메뉴 건너뛰기




Volumn 68, Issue 4, 2012, Pages 1166-1175

Null space imaging: Nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging

Author keywords

accelerated imaging; nonlinear gradient encoding; parallel imaging; receiver coil complementarity; singular value decomposition

Indexed keywords

EFFICIENCY; ENCODING (SYMBOLS); IMAGE ACQUISITION; MAGNETIC FIELDS; MEAN SQUARE ERROR; SINGULAR VALUE DECOMPOSITION; VECTOR SPACES;

EID: 84866730095     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24114     Document Type: Article
Times cited : (37)

References (35)
  • 1
    • 0027173207 scopus 로고
    • Imaging time reduction through multiple receiver coil data acquisition and image-reconstruction
    • Carlson JW, Minemura T,. Imaging time reduction through multiple receiver coil data acquisition and image-reconstruction. Magn Reson Med 1993; 29: 681-688.
    • (1993) Magn Reson Med , vol.29 , pp. 681-688
    • Carlson, J.W.1    Minemura, T.2
  • 2
    • 0025777470 scopus 로고
    • A decoupled coil detector array for fast image acquisition in magnetic-resonance-imaging
    • Kwiat D, Einav S, Navon G,. A decoupled coil detector array for fast image acquisition in magnetic-resonance-imaging. Med Phys 1991; 18: 251-265.
    • (1991) Med Phys , vol.18 , pp. 251-265
    • Kwiat, D.1    Einav, S.2    Navon, G.3
  • 5
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ,. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 6
    • 33744530417 scopus 로고    scopus 로고
    • Encoding and reconstruction in parallel MRI
    • Pruessmann KP,. Encoding and reconstruction in parallel MRI. NMR Biomed 2006; 19: 288-299.
    • (2006) NMR Biomed , vol.19 , pp. 288-299
    • Pruessmann, K.P.1
  • 7
    • 0034845169 scopus 로고    scopus 로고
    • A generalized approach to parallel magnetic resonance imaging
    • Sodickson DK, McKenzie CA,. A generalized approach to parallel magnetic resonance imaging. Med Phys 2001; 28: 1629-1643.
    • (2001) Med Phys , vol.28 , pp. 1629-1643
    • Sodickson, D.K.1    McKenzie, C.A.2
  • 10
    • 0025222892 scopus 로고
    • Computer modeling of surface coil sensitivity
    • Lawry TJ, Weiner MW, Matson GB,. Computer modeling of surface coil sensitivity. Magn Reson Med 1990; 16: 294-302.
    • (1990) Magn Reson Med , vol.16 , pp. 294-302
    • Lawry, T.J.1    Weiner, M.W.2    Matson, G.B.3
  • 12
    • 77955112765 scopus 로고    scopus 로고
    • O-space imaging: Highly efficient parallel imaging using second-order nonlinear fields as encoding gradients with no phase encoding
    • Stockmann JP, Ciris PA, Galiana G, Tam L, Constable RT,. O-space imaging: highly efficient parallel imaging using second-order nonlinear fields as encoding gradients with no phase encoding. Magn Reson Med 2010; 64: 447-456.
    • (2010) Magn Reson Med , vol.64 , pp. 447-456
    • Stockmann, J.P.1    Ciris, P.A.2    Galiana, G.3    Tam, L.4    Constable, R.T.5
  • 15
    • 78349235374 scopus 로고    scopus 로고
    • Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, nonbijective magnetic fields
    • Schultz G, Ullmann P, Lehr H, Welz AM, Hennig J, Zaitsev M,. Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, nonbijective magnetic fields. Magn Reson Med 2010; 64: 1390-1404.
    • (2010) Magn Reson Med , vol.64 , pp. 1390-1404
    • Schultz, G.1    Ullmann, P.2    Lehr, H.3    Welz, A.M.4    Hennig, J.5    Zaitsev, M.6
  • 16
    • 0004236492 scopus 로고    scopus 로고
    • Baltimore: Johns Hopkins University Press
    • Golub GH, Van Loan CF,. Matrix computations. Baltimore: Johns Hopkins University Press; 1996. pp 470-499.
    • (1996) Matrix Computations , pp. 470-499
    • Golub, G.H.1    Van Loan, C.F.2
  • 19
    • 0021749809 scopus 로고
    • Magnet field profiling-analysis and correcting coil design
    • Romeo F, Hoult DI,. Magnet field profiling-analysis and correcting coil design. Magn Reson Med 1984; 1: 44-65.
    • (1984) Magn Reson Med , vol.1 , pp. 44-65
    • Romeo, F.1    Hoult, D.I.2
  • 21
    • 0030726765 scopus 로고    scopus 로고
    • Measurement of the point spread function in MRI using constant time imaging
    • Robson MD, Gore JC, Constable RT,. Measurement of the point spread function in MRI using constant time imaging. Magn Reson Med 1997; 38: 733-740.
    • (1997) Magn Reson Med , vol.38 , pp. 733-740
    • Robson, M.D.1    Gore, J.C.2    Constable, R.T.3
  • 22
    • 7544248836 scopus 로고    scopus 로고
    • Point spread function mapping with parallel imaging techniques and high acceleration factors: Fast, robust, and flexible method for echo-planar imaging distortion correction
    • Zaitsev M, Hennig J, Speck O,. Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction. Magn Reson Med 2004; 52: 1156-1166.
    • (2004) Magn Reson Med , vol.52 , pp. 1156-1166
    • Zaitsev, M.1    Hennig, J.2    Speck, O.3
  • 23
    • 0036296026 scopus 로고    scopus 로고
    • Image distortion correction in EPI: Comparison of field mapping with point spread function mapping
    • Zeng HR, Constable RT,. Image distortion correction in EPI: comparison of field mapping with point spread function mapping. Magn Reson Med 2002; 48: 137-146.
    • (2002) Magn Reson Med , vol.48 , pp. 137-146
    • Zeng, H.R.1    Constable, R.T.2
  • 24
    • 79251563181 scopus 로고    scopus 로고
    • Robust spatially selective excitation using radiofrequency pulses adapted to the effective spatially encoding magnetic fields
    • Schneider JT, Haas M, Ruhm W, Hennig J, Ullmann P,. Robust spatially selective excitation using radiofrequency pulses adapted to the effective spatially encoding magnetic fields. Magn Reson Med 2011; 65: 409-421.
    • (2011) Magn Reson Med , vol.65 , pp. 409-421
    • Schneider, J.T.1    Haas, M.2    Ruhm, W.3    Hennig, J.4    Ullmann, P.5
  • 25
    • 84968519566 scopus 로고
    • The Lanczos-Algorithm with partial reorthogonalization
    • Simon HD,. The Lanczos-Algorithm with partial reorthogonalization. Math Comp 1984; 42: 115-142.
    • (1984) Math Comp , vol.42 , pp. 115-142
    • Simon, H.D.1
  • 27
    • 1542346911 scopus 로고    scopus 로고
    • Parallel imaging reconstruction using automatic regularization
    • Lin FH, Kwong KK, Belliveau JW, Wald LL,. Parallel imaging reconstruction using automatic regularization. Magn Reson Med 2004; 51: 559-567.
    • (2004) Magn Reson Med , vol.51 , pp. 559-567
    • Lin, F.H.1    Kwong, K.K.2    Belliveau, J.W.3    Wald, L.L.4
  • 28
    • 0017103820 scopus 로고
    • Iterative reconstruction algorithms
    • Herman GT, Lent A,. Iterative reconstruction algorithms. Comput Biol Med 1976; 6: 273-294.
    • (1976) Comput Biol Med , vol.6 , pp. 273-294
    • Herman, G.T.1    Lent, A.2
  • 29
    • 0030013913 scopus 로고    scopus 로고
    • Dynamic shim updating: A new approach towards optimized whole brain shimming
    • Blamire AM, Rothman DL, Nixon T,. Dynamic shim updating: a new approach towards optimized whole brain shimming. Magn Reson Med 1996; 36: 159-165.
    • (1996) Magn Reson Med , vol.36 , pp. 159-165
    • Blamire, A.M.1    Rothman, D.L.2    Nixon, T.3
  • 31
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Boesiger P, Pruessmann KP, Weiger M, Bornert P,. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001; 46: 638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Boesiger, P.1    Pruessmann, K.P.2    Weiger, M.3    Bornert, P.4
  • 32
    • 3543128963 scopus 로고    scopus 로고
    • UNFOLD-SENSE: A parallel MRI method with self-calibration and artifact suppression
    • Madore B,. UNFOLD-SENSE: a parallel MRI method with self-calibration and artifact suppression. Magn Reson Med 2004; 52: 310-320.
    • (2004) Magn Reson Med , vol.52 , pp. 310-320
    • Madore, B.1
  • 33
    • 36149042452 scopus 로고
    • Multi-planar image-formation using NMR spin echoes
    • Mansfield P,. Multi-planar image-formation using NMR spin echoes. J Phys C Solid State 1977; 10: L55-L58.
    • (1977) J Phys C Solid State , vol.10
    • Mansfield, P.1
  • 34
    • 0022872540 scopus 로고
    • Rare imaging-A fast imaging method for clinical MR
    • Hennig J, Nauerth A, Friedburg H,. Rare imaging-a fast imaging method for clinical MR. Magn Reson Med 1986; 3: 823-833.
    • (1986) Magn Reson Med , vol.3 , pp. 823-833
    • Hennig, J.1    Nauerth, A.2    Friedburg, H.3
  • 35
    • 0000369227 scopus 로고
    • Steady-state free precession in nuclear magnetic resonance
    • Carr HY,. Steady-state free precession in nuclear magnetic resonance. Phys Rev 1958; 112: 1693-1701.
    • (1958) Phys Rev , vol.112 , pp. 1693-1701
    • Carr, H.Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.