메뉴 건너뛰기




Volumn 144, Issue 4, 2012, Pages 970-977

Pulsatile control of rotary blood pumps: Does the modulation waveform matter?

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ANIMAL EXPERIMENT; ARTERIAL PRESSURE; ARTERY CANNULA; ARTICLE; BLOOD PUMP; CALIBRATOR; CANNULA; CARDIAC RESYNCHRONIZATION THERAPY DEVICE; COMPUTER PROGRAM; CORONARY ARTERY BLOOD FLOW; DESCENDING AORTA; ELECTROCARDIOGRAPHY MONITORING; FEMALE; HEART BEAT; HEART LEFT VENTRICLE PRESSURE; HEART LEFT VENTRICLE VOLUME; HEART VENTRICLE; HEART WORK; MEDICAL DEVICE; NONHUMAN; PRIORITY JOURNAL; PULSATILE FLOW; PULSING ROTARY BLOOD PUMP SYNCHRONIZATION; SHEEP; ULTRASONIC FLOW PROBE; VELOCITY; VENOUS CANNULA; WAVEFORM;

EID: 84866412801     PISSN: 00225223     EISSN: 1097685X     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2012.02.015     Document Type: Article
Times cited : (63)

References (18)
  • 1
    • 34250810191 scopus 로고    scopus 로고
    • Effect of continuous arterial blood flow in patients with rotary cardiac assist device on the washout of a stenosis wake in the carotid bifurcation: A computer simulation study
    • M. Prosia, K. Perktoldb, and H. Schima Effect of continuous arterial blood flow in patients with rotary cardiac assist device on the washout of a stenosis wake in the carotid bifurcation: a computer simulation study J Biomech 40 2007 2236 2243
    • (2007) J Biomech , vol.40 , pp. 2236-2243
    • Prosia, M.1    Perktoldb, K.2    Schima, H.3
  • 2
    • 58249093243 scopus 로고    scopus 로고
    • Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
    • S. Crow, R. John, and A. Boyle Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices J Thorac Cardiovasc Surg 137 2009 208 215
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 208-215
    • Crow, S.1    John, R.2    Boyle, A.3
  • 3
    • 77957280293 scopus 로고    scopus 로고
    • Management options to treat gastrointestinal bleeding in patients supported on rotary left ventricular assist devices: A single-center experience
    • H.M. Hayes, L.G. Dembo, R. Larbalestier, and G. O'Driscoll Management options to treat gastrointestinal bleeding in patients supported on rotary left ventricular assist devices: a single-center experience Artif Organs 34 2010 703 706
    • (2010) Artif Organs , vol.34 , pp. 703-706
    • Hayes, H.M.1    Dembo, L.G.2    Larbalestier, R.3    O'Driscoll, G.4
  • 4
    • 0027276990 scopus 로고
    • Nonpulsatile mode of blood flow required for cardiopulmonary bypass and total body perfusion
    • Y. Nose Nonpulsatile mode of blood flow required for cardiopulmonary bypass and total body perfusion Artif Organs 1993 1993 92 102
    • (1993) Artif Organs , vol.1993 , pp. 92-102
    • Nose, Y.1
  • 5
    • 2542419343 scopus 로고    scopus 로고
    • Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support
    • A. Undar Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support Artif Organs 28 2004 439 443
    • (2004) Artif Organs , vol.28 , pp. 439-443
    • Undar, A.1
  • 6
    • 33846390671 scopus 로고    scopus 로고
    • Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device
    • A.R. Travis, G.A. Giridharan, and G.M. Pantalos Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device J Thorac Cardiovasc Surg 133 2007 517 524
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 517-524
    • Travis, A.R.1    Giridharan, G.A.2    Pantalos, G.M.3
  • 7
    • 0344994536 scopus 로고    scopus 로고
    • Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device
    • R. Hetzer, J. Muller, and Y. Weng Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device Ann Thorac Surg 68 1999 742 749
    • (1999) Ann Thorac Surg , vol.68 , pp. 742-749
    • Hetzer, R.1    Muller, J.2    Weng, Y.3
  • 8
    • 33646057720 scopus 로고    scopus 로고
    • LVAD-induced reverse remodeling: Basic and clinical implications for myocardial recovery
    • D. Burkhoff, S. Klotz, and D.M. Mancini LVAD-induced reverse remodeling: basic and clinical implications for myocardial recovery J Card Fail 12 2006 227 239
    • (2006) J Card Fail , vol.12 , pp. 227-239
    • Burkhoff, D.1    Klotz, S.2    Mancini, D.M.3
  • 9
    • 0035822606 scopus 로고    scopus 로고
    • Comparison of right and left ventricular responses to left ventricular assist device support in patients with severe heart failure: A primary role of mechanical unloading underlying reverse remodeling
    • A. Barbone, J.W. Holmes, and P.M. Heerdt Comparison of right and left ventricular responses to left ventricular assist device support in patients with severe heart failure: a primary role of mechanical unloading underlying reverse remodeling Circulation 104 2001 670 675
    • (2001) Circulation , vol.104 , pp. 670-675
    • Barbone, A.1    Holmes, J.W.2    Heerdt, P.M.3
  • 10
    • 0036131260 scopus 로고    scopus 로고
    • Partial loading of the left ventricle during mechanical assist device support is associated with improved myocardial function, blood flow and metabolism and increased exercise capacity
    • S. Maybaum, S. Epstein, and A. Beniaminovitz Partial loading of the left ventricle during mechanical assist device support is associated with improved myocardial function, blood flow and metabolism and increased exercise capacity J Heart Lung Transplant 21 2002 446 454
    • (2002) J Heart Lung Transplant , vol.21 , pp. 446-454
    • Maybaum, S.1    Epstein, S.2    Beniaminovitz, A.3
  • 11
    • 0021892137 scopus 로고
    • A real time QRS detection algorithm
    • J. Pan, and W.J. Tompkins A real time QRS detection algorithm IEEE Trans Biomed Eng 32 1985 230 236
    • (1985) IEEE Trans Biomed Eng , vol.32 , pp. 230-236
    • Pan, J.1    Tompkins, W.J.2
  • 12
    • 0030250453 scopus 로고    scopus 로고
    • Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings
    • G.B. Bearnson, D.B. Olsen, and P.S. Khanwilkar Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings ASAIO J 42 1996 620 624
    • (1996) ASAIO J , vol.42 , pp. 620-624
    • Bearnson, G.B.1    Olsen, D.B.2    Khanwilkar, P.S.3
  • 13
    • 0348047551 scopus 로고    scopus 로고
    • Unloading effect of a rotary blood pump assessed by mathematical modeling
    • S. Vandenberghe, P. Segers, B. Meyns, and P.R. Verdonck Unloading effect of a rotary blood pump assessed by mathematical modeling Artif Organs 27 2003 1094 1101
    • (2003) Artif Organs , vol.27 , pp. 1094-1101
    • Vandenberghe, S.1    Segers, P.2    Meyns, B.3    Verdonck, P.R.4
  • 14
    • 68549090655 scopus 로고    scopus 로고
    • A mathematical model to evaluate control strategies for mechanical circulatory support
    • L.G.E. Cox, S. Loerakker, and M.C.M. Rutten A mathematical model to evaluate control strategies for mechanical circulatory support Artif Organs 33 2009 593 603
    • (2009) Artif Organs , vol.33 , pp. 593-603
    • Cox, L.G.E.1    Loerakker, S.2    Rutten, M.C.M.3
  • 15
    • 80051665255 scopus 로고    scopus 로고
    • Effect of pulsatility on the mathematical modeling of rotary blood pumps
    • T. Pirbodaghi, A. Weber, C. Carrel, and S. Vandenberghe Effect of pulsatility on the mathematical modeling of rotary blood pumps Artif Organs 35 2011 825 832
    • (2011) Artif Organs , vol.35 , pp. 825-832
    • Pirbodaghi, T.1    Weber, A.2    Carrel, C.3    Vandenberghe, S.4
  • 16
    • 33644878560 scopus 로고    scopus 로고
    • Hemodynamic modes of ventricular assist with a rotary blood pump: Continuous, pulsatile, and failure
    • S. Vandenberghe, P. Segers, J.F. Antaki, B. Meyns, and P.R. Verdonck Hemodynamic modes of ventricular assist with a rotary blood pump: continuous, pulsatile, and failure ASAIO J 51 2005 711 718
    • (2005) ASAIO J , vol.51 , pp. 711-718
    • Vandenberghe, S.1    Segers, P.2    Antaki, J.F.3    Meyns, B.4    Verdonck, P.R.5
  • 17
    • 27844506165 scopus 로고    scopus 로고
    • Reduced myocardial blood flow during left ventricular assist device support: A possible cause of premature bypass graft closure
    • S. Xydas, R.S. Rosen, and S. Pinney Reduced myocardial blood flow during left ventricular assist device support: a possible cause of premature bypass graft closure J Heart Lung Transplant 24 2005 1976 1979
    • (2005) J Heart Lung Transplant , vol.24 , pp. 1976-1979
    • Xydas, S.1    Rosen, R.S.2    Pinney, S.3
  • 18
    • 0031871850 scopus 로고    scopus 로고
    • The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo
    • A. Ündar, A.J. Lodge, and C.W. Daggett The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo Artif Organs 22 1998 681 686
    • (1998) Artif Organs , vol.22 , pp. 681-686
    • Ündar, A.1    Lodge, A.J.2    Daggett, C.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.