메뉴 건너뛰기




Volumn 76, Issue , 2012, Pages 159-165

An ion source for radiofrequency-pulsed glow discharge time-of-flight mass spectrometry

Author keywords

GD MS; Glow discharge; Ion source

Indexed keywords

ANALYTES; DIRECT ANALYSIS; DISCHARGE CONDITIONS; GD-MS; IONIC SPECIES; LIMITS OF DETECTION; LINEAR CALIBRATION; MAXIMUM INTENSITIES; NEW DESIGN; ORTHOGONAL TIME-OF-FLIGHT MASS SPECTROMETERS; PLASMA GAS; PULSE PERIOD; PULSE PROFILE; PULSE SHAPES; RADIO FREQUENCIES; SOLID SAMPLES; TIME OF FLIGHT MASS SPECTROMETRY; TWO SOURCES;

EID: 84867403175     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2012.06.043     Document Type: Article
Times cited : (12)

References (22)
  • 1
    • 69149088623 scopus 로고    scopus 로고
    • Critical revision of GD-MS, LA-ICP-MS and SIMS as inorganic mass spectrometric techniques for direct solid analysis
    • J. Pisonero, B. Fernández, and D. Günther Critical revision of GD-MS, LA-ICP-MS and SIMS as inorganic mass spectrometric techniques for direct solid analysis J. Anal. At. Spectrom. 24 2009 1145 1160
    • (2009) J. Anal. At. Spectrom. , vol.24 , pp. 1145-1160
    • Pisonero, J.1    Fernández, B.2    Günther, D.3
  • 2
    • 2442482411 scopus 로고    scopus 로고
    • Radio-frequency glow discharge spectrometry: A critical review
    • M.R. Winchester, and R. Payling Radio-frequency glow discharge spectrometry: a critical review Spectrochim. Acta Part B 59 2004 607 666
    • (2004) Spectrochim. Acta Part B , vol.59 , pp. 607-666
    • Winchester, M.R.1    Payling, R.2
  • 3
    • 33747595170 scopus 로고    scopus 로고
    • Evaluation of a pulsed glow discharge time-of-flight mass spectrometer as a detector for gas chromatography and the influence of the glow discharge source parameters on the information volume in chemical speciation analysis
    • D. Fliegel, K. Fuhrer, M. Gonin, and D. Günther Evaluation of a pulsed glow discharge time-of-flight mass spectrometer as a detector for gas chromatography and the influence of the glow discharge source parameters on the information volume in chemical speciation analysis Anal. Bioanal. Chem. 386 2006 169 179
    • (2006) Anal. Bioanal. Chem. , vol.386 , pp. 169-179
    • Fliegel, D.1    Fuhrer, K.2    Gonin, M.3    Günther, D.4
  • 4
    • 0030180686 scopus 로고    scopus 로고
    • Radiofrequency glow discharge mass spectrometry for the characterization of bulk polymers
    • C.R. Shick Jr., P.A. DePalma Jr., and R.K. Marcus Radiofrequency glow discharge mass spectrometry for the characterization of bulk polymers Anal. Chem. 68 1996 2113 2121
    • (1996) Anal. Chem. , vol.68 , pp. 2113-2121
    • Shick, Jr.C.R.1    Depalma, Jr.P.A.2    Marcus, R.K.3
  • 5
    • 0027654160 scopus 로고
    • Design and characterization of radio-frequency powered glow discharge source for double-focusing mass spectrometer
    • D.C. Duckworth, D.L. Donohue, D.H. Smith, T.A. Lewis, and R.K. Marcus Design and characterization of radio-frequency powered glow discharge source for double-focusing mass spectrometer Anal. Chem. 65 1993 2478 2484
    • (1993) Anal. Chem. , vol.65 , pp. 2478-2484
    • Duckworth, D.C.1    Donohue, D.L.2    Smith, D.H.3    Lewis, T.A.4    Marcus, R.K.5
  • 6
    • 23944491835 scopus 로고    scopus 로고
    • Depth profiling with a modified dc- and rf- Grimm-type glow discharge operated with high gas flow rates and coupled to a high resolution mass spectrometer
    • J. Pisonero, I. Feldmann, N. Bordel, A. Sanz-Medel, and N. Jakubowski Depth profiling with a modified dc- and rf- Grimm-type glow discharge operated with high gas flow rates and coupled to a high resolution mass spectrometer Anal. Bioanal. Chem. 382 2005 1965 1974
    • (2005) Anal. Bioanal. Chem. , vol.382 , pp. 1965-1974
    • Pisonero, J.1    Feldmann, I.2    Bordel, N.3    Sanz-Medel, A.4    Jakubowski, N.5
  • 7
    • 33747651676 scopus 로고    scopus 로고
    • Aplication of glow discharge mass spectrometry to multielement ultra-trace determination in ultra-high purity copper and iron: A calibration approach achieving quantification and traceability
    • R. Matschat, J. Hinrichs, and H. Kipphardt Aplication of glow discharge mass spectrometry to multielement ultra-trace determination in ultra-high purity copper and iron: a calibration approach achieving quantification and traceability Anal. Bioanal. Chem. 386 2006 125 141
    • (2006) Anal. Bioanal. Chem. , vol.386 , pp. 125-141
    • Matschat, R.1    Hinrichs, J.2    Kipphardt, H.3
  • 11
    • 0034271424 scopus 로고    scopus 로고
    • Microsecond pulsed glow discharge optical emission spectrometry - Investigation of temporal emission characteristics
    • A. Bengtson, C. Yang, and W.W. Harrison Microsecond pulsed glow discharge optical emission spectrometry - investigation of temporal emission characteristics J. Anal. At. Spectrom. 15 2000 1279 1284
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 1279-1284
    • Bengtson, A.1    Yang, C.2    Harrison, W.W.3
  • 12
    • 0035249675 scopus 로고    scopus 로고
    • Determination of fifteen elements in grey cast irons using glow discharge optical emission spectrometry
    • M.R. Winchester, and J.K. Miller Determination of fifteen elements in grey cast irons using glow discharge optical emission spectrometry J. Anal. At. Spectrom. 16 2001 122 128
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 122-128
    • Winchester, M.R.1    Miller, J.K.2
  • 13
    • 0034269737 scopus 로고    scopus 로고
    • Microsecond pulsed Grimm glow discharge as a source for time of flight mass spectrometry
    • C. Yang, M. Mohill, and W.W. Harrison Microsecond pulsed Grimm glow discharge as a source for time of flight mass spectrometry J. Anal. At. Spectrom. 15 2000 1255 1260
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 1255-1260
    • Yang, C.1    Mohill, M.2    Harrison, W.W.3
  • 14
    • 0037107356 scopus 로고    scopus 로고
    • Development and analytical characterization of a Grimm-type glow discharge ion source operated with high gas flow rates and coupled to a mass spectrometer with high mass resolution
    • C. Beyer, I. Feldmann, D. Gilmour, V. Hoffmann, and N. Jakubowski Development and analytical characterization of a Grimm-type glow discharge ion source operated with high gas flow rates and coupled to a mass spectrometer with high mass resolution Spectrochim. Acta Part B 57 2002 1521 1533
    • (2002) Spectrochim. Acta Part B , vol.57 , pp. 1521-1533
    • Beyer, C.1    Feldmann, I.2    Gilmour, D.3    Hoffmann, V.4    Jakubowski, N.5
  • 15
    • 0038266830 scopus 로고    scopus 로고
    • Analytical potential of a glow discharge chamber coupled to a time of flight mass spectrometer for qualitative in depth profile analysis
    • M. Vázquez Peláez, J. Pisonero, J.M. Costa- Fernández, R. Pereiro, N. Bordel, and A. Sanz-Medel Analytical potential of a glow discharge chamber coupled to a time of flight mass spectrometer for qualitative in depth profile analysis J. Anal. At. Spectrom. 18 2003 612 617
    • (2003) J. Anal. At. Spectrom. , vol.18 , pp. 612-617
    • Vázquez Peláez, M.1    Pisonero, J.2    Costa-Fernández, J.M.3    Pereiro, R.4    Bordel, N.5    Sanz-Medel, A.6
  • 16
    • 0034740355 scopus 로고    scopus 로고
    • A simple glow discharge ion source for direct solid analysis by on-axis time-of-fligth mass spectrometry
    • J. Pisonero, J.M. Costa, R. Pereiro, N. Bordel, and A. Sanz-Medel A simple glow discharge ion source for direct solid analysis by on-axis time-of-fligth mass spectrometry J. Anal. At. Spectrom. 16 2001 1253 1258
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 1253-1258
    • Pisonero, J.1    Costa, J.M.2    Pereiro, R.3    Bordel, N.4    Sanz-Medel, A.5
  • 17
    • 84858073405 scopus 로고    scopus 로고
    • Spatial emission distribution of a pulsed radiofrequency glow discharge: Influence of the pulse frequency
    • 10.1016/j.sab.2012.01.008
    • R. Valledor, J. Pisonero, T. Nelis, and N. Bordel Spatial emission distribution of a pulsed radiofrequency glow discharge: Influence of the pulse frequency Spectrochim. Acta Part B 2012 10.1016/j.sab.2012.01.008
    • (2012) Spectrochim. Acta Part B
    • Valledor, R.1    Pisonero, J.2    Nelis, T.3    Bordel, N.4
  • 18
    • 77951298081 scopus 로고    scopus 로고
    • A comparison of non-pulsed and pulsed radiofrequency glow discharge orthogonal time-of-flight mass spectrometry for analytical purposes
    • L. Lobo, J. Pisonero, N. Bordel, R. Pereiro, A. Tempez, P. Chapon, J. Michler, M. Hohl, and A. Sanz-Medel A comparison of non-pulsed and pulsed radiofrequency glow discharge orthogonal time-of-flight mass spectrometry for analytical purposes J. Anal. At. Spectrom. 24 2009 1373 1381
    • (2009) J. Anal. At. Spectrom. , vol.24 , pp. 1373-1381
    • Lobo, L.1    Pisonero, J.2    Bordel, N.3    Pereiro, R.4    Tempez, A.5    Chapon, P.6    Michler, J.7    Hohl, M.8    Sanz-Medel, A.9
  • 19
    • 33646553071 scopus 로고    scopus 로고
    • Pulsed r.f.-glow discharge time of flight mass spectrometry for fast surface and interface analysis of conductive and non-conductive materials
    • M. Hohl, A. Kanzari, J. Michler, T. Nelis, K. Fuhrer, and M. Gonin Pulsed r.f.-glow discharge time of flight mass spectrometry for fast surface and interface analysis of conductive and non-conductive materials Surf. Interface Anal. 38 2006 292 295
    • (2006) Surf. Interface Anal. , vol.38 , pp. 292-295
    • Hohl, M.1    Kanzari, A.2    Michler, J.3    Nelis, T.4    Fuhrer, K.5    Gonin, M.6
  • 22
    • 34250900861 scopus 로고    scopus 로고
    • The afterglow mystery of pulsed glow discharges and the role of dissociative electron-ion recombination
    • A. Bogaerts The afterglow mystery of pulsed glow discharges and the role of dissociative electron-ion recombination J. Anal. At. Spectrom. 22 2007 502 512
    • (2007) J. Anal. At. Spectrom. , vol.22 , pp. 502-512
    • Bogaerts, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.