메뉴 건너뛰기




Volumn 30, Issue 8, 2012, Pages 1099-1110

Elimination of motion and pulsation artifacts using BLADE sequences in knee MR imaging

Author keywords

1.5 T MRI; BLADE sequences; Knee examination; Motion artifacts; Pulsation artifacts

Indexed keywords

ADOLESCENT; ADULT; ANALYTICAL PARAMETERS; ARTICLE; ARTIFACT; ARTIFACT REDUCTION; CONTRAST TO NOISE RATIO; CONTROLLED STUDY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; KNEE RADIOGRAPHY; MAJOR CLINICAL STUDY; MALE; MOTION ARTIFACT; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; PROTON DENSITY BLADE SEQUENCE; PULSATILE FLOW; PULSATION ARTIFACT; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; RADIOLOGIST; RELATIVE CONTRAST; SIGNAL NOISE RATIO;

EID: 84866171575     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2012.04.001     Document Type: Article
Times cited : (22)

References (30)
  • 1
    • 0029910595 scopus 로고    scopus 로고
    • Usefulness of turbo spin-echo MR imaging in the evaluation of meniscal tears: comparison with a conventional spin-echo sequence
    • Escobedo E.M., Hunter J.C., Zink-Brody G.C., Wilson A.J., Harrison S.D., Fisher D.J. Usefulness of turbo spin-echo MR imaging in the evaluation of meniscal tears: comparison with a conventional spin-echo sequence. AJR 1996, 167:1223-1227.
    • (1996) AJR , vol.167 , pp. 1223-1227
    • Escobedo, E.M.1    Hunter, J.C.2    Zink-Brody, G.C.3    Wilson, A.J.4    Harrison, S.D.5    Fisher, D.J.6
  • 2
    • 0031896508 scopus 로고    scopus 로고
    • Anterior cruciate ligament injury: fast spin-echo MR imaging with arthroscopic correlation in 217 examinations
    • Beaulieu C.F., et al. Anterior cruciate ligament injury: fast spin-echo MR imaging with arthroscopic correlation in 217 examinations. AJR 1998, 170:1215-1219.
    • (1998) AJR , vol.170 , pp. 1215-1219
    • Beaulieu, C.F.1
  • 4
    • 0035113497 scopus 로고    scopus 로고
    • MRI of anterior cruciate ligament repair with patellar and hamstring tendon autografts
    • Jansson K.A., Karjalainen P.T., Harilainen A., et al. MRI of anterior cruciate ligament repair with patellar and hamstring tendon autografts. Skeletal Radiol 2001, 30:8-14.
    • (2001) Skeletal Radiol , vol.30 , pp. 8-14
    • Jansson, K.A.1    Karjalainen, P.T.2    Harilainen, A.3
  • 5
    • 0036939393 scopus 로고    scopus 로고
    • Axial fat-saturated FSE imaging of knee: appearance of meniscal tears
    • Lee J.H., Singh T.T., Bolton G. Axial fat-saturated FSE imaging of knee: appearance of meniscal tears. Skeletal Radiol 2002, 31:384-395.
    • (2002) Skeletal Radiol , vol.31 , pp. 384-395
    • Lee, J.H.1    Singh, T.T.2    Bolton, G.3
  • 6
    • 0021958023 scopus 로고
    • MR image artifacts from periodic motion
    • Wood M.L., Henkelman R.M. MR image artifacts from periodic motion. Med Phys 1985, 12:143-151.
    • (1985) Med Phys , vol.12 , pp. 143-151
    • Wood, M.L.1    Henkelman, R.M.2
  • 7
    • 0022260368 scopus 로고
    • Respiratory ordering of phase encoding (ROPE): a method for reducing respiratory motion artifacts in MR imaging
    • Bailes D.R., Gilderdale D.J., Bydder G.M. Respiratory ordering of phase encoding (ROPE): a method for reducing respiratory motion artifacts in MR imaging. J Comput Assist Tomogr 1985, 9:835-838.
    • (1985) J Comput Assist Tomogr , vol.9 , pp. 835-838
    • Bailes, D.R.1    Gilderdale, D.J.2    Bydder, G.M.3
  • 8
    • 0023180462 scopus 로고
    • Motion artifact suppression technique (MAST) for MR imaging
    • Pattany P.M., Phillips J.J., Chiu L.C. Motion artifact suppression technique (MAST) for MR imaging. J Comput Assist Tomogr 1987, 11:369-377.
    • (1987) J Comput Assist Tomogr , vol.11 , pp. 369-377
    • Pattany, P.M.1    Phillips, J.J.2    Chiu, L.C.3
  • 9
    • 0023217321 scopus 로고
    • Improving MR image quality in the presence of motion by using rephrasing gradients
    • Haacke E.M., Lenz G.W. Improving MR image quality in the presence of motion by using rephrasing gradients. AJR 1987, 148:1251-1258.
    • (1987) AJR , vol.148 , pp. 1251-1258
    • Haacke, E.M.1    Lenz, G.W.2
  • 10
    • 0023197057 scopus 로고
    • Spatial presaturation: a method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging
    • Felmlee J.P., Ehman R.L. Spatial presaturation: a method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging. Radiology 1987, 164:559-5134.
    • (1987) Radiology , vol.164 , pp. 559-5134
    • Felmlee, J.P.1    Ehman, R.L.2
  • 11
    • 0023836361 scopus 로고
    • Acquisition order and motional artifact reduction in spin warp images
    • Dixon W.T., Brummer M.E., Malko J.A. Acquisition order and motional artifact reduction in spin warp images. Magn Reson Med 1988, 6:74-83.
    • (1988) Magn Reson Med , vol.6 , pp. 74-83
    • Dixon, W.T.1    Brummer, M.E.2    Malko, J.A.3
  • 13
    • 0024003864 scopus 로고
    • The straight and narrow path to good head and spine MRI
    • Runge V.M., Wood M.L., Kaufman D.M., et al. The straight and narrow path to good head and spine MRI. Radiographics 1988, 8:507-531.
    • (1988) Radiographics , vol.8 , pp. 507-531
    • Runge, V.M.1    Wood, M.L.2    Kaufman, D.M.3
  • 14
    • 0034821969 scopus 로고    scopus 로고
    • Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: initial experience
    • Kallmes D.F., Hui F.K., Mugler J.P. Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: initial experience. Radiographics 2001, 221:251-255.
    • (2001) Radiographics , vol.221 , pp. 251-255
    • Kallmes, D.F.1    Hui, F.K.2    Mugler, J.P.3
  • 15
    • 39049165143 scopus 로고    scopus 로고
    • Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence
    • Naganawa S., Satake H., Iwano S., et al. Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence. Eur Radiol 2008, 18:337-342.
    • (2008) Eur Radiol , vol.18 , pp. 337-342
    • Naganawa, S.1    Satake, H.2    Iwano, S.3
  • 16
    • 46649083409 scopus 로고    scopus 로고
    • Contrast enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?
    • Alibek S., Adamietz B., Cavallaro A., et al. Contrast enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?. Acta Radiol 2008, 15:986-995.
    • (2008) Acta Radiol , vol.15 , pp. 986-995
    • Alibek, S.1    Adamietz, B.2    Cavallaro, A.3
  • 17
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging
    • Pipe J.G. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999, 42:963-969.
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 18
    • 0032835537 scopus 로고    scopus 로고
    • An optimized center-out k-space trajectory for multishot MRI: comparison with spiral and projection reconstruction
    • Pipe J.G. An optimized center-out k-space trajectory for multishot MRI: comparison with spiral and projection reconstruction. Magn Reson Med 1999, 42:714-720.
    • (1999) Magn Reson Med , vol.42 , pp. 714-720
    • Pipe, J.G.1
  • 19
    • 7044274247 scopus 로고    scopus 로고
    • Magnetic resonance imaging of articular cartilage of the knee: comparison between fat suppressed three-dimensional SPGR imaging, fat-suppressed FSE imaging, and fat-suppressed three-dimensional DEFT imaging, and correlation with arthroscopy
    • Yoshioka H., Stevens K., Hargreaves B.A., Steines D., Genovese M., Dillingham M.F., et al. Magnetic resonance imaging of articular cartilage of the knee: comparison between fat suppressed three-dimensional SPGR imaging, fat-suppressed FSE imaging, and fat-suppressed three-dimensional DEFT imaging, and correlation with arthroscopy. J Magn Reson Imaging 2004, 20:857-864.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 857-864
    • Yoshioka, H.1    Stevens, K.2    Hargreaves, B.A.3    Steines, D.4    Genovese, M.5    Dillingham, M.F.6
  • 20
    • 53549091578 scopus 로고    scopus 로고
    • Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen
    • Hirokawa Y., Isoda H., Maetani Y.S., Arizono S., Shimada K., Togashi K. Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen. J Magn Reson Imaging 2008, 28:957-962.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 957-962
    • Hirokawa, Y.1    Isoda, H.2    Maetani, Y.S.3    Arizono, S.4    Shimada, K.5    Togashi, K.6
  • 21
    • 72849136945 scopus 로고    scopus 로고
    • Reduced artefacts and improved assessment of hyperintense brain lesions with BLADE MR imaging in patients with neurofibromatosis type
    • von Kalle T., Blank B., Fabig-Moritz C., Müller-Abt P., Zieger M., Wohlfarth K., Winkler P. Reduced artefacts and improved assessment of hyperintense brain lesions with BLADE MR imaging in patients with neurofibromatosis type. Pediatr Radiol 2009, 39:1216-1222.
    • (2009) Pediatr Radiol , vol.39 , pp. 1216-1222
    • von Kalle, T.1    Blank, B.2    Fabig-Moritz, C.3    Müller-Abt, P.4    Zieger, M.5    Wohlfarth, K.6    Winkler, P.7
  • 22
    • 0023910466 scopus 로고
    • Motion artifacts in brain and spine MR
    • Hinks R.S., Quencer R.M. Motion artifacts in brain and spine MR. Radiol Clin North Am 1988, 26:737-753.
    • (1988) Radiol Clin North Am , vol.26 , pp. 737-753
    • Hinks, R.S.1    Quencer, R.M.2
  • 23
    • 78349253084 scopus 로고    scopus 로고
    • Is there a role for BLADE acquisition in T2-weighted breast MRI?
    • Ozcan U.A., Dincer A., Yildiz M.E., Cinko M., Cizmeli M.O. Is there a role for BLADE acquisition in T2-weighted breast MRI?. Acta Radiol 2010, 51:1067-1077.
    • (2010) Acta Radiol , vol.51 , pp. 1067-1077
    • Ozcan, U.A.1    Dincer, A.2    Yildiz, M.E.3    Cinko, M.4    Cizmeli, M.O.5
  • 24
    • 0026104238 scopus 로고
    • Prepontine artifacts due to cerebrospinal fluid pulsation in the T2-weighted coronal MR picture. Clinical significance, frequency and a technique for artefact suppression
    • Böck J.C., Neumann K., Sander B., et al. Prepontine artifacts due to cerebrospinal fluid pulsation in the T2-weighted coronal MR picture. Clinical significance, frequency and a technique for artefact suppression. RoFo 1991, 154:202-205.
    • (1991) RoFo , vol.154 , pp. 202-205
    • Böck, J.C.1    Neumann, K.2    Sander, B.3
  • 25
    • 77951966333 scopus 로고    scopus 로고
    • Fat-suppressed 3D T1-weighted gradient-echo imaging of the cartilage with a volumetric interpolated breath-hold examination
    • Zheng Z.Z., Shan H., Li X. Fat-suppressed 3D T1-weighted gradient-echo imaging of the cartilage with a volumetric interpolated breath-hold examination. Am J Roentgenol 2010, 194:W414-W419.
    • (2010) Am J Roentgenol , vol.194
    • Zheng, Z.Z.1    Shan, H.2    Li, X.3
  • 28
    • 33747144129 scopus 로고    scopus 로고
    • Comparison of 3.0 T versus 1.5 T MR: imaging of the spine
    • Phalke V.V., Gujar S., Quint D.J. Comparison of 3.0 T versus 1.5 T MR: imaging of the spine. Neuroimaging Clin N Am 2006, 16:241-248.
    • (2006) Neuroimaging Clin N Am , vol.16 , pp. 241-248
    • Phalke, V.V.1    Gujar, S.2    Quint, D.J.3
  • 29
    • 33644835009 scopus 로고    scopus 로고
    • 3.0T MR imaging of the musculoskeletal system (part I): considerations, coils, and challenges
    • Ramnath R.R. 3.0T MR imaging of the musculoskeletal system (part I): considerations, coils, and challenges. Magn Reson Imaging Clin N Am 2006, 14:27-40.
    • (2006) Magn Reson Imaging Clin N Am , vol.14 , pp. 27-40
    • Ramnath, R.R.1
  • 30
    • 37549014118 scopus 로고    scopus 로고
    • Artifacts in 3-T MRI: physical background and reduction strategies
    • Dietrich O., Reiser M.F., Schoenberg S.O. Artifacts in 3-T MRI: physical background and reduction strategies. Eur J Radiol 2008, 65:29-35.
    • (2008) Eur J Radiol , vol.65 , pp. 29-35
    • Dietrich, O.1    Reiser, M.F.2    Schoenberg, S.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.