메뉴 건너뛰기




Volumn 8207, Issue , 2012, Pages

4D imaging of embryonic chick hearts by streak-mode Fourier domain optical coherence tomography

Author keywords

Fourier domain; Heart development; Optical coherence tomography; Streak mode

Indexed keywords

4D IMAGING; DATA SETS; FOURIER DOMAIN OPTICAL COHERENCE TOMOGRAPHY; FOURIER DOMAINS; FRAMES PER SECONDS; GATING TECHNIQUES; HEART DEVELOPMENT; HIGH TEMPORAL RESOLUTION; STREAK MODE; ULTRA HIGH SPEED;

EID: 84860739908     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.907156     Document Type: Conference Paper
Times cited : (4)

References (19)
  • 2
    • 0029762944 scopus 로고    scopus 로고
    • Doppler echocardiography of normal and abnormal embryonic mouse heart
    • Y. H. Gui, K. K. Linask, P. Khowsathit, and J. C. Huhta, "Doppler echocardiography of normal and abnormal embryonic mouse heart, " Pediatric Research 40, 633-642 (1996).
    • (1996) Pediatric Research , vol.40 , pp. 633-642
    • Gui, Y.H.1    Linask, K.K.2    Khowsathit, P.3    Huhta, J.C.4
  • 3
    • 0018253802 scopus 로고
    • Spectrum of cardiovascular anomalies following cardiac loop constriction in the chick embryo
    • E. B. Clark and G. C. Rosenquist, "Spectrum of cardiovascular anomalies following cardiac loop constriction in the chick embryo, " Birth Defects Orig Artic Ser 14, 431-442 (1978).
    • (1978) Birth Defects Orig Artic Ser , vol.14 , pp. 431-442
    • Clark, E.B.1    Rosenquist, G.C.2
  • 4
    • 0032907607 scopus 로고    scopus 로고
    • Extraembryonic venous obstructions lead to cardiovascular malformations and can be embryolethal
    • B. Hogers, M. C. DeRuiter, A. C. Gittenberger-de Groot, and R. E. Poelmann, "Extraembryonic venous obstructions lead to cardiovascular malformations and can be embryolethal, " Cardiovascular Research 41, 87-99 (1999).
    • (1999) Cardiovascular Research , vol.41 , pp. 87-99
    • Hogers, B.1    Deruiter, M.C.2    De Groot, A.C.G.3    Poelmann, R.E.4
  • 6
    • 0346634892 scopus 로고    scopus 로고
    • Intracardiac fluid forces are an essential epigenetic factor for embryonic cardiogenesis
    • J. R. Hove, R. W. Koster, A. S. Forouhar, G. Acevedo-Bolton, S. E. Fraser, and M. Gharib, "Intracardiac fluid forces are an essential epigenetic factor for embryonic cardiogenesis, " Nature 421, 172-177 (2003).
    • (2003) Nature , vol.421 , pp. 172-177
    • Hove, J.R.1    Koster, R.W.2    Forouhar, A.S.3    Acevedo-Bolton, G.4    Fraser, S.E.5    Gharib, M.6
  • 8
    • 20444456745 scopus 로고    scopus 로고
    • Arterial hemodynamics and mechanical properties after circulatory intervention in the chick embryo
    • J. L. Lucitti, K. Tobita, and B. B. Keller, "Arterial hemodynamics and mechanical properties after circulatory intervention in the chick embryo, " Journal of Experimental Biology 208, 1877-1885 (2005).
    • (2005) Journal of Experimental Biology , vol.208 , pp. 1877-1885
    • Lucitti, J.L.1    Tobita, K.2    Keller, B.B.3
  • 9
    • 51849135956 scopus 로고    scopus 로고
    • Changes in wall motion and blood flow in the outflow tract of chick embryonic hearts observed with optical coherence tomography after outflow tract banding and vitelline-vein ligation
    • S. Rugonyi, C. Shaut, A. P. Liu, K. Thornburg, and R. K. K. Wang, "Changes in wall motion and blood flow in the outflow tract of chick embryonic hearts observed with optical coherence tomography after outflow tract banding and vitelline-vein ligation, " Phys Med Biol 53, 5077-5091 (2008).
    • (2008) Phys Med Biol , vol.53 , pp. 5077-5091
    • Rugonyi, S.1    Shaut, C.2    Liu, A.P.3    Thornburg, K.4    Wang, R.K.K.5
  • 11
    • 0038707943 scopus 로고    scopus 로고
    • Cardiac chamber formation: Development, genes, and evolution
    • A. F. M. Moorman and V. M. Christoffels, "Cardiac chamber formation: Development, genes, and evolution, " Physiological Reviews 83, 1223-1267 (2003).
    • (2003) Physiological Reviews , vol.83 , pp. 1223-1267
    • Moorman, A.F.M.1    Christoffels, V.M.2
  • 16
    • 0038618462 scopus 로고    scopus 로고
    • Performance of fourier domain vs. Time domain optical coherence tomography
    • R. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, "Performance of fourier domain vs. time domain optical coherence tomography, " Optics Express 11, 889-894 (2003).
    • (2003) Optics Express , vol.11 , pp. 889-894
    • Leitgeb, R.1    Hitzenberger, C.K.2    Fercher, A.F.3
  • 17
    • 0000150646 scopus 로고    scopus 로고
    • Optimal interferometer designs for optical coherence tomography
    • A. M. Rollins and J. A. Izatt, "Optimal interferometer designs for optical coherence tomography, " Optics Letters 24, 1484-1486 (1999).
    • (1999) Optics Letters , vol.24 , pp. 1484-1486
    • Rollins, A.M.1    Izatt, J.A.2
  • 18
    • 0031695986 scopus 로고    scopus 로고
    • Coherence radar" and "spectral radar"-new tools for dermatological diagnosis
    • G. Häusler and M. W. Lindner, ""Coherence Radar" and "Spectral Radar"-New Tools for Dermatological Diagnosis, " J. Biomed. Opt. 3, 21 (1998).
    • (1998) J. Biomed. Opt. , vol.3 , pp. 21
    • Häusler, G.1    Lindner, M.W.2
  • 19
    • 77950679704 scopus 로고    scopus 로고
    • V3D enables real-time 3D visualization and quantitative analysis of large-scale biological image data sets
    • H. C. Peng, Z. C. Ruan, F. H. Long, J. H. Simpson, and E. W. Myers, "V3D enables real-time 3D visualization and quantitative analysis of large-scale biological image data sets, " Nature Biotechnology 28, 348-U375 (2010).
    • (2010) Nature Biotechnology , vol.28
    • Peng, H.C.1    Ruan, Z.C.2    Long, F.H.3    Simpson, J.H.4    Myers, E.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.