Silicate-substituted calcium phosphate ceramic bone graft replacement for spinal fusion procedures

Author keywords

ceramic; fusion; silicate substituted calcium phosphate; bone graft substitute; spinal; spine; surgery

Indexed keywords

ANTIBIOTIC AGENT; BONE MORPHOGENETIC PROTEIN; CALCIUM PHOSPHATE CERAMIC; SILICATE CEMENT;

EID: 84866534141     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e318265e22e     Document Type: Article
Times cited : (43)

References (53)
  • 2
    • 0034198607 scopus 로고    scopus 로고
    • Iliac crest autogenous bone grafting: Donor site complications
    • Seiler JG, Johnson J . Iliac crest autogenous bone grafting: Donor site complications . J South Orthop Assoc. 2000; 9 : 91 - 7.
    • (2000) J South Orthop Assoc , vol.9 , pp. 91-97
    • Seiler, J.G.1    Johnson, J.2
  • 5
    • 36248939717 scopus 로고    scopus 로고
    • Allograft update: The current status of tissue regulation, procurement, processing, and sterilization
    • DOI 10.1177/0363546507308936
    • McAllister DR, Joyce MJ, Mann BJ, et al . Allograft update: The current status of tissue regulation, procurement, processing, and sterilization . Am J Sports Med 2007; 35 : 2148 - 58. (Pubitemid 350125812)
    • (2007) American Journal of Sports Medicine , vol.35 , Issue.12 , pp. 2148-2158
    • McAllister, D.R.1    Joyce, M.J.2    Mann, B.J.3    Vangsness Jr., C.T.4
  • 6
    • 0025973096 scopus 로고
    • The effect of hydroxyapatite coating on ingrowth of bone into cavities in an implant
    • Stephenson PK, Freeman MA, Revell PA, et al . The effect of hydroxyapatite coating on ingrowth of bone into cavities in an implant . J Arthroplasty 1991; 6 : 51 - 8.
    • (1991) J Arthroplasty , vol.6 , pp. 51-58
    • Stephenson, P.K.1    Freeman, M.A.2    Revell, P.A.3
  • 7
    • 0026521288 scopus 로고
    • Hydroxyapatite coating modifi es implant membrane formation. Controlled micromotion studied in dogs
    • Søballe K, Brockstedt-Rasmussen H, Hansen ES, et al . Hydroxyapatite coating modifi es implant membrane formation. Controlled micromotion studied in dogs . Acta Orthop Scand 1992; 63 : 128 - 40.
    • (1992) Acta Orthop Scand , vol.63 , pp. 128-140
    • Søballe, K.1    Brockstedt-Rasmussen, H.2    Hansen, E.S.3
  • 8
    • 43149125041 scopus 로고    scopus 로고
    • Single-level instrumented posterolateral fusion of lumbar spine with beta-tricalcium phosphate versus autograft: A prospective, randomized study with 3-year follow-up
    • Dai LY, Jiang LS . Single-level instrumented posterolateral fusion of lumbar spine with beta-tricalcium phosphate versus autograft: A prospective, randomized study with 3-year follow-up . Spine (Phila Pa 1976) 2008 ; 33 : 1299 - 304.
    • (2008) Spine (Phila Pa 1976) , vol.33 , pp. 1299-1304
    • Dai, L.Y.1    Jiang, L.S.2
  • 9
    • 54449083398 scopus 로고    scopus 로고
    • An analysis of noninstrumented posterolateral lumbar fusions performed in predominantly geriatric patients using lamina autograft and beta tricalcium phosphate
    • Epstein NE . An analysis of noninstrumented posterolateral lumbar fusions performed in predominantly geriatric patients using lamina autograft and beta tricalcium phosphate . Spine J 2008; 8 : 882 - 7.
    • (2008) Spine J , vol.8 , pp. 882-887
    • Epstein, N.E.1
  • 10
    • 67651083427 scopus 로고    scopus 로고
    • Beta tricalcium phosphate: Observation of use in 100 posterolateral lumbar instrumented fusions
    • Epstein NE . Beta tricalcium phosphate: Observation of use in 100 posterolateral lumbar instrumented fusions . Spine J 2009; 9 : 630 - 8.
    • (2009) Spine J , vol.9 , pp. 630-638
    • Epstein, N.E.1
  • 11
    • 41949127907 scopus 로고    scopus 로고
    • Hydroxyapatite-bioactive glass ceramic composite as stand-alone graft substitute for posterolateral fusion of lumbar spine: A prospective, matched, and controlled study
    • DOI 10.1097/BSD.0b013e31805fea1f, PII 0002472020080400000006
    • Acharya NK, Kumar RJ, Varma HK, et al . Hydroxyapatite-bioactive glass ceramic composite as stand-alone graft substitute for posterolateral fusion of lumbar spine: A prospective, matched, and controlled study . J Spinal Disord Tech 2008; 21 : 106 - 11. (Pubitemid 351507599)
    • (2008) Journal of Spinal Disorders and Techniques , vol.21 , Issue.2 , pp. 106-111
    • Acharya, N.K.1    Kumar, R.J.2    Varma, H.K.3    Menon, V.K.4
  • 12
    • 0041416155 scopus 로고    scopus 로고
    • Instrumented posterolateral lumbar fusion using coralline hydroxyapatite with or without demineralized bone matrix, as an adjunct to autologous bone
    • DOI 10.1016/S1529-9430(01)00011-0, PII S1529943001000110
    • Thalgott JS, Giuffre JM, Fritts K, et al . Instrumented posterolateral lumbar fusion using coralline hydroxyapatite with or without demineralized bone matrix, as an adjunct to autologous bone . Spine J 2001; 1 : 131 - 7. (Pubitemid 33628836)
    • (2001) Spine Journal , vol.1 , Issue.2 , pp. 131-137
    • Thalgott, J.S.1    Giuffre, J.M.2    Fritts, K.3    Timlin, M.4    Klezl, Z.5
  • 13
    • 0036590661 scopus 로고    scopus 로고
    • The role of the osteoconductive scaffold in synthetic bone graft
    • Vaccaro AR . The role of the osteoconductive scaffold in synthetic bone graft . Orthopedics 2002; 25 : S571 - 8. (Pubitemid 36401429)
    • (2002) Orthopedics , vol.25 , Issue.5 SUPPL.
    • Vaccaro, A.R.1
  • 14
    • 10844277457 scopus 로고    scopus 로고
    • Bone repair in the twenty-fi rst century: Biology, chemistry or engineering? Philos Transact A Math Phys
    • Hing KA . Bone repair in the twenty-fi rst century: Biology, chemistry or engineering? Philos Transact A Math Phys Eng Sci 2004; 362 : 2821 - 50.
    • (2004) Eng Sci , vol.362 , pp. 2821-2850
    • Hing, K.A.1
  • 16
    • 0035876206 scopus 로고    scopus 로고
    • Silica-based bioactive glasses modulate expression of bone morphogenetic protein-2 mRNA in Saos-2 osteoblasts in vitro
    • DOI 10.1016/S0142-9612(00)00288-X, PII S014296120000288X
    • Gao T, Aro HT, Ylänen H, et al . Silica-based bioactive glasses modulate expression of bone morphogenetic protein-2 mRNA in Saos-2 osteoblasts in vitro . Biomaterials 2001; 22 : 1475 - 83. (Pubitemid 32573665)
    • (2001) Biomaterials , vol.22 , Issue.12 , pp. 1475-1483
    • Gao, T.1    Aro, H.T.2    Ylanen, H.3    Vuorio, E.4
  • 17
    • 0347130061 scopus 로고    scopus 로고
    • Nodule formation and mineralisation of human primary osteoblasts cultured on a porous bioactive glass scaffold
    • DOI 10.1016/j.biomaterials.2003.07.001
    • Gough JE, Jones JR, Hench LL . Nodule formation and mineralisation of human primary osteoblasts cultured on a porous bioactive glass scaffold . Biomaterials 2004; 25 : 2039 - 46. (Pubitemid 38102404)
    • (2004) Biomaterials , vol.25 , Issue.11 , pp. 2039-2046
    • Gough, J.E.1    Jones, J.R.2    Hench, L.L.3
  • 19
    • 0033558890 scopus 로고    scopus 로고
    • Chemical characterization of silicon-substituted hydroxyapatite
    • DOI 10.1002/(SICI)1097-4636(19990315)44:4<422::AID-JBM8>3.0.CO;2-#
    • Gibson IR, Best SM, Bonfi eld W . Chemical characterization of silicon-substituted hydroxyapatite . J Biomed Mater Res 1999; 44 : 422 - 8. (Pubitemid 29031125)
    • (1999) Journal of Biomedical Materials Research , vol.44 , Issue.4 , pp. 422-428
    • Gibson, I.R.1    Best, S.M.2    Bonfield, W.3
  • 20
    • 0034055520 scopus 로고    scopus 로고
    • Assessment of resorbable bioactive material for grafting of critical-size cancellous defects
    • Wheeler DL, Eschbach EJ, Hoellrich RG, et al . Assessment of resorbable bioactive material for grafting of critical-size cancellous defects . J Orthop Res 2000; 18 : 140 - 8.
    • (2000) J Orthop Res , vol.18 , pp. 140-148
    • Wheeler, D.L.1    Eschbach, E.J.2    Hoellrich, R.G.3
  • 21
    • 0037377198 scopus 로고    scopus 로고
    • Mechanism of bone-like formation on a bioactive implant in vivo
    • DOI 10.1016/S0142-9612(02)00530-6, PII S0142961202005306
    • De Aza PN, Luklinska ZB, Santos C, et al . Mechanism of bone-like formation on a bioactive implant in vivo . Biomaterials 2003; 24 : 1437 - 45. (Pubitemid 36069110)
    • (2003) Biomaterials , vol.24 , Issue.8 , pp. 1437-1445
    • De Aza, P.N.1    Luklinska, Z.B.2    Santos, C.3    Guitian, F.4    De Aza, S.5
  • 24
    • 26244456422 scopus 로고    scopus 로고
    • Correlative radiological, self-assessment and clinical analysis of evolution in instrumented dorsal and lateral fusion for degenerative lumbar spine disease. Autograft versus coralline hydroxyapatite
    • DOI 10.1007/s00586-004-0855-5
    • Korovessis P, Koureas G, Zacharatos S, et al . Correlative radiological, self-assessment and clinical analysis of evolution in instrumented dorsal and lateral fusion for degenerative lumbar spine disease. Autograft versus coralline hydroxyapatite . Eur Spine J 2005; 14 : 630 - 8. (Pubitemid 41414079)
    • (2005) European Spine Journal , vol.14 , Issue.7 , pp. 630-638
    • Korovessis, P.1    Koureas, G.2    Zacharatos, S.3    Papazisis, Z.4    Lambiris, E.5
  • 26
    • 0015496222 scopus 로고
    • Growth-promoting effects of silicon in rats
    • Schwarz K, Milne DB . Growth-promoting effects of silicon in rats . Nature 1972; 239 : 333 - 4.
    • (1972) Nature , vol.239 , pp. 333-334
    • Schwarz, K.1    Milne, D.B.2
  • 27
    • 34247183162 scopus 로고    scopus 로고
    • Diagnostic accuracy and reliability of fine-cut CT scans with reconstructions to determine the status of an instrumented posterolateral fusion with surgical exploration as reference standard
    • DOI 10.1097/01.brs.0000259808.47104.dd, PII 0000763220070415000011
    • Carreon LY, Djurasovic M, Glassman SD, et al . Diagnostic accuracy and reliability of fi ne-cut CT scans with reconstructions to determine the status of an instrumented posterolateral fusion with surgical exploration as reference standard . Spine (Phila Pa 1976) 2007 ; 32 : 892 - 5. (Pubitemid 46624309)
    • (2007) Spine , vol.32 , Issue.8 , pp. 892-895
    • Carreon, L.Y.1    Djurasovic, M.2    Glassman, S.D.3    Sailer, P.4
  • 28
    • 33646095269 scopus 로고    scopus 로고
    • A novel minimally invasive presacral approach and instrumentation technique for anterior L5-S1 intervertebral discectomy and fusion: Technical description and case presentations
    • Marotta N, Cosar M, Pimenta L, et al . A novel minimally invasive presacral approach and instrumentation technique for anterior L5-S1 intervertebral discectomy and fusion: Technical description and case presentations. Neurosurg Focus 2006; 20 : E9.
    • (2006) Neurosurg Focus , vol.20
    • Marotta, N.1    Cosar, M.2    Pimenta, L.3
  • 29
    • 33745649897 scopus 로고    scopus 로고
    • Extreme Lateral Interbody Fusion (XLIF): A novel surgical technique for anterior lumbar interbody fusion
    • DOI 10.1016/j.spinee.2005.08.012, PII S1529943005008703
    • Ozgur BM, Aryan HE, Pimenta L, et al . Extreme Lateral Interbody Fusion (XLIF): A novel surgical technique for anterior lumbar interbody fusion . Spine J 2006; 6 : 435 - 43. (Pubitemid 43964530)
    • (2006) Spine Journal , vol.6 , Issue.4 , pp. 435-443
    • Ozgur, B.M.1    Aryan, H.E.2    Pimenta, L.3    Taylor, W.R.4
  • 30
    • 84924638714 scopus 로고
    • The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion
    • Smith GW, Robinson RA . The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion . J Bone Joint Surg Am 1958 ; 40 -A: 607 - 24.
    • (1958) J Bone Joint Surg Am , vol.40 A , pp. 607-624
    • Smith, G.W.1    Robinson, R.A.2
  • 32
    • 33645382392 scopus 로고    scopus 로고
    • Silicon dissolution from microporus silicon substituted hydroxyapatite and its effect on osteoblast behaviour
    • Guth K, Buckland T, Hing KA . Silicon dissolution from microporus silicon substituted hydroxyapatite and its effect on osteoblast behaviour . Key Eng Mater 2006;: 117 - 20.
    • (2006) Key Eng Mater , pp. 117-120
    • Guth, K.1    Buckland, T.2    Hing, K.A.3
  • 33
    • 33746995094 scopus 로고    scopus 로고
    • Effect of silicon level on rate, quality and progression of bone healing within silicate-substituted porous hydroxyapatite scaffolds
    • DOI 10.1016/j.biomaterials.2006.05.039, PII S0142961206004601
    • Hing KA, Revell PA, Smith N, et al . Effect of silicon level on rate, quality and progression of bone healing within silicate-substituted porous hydroxyapatite scaffolds . Biomaterials 2006; 27 : 5014 - 26. (Pubitemid 44202357)
    • (2006) Biomaterials , vol.27 , Issue.29 , pp. 5014-5026
    • Hing, K.A.1    Revell, P.A.2    Smith, N.3    Buckland, T.4
  • 34
    • 79953804719 scopus 로고    scopus 로고
    • Increasing strut porosity in silicate-substituted calcium-phosphate bone graft substitutes enhances osteogenesis
    • Campion CR, Chander C, Buckland T, et al . Increasing strut porosity in silicate-substituted calcium-phosphate bone graft substitutes enhances osteogenesis . J Biomed Mater Res B Appl Biomater 2011; 97 : 245 - 54.
    • (2011) J Biomed Mater Res B Appl Biomater , vol.97 , pp. 245-254
    • Campion, C.R.1    Chander, C.2    Buckland, T.3
  • 35
    • 77951696796 scopus 로고    scopus 로고
    • Surface physiochemistry affects protein adsorption to stoichiometric and silicate-substituted microporous hydroxyapatites
    • Guth K, Campion C, Buckland T, et al . Surface physiochemistry affects protein adsorption to stoichiometric and silicate-substituted microporous hydroxyapatites . Adv Eng Mat 2010; 12 : B113 - 21.
    • (2010) Adv Eng Mat , vol.12
    • Guth, K.1    Campion, C.2    Buckland, T.3
  • 36
    • 77449104019 scopus 로고    scopus 로고
    • Effect of silicate-substitution on attachment and early development of human osteoblast-like cells seeded on microporous hydroxyapatite discs
    • Guth K, Campion C, Buckland T, et al . Effect of silicate-substitution on attachment and early development of human osteoblast-like cells seeded on microporous hydroxyapatite discs . Adv Eng Mat 2010; 12 : B26 - 36.
    • (2010) Adv Eng Mat , vol.12
    • Guth, K.1    Campion, C.2    Buckland, T.3
  • 37
    • 84873984706 scopus 로고    scopus 로고
    • A novel method for the directed osteogenic differentiation of human mesenchymal stem/ progenitor cells
    • Noble B, Chander C, Buckland T, et al . A novel method for the directed osteogenic differentiation of human mesenchymal stem/ progenitor cells . Bone 2010; 47 : S128.
    • (2010) Bone , Issue.47
    • Noble, B.1    Chander, C.2    Buckland, T.3
  • 39
    • 23044515982 scopus 로고    scopus 로고
    • Guidelines for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 17: Bone growth stimulators and lumbar fusion
    • Resnick DK, Choudhri TF, Dailey AT, et al. Guidelines for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 17: Bone growth stimulators and lumbar fusion . J Neurosurg Spine 2005; 2 : 737 - 40.
    • (2005) J Neurosurg Spine , vol.2 , pp. 737-740
    • Resnick, D.K.1    Choudhri, T.F.2    Dailey, A.T.3
  • 40
    • 0028809573 scopus 로고
    • Evaluation of lumbar spine fusion plain radiographs versus direct surgical exploration and observation
    • Kant AP, Daum WJ, Dean SM, et al . Evaluation of lumbar spine fusion. Plain radiographs versus direct surgical exploration and observation . Spine (Phila Pa 1976) 1995 ; 20 : 2313 - 7.
    • (1995) Spine (Phila Pa 1976) , Issue.20 , pp. 2313-2317
    • Kant, A.P.1    Daum, W.J.2    Dean, S.M.3
  • 41
    • 0027296665 scopus 로고
    • Can lumbar spine radiographs accurately determine fusion in postoperative patients?: Correlation of routine radiographs with a second surgical look at lumbar fusions
    • Blumenthal SL, Gill K . Can lumbar spine radiographs accurately determine fusion in postoperative patients? Correlation of routine radiographs with a second surgical look at lumbar fusions . Spine (Phila Pa 1976) 1993 ; 18 : 1186 - 9. (Pubitemid 23210768)
    • (1993) Spine , vol.18 , Issue.9 , pp. 1186-1189
    • Blumenthal, S.L.1    Gill, K.2
  • 42
    • 0024535655 scopus 로고
    • Low-back Pain After Lumbar Fusion. Surgical And Computed Tomographic Analysis
    • Laasonen EM, Soini J . Low-back pain after lumbar fusion. Surgical and computed tomographic analysis . Spine (Phila Pa 1976) 1989 ; 14 : 210 - 3.
    • (1989) Spine (Phila Pa 1976) , vol.14 , pp. 210-213
    • Laasonen, E.M.1    Soini, J.2
  • 43
    • 33845779790 scopus 로고    scopus 로고
    • Reliability and agreement between fine-cut CT scans and plain radiography in the evaluation of posterolateral fusions
    • DOI 10.1016/j.spinee.2006.04.005, PII S1529943006001938
    • Carreon LY, Glassman SD, Djurasovic M . Reliability and agreement between fi ne-cut CT scans and plain radiography in the evaluation of posterolateral fusions . Spine J 2007; 7 : 39 - 43. (Pubitemid 46002535)
    • (2007) Spine Journal , vol.7 , Issue.1 , pp. 39-43
    • Carreon, L.Y.1    Glassman, S.D.2    Djurasovic, M.3
  • 44
    • 77957369044 scopus 로고    scopus 로고
    • Effi cacy of silicate-substituted calcium phosphate ceramic in posterolateral instrumented lumbar fusion
    • Jenis LG, Banco RJ . Effi cacy of silicate-substituted calcium phosphate ceramic in posterolateral instrumented lumbar fusion . Spine 2010; 35 : E1058 - 63.
    • (2010) Spine , vol.35
    • Jenis, L.G.1    Banco, R.J.2
  • 45
    • 67349254956 scopus 로고    scopus 로고
    • Clinical and radiographic assessment of transforaminal lumbar interbody fusion using HEALOS collagen-hydroxyapatite sponge with autologous bone marrow aspirate
    • Carter JD, Swearingen AB, Chaput CD, et al . Clinical and radiographic assessment of transforaminal lumbar interbody fusion using HEALOS collagen-hydroxyapatite sponge with autologous bone marrow aspirate . Spine J 2009; 9 : 434 - 8.
    • (2009) Spine J , vol.9 , pp. 434-438
    • Carter, J.D.1    Swearingen, A.B.2    Chaput, C.D.3
  • 46
    • 57849164327 scopus 로고    scopus 로고
    • The results of beta-tricalcium phosphate coated hydroxyapatite (beta-TCP/HA) grafts for interbody fusion after anterior cervical discectomy
    • Cosar M, Ozer AF, Iplikcioglu AC, et al. The results of beta-tricalcium phosphate coated hydroxyapatite (beta-TCP/HA) grafts for interbody fusion after anterior cervical discectomy . J Spinal Disord Tech 2008; 21 : 436 - 41.
    • (2008) J Spinal Disord Tech , vol.21 , pp. 436-441
    • Cosar, M.1    Ozer, A.F.2    Iplikcioglu, A.C.3
  • 47
    • 53349167263 scopus 로고    scopus 로고
    • Effi cacy of anterior cervical fusion: Comparison of titanium cages, polyetheretherketone (PEEK) cages and autogenous bone grafts
    • Chou YC, Chen DC, Hsieh WA, et al. Effi cacy of anterior cervical fusion: Comparison of titanium cages, polyetheretherketone (PEEK) cages and autogenous bone grafts . J Clin Neurosci 2008; 15 : 1240 - 5.
    • (2008) J Clin Neurosci , vol.15 , pp. 1240-1245
    • Chou, Y.C.1    Chen, D.C.2    Hsieh, W.A.3
  • 48
    • 67349287883 scopus 로고    scopus 로고
    • Preliminary comparison of radiolucent cages containing either autogenous cancellous bone or hydroxyapatite graft in multilevel cervical fusion
    • Chang WC, Tsou HK, Chen WS, et al. Preliminary comparison of radiolucent cages containing either autogenous cancellous bone or hydroxyapatite graft in multilevel cervical fusion . J Clin Neurosci 2009; 16 : 793 - 6.
    • (2009) J Clin Neurosci , vol.16 , pp. 793-796
    • Chang, W.C.1    Tsou, H.K.2    Chen, W.S.3
  • 49
    • 37349078709 scopus 로고    scopus 로고
    • Multilevel anterior cervical fusion using a collagen-hydroxyapatite matrix with iliac crest bone marrow aspirate: An 18-month follow-up study
    • discussion
    • Khoueir P, Oh BC, DiRisio DJ, et al. Multilevel anterior cervical fusion using a collagen-hydroxyapatite matrix with iliac crest bone marrow aspirate: An 18-month follow-up study . Neurosurgery 2007; 61 : 963 - 70; discussion 970 - 71.
    • (2007) Neurosurgery , vol.61 , Issue.70-963 , pp. 970-971
    • Khoueir, P.1    Oh, B.C.2    DiRisio, D.J.3
  • 50
    • 33745102356 scopus 로고    scopus 로고
    • Anterior cervical interbody fusion with hydroxyapatite graft and plate system
    • Bruneau M, Nisolle JF, Gilliard C, et al. Anterior cervical interbody fusion with hydroxyapatite graft and plate system . Neurosurg Focus 2001; 10 : E8.
    • (2001) Neurosurg Focus , vol.10
    • Bruneau, M.1    Nisolle, J.F.2    Gilliard, C.3
  • 51
    • 33644746611 scopus 로고    scopus 로고
    • Anterior cervical fusion with polyetheretherketone (PEEK) cages in the treatment of degenerative disc disease. Preliminary observations in 36 consecutive cases with a minimum 12-month follow-up
    • DOI 10.1007/s00701-005-0657-5
    • Mastronardi L, Ducati A, Ferrante L . Anterior cervical fusion with polyetheretherketone (PEEK) cages in the treatment of degenerative disc disease. Preliminary observations in 36 consecutive cases with a minimum 12-month follow-up . Acta Neurochir (Wien) 2006; 148 : 307 - 12; discussion 312. (Pubitemid 43341032)
    • (2006) Acta Neurochirurgica , vol.148 , Issue.3 , pp. 307-312
    • Mastronardi, L.1    Ducati, A.2    Ferrante, L.3
  • 52
    • 33749233163 scopus 로고    scopus 로고
    • Cervical spine operation using coralline hydroxyapatite
    • Tian W, Wang Y, Liu P, et al. [Cervical spine operation using coralline hydroxyapatite] . Zhonghua Wai Ke Za Zhi 2000; 38 : 827 - 30.
    • (2000) Zhonghua Wai Ke Za Zhi , vol.38 , pp. 827-830
    • Tian, W.1    Wang, Y.2    Liu, P.3
  • 53
    • 0033168319 scopus 로고    scopus 로고
    • Anterior interbody fusion of the cervical spine with coralline hydroxyapatite
    • DOI 10.1097/00007632-199907010-00005
    • Thalgott JS, Fritts K, Giuffre JM, et al. Anterior interbody fusion of the cervical spine with coralline hydroxyapatite . Spine (Phila Pa 1976) 1999 ; 24 : 1295 - 9. (Pubitemid 29300342)
    • (1999) Spine , vol.24 , Issue.13 , pp. 1295-1299
    • Thalgott, J.S.1    Fritts, K.2    Giuffre, J.M.3    Timlin, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.