메뉴 건너뛰기




Volumn 31, Issue 7, 2002, Pages 384-395

Axial fat-saturated FSE imaging of knee: Appearance of meniscal tears

Author keywords

Fast spin echo; Knee; Knee meniscus; Magnetic resonance imaging; Tear, knee meniscus

Indexed keywords

ADULT; ARTICLE; CLINICAL FEATURE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DISEASE CLASSIFICATION; FEMALE; HUMAN; IMAGING SYSTEM; KNEE ARTHROSCOPY; KNEE MENISCUS RUPTURE; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; RETROSPECTIVE STUDY; VALIDATION PROCESS;

EID: 0036939393     PISSN: 03642348     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00256-002-0507-y     Document Type: Article
Times cited : (22)

References (11)
  • 1
    • 0032753277 scopus 로고    scopus 로고
    • Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients
    • Bredella MA, Tirman PF, Peterfy CG, Zarlingo M, Feller JF, Bost FW, et al. Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: comparison with arthroscopy in 130 patients. AJR Am J Roentgenol 1999; 172:1073-1080.
    • (1999) AJR Am. J. Roentgenol. , vol.172 , pp. 1073-1080
    • Bredella, M.A.1    Tirman, P.F.2    Peterfy, C.G.3    Zarlingo, M.4    Feller, J.F.5    Bost, F.W.6
  • 3
    • 0026608427 scopus 로고
    • MR diagnosis of meniscal tears of the knee: Value of axial threedimensional Fourier transformation GRASS images
    • Araki Y, Ootani F, Tsukaguchi I, Ootani M, Furukawa T, Yamamoto T, et al. MR diagnosis of meniscal tears of the knee: value of axial threedimensional Fourier transformation GRASS images. AJR Am J Roentgenol 1992; 158:587-590.
    • (1992) AJR Am. J. Roentgenol. , vol.158 , pp. 587-590
    • Araki, Y.1    Ootani, F.2    Tsukaguchi, I.3    Ootani, M.4    Furukawa, T.5    Yamamoto, T.6
  • 4
    • 0026638746 scopus 로고
    • MR knee imaging: Axial 3DFT GRASS pulse sequence versus spin-echo imaging for detecting meniscal tears
    • Aubel S, Heyd RL, Thaete FL, Wozney P. MR knee imaging: axial 3DFT GRASS pulse sequence versus spin-echo imaging for detecting meniscal tears. Magn Reson Imaging 1992; 10:531-539.
    • (1992) Magn. Reson. Imaging , vol.10 , pp. 531-539
    • Aubel, S.1    Heyd, R.L.2    Thaete, F.L.3    Wozney, P.4
  • 6
    • 0029121367 scopus 로고
    • Bucket-handle tears of the medial and lateral menisci of the knee: Value of MR imaging in detecting displaced fragments
    • [see comments]
    • Wright DH, De Smet AA, Norris M. Bucket-handle tears of the medial and lateral menisci of the knee: value of MR imaging in detecting displaced fragments [see comments]. AJR Am J Roentgenol 1995; 165:621-625.
    • (1995) AJR Am. J. Roentgenol. , vol.165 , pp. 621-625
    • Wright, D.H.1    De Smet, A.A.2    Norris, M.3
  • 7
    • 0031935767 scopus 로고    scopus 로고
    • The absent bow tie sign in bucket-handle tears of the menisci in the knee
    • Helms CA, Laorr A, Cannon WD, Jr. The absent bow tie sign in bucket-handle tears of the menisci in the knee. AJR Am J Roentgenol 1998; 170:57-61.
    • (1998) AJR Am. J. Roentgenol. , vol.170 , pp. 57-61
    • Helms, C.A.1    Laorr, A.2    Cannon W.D., Jr.3
  • 9
    • 0028340881 scopus 로고
    • "Magic-angle" phenomenon: A cause of increased signal in the normal lateral meniscus on short-TE MR images of the knee
    • Peterfy CG, Janzen DL, Tirman PF, van Dijke CF, Pollack M, Genant HK. "Magic-angle" phenomenon: a cause of increased signal in the normal lateral meniscus on short-TE MR images of the knee. AJR Am J Roentgenol 1994; 163:149-154.
    • (1994) AJR Am. J. Roentgenol. , vol.163 , pp. 149-154
    • Peterfy, C.G.1    Janzen, D.L.2    Tirman, P.F.3    van Dijke, C.F.4    Pollack, M.5    Genant, H.K.6
  • 10
    • 0031975450 scopus 로고    scopus 로고
    • The magic angle phenomenon in tendons: Effect of varying the MR echo time
    • Peh WC, Chan JH. The magic angle phenomenon in tendons: effect of varying the MR echo time. Br J Radiol 1998; 71:31-36.
    • (1998) Br. J. Radiol. , vol.71 , pp. 31-36
    • Peh, W.C.1    Chan, J.H.2
  • 11
    • 0030471534 scopus 로고    scopus 로고
    • Coronal fat suppression fast spin echo images of the knee: Evaluation of 202 patients with arthroscopic correlation
    • Kojima KY, Demlow TA, Szumowski J, Quinn SF. Coronal fat suppression fast spin echo images of the knee: evaluation of 202 patients with arthroscopic correlation. Magn Reson Imaging 1996; 14:1017-1022.
    • (1996) Magn. Reson. Imaging , vol.14 , pp. 1017-1022
    • Kojima, K.Y.1    Demlow, T.A.2    Szumowski, J.3    Quinn, S.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.