메뉴 건너뛰기




Volumn 82, Issue 5, 2012, Pages 860-867

Assessment of asymmetry in a normal occlusion sample and asymmetric patients with three-dimensional cone beam computed tomography a study for: A transverse reference plane

Author keywords

3D CBCT; Asymmetry; Normal occlusion sample; Skeletal Class III; Transverse reference line

Indexed keywords

ADULT; ANALYSIS OF VARIANCE; ANATOMIC LANDMARK; ARTICLE; CEPHALOMETRY; COMPARATIVE STUDY; CONE BEAM COMPUTED TOMOGRAPHY; FACE ASYMMETRY; FACIAL BONE; FEMALE; HISTOLOGY; HUMAN; MALE; MALOCCLUSION; MANDIBLE; MAXILLA; METHODOLOGY; RADIOGRAPHY; THREE DIMENSIONAL IMAGING; TOOTH OCCLUSION;

EID: 84866513469     PISSN: 00033219     EISSN: 19457103     Source Type: Journal    
DOI: 10.2319/102911-668.1     Document Type: Article
Times cited : (35)

References (21)
  • 4
    • 0030793508 scopus 로고    scopus 로고
    • Occlusal cant in the frontal plane as a reflection of facial asymmetry
    • Padwa BL, Kaiser MO, Kaban LB. Occlusal cant in the frontal plane as a reflection of facial asymmetry. J Oral Maxillofac Surg. 1997;55:811-816.
    • (1997) J Oral Maxillofac Surg. , vol.55 , pp. 811-816
    • Padwa, B.L.1    Kaiser, M.O.2    Kaban, L.B.3
  • 9
    • 79960123585 scopus 로고    scopus 로고
    • Evaluation of facial asymmetry with three-dimensional cone-beam computed tomography
    • Kook YA, Kim Y. Evaluation of facial asymmetry with three-dimensional cone-beam computed tomography. J Clin Orthod. 2011;45:112-115.
    • (2011) J Clin Orthod. , vol.45 , pp. 112-115
    • Kook, Y.A.1    Kim, Y.2
  • 10
    • 43449117523 scopus 로고    scopus 로고
    • Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program
    • Periago DR, Scarfe WC, Moshiri M, Scheetz JP, Silveira AM, Farman AG. Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program. Angle Orthod. 2008;78:387-395.
    • (2008) Angle Orthod. , vol.78 , pp. 387-395
    • Periago, D.R.1    Scarfe, W.C.2    Moshiri, M.3    Scheetz, J.P.4    Silveira, A.M.5    Farman, A.G.6
  • 11
    • 78649707135 scopus 로고    scopus 로고
    • Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans
    • Gribel BF, Gribel MN, Frazao DC, McNamara JA Jr, Manzi FR. Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans. Angle Orthod. 2011;81:26-35.
    • (2011) Angle Orthod. , vol.81 , pp. 26-35
    • Gribel, B.F.1    Gribel, M.N.2    Frazao, D.C.3    Mcnamara Jr., J.A.4    Manzi, F.R.5
  • 12
    • 34547914495 scopus 로고    scopus 로고
    • Accuracy of measurements and reliability of landmark identification with computed tomography (CT) techniques in the maxillofacial area: A systematic review
    • Lou L, Lagravere MO, Compton S, Major PW, Flores-Mir C. Accuracy of measurements and reliability of landmark identification with computed tomography (CT) techniques in the maxillofacial area: a systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;104:402-411.
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod. , vol.104 , pp. 402-411
    • Lou, L.1    Lagravere, M.O.2    Compton, S.3    Major, P.W.4    Flores-Mir, C.5
  • 14
    • 0029187496 scopus 로고
    • Method for quantifying facial asymmetry in three dimensions using stereophotogrammetry
    • Ras F, Habets LL, van Ginkel FC, Prahl-Andersen B. Method for quantifying facial asymmetry in three dimensions using stereophotogrammetry. Angle Orthod. 1995;65:233-239.
    • (1995) Angle Orthod. , vol.65 , pp. 233-239
    • Ras, F.1    Habets, L.L.2    Van Ginkel, F.C.3    Prahl-Andersen, B.4
  • 16
    • 0022759220 scopus 로고
    • The effect of projection errors on cephalometric length measurements
    • Ahlqvist J, Eliasson S, Welander U. The effect of projection errors on cephalometric length measurements. Eur J Orthod. 1986;8:141-148.
    • (1986) Eur J Orthod. , vol.8 , pp. 141-148
    • Ahlqvist, J.1    Eliasson, S.2    Welander, U.3
  • 18
    • 0029285719 scopus 로고
    • Natural head position and natural head orientation: Basic considerations in cephalometric analysis and research
    • Lundstrom A, Lundstrom F, Lebret LM, Moorrees CF. Natural head position and natural head orientation: basic considerations in cephalometric analysis and research. Eur J Orthod. 1995;17:111-120.
    • (1995) Eur J Orthod. , vol.17 , pp. 111-120
    • Lundstrom, A.1    Lundstrom, F.2    Lebret, L.M.3    Moorrees, C.F.4
  • 19
    • 0000838046 scopus 로고
    • A study on the prevalence of malocclusion of Yonsei University students in 1991
    • Ryu YK, Kang HK. A study on the prevalence of malocclusion of Yonsei University students in 1991. Korean J Orthod. 1992;22:691-701.
    • (1992) Korean J Orthod. , vol.22 , pp. 691-701
    • Ryu, Y.K.1    Kang, H.K.2
  • 21
    • 80052466173 scopus 로고    scopus 로고
    • Reproducibility of landmark identification in the jaw and teeth on 3-dimensional conebeam computed tomography images
    • Fuyamada M, Nawa H, Shibata M, Yoshida K, Kise Y, Katsumata A, Ariji E, Goto S. Reproducibility of landmark identification in the jaw and teeth on 3-dimensional conebeam computed tomography images. Angle Orthod. 2011;81:843-849.
    • (2011) Angle Orthod. , vol.81 , pp. 843-849
    • Fuyamada, M.1    Nawa, H.2    Shibata, M.3    Yoshida, K.4    Kise, Y.5    Katsumata, A.6    Ariji, E.7    Goto, S.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.