1
-
-
0019607241
-
Streamline upwind/Petrov-Galerkin formulation for convection dominated flows with particular emphasis on the incompressible Navier-Stokes equations
-
Brooks A.N., and Hughes T.J.R. Streamline upwind/Petrov-Galerkin formulation for convection dominated flows with particular emphasis on the incompressible Navier-Stokes equations. Computer Methods in Applied Mechanics and Engineering 32 (1982) 199-259
-
(1982)
Computer Methods in Applied Mechanics and Engineering
, vol.32
, pp. 199-259
-
-
Brooks, A.N.1
Hughes, T.J.R.2
-
2
-
-
85047689580
-
Use of the Jarvik 2000 left ventricular assist system as a bridge to heart transplantation or as destination therapy for patients with chronic heart failure
-
Frazier O.H., Myers T.J., Westaby S., and Gregoric I.D. Use of the Jarvik 2000 left ventricular assist system as a bridge to heart transplantation or as destination therapy for patients with chronic heart failure. Annals of Surgery 237 5 (2003) 631-637
-
(2003)
Annals of Surgery
, vol.237
, Issue.5
, pp. 631-637
-
-
Frazier, O.H.1
Myers, T.J.2
Westaby, S.3
Gregoric, I.D.4
-
3
-
-
0032991356
-
The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90° curved tube
-
Gijsen F.J.H., Allanic E., van de Vosse F.N., and Janssen J.D. The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90° curved tube. Journal of Biomechanics 32 7 (1999) 705-713
-
(1999)
Journal of Biomechanics
, vol.32
, Issue.7
, pp. 705-713
-
-
Gijsen, F.J.H.1
Allanic, E.2
van de Vosse, F.N.3
Janssen, J.D.4
-
4
-
-
0027137176
-
Inflammatory mechanisms of atheroma formation. Influence of fluid mechanics and lipid-derived inflammatory mediators
-
Henry P.D., and Chen C.H. Inflammatory mechanisms of atheroma formation. Influence of fluid mechanics and lipid-derived inflammatory mediators. American Journal of Hypertension 6 11 part 2 (1993) 328S-334S
-
(1993)
American Journal of Hypertension
, vol.6
, Issue.11 PART 2
-
-
Henry, P.D.1
Chen, C.H.2
-
5
-
-
2442455904
-
First experiences with a novel magnetically suspended axial flow left ventricular assist device
-
Hetzer R., Weng Y., Potapov E.V., et al. First experiences with a novel magnetically suspended axial flow left ventricular assist device. European Journal of Cardiothorac Surgery 25 6 (2004) 964-970
-
(2004)
European Journal of Cardiothorac Surgery
, vol.25
, Issue.6
, pp. 964-970
-
-
Hetzer, R.1
Weng, Y.2
Potapov, E.V.3
-
6
-
-
21844483217
-
Vorkonditionierter konjugierter Gradienten Algorithmus für große schlecht konditionierte unsymmetrische Gleichungssysteme
-
Hofer M., and Perktold K. Vorkonditionierter konjugierter Gradienten Algorithmus für große schlecht konditionierte unsymmetrische Gleichungssysteme. Zeitschrift fuer Angewandte Mathematik und Mechanik 75 SII (1995) 641-642
-
(1995)
Zeitschrift fuer Angewandte Mathematik und Mechanik
, vol.75
, Issue.SII
, pp. 641-642
-
-
Hofer, M.1
Perktold, K.2
-
10
-
-
0032972727
-
Outcome of moderate carotid artery stenosis in patients who are asymptomatic
-
[discussion 225-7]
-
Mansour M.A., Littooy F.N., Watson W.C., Blumofe K.A., Heilizer T.J., Steffen G.F., Chmura C., Kang S.S., Labropoulos N., Greisler H.P., Fisher S.G., and Baker W.H.. Outcome of moderate carotid artery stenosis in patients who are asymptomatic. Journal of Vascular Surgery 29 2 (1999) 217-225 [discussion 225-7]
-
(1999)
Journal of Vascular Surgery
, vol.29
, Issue.2
, pp. 217-225
-
-
Mansour, M.A.1
Littooy, F.N.2
Watson, W.C.3
Blumofe, K.A.4
Heilizer, T.J.5
Steffen, G.F.6
Chmura, C.7
Kang, S.S.8
Labropoulos, N.9
Greisler, H.P.10
Fisher, S.G.11
Baker, W.H..12
-
12
-
-
34250829741
-
-
Osenberg, H.P., 1991. Simulation des arteriellen Blutflusses-Ein allgemeines Modell mit Anwendung auf das menschliche Hirngefäßsystem. Ph.D. Thesis, ETH Zürich 9342, IBT Zürich.
-
-
-
-
13
-
-
0001526986
-
Mathematical modeling of local arterial flow and vessel mechanics
-
Crolet J.M., and Ohayon R. (Eds), Longman, Wiley, New York
-
Perktold K., and Rappitsch G. Mathematical modeling of local arterial flow and vessel mechanics. In: Crolet J.M., and Ohayon R. (Eds). Computational Methods for Fluid-Structure Interaction. Pitman Research Notes in Mathematics Series 306 (1994), Longman, Wiley, New York 230-245
-
(1994)
Computational Methods for Fluid-Structure Interaction. Pitman Research Notes in Mathematics Series 306
, pp. 230-245
-
-
Perktold, K.1
Rappitsch, G.2
-
14
-
-
0025719973
-
Pulsatile non-Newtonian flow characteristics in a three-dimensional human carotid bifurcation model
-
Perktold K., Resch M., and Florian H. Pulsatile non-Newtonian flow characteristics in a three-dimensional human carotid bifurcation model. Journal of Biomechanical Engineering 113 (1991) 464-475
-
(1991)
Journal of Biomechanical Engineering
, vol.113
, pp. 464-475
-
-
Perktold, K.1
Resch, M.2
Florian, H.3
-
15
-
-
4544307155
-
Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model
-
Prosi M., Perktold K., Ding Z., and Friedman M.H. Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model. Journal of Biomechanics 37 (2004) 1767-1775
-
(2004)
Journal of Biomechanics
, vol.37
, pp. 1767-1775
-
-
Prosi, M.1
Perktold, K.2
Ding, Z.3
Friedman, M.H.4
-
16
-
-
0034619485
-
Pulsatile flow in patients with a novel nonpulsatile implantable ventricular assist device
-
Potapov E.V., Loebe M., Nasseri B.A., Sinawski H., Koster A., Kuppe H., Noon G.P., De Bakey M.E., and Hetzer R. Pulsatile flow in patients with a novel nonpulsatile implantable ventricular assist device. Circulation 102 19 Suppl. 3 (2000) 183-187
-
(2000)
Circulation
, vol.102
, Issue.19 SUPPL. 3
, pp. 183-187
-
-
Potapov, E.V.1
Loebe, M.2
Nasseri, B.A.3
Sinawski, H.4
Koster, A.5
Kuppe, H.6
Noon, G.P.7
De Bakey, M.E.8
Hetzer, R.9
-
18
-
-
0029809703
-
The effect of blood viscoelasticity on pulsatile flow in stationary and axially moving tubes
-
Sharp M.K., Thurston G.B., and Moore Jr. J.E. The effect of blood viscoelasticity on pulsatile flow in stationary and axially moving tubes. Biorheology 33 (1996) 185-208
-
(1996)
Biorheology
, vol.33
, pp. 185-208
-
-
Sharp, M.K.1
Thurston, G.B.2
Moore Jr., J.E.3
-
19
-
-
0036177777
-
Computational analysis of coupled blood-wall arterial LDL transport
-
Stangeby D.K., and Ethier C.R. Computational analysis of coupled blood-wall arterial LDL transport. Journal of Biomechanical Engineering 124 1 (2002) 1-8
-
(2002)
Journal of Biomechanical Engineering
, vol.124
, Issue.1
, pp. 1-8
-
-
Stangeby, D.K.1
Ethier, C.R.2
-
20
-
-
14644425933
-
Physiology of continuous blood flow in recipients of rotary cardiac assist devices
-
Thalmann M., Schima H., Wieselthaler G., and Wolner E. Physiology of continuous blood flow in recipients of rotary cardiac assist devices. Journal of Heart and Lung Transplantation 24 3 (2005) 237-245
-
(2005)
Journal of Heart and Lung Transplantation
, vol.24
, Issue.3
, pp. 237-245
-
-
Thalmann, M.1
Schima, H.2
Wieselthaler, G.3
Wolner, E.4
-
21
-
-
18844396181
-
Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices
-
Thohan V., Stetson S.J., Nagueh S.F., Rivas-Gotz C., Koerner M.M., Lafuente J.A., Loebe M., Noon G.P., and Torre-Amione G. Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices. Journal of Heart and Lung Transplantation 24 5 (2005) 566-575
-
(2005)
Journal of Heart and Lung Transplantation
, vol.24
, Issue.5
, pp. 566-575
-
-
Thohan, V.1
Stetson, S.J.2
Nagueh, S.F.3
Rivas-Gotz, C.4
Koerner, M.M.5
Lafuente, J.A.6
Loebe, M.7
Noon, G.P.8
Torre-Amione, G.9
-
22
-
-
0036240115
-
Interaction of the cardiovascular system with implanted rotary assist device: simulation study with a refined computer model
-
Vollkron M., Schima H., Huber L., and Wieselthaler G. Interaction of the cardiovascular system with implanted rotary assist device: simulation study with a refined computer model. Artificial Organs 26 (2002) 349-359
-
(2002)
Artificial Organs
, vol.26
, pp. 349-359
-
-
Vollkron, M.1
Schima, H.2
Huber, L.3
Wieselthaler, G.4
-
23
-
-
0034141909
-
First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation
-
Wieselthaler G.M., Schima H., Hiesmayr M., Pacher R., Laufer G., Noon G.P., De Bakey M., and Wolner E. First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation. Circulation 101 4 (2000) 356-359
-
(2000)
Circulation
, vol.101
, Issue.4
, pp. 356-359
-
-
Wieselthaler, G.M.1
Schima, H.2
Hiesmayr, M.3
Pacher, R.4
Laufer, G.5
Noon, G.P.6
De Bakey, M.7
Wolner, E.8
-
24
-
-
0034823969
-
First experiences with outpatient care of patients with implanted axial flow pumps
-
Wieselthaler G.M., Schima H., Dworschak M., Quittan M., Nuhr M., Czerny M., Seebacher G., Huber L., Grimm M., and Wolner E. First experiences with outpatient care of patients with implanted axial flow pumps. Artificial Organs 25 5 (2001) 331-335
-
(2001)
Artificial Organs
, vol.25
, Issue.5
, pp. 331-335
-
-
Wieselthaler, G.M.1
Schima, H.2
Dworschak, M.3
Quittan, M.4
Nuhr, M.5
Czerny, M.6
Seebacher, G.7
Huber, L.8
Grimm, M.9
Wolner, E.10
-
25
-
-
0033302206
-
Fluid mechanics of vascular systems, diseases, and thrombosis
-
Wootton D.M., and Ku D.N. Fluid mechanics of vascular systems, diseases, and thrombosis. Annual Review of Biomedical Engineering 1 (1999) 299-329
-
(1999)
Annual Review of Biomedical Engineering
, vol.1
, pp. 299-329
-
-
Wootton, D.M.1
Ku, D.N.2
|