Comparison of samples obtained from 3.2% sodium citrate glass and two 3.2% sodium citrate plastic blood collection tubes used in coagulation testing

Author keywords

Coagulation testing; Glass tubes; Plastic tubes

Indexed keywords

ANTITHROMBIN; BLOOD CLOTTING FACTOR 13; CITRATE SODIUM; PLASMINOGEN; PROTEIN C; PROTEIN S 100;

EID: 9644279422     PISSN: 00029173     EISSN: None     Source Type: Journal    
DOI: 10.1309/7V2KP1HP9Q29BMN2     Document Type: Article
Times cited : (29)

References (6)
  • 1
    • 0036825378 scopus 로고    scopus 로고
    • How to evaluate the influence of blood collection systems on the international sensitivity index: Protocol applied to two new evacuated tubes and eight coagulometer/thromboplastin combinations
    • Tripodi A, Chantarangkul V, Bressi C, et al. How to evaluate the influence of blood collection systems on the international sensitivity index: protocol applied to two new evacuated tubes and eight coagulometer/ thromboplastin combinations. Thromb Res. 2002;108:85-89.
    • (2002) Thromb Res , vol.108 , pp. 85-89
    • Tripodi, A.1    Chantarangkul, V.2    Bressi, C.3
  • 2
    • 0032445781 scopus 로고    scopus 로고
    • Laboratory control of oral anticoagulant therapy: Preservation of prothrombin time specimens using a polypropylene collection system
    • Ridyard J, Bhavnani M, Seal LH. Laboratory control of oral anticoagulant therapy: preservation of prothrombin time specimens using a polypropylene collection system. Clin Lab Haematol. 1998;20:369-372.
    • (1998) Clin Lab Haematol , vol.20 , pp. 369-372
    • Ridyard, J.1    Bhavnani, M.2    Seal, L.H.3
  • 3
    • 0032766737 scopus 로고    scopus 로고
    • Measurement of prothrombin time in patients on oral anticoagulant therapy: Effect of two different evacuated tubes
    • D'Angelo G, Villa C. Measurement of prothrombin time in patients on oral anticoagulant therapy: effect of two different evacuated tubes [letter]. Haematologica. 1999;84:656-657.
    • (1999) Haematologica , vol.84 , pp. 656-657
    • D'Angelo, G.1    Villa, C.2
  • 4
    • 0034019051 scopus 로고    scopus 로고
    • Plastic versus siliconized glass tubes: Evaluation in current laboratory practice
    • Biron-Andreani C, Mallol C, Seguret F, et al. Plastic versus siliconized glass tubes: evaluation in current laboratory practice [letter]. Thromb Haemost. 2000;83:800-801.
    • (2000) Thromb Haemost , vol.83 , pp. 800-801
    • Biron-Andreani, C.1    Mallol, C.2    Seguret, F.3
  • 5
    • 0141508855 scopus 로고    scopus 로고
    • A comparison of blood collection in glass versus plastic Vacutainers on results of esoteric coagulation assays
    • Flanders MM, Crist R, Rodgers GM. A comparison of blood collection in glass versus plastic Vacutainers on results of esoteric coagulation assays. Lab Med. 2003;34:732-735.
    • (2003) Lab Med , vol.34 , pp. 732-735
    • Flanders, M.M.1    Crist, R.2    Rodgers, G.M.3
  • 6
    • 0027436701 scopus 로고
    • Establishing a therapeutic range for heparin therapy
    • Brill-Edwards P, Ginsberg JS, Johnston M, et al. Establishing a therapeutic range for heparin therapy. Ann Intern Med. 1993;119:104-109.
    • (1993) Ann Intern Med , vol.119 , pp. 104-109
    • Brill-Edwards, P.1    Ginsberg, J.S.2    Johnston, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.