalpump as left ventricular assist device in a sheep model
    • Schöndube F, Steinke K, Alekuzei H, et al: Midterm run of the miniaturized MEDOS diagonalpump as left ventricular assist device in a sheep model. Artif Organs 27: 328, 2003.
    • (2003) Artif Organs , vol.27 , pp. 328
    • Schöndube, F.1    Steinke, K.2    Alekuzei, H.3
  • 16
    • 0019720777 scopus 로고
    • Platelet function and coagulation parameters in sheep during experimental vascular research
    • Tillman P, Carson SN, Talken L: Platelet function and coagulation parameters in sheep during experimental vascular research. Lab Animal Sci 31: 263-267, 1981.
    • (1981) Lab Animal Sci , vol.31 , pp. 263-267
    • Tillman, P.1    Carson, S.N.2    Talken, L.3
  • 17
    • 0015025259 scopus 로고
    • Blood coagulation values of sheep
    • Gajewski J, Povar ML: Blood coagulation values of sheep. Amer J Vet Res 32: 405-409, 1971.
    • (1971) Amer J Vet Res , vol.32 , pp. 405-409
    • Gajewski, J.1    Povar, M.L.2
  • 18
    • 0012453292 scopus 로고
    • Hematologic and coagulation studies in various animal species
    • Didisheim P, Hattori K, Lewis JH: Hematologic and coagulation studies in various animal species. J Lab Clin Med 53: 866-875, 1959.
    • (1959) J Lab Clin Med , vol.53 , pp. 866-875
    • Didisheim, P.1    Hattori, K.2    Lewis, J.H.3
  • 19
    • 0014970065 scopus 로고
    • A comparative study of platelet aggregation in man and laboratory animals
    • MacMillan DC, Sim AK: A comparative study of platelet aggregation in man and laboratory animals. Throm Diath Haemorrh 24: 385, 1970.
    • (1970) Throm Diath Haemorrh , vol.24 , pp. 385
    • MacMillan, D.C.1    Sim, A.K.2
  • 20
    • 0016183259 scopus 로고
    • Changes in coagulation and platelet function during prolonged extracorporeal circulation (ECC) in sheep and man
    • Fong SW, Burns NE, Williams G, Woldanski C, Gazzaniga AB, Bartlett RH: Changes in coagulation and platelet function during prolonged extracorporeal circulation (ECC) in sheep and man. ASAIO Trans XX: 239-247, 1974.
    • (1974) ASAIO Trans , vol.20 , pp. 239-247
    • Fong, S.W.1    Burns, N.E.2    Williams, G.3    Woldanski, C.4    Gazzaniga, A.B.5    Bartlett, R.H.6
  • 21
    • 0018173112 scopus 로고
    • Differential activities of heparin in human plasma and in sheep plasma: Effect of heparin molecular sizes and sources
    • Shen LL, Barlow GH, Holleman WH: Differential activities of heparin in human plasma and in sheep plasma: Effect of heparin molecular sizes and sources. Thromb Res 13: 671-679, 1978.
    • (1978) Thromb Res , vol.13 , pp. 671-679
    • Shen, L.L.1    Barlow, G.H.2    Holleman, W.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.