메뉴 건너뛰기




Volumn 3, Issue 10, 2012, Pages 2647-2657

Extended coherence length megahertz FDML and its application for anterior segment imaging

Author keywords

[No Author keywords available]

Indexed keywords

FOURIER SERIES;

EID: 84867275939     PISSN: None     EISSN: 21567085     Source Type: Journal    
DOI: 10.1364/BOE.3.002647     Document Type: Article
Times cited : (87)

References (50)
  • 2
    • 0001936881 scopus 로고
    • Measurement of intraocular distances by backscattering spectral interferometry
    • A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. Elzaiat, "Measurement of intraocular distances by backscattering spectral interferometry," Opt. Commun. 117(1-2), 43-48 (1995).
    • (1995) Opt. Commun , vol.117 , Issue.1-2 , pp. 43-48
    • Fercher, A.F.1    Hitzenberger, C.K.2    Kamp, G.3    Elzaiat, S.Y.4
  • 3
    • 0031695986 scopus 로고    scopus 로고
    • 'Coherence radar' and 'spectral radar'-new tools for dermatological diagnosis
    • G. Häusler and M. W. Lindner, "'Coherence radar' and 'spectral radar'-new tools for dermatological diagnosis," J. Biomed. Opt. 3(1), 21-31 (1998).
    • (1998) J. Biomed. Opt , vol.3 , Issue.1 , pp. 21-31
    • Häusler, G.1    Lindner, M.W.2
  • 4
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    • M. A. Choma, M. V. Sarunic, C. H. Yang, and J. A. Izatt, "Sensitivity advantage of swept source and Fourier domain optical coherence tomography," Opt. Express 11(18), 2183-2189 (2003).
    • (2003) Opt. Express , vol.11 , Issue.18 , pp. 2183-2189
    • Choma, M.A.1    Sarunic, M.V.2    Yang, C.H.3    Izatt, J.A.4
  • 5
    • 0242301675 scopus 로고    scopus 로고
    • Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
    • J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, "Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography," Opt. Lett. 28(21), 2067-2069 (2003).
    • (2003) Opt. Lett , vol.28 , Issue.21 , pp. 2067-2069
    • de Boer, J.F.1    Cense, B.2    Park, B.H.3    Pierce, M.C.4    Tearney, G.J.5    Bouma, B.E.6
  • 6
    • 0038618462 scopus 로고    scopus 로고
    • Performance of Fourier domain vs. time domain optical coherence tomography
    • R. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, "Performance of Fourier domain vs. time domain optical coherence tomography," Opt. Express 11(8), 889-894 (2003).
    • (2003) Opt. Express , vol.11 , Issue.8 , pp. 889-894
    • Leitgeb, R.1    Hitzenberger, C.K.2    Fercher, A.F.3
  • 8
    • 33645820443 scopus 로고    scopus 로고
    • Fourier domain mode locking (FDML): A new laser operating regime and applications for optical coherence tomography
    • R. Huber, M. Wojtkowski, and J. G. Fujimoto, "Fourier domain mode locking (FDML): a new laser operating regime and applications for optical coherence tomography," Opt. Express 14(8), 3225-3237 (2006).
    • (2006) Opt. Express , vol.14 , Issue.8 , pp. 3225-3237
    • Huber, R.1    Wojtkowski, M.2    Fujimoto, J.G.3
  • 9
    • 33750506518 scopus 로고    scopus 로고
    • Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s
    • R. Huber, D. C. Adler, and J. G. Fujimoto, "Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s," Opt. Lett. 31(20), 2975-2977 (2006).
    • (2006) Opt. Lett , vol.31 , Issue.20 , pp. 2975-2977
    • Huber, R.1    Adler, D.C.2    Fujimoto, J.G.3
  • 12
    • 36749059656 scopus 로고    scopus 로고
    • Fourier domain mode locking at 1050 nm for ultra- high-speed optical coherence tomography of the human retina at 236,000 axial scans per second
    • R. Huber, D. C. Adler, V. J. Srinivasan, and J. G. Fujimoto, "Fourier domain mode locking at 1050 nm for ultra- high-speed optical coherence tomography of the human retina at 236,000 axial scans per second," Opt. Lett. 32(14), 2049-2051 (2007).
    • (2007) Opt. Lett , vol.32 , Issue.14 , pp. 2049-2051
    • Huber, R.1    Adler, D.C.2    Srinivasan, V.J.3    Fujimoto, J.G.4
  • 13
    • 51849093532 scopus 로고    scopus 로고
    • Ultrahigh speed spectral/Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second
    • B. Potsaid, I. Gorczynska, V. J. Srinivasan, Y. L. Chen, J. Jiang, A. Cable, and J. G. Fujimoto, "Ultrahigh speed spectral/Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second," Opt. Express 16(19), 15149-15169 (2008).
    • (2008) Opt. Express , vol.16 , Issue.19 , pp. 15149-15169
    • Potsaid, B.1    Gorczynska, I.2    Srinivasan, V.J.3    Chen, Y.L.4    Jiang, J.5    Cable, A.6    Fujimoto, J.G.7
  • 14
    • 77957013968 scopus 로고    scopus 로고
    • Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second
    • B. Potsaid, B. Baumann, D. Huang, S. Barry, A. E. Cable, J. S. Schuman, J. S. Duker, and J. G. Fujimoto, "Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second," Opt. Express 18(19), 20029-20048 (2010).
    • (2010) Opt. Express , vol.18 , Issue.19 , pp. 20029-20048
    • Potsaid, B.1    Baumann, B.2    Huang, D.3    Barry, S.4    Cable, A.E.5    Schuman, J.S.6    Duker, J.S.7    Fujimoto, J.G.8
  • 15
    • 80052123457 scopus 로고    scopus 로고
    • OCT imaging up to 760kHz axial scan rate using single-mode 1310nm MEMs-tunable VCSELs with >100nm tuning range
    • OSA Technical Digest (CD) (Optical Society of America, 2011), paper PDPB2
    • V. Jayaraman, J. Jiang, H. Li, P. Heim, G. Cole, B. Potsaid, J. G. Fujimoto, and A. Cable, "OCT imaging up to 760kHz axial scan rate using single-mode 1310nm MEMs-tunable VCSELs with >100nm tuning range," in CLEO:2011-Laser Applications to Photonic Applications, OSA Technical Digest (CD) (Optical Society of America, 2011), paper PDPB2.
    • CLEO:2011-Laser Applications to Photonic Applications
    • Jayaraman, V.1    Jiang, J.2    Li, H.3    Heim, P.4    Cole, G.5    Potsaid, B.6    Fujimoto, J.G.7    Cable, A.8
  • 16
    • 84857216373 scopus 로고    scopus 로고
    • Design and performance of broadly tunable, narrow line-width, high repetition rate 1310nm VCSELs for swept source optical coherence tomography
    • V. Jayaraman, J. Jiang, B. Potsaid, G. Cole, J. Fujimoto, and A. Cable, "Design and performance of broadly tunable, narrow line-width, high repetition rate 1310nm VCSELs for swept source optical coherence tomography," Proc. SPIE 8276, 82760D, 82760D-11 (2012).
    • (2012) Proc. SPIE , vol.8276
    • Jayaraman, V.1    Jiang, J.2    Potsaid, B.3    Cole, G.4    Fujimoto, J.5    Cable, A.6
  • 17
    • 29244460597 scopus 로고    scopus 로고
    • Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments
    • Y. Yasuno, V. D. Madjarova, S. Makita, M. Akiba, A. Morosawa, C. Chong, T. Sakai, K. P. Chan, M. Itoh, and T. Yatagai, "Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments," Opt. Express 13(26), 10652-10664 (2005).
    • (2005) Opt. Express , vol.13 , Issue.26 , pp. 10652-10664
    • Yasuno, Y.1    Madjarova, V.D.2    Makita, S.3    Akiba, M.4    Morosawa, A.5    Chong, C.6    Sakai, T.7    Chan, K.P.8    Itoh, M.9    Yatagai, T.10
  • 18
    • 21244433547 scopus 로고    scopus 로고
    • Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: Design and scaling principles
    • R. Huber, M. Wojtkowski, K. Taira, J. G. Fujimoto, and K. Hsu, "Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles," Opt. Express 13(9), 3513- 3528 (2005).
    • (2005) Opt. Express , vol.13 , Issue.9 , pp. 3513-3528
    • Huber, R.1    Wojtkowski, M.2    Taira, K.3    Fujimoto, J.G.4    Hsu, K.5
  • 19
    • 70350341720 scopus 로고    scopus 로고
    • Wavelength swept amplified spontaneous emission source
    • C. M. Eigenwillig, B. R. Biedermann, W. Wieser, and R. Huber, "Wavelength swept amplified spontaneous emission source," Opt. Express 17(21), 18794-18807 (2009).
    • (2009) Opt. Express , vol.17 , Issue.21 , pp. 18794-18807
    • Eigenwillig, C.M.1    Biedermann, B.R.2    Wieser, W.3    Huber, R.4
  • 20
    • 79960639422 scopus 로고    scopus 로고
    • Wavelength swept amplified spontaneous emission source for high speed retinal optical coherence tomography at 1060 nm
    • C. M. Eigenwillig, T. Klein, W. Wieser, B. R. Biedermann, and R. Huber, "Wavelength swept amplified spontaneous emission source for high speed retinal optical coherence tomography at 1060 nm," J Biophotonics 4(7-8), 552-558 (2011).
    • (2011) J Biophotonics , vol.4 , Issue.7-8 , pp. 552-558
    • Eigenwillig, C.M.1    Klein, T.2    Wieser, W.3    Biedermann, B.R.4    Huber, R.5
  • 21
    • 70349321160 scopus 로고    scopus 로고
    • Recent developments in Fourier domain mode locked lasers for optical coherence tomography: Imaging at 1310 nm vs. 1550 nm wavelength
    • B. R. Biedermann, W. Wieser, C. M. Eigenwillig, and R. Huber, "Recent developments in Fourier domain mode locked lasers for optical coherence tomography: imaging at 1310 nm vs. 1550 nm wavelength," J Biophotonics 2(6-7), 357-363 (2009).
    • (2009) J Biophotonics , vol.2 , Issue.6-7 , pp. 357-363
    • Biedermann, B.R.1    Wieser, W.2    Eigenwillig, C.M.3    Huber, R.4
  • 22
    • 0001395165 scopus 로고    scopus 로고
    • Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:Forsterite laser
    • B. Golubovic, B. E. Bouma, G. J. Tearney, and J. G. Fujimoto, "Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser," Opt. Lett. 22(22), 1704-1706 (1997).
    • (1997) Opt. Lett , vol.22 , Issue.22 , pp. 1704-1706
    • Golubovic, B.1    Bouma, B.E.2    Tearney, G.J.3    Fujimoto, J.G.4
  • 24
    • 77954950579 scopus 로고    scopus 로고
    • Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second
    • W. Wieser, B. R. Biedermann, T. Klein, C. M. Eigenwillig, and R. Huber, "Multi-megahertz OCT: high quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second," Opt. Express 18(14), 14685-14704 (2010).
    • (2010) Opt. Express , vol.18 , Issue.14 , pp. 14685-14704
    • Wieser, W.1    Biedermann, B.R.2    Klein, T.3    Eigenwillig, C.M.4    Huber, R.5
  • 25
    • 79951610223 scopus 로고    scopus 로고
    • Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm Fourier domain mode-locked laser
    • T. Klein, W. Wieser, C. M. Eigenwillig, B. R. Biedermann, and R. Huber, "Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm Fourier domain mode-locked laser," Opt. Express 19(4), 3044-3062 (2011).
    • (2011) Opt. Express , vol.19 , Issue.4 , pp. 3044-3062
    • Klein, T.1    Wieser, W.2    Eigenwillig, C.M.3    Biedermann, B.R.4    Huber, R.5
  • 26
    • 77951535491 scopus 로고    scopus 로고
    • Ultra broad band Fourier domain mode locked swept source based on dual SOAs and WDM couplers
    • J. Zhang, G. J. Liu, and Z. P. Chen, "Ultra broad band Fourier domain mode locked swept source based on dual SOAs and WDM couplers," Proc. SPIE 7554, 75541I, 75541I-5 (2010).
    • (2010) Proc. SPIE , vol.7554
    • Zhang, J.1    Liu, G.J.2    Chen, Z.P.3
  • 27
    • 65349097954 scopus 로고    scopus 로고
    • High-power 1300 nm FDML swept laser using polygon- based narrowband optical scanning filter
    • Y. X. Mao, C. Flueraru, S. D. Chang, and S. Sherif, "High-power 1300 nm FDML swept laser using polygon- based narrowband optical scanning filter," Proc. SPIE 7168, 716822, 716822-8 (2009).
    • (2009) Proc. SPIE , vol.7168
    • Mao, Y.X.1    Flueraru, C.2    Chang, S.D.3
  • 29
    • 80053955053 scopus 로고    scopus 로고
    • Extended coherence length Fourier domain mode locked lasers at 1310 nm
    • D. C. Adler, W. Wieser, F. Trepanier, J. M. Schmitt, and R. A. Huber, "Extended coherence length Fourier domain mode locked lasers at 1310 nm," Opt. Express 19(21), 20930-20939 (2011).
    • (2011) Opt. Express , vol.19 , Issue.21 , pp. 20930-20939
    • Adler, D.C.1    Wieser, W.2    Trepanier, F.3    Schmitt, J.M.4    Huber, R.A.5
  • 30
    • 78651514343 scopus 로고    scopus 로고
    • Optical coherence tomography and Doppler optical coherence tomography in the gastrointestinal tract
    • E. Osiac, A. Sǎftoiu, D. I. Gheonea, I. Mandrila, and R. Angelescu, "Optical coherence tomography and Doppler optical coherence tomography in the gastrointestinal tract," World J. Gastroenterol. 17(1), 15-20 (2011).
    • (2011) World J. Gastroenterol , vol.17 , Issue.1 , pp. 15-20
    • Osiac, E.1    Sǎftoiu, A.2    Gheonea, D.I.3    Mandrila, I.4    Angelescu, R.5
  • 32
    • 84883892407 scopus 로고    scopus 로고
    • Analysis of the signal fall-off in spectral domain optical coherence tomography systems
    • 8213, 82131K
    • M. Hagen-Eggert, P. Koch, and G. Huttmann, "Analysis of the signal fall-off in spectral domain optical coherence tomography systems," Proc. SPIE 8213, 82131K, 82131K-7 (2012).
    • (2012) Proc. SPIE
    • Hagen-Eggert, M.1    Koch, P.2    Huttmann, G.3
  • 33
    • 84866649032 scopus 로고    scopus 로고
    • MEMS tunable VCSEL light source for ultrahigh speed 60kHz-1MHz axial scan rate and long range centimeter class OCT imaging
    • B. Potsaid, V. Jayaraman, J. G. Fujimoto, J. Jiang, P. J. S. Heim, and A. E. Cable, "MEMS tunable VCSEL light source for ultrahigh speed 60kHz-1MHz axial scan rate and long range centimeter class OCT imaging," Proc. SPIE 8213, 82130M (2012).
    • (2012) Proc. SPIE , vol.8213
    • Potsaid, B.1    Jayaraman, V.2    Fujimoto, J.G.3    Jiang, J.4    Heim, P.J.S.5    Cable, A.E.6
  • 35
    • 79958082133 scopus 로고    scopus 로고
    • High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second
    • L. An, G. Guan, and R. K. Wang, "High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second," J. Biomed. Opt. 16(6), 060506 (2011).
    • (2011) J. Biomed. Opt , vol.16 , Issue.6 , pp. 060506
    • An, L.1    Guan, G.2    Wang, R.K.3
  • 36
    • 84863753268 scopus 로고    scopus 로고
    • High speed spectral domain optical coherence tomography for retinal imaging at 500,000 A-lines per second
    • L. An, P. Li, T. T. Shen, and R. Wang, "High speed spectral domain optical coherence tomography for retinal imaging at 500,000 A-lines per second," Biomed. Opt. Express 2(10), 2770-2783 (2011).
    • (2011) Biomed. Opt. Express , vol.2 , Issue.10 , pp. 2770-2783
    • An, L.1    Li, P.2    Shen, T.T.3    Wang, R.4
  • 38
    • 77956322120 scopus 로고    scopus 로고
    • 400 kHz repetition rate wavelengthswept laser and application to high-speed optical frequency domain imaging
    • W.-Y. Oh, B. J. Vakoc, M. Shishkov, G. J. Tearney, and B. E. Bouma, ">400 kHz repetition rate wavelengthswept laser and application to high-speed optical frequency domain imaging," Opt. Lett. 35(17), 2919-2921 (2010).
    • (2010) Opt. Lett , vol.35 , Issue.17 , pp. 2919-2921
    • Oh, W.-Y.1    Vakoc, B.J.2    Shishkov, M.3    Tearney, G.J.4    Bouma, B.E.5
  • 39
    • 78549242994 scopus 로고    scopus 로고
    • In vivo Fourier-domain full-field OCT of the human retina with 1.5 million A-lines/s
    • T. Bonin, G. Franke, M. Hagen-Eggert, P. Koch, and G. Hüttmann, "In vivo Fourier-domain full-field OCT of the human retina with 1.5 million A-lines/s," Opt. Lett. 35(20), 3432-3434 (2010).
    • (2010) Opt. Lett , vol.35 , Issue.20 , pp. 3432-3434
    • Bonin, T.1    Franke, G.2    Hagen-Eggert, M.3    Koch, P.4    Hüttmann, G.5
  • 40
    • 46149095079 scopus 로고    scopus 로고
    • Fourier domain optical coherence tomography using optical demultiplexers imaging at 60,000,000 lines/s
    • D. Choi, H. Hiro-Oka, H. Furukawa, R. Yoshimura, M. Nakanishi, K. Shimizu, and K. Ohbayashi, "Fourier domain optical coherence tomography using optical demultiplexers imaging at 60,000,000 lines/s," Opt. Lett. 33(12), 1318-1320 (2008).
    • (2008) Opt. Lett , vol.33 , Issue.12 , pp. 1318-1320
    • Choi, D.1    Hiro-Oka, H.2    Furukawa, H.3    Yoshimura, R.4    Nakanishi, M.5    Shimizu, K.6    Ohbayashi, K.7
  • 41
    • 84860739908 scopus 로고    scopus 로고
    • 4D imaging of embryonic chick hearts by streak-mode Fourier domain optical coherence tomography
    • 8207, 82073V, 82073V-6
    • R. Wang, J. X. Yun, R. Goodwin, R. Markwald, T. K. Borg, R. B. Runyan, and B. Gao, "4D imaging of embryonic chick hearts by streak-mode Fourier domain optical coherence tomography," Proc. SPIE 8207, 82073V, 82073V-6 (2012).
    • (2012) Proc. SPIE
    • Wang, R.1    Yun, J.X.2    Goodwin, R.3    Markwald, R.4    Borg, T.K.5    Runyan, R.B.6    Gao, B.7
  • 42
    • 80455141568 scopus 로고    scopus 로고
    • Megahertz streak-mode Fourier domain optical coherence tomography
    • R. Wang, J. X. Yun, X. Yuan, R. Goodwin, R. R. Markwald, and B. Z. Gao, "Megahertz streak-mode Fourier domain optical coherence tomography," J. Biomed. Opt. 16(6), 066016 (2011).
    • (2011) J. Biomed. Opt , vol.16 , Issue.6 , pp. 066016
    • Wang, R.1    Yun, J.X.2    Yuan, X.3    Goodwin, R.4    Markwald, R.R.5    Gao, B.Z.6
  • 43
    • 66849087514 scopus 로고    scopus 로고
    • Dispersion, coherence and noise of Fourier domain mode locked lasers
    • B. R. Biedermann, W. Wieser, C. M. Eigenwillig, T. Klein, and R. Huber, "Dispersion, coherence and noise of Fourier domain mode locked lasers," Opt. Express 17(12), 9947-9961 (2009).
    • (2009) Opt. Express , vol.17 , Issue.12 , pp. 9947-9961
    • Biedermann, B.R.1    Wieser, W.2    Eigenwillig, C.M.3    Klein, T.4    Huber, R.5
  • 46
    • 45449111633 scopus 로고    scopus 로고
    • K-space linear Fourier domain mode locked laser and applications for optical coherence tomography
    • C. M. Eigenwillig, B. R. Biedermann, G. Palte, and R. Huber, "K-space linear Fourier domain mode locked laser and applications for optical coherence tomography," Opt. Express 16(12), 8916-8937 (2008).
    • (2008) Opt. Express , vol.16 , Issue.12 , pp. 8916-8937
    • Eigenwillig, C.M.1    Biedermann, B.R.2    Palte, G.3    Huber, R.4
  • 48
    • 84867253024 scopus 로고    scopus 로고
    • Multi-MHz FDML OCT: Snapshot retinal imaging at 6.7 million axial-scans per second
    • T. Klein, W. Wieser, R. Andre, T. Pfeiffer, C. M. Eigenwillig, and R. Huber, "Multi-MHz FDML OCT: snapshot retinal imaging at 6.7 million axial-scans per second," Proc. SPIE 8213, 82131E, 82131E-6 (2012).
    • (2012) Proc. SPIE
    • Klein, T.1    Wieser, W.2    Andre, R.3    Pfeiffer, T.4    Eigenwillig, C.M.5    Huber, R.6
  • 50
    • 69049105425 scopus 로고    scopus 로고
    • Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range
    • M. Gora, K. Karnowski, M. Szkulmowski, B. J. Kaluzny, R. Huber, A. Kowalczyk, and M. Wojtkowski, "Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range," Opt. Express 17(17), 14880-14894 (2009).
    • (2009) Opt. Express , vol.17 , Issue.17 , pp. 14880-14894
    • Gora, M.1    Karnowski, K.2    Szkulmowski, M.3    Kaluzny, B.J.4    Huber, R.5    Kowalczyk, A.6    Wojtkowski, M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.