메뉴 건너뛰기




Volumn 43, Issue 8, 2005, Pages 869-875

Influence of short-term venous stasis on clinical chemistry testing

Author keywords

Blood collection; Laboratory testing; Pre analytical variability; Standardization tourniquet; Venous stasis

Indexed keywords

ALANINE AMINOTRANSFERASE; ALBUMIN; CALCIUM; CHLORIDE; CHOLESTEROL; CREATINE KINASE; CREATININE; ELECTROLYTE; ENZYME; GLUCOSE; IRON; POTASSIUM;

EID: 26844488850     PISSN: 14346621     EISSN: 14346621     Source Type: Journal    
DOI: 10.1515/CCLM.2005.146     Document Type: Article
Times cited : (62)

References (13)
  • 2
    • 0017837714 scopus 로고
    • Standardisation of obtaining blood samples: Influence of tourniquet application on 33 constituents of blood and serum
    • Junge B, Hoffmeister H, Feddersen HM, Rocker L. Standardisation of obtaining blood samples: influence of tourniquet application on 33 constituents of blood and serum. Dtsch Med Wochenschr 1978;103:260-5.
    • (1978) Dtsch. Med. Wochenschr. , vol.103 , pp. 260-265
    • Junge, B.1    Hoffmeister, H.2    Feddersen, H.M.3    Rocker, L.4
  • 3
    • 0018900917 scopus 로고
    • The effects of stasis with and without exercise on free calcium, various cations, and related parameters
    • Renoe BW, McDonald JM, Ladenson JH. The effects of stasis with and without exercise on free calcium, various cations, and related parameters. Clin Chim Acta 1980; 103:91-100.
    • (1980) Clin. Chim. Acta , vol.103 , pp. 91-100
    • Renoe, B.W.1    McDonald, J.M.2    Ladenson, J.H.3
  • 4
    • 0018692033 scopus 로고
    • Gross errors made by routine blood sampling from two sites using a tourniquet applied at different positions
    • McNair P, Nielsen SL, Christiansen C, Axelsson C. Gross errors made by routine blood sampling from two sites using a tourniquet applied at different positions. Clin Chim Acta 1979;98:113-8.
    • (1979) Clin. Chim. Acta , vol.98 , pp. 113-118
    • McNair, P.1    Nielsen, S.L.2    Christiansen, C.3    Axelsson, C.4
  • 5
    • 0026882962 scopus 로고
    • Blood gas and electrolyte changes after tourniquet application in total knee replacement surgery
    • Kang HJ, Han CD, Jahng JS, Ko SO. Blood gas and electrolyte changes after tourniquet application in total knee replacement surgery. Yonsei Med J 1992;33:153-8.
    • (1992) Yonsei Med. J. , vol.33 , pp. 153-158
    • Kang, H.J.1    Han, C.D.2    Jahng, J.S.3    Ko, S.O.4
  • 6
    • 0025351248 scopus 로고
    • Venepuncture for calcium assays: Should we still avoid the tourniquet?
    • McMullan AD, Burns J, Paterson CR. Venepuncture for calcium assays: should we still avoid the tourniquet? Postgrad Med J 1990;66:547-8.
    • (1990) Postgrad. Med. J. , vol.66 , pp. 547-548
    • McMullan, A.D.1    Burns, J.2    Paterson, C.R.3
  • 7
    • 26844466097 scopus 로고    scopus 로고
    • Specimen collection and testing
    • 2nd ed. Springhouse, PA: Springhouse Corp
    • Buffington S. Specimen collection and testing. In: Nursing procedures, 2nd ed. Springhouse, PA: Springhouse Corp, 1996:135-8.
    • (1996) Nursing Procedures , pp. 135-138
    • Buffington, S.1
  • 8
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8:135-60.
    • (1999) Stat. Methods Med. Res. , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0041973611 scopus 로고    scopus 로고
    • Conveying the importance of the preanalytical phase
    • Young DS. Conveying the importance of the preanalytical phase. Clin Chem Lab Med 2003;41:884-7.
    • (2003) Clin. Chem. Lab. Med. , vol.41 , pp. 884-887
    • Young, D.S.1
  • 11
    • 26844511910 scopus 로고    scopus 로고
    • Blood collection techniques. An informative guide to venous blood collection
    • Kremsmünster, Austria: Greiner Bio-One GmbH
    • Dittmann M. Blood collection techniques. An informative guide to venous blood collection. Kremsmünster, Austria: Greiner Bio-One GmbH, 2001:1-24.
    • (2001) , pp. 1-24
    • Dittmann, M.1
  • 12
    • 0018832049 scopus 로고
    • A comparison of methods of blood withdrawal and sample preparation for potassium measurements
    • Hill AB, Nahrwold ML, Noonan D, Northrop P. A comparison of methods of blood withdrawal and sample preparation for potassium measurements. Anesthesiology 1980;53:60-3.
    • (1980) Anesthesiology , vol.53 , pp. 60-63
    • Hill, A.B.1    Nahrwold, M.L.2    Noonan, D.3    Northrop, P.4
  • 13
    • 3242784954 scopus 로고    scopus 로고
    • Towards quality specifications in extra-analytical phases of laboratory activity
    • Plebani M. Towards quality specifications in extra-analytical phases of laboratory activity. Clin Chem Lab Med 2004;42:576-7.
    • (2004) Clin. Chem. Lab. Med. , vol.42 , pp. 576-577
    • Plebani, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.