Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments

Author keywords

Abdominal; Instruments; Technical; Vascular (blood vessels)

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTERY DISSECTION; ARTICLE; BIPOLAR CLAMP; COMPARATIVE STUDY; HISTOLOGY; LAPAROSCOPIC SURGERY; NONHUMAN; PRESSURE MEASUREMENT; PRIORITY JOURNAL; SAFETY; SURGICAL EQUIPMENT; SURGICAL SCISSOR; SURGICAL TECHNIQUE; SWINE; TEMPERATURE; ULTRASONIC SCISSOR;

EID: 84866114200     PISSN: 09302794     EISSN: 14322218     Source Type: Journal    
DOI: 10.1007/s00464-012-2229-0     Document Type: Article
Times cited : (99)

References (21)
  • 3
    • 34548462578 scopus 로고    scopus 로고
    • Electrothermal bipolar vessel sealing device versus ultrasonic coagulating shears in laparoscopic colectomies: A comparative study
    • 17287913 10.1007/s00464-006-9143-2
    • Campagnacci R, de Sanctis A, Baldarelli M, Rimini M, Lezoche G, Guerrieri M (2007) Electrothermal bipolar vessel sealing device versus ultrasonic coagulating shears in laparoscopic colectomies: a comparative study. Surg Endosc 21:1526-1531
    • (2007) Surg Endosc , vol.21 , pp. 1526-1531
    • Campagnacci, R.1    De Sanctis, A.2    Baldarelli, M.3    Rimini, M.4    Lezoche, G.5    Guerrieri, M.6
  • 5
    • 0034101090 scopus 로고    scopus 로고
    • Initial experience with the harmonic scalpel in liver surgery
    • 10919028 1:STN:280:DC%2BD3M%2FksF2gtA%3D%3D
    • Gertsch P, Pelloni A, Guerra A, Krpo A (2000) Initial experience with the harmonic scalpel in liver surgery. Hepatogastroenterology 47:763-766
    • (2000) Hepatogastroenterology , vol.47 , pp. 763-766
    • Gertsch, P.1    Pelloni, A.2    Guerra, A.3    Krpo, A.4
  • 6
    • 67651051854 scopus 로고    scopus 로고
    • Laparoscopic versus open nephroureterectomy: Perioperative and oncologic outcomes from a randomised prospective study
    • 19560259 10.1016/j.eururo.2009.06.013
    • Simone G, Papalia R, Guaglianone S, Ferriero M, Leonardo C, Forastiere E, Gallucci M (2009) Laparoscopic versus open nephroureterectomy: perioperative and oncologic outcomes from a randomised prospective study. Eur Urol 56(3):520-526
    • (2009) Eur Urol , vol.56 , Issue.3 , pp. 520-526
    • Simone, G.1    Papalia, R.2    Guaglianone, S.3    Ferriero, M.4    Leonardo, C.5    Forastiere, E.6    Gallucci, M.7
  • 7
    • 80051703756 scopus 로고    scopus 로고
    • A randomized prospective study of single-port and four-port approaches for hysterectomy in terms of postoperative pain
    • 21298522 10.1007/s00464-010-1567-z
    • Jung YW, Lee M, Yim GW, Lee SH, Paek JH, Kwon HY, Nam EJ, Kim SW, Kim YT (2011) A randomized prospective study of single-port and four-port approaches for hysterectomy in terms of postoperative pain. Surg Endosc 25(8):2462-2469
    • (2011) Surg Endosc , vol.25 , Issue.8 , pp. 2462-2469
    • Jung, Y.W.1    Lee, M.2    Yim, G.W.3    Lee, S.H.4    Paek, J.H.5    Kwon, H.Y.6    Nam, E.J.7    Kim, S.W.8    Kim, Y.T.9
  • 8
    • 85047693399 scopus 로고    scopus 로고
    • How safe is high-power ultrasonic dissection?
    • 12560776
    • Emam TA, Cuschieri A (2003) How safe is high-power ultrasonic dissection? Ann Surg 237:186-191
    • (2003) Ann Surg , vol.237 , pp. 186-191
    • Emam, T.A.1    Cuschieri, A.2
  • 9
    • 0345015462 scopus 로고    scopus 로고
    • Real-time thermography during energized vessel sealing and dissection
    • 12874690 10.1007/s00464-002-8781-2 1:STN:280:DC%2BD3sngs1Ohsw%3D%3D
    • Campbell PA, Cresswell AB, Frank TG, Cuschieri A (2003) Real-time thermography during energized vessel sealing and dissection. Surg Endosc 17:1640-1645
    • (2003) Surg Endosc , vol.17 , pp. 1640-1645
    • Campbell, P.A.1    Cresswell, A.B.2    Frank, T.G.3    Cuschieri, A.4
  • 10
    • 43749124249 scopus 로고    scopus 로고
    • Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure v (LV), and plasma trisector (PT)
    • 18027042 10.1007/s00464-007-9650-9 1:STN:280:DC%2BD1czgvFWjug%3D%3D
    • Kim FJ, Chammas MF Jr, Gewehr E, Morihisa M, Caldas F, Hayacibara E, Baptistussi M, Meyer F, Martins AC (2008) Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT). Surg Endosc 22:1464-1469
    • (2008) Surg Endosc , vol.22 , pp. 1464-1469
    • Kim, F.J.1    Chammas, Jr.M.F.2    Gewehr, E.3    Morihisa, M.4    Caldas, F.5    Hayacibara, E.6    Baptistussi, M.7    Meyer, F.8    Martins, A.C.9
  • 11
    • 39149134560 scopus 로고    scopus 로고
    • Comparison of four energy-based vascular sealing and cutting instruments: A porcine model
    • 18097720 10.1007/s00464-007-9619-8
    • Person B, Vivas DA, Ruiz D, Talcott M, Coad JE, Wexner SD (2008) Comparison of four energy-based vascular sealing and cutting instruments: a porcine model. Surg Endosc 22:534-538
    • (2008) Surg Endosc , vol.22 , pp. 534-538
    • Person, B.1    Vivas, D.A.2    Ruiz, D.3    Talcott, M.4    Coad, J.E.5    Wexner, S.D.6
  • 12
    • 79954930839 scopus 로고    scopus 로고
    • Efficacy and safety of 5-mm-diameter bipolar and ultrasonic shears for cutting carotid arteries of the hybrid pig
    • 20614136 10.1007/s00464-010-1224-6
    • Mantke R, Halangk W, Habermann A, Peters B, Konrad S, Guenther M, Lippert H (2011) Efficacy and safety of 5-mm-diameter bipolar and ultrasonic shears for cutting carotid arteries of the hybrid pig. Surg Endosc 25:577-578
    • (2011) Surg Endosc , vol.25 , pp. 577-578
    • Mantke, R.1    Halangk, W.2    Habermann, A.3    Peters, B.4    Konrad, S.5    Guenther, M.6    Lippert, H.7
  • 13
    • 80051682586 scopus 로고    scopus 로고
    • Collagen-elastin ratio predicts burst pressure of arterial seals created using a bipolar vessel sealing device in a porcine model
    • 21404086 10.1007/s00464-011-1606-4
    • Sindram D, Martin K, Meadows JP, Prabhu AS, Heath JJ, McKillop IH, Iannitti DA (2011) Collagen-elastin ratio predicts burst pressure of arterial seals created using a bipolar vessel sealing device in a porcine model. Surg Endosc 25(8):2604-2612
    • (2011) Surg Endosc , vol.25 , Issue.8 , pp. 2604-2612
    • Sindram, D.1    Martin, K.2    Meadows, J.P.3    Prabhu, A.S.4    Heath, J.J.5    McKillop, I.H.6    Iannitti, D.A.7
  • 14
    • 46249129085 scopus 로고    scopus 로고
    • The effect of intraluminal content on the bursting strength of vessels ligated with the harmonic ACE and LigaSure v
    • 18578667 10.1089/end.2008.0079
    • Phillips CK, Hruby GW, Mirabile G, Motamedinia P, Durak E, Lehman DS, Hong PW, Landman J (2008) The effect of intraluminal content on the bursting strength of vessels ligated with the harmonic ACE and LigaSure V. J Endourol 22:1383-1387
    • (2008) J Endourol , vol.22 , pp. 1383-1387
    • Phillips, C.K.1    Hruby, G.W.2    Mirabile, G.3    Motamedinia, P.4    Durak, E.5    Lehman, D.S.6    Hong, P.W.7    Landman, J.8
  • 17
    • 84866109171 scopus 로고
    • Thermal degradation of hide collagen and tanned hide collagen
    • Takenouchi K (1982) Thermal degradation of hide collagen and tanned hide collagen. Jpn J Zootech Sci 53:488-496
    • (1982) Jpn J Zootech Sci , vol.53 , pp. 488-496
    • Takenouchi, K.1
  • 18
    • 0033255064 scopus 로고    scopus 로고
    • Ultrasonic energy in endoscopic surgery
    • 10661030 1:STN:280:DC%2BD3c7is1yksQ%3D%3D
    • Lee SJ, Park KH (1999) Ultrasonic energy in endoscopic surgery. Yonsei Med J 40:545-549
    • (1999) Yonsei Med J , vol.40 , pp. 545-549
    • Lee, S.J.1    Park, K.H.2
  • 19
    • 1442359035 scopus 로고    scopus 로고
    • Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: An analysis of 200 cases in a randomized trial
    • 15035837 10.1089/109264204322862289
    • Ortega J, Sala C, Flor B, Lledo S (2004) Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 14:9-12
    • (2004) J Laparoendosc Adv Surg Tech A , vol.14 , pp. 9-12
    • Ortega, J.1    Sala, C.2    Flor, B.3    Lledo, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.